Plan Review Details - Permit 06030268
Plan Review Stops For Permit 06030268
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-25 Cont ID  
Sent By amorse Date 2006-05-25 Time 06:43 Rev Time 0.33
Received By amorse Date 2006-05-25 Time 06:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-31 Cont ID  
Sent By amorse Date 2006-03-31 Time 14:37 Rev Time 0.50
Received By amorse Date 2006-03-31 Time 14:36 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-06 Cont ID  
Sent By btrobaug Date 2006-06-06 Time 15:50 Rev Time 0.50
Received By btrobaug Date 2006-06-06 Time 15:45 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-04-18 Cont ID  
Sent By btrobaug Date 2006-04-18 Time 17:33 Rev Time 0.50
Received By btrobaug Date 2006-04-18 Time 17:18 Sent To Z
Notes
2006-04-18 00:00:00 
 FAILED
 SAME NOTES AS PREVIOUS REVIEW (3.20.06),
 PLEASE SEE THAT MR SINCLAIR GETS AN
 OPPORTUNITY TO SEE THE COMMENTS BEFORE
 RESUBMITTING
  
 THE PLAN INDICATES 3-#4 CU FEEDERS TO
 THE POOL PANEL. THE CALCULATION PROVIDED
 BYTHE ELECTRICAL CONTRACTOR INDICATES A
 30 AMP FEED TO A POOL PANEL. PLEASE
 CORRELATE.
  
 NOTE #1 AT THE ELECTRICAL SCHEMATIC
 REFERENCES THE 2005 NEC. PLEASE NOTE THE
 STATE HAS NOT YET ADOPTED 2005 AND WE
 ARE CURRENTLY ENFORCING 2002 NEC.
  
 DIFFERENTCOMMENT FROM THIS REVIEW,
 THERE IS A HEATER (PRESUMABLY ELECTRIC)
 ON THE ELECTRICAL SCHEMATIC THAT SHOULD
 BE REMOVED . IF THE HEATER IS GAS THERE
 SHOULD ONLY BE AN IGNITOR INDICATED IF
 120V.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-20 Cont ID  
Sent By btrobaug Date 2006-03-20 Time 09:38 Rev Time 0.33
Received By btrobaug Date 2006-03-20 Time 09:25 Sent To P
Notes
2006-03-20 00:00:00 
 FAILED
  
 THE PLAN INDICATES 3-#4 CU FEDERS TO THE
 POOL PANEL. THE CALCULATION PROVIDED BY
 THE ELECTRICAL CONTRACTOR INDICATES A 30
 AMP FEEDTO A POOL PANEL. PLEASE
 CORRELATE.
  
 NOTE #1 AT THE ELECTRICAL SCHEMATIC
 REFERENCES THE 2005 NEC. PLEASE NOTE THE
 STATE HAS NOT YET ADOPTED 2005 AND WE
 ARE CURRENTLY ENFORCING 2002 NEC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-05-24 Cont ID  
Sent By mperson Date 2006-05-24 Time 13:04 Rev Time 0.00
Received By mperson Date 2006-05-24 Time 13:04 Sent To  
Notes
2006-05-24 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-03-21 Cont ID  
Sent By mperson Date 2006-03-21 Time 09:14 Rev Time 0.00
Received By mperson Date 2006-03-21 Time 09:14 Sent To  
Notes
2006-03-21 00:00:00GAS PERMIT REQUIRED. GAS CONTRACTER TO
 SUBMIT PLANS WITH PERMIT APPLICATION.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-06-06 Cont ID  
Sent By adarroug Date 2006-06-06 Time 12:24 Rev Time 0.00
Received By adarroug Date 2006-06-06 Time 12:24 Sent To E
Notes
2006-06-06 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-05-27 Cont ID  
Sent By adarroug Date 2006-05-27 Time 13:30 Rev Time 0.00
Received By adarroug Date 2006-05-27 Time 13:30 Sent To Z
Notes
2006-05-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 11:23 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 11:23 Sent To E
Notes
2006-05-22 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-01 Cont ID  
Sent By adarroug Date 2006-05-01 Time 10:21 Rev Time 0.00
Received By adarroug Date 2006-05-01 Time 10:21 Sent To Z
Notes
2006-05-01 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 16:54 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 16:54 Sent To Z
Notes
2006-04-12 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-16 Cont ID  
Sent By adarroug Date 2006-03-16 Time 13:59 Rev Time 0.00
Received By adarroug Date 2006-03-16 Time 13:59 Sent To E
Notes
2006-03-16 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-03-31 Time   Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 13:40 Sent To  
Notes
2006-03-09 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-24 Cont ID  
Sent By mperson Date 2006-05-24 Time 13:03 Rev Time 0.33
Received By mperson Date 2006-05-24 Time 13:03 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-03-21 Cont ID  
Sent By mperson Date 2006-03-21 Time 09:17 Rev Time 0.45
Received By mperson Date 2006-03-21 Time 09:17 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2006-06-05 Cont ID  
Sent By mmclean Date 2006-06-05 Time 16:11 Rev Time 0.00
Received By mmclean Date 2006-06-05 Time 16:11 Sent To I
Notes
2006-06-05 00:00:00POOL EQUIP SETBACK IS 10.5FT FROM
 PROPERTY LINE.

Review Stop Z ZONING
Rev No 4 Status F Date 2006-06-04 Cont ID  
Sent By mmclean Date 2006-06-04 Time 10:28 Rev Time 0.00
Received By mmclean Date 2006-06-04 Time 10:28 Sent To I
Notes
2006-06-04 00:00:00DENIED,
 1. THE PROPOSED SPA MUST BE MINIMUM OF
 5FT FROM PROPERTY LINE (REAR). SHOWN ON
 SURVEY AS 4.25FT.
 2. MUST PROVIDE THE SETBACK OF THE POOL
 EQUIPMENT FROM SIDE PROPERTY LINE ON TWO
 COPY OF SURVEY.
  
 NOTE: SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 3 Status F Date 2006-05-18 Cont ID  
Sent By mmclean Date 2006-05-18 Time 13:44 Rev Time 0.00
Received By amorse Date 2006-05-18 Time 06:40 Sent To I
Notes
2006-05-18 00:00:00DENIED.
 1. MUST PROVIDE TWO COPY OF THE APPROVED
 SURVEY OR TWO NEW COPY OF SURVEY SHOWING
 THE LOCATION POOL WITH SETBACKS.
  
 (NO SURVEYS WAS RESUBMITTED IN PACKAGE)
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status P Date 2006-04-21 Cont ID  
Sent By mmclean Date 2006-04-21 Time 11:41 Rev Time 0.00
Received By mmclean Date 2006-04-21 Time 11:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-03-14 Cont ID  
Sent By mmclean Date 2006-03-14 Time 13:53 Rev Time 0.00
Received By mmclean Date 2006-03-14 Time 13:53 Sent To I
Notes
2006-03-14 00:00:00DENIED,
 1. SPA MUST BE 5FT IN REAR. SURVEY SHOW
 4.25FT FROM WATERS EDGE TO PROPERTY
 LINE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720