Plan Review Details - Permit 06030168
Plan Review Stops For Permit 06030168
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-06-21 Cont ID  
Sent By btrobaug Date 2006-06-21 Time 18:15 Rev Time 0.50
Received By btrobaug Date 2006-06-21 Time 17:59 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-04-21 Cont ID  
Sent By btrobaug Date 2006-04-21 Time 13:29 Rev Time 0.50
Received By btrobaug Date 2006-04-21 Time 13:29 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2006-04-21 Cont ID  
Sent By btrobaug Date 2006-04-21 Time 13:30 Rev Time 0.30
Received By btrobaug Date 2006-04-07 Time 06:22 Sent To  
Notes
2006-04-07 00:00:00PUT IN REVIEW FOR P PETTYJL 4/6/06
  
 SEE NOTE THREE FROM FIRST REVIEW FOR
 MAIN AND GROUNDING ELECTRODE AT GUEST
 HOUSE.
  
 PHILLIP PETTY805-6742

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-22 Cont ID  
Sent By btrobaug Date 2006-03-22 Time 17:34 Rev Time 0.75
Received By btrobaug Date 2006-03-22 Time 17:07 Sent To PC
Notes
2006-03-22 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT A RISER DIAGRAM AND
 PANL SCHEDULES FOFR ALL PANELS.
  
 2} THE "POOL HOUSE" MUST COMPLY WITH
 225.31 DISCONNECTING MEANS AND 250.32
 GROUNDING. SHOW SAME ON RISER.
  
 3} SHOW LOCATION OF THE SERVICE
 EQUIPMENT.
  
 4} THE KITCHEN COUNTERTOP RECEPTACLES
 MUST COMPLY WITH 210.8(A)(6). GFI.
  
 5} THE BATH RECEPTACLES MUST COMPLY WITH
 210.8(A)(1)
  
 6} THE MASTER BATH MUST COMPLY WITH
 BASIN RECEPTACLE SPACING. SEE 210.52(D).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-21 Cont ID  
Sent By adarroug Date 2006-06-21 Time 10:31 Rev Time 0.00
Received By adarroug Date 2006-06-21 Time 10:31 Sent To E
Notes
2006-06-21 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-20 Cont ID  
Sent By adarroug Date 2006-04-20 Time 11:03 Rev Time 0.00
Received By adarroug Date 2006-04-20 Time 11:03 Sent To E
Notes
2006-04-20 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-30 Cont ID  
Sent By adarroug Date 2006-03-30 Time 15:31 Rev Time 0.00
Received By adarroug Date 2006-03-30 Time 15:31 Sent To E
Notes
2006-03-30 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-20 Cont ID  
Sent By btrobaug Date 2006-03-20 Time 17:30 Rev Time 0.00
Received By btrobaug Date 2006-03-07 Time 16:03 Sent To E
Notes
2006-03-07 00:00:00TO "E" BOX