Plan Review Stops For Permit 06021135 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-09-28 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-09-28 |
Time |
11:08 |
Sent To |
|
|
Notes |
2006-09-28 00:00:00 | STRUCTURAL DETAILS OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-01 |
Time |
16:23 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2006-08-01 |
Time |
16:23 |
Sent To |
|
|
Notes |
2006-08-01 00:00:00 | ENGINEER LETTER REC'D |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-19 |
Time |
10:39 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2006-05-19 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-02 |
Time |
08:13 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2006-05-02 |
Time |
08:10 |
Sent To |
|
|
Notes |
2006-05-02 00:00:00 | DENIED | | | | | | 2.PRODUCT APPROVALS REQUIRED FOR FLAT | | ROOF AND STRAPS AND TIE-DOWNS. | | | | 3.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 5.SUBMIT TWO SETS OF TRUSS DRAWINGS | | FOR REVIEW PER 2004 FBC R-802.10.1 | | SHALL BE SUBMITTED AND APPROVED PRIOR TO | | INSTALLATION. | | | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-03-29 |
Time |
11:01 |
Rev Time |
2.25 |
Received By |
alange |
Date |
2006-03-29 |
Time |
10:56 |
Sent To |
|
|
Notes |
2006-03-29 00:00:00 | DENIED | | | | | | 1.SUBMIT TWO COPIES OF ENERGY CALCS | | PER 2004 FBC AND SIGN FORM. | | | | 2.PRODUCT APPROVALS REQUIRED FOR FLAT | | ROOF AND STRAPS AND TIE-DOWNS. | | | | 3.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 4.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 5.SUBMIT TWO SETS OF TRUSS DRAWINGS | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | | | 6.A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | SHOW HOW PLANS WILL COMPLY WITH THE | | SECTION(S) SELECTED.2004 FBC EXISTING | | BUILDING 301.5 | | | | 7.ALL PLANS SUBMITTED AFTER OCTOBER, | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | FLORIDA BUILDING CODE. | | | | 8.ROOF TILE SHALL NOT BE INSTALL OVER | | AN EXISTING ROOF. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-16 |
Time |
12:14 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-03-16 |
Time |
11:13 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-11-20 |
Time |
16:51 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-11-20 |
Time |
15:58 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-11-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-11-14 |
Time |
13:52 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2006-11-14 |
Time |
12:12 |
Sent To |
PC |
|
Notes |
2006-11-14 13:52:15 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT. | | | | 1} THE APPARANT DISCONNECTS, MISMARKED PANEL"A" AND | | "B" ON THE RISER DIAGRAM,ARE NOT LOCATED ON THE PLAN. | | LOCATE SAME. PANELS "A & B" IN THE LAUNDRY ROOM ARE IN | | VIOLATION OF 225.32, LOCATION OF DISCONNECTS. | | | | 2} THE PANELS ON THE RISER DIAGRAM ARE NOT ALL | | DESIGNATED AND DO NOT CORRELATE WITHE THE PANEL | | SCHEDULES WHICH ARE NOT MARKED EITHER, EXCEPT TWO THAT | | ARE BOTH MARKED "A". PLEASE MARK ALL PANELS AND | | DISCONNECTS, SEE PERMIT SET. | | | | 3} CORRELATE THE DISCONNECT AND PANEL RATINGS ON THE | | RISER WITH THE SAME ON PANEL SCHEDULES. NOTE THATTHE | | PANELS MARKED "A" ARE LISTED AS 150 AMP. | | | | 4} THERE ARE NO EQUIPMENT GROUNDS, REQUIRED PER | | 250.122, RAN TO ANY PANELS FROM THE DISCONNECTS, EXCEPT | | THE GARAGE PANEL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-17 |
Time |
07:45 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-05-17 |
Time |
07:00 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-04-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-04-27 |
Time |
13:43 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-04-27 |
Time |
13:10 |
Sent To |
M |
|
Notes |
2006-04-27 00:00:00 | | | | | PLEASE SEE ARTICLE 225.31 AND 225.32 , | | 2002, NEC. WHICH READ AS FOLLOWS. | | | | 225.31 DISCONNECTING MEANS. | | MEANS SHALL BE PROVIDED FOR | | DISCONNECTING ALL UNGROUNDED CONDUCTORS | | THAT SUPPLY OR PASS THROUGH THE BUILDING | | OR STRUCTURE. | | 225.32 LOCATION. | | THE DISCONNECTING MEANS SHALL BE | | INSTALLED EITHER INSIDE OR OUTSIDE OF | | THE BUILDING OR STRUCTURE SERVED OR | | WHERE THE CONDUCTORS PASS THROUGH THE | | BUILDING OR STRUCTURE. THE DISCONNECTING | | MEANS SHALL BE AT A READILY ACCESSIBLE | | LOCATION NEAREST THE POINT OF ENTRANCE | | OF THE CONDUCTORS. FOR THE PURPOSES OF | | THIS SECTION, THE REQUIREMENTS IN 230.6 | | SHALL BE PERMITTED TO BE UTILIZED. | | | | ALSO SEE ARTICLE 250.32(A), TO DETERMINE | | HOW TO INSTALL A GROUNDING ELECTRODE AT | | THAT BUILDING, IN THIS CASE, THE MAIN | | HOUSE. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-03-14 |
Time |
12:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-03-14 |
Time |
11:41 |
Sent To |
M |
|
Notes |
2006-03-14 00:00:00 | | | FAILED | | | | | | 1} PLEASE LOCATE ALL THE SERVICE | | EQUIPMENT ON THE PLAN SO THAT COMPLIANCE | | WITH 225.31, 250.32 AND 110.26 CAN BE | | DETERMINED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2007-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-01 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-01 |
Time |
16:28 |
Sent To |
M |
|
Notes |
2007-05-01 16:29:08 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-25 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-25 |
Time |
13:13 |
Sent To |
M |
|
Notes |
2007-04-25 13:14:09 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-23 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-23 |
Time |
11:17 |
Sent To |
Z |
|
Notes |
2007-04-23 11:17:25 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
bpowell |
Date |
2007-04-16 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:25 |
Sent To |
Z |
|
Notes |
2007-04-03 17:25:59 | TO ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2007-03-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-15 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-15 |
Time |
09:58 |
Sent To |
E |
|
Notes |
2007-03-15 09:59:22 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-16 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-16 |
Time |
09:42 |
Sent To |
E |
|
Notes |
2006-11-16 09:42:43 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-09 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-09 |
Time |
17:47 |
Sent To |
E |
|
Notes |
2006-11-09 17:47:47 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-02 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-02 |
Time |
15:07 |
Sent To |
E |
|
Notes |
2006-11-02 15:07:42 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-02 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-02 |
Time |
14:58 |
Sent To |
M |
|
Notes |
2006-11-02 14:58:39 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-10-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-02 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-02 |
Time |
12:29 |
Sent To |
M |
|
Notes |
2006-10-02 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-09-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-11 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-11 |
Time |
10:00 |
Sent To |
B |
|
Notes |
2006-09-11 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-31 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-31 |
Time |
14:54 |
Sent To |
B |
|
Notes |
2006-07-31 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-15 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-15 |
Time |
10:07 |
Sent To |
E |
|
Notes |
2006-05-15 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-27 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-27 |
Time |
10:22 |
Sent To |
E |
|
Notes |
2006-04-27 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-17 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-17 |
Time |
11:45 |
Sent To |
Z |
|
Notes |
2006-04-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-13 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-13 |
Time |
10:00 |
Sent To |
E |
|
Notes |
2006-03-13 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-29 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-02-28 |
Time |
08:56 |
Sent To |
|
|
Notes |
2006-02-28 00:00:00 | TO ZONING. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
P |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-02 |
Time |
09:31 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-05-02 |
Time |
09:31 |
Sent To |
|
|
Notes |
2007-05-02 09:32:22 | REVISION TO ENERGY CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-25 |
Time |
16:12 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-04-25 |
Time |
16:12 |
Sent To |
|
|
Notes |
2007-04-25 16:22:24 | REVISION TO ENERGY CAL'S. | | *** DENIED *** | | 1) REVISED COOLING LOAD CALCULATIONS SHOW THAT THE A/C | | SYSTEMS ON THE MECHANICAL PLANS ARE TO LARGE, SEE 2001 | | FBC 13-607.1.ABC.1.1, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-19 |
Time |
11:45 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-03-19 |
Time |
11:45 |
Sent To |
|
|
Notes |
2007-03-19 11:46:00 | RE-STAMP. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-11-03 |
Time |
09:39 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-11-03 |
Time |
09:39 |
Sent To |
|
|
Notes |
2006-11-03 09:40:04 | REVISION TO MECHANICAL PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2006-10-10 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-10 |
Time |
08:45 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-10-10 |
Time |
08:45 |
Sent To |
|
|
Notes |
2006-10-10 08:59:52 | MECHANICAL REVISION | | *** DENIED *** | | | | 1) SEE MECHANICAL PLANS A/C SYSTEMS #2 | | AND #3 SENSIBLE BTU'S CAN NOT BE MORE | | THAN 20% OVER THE MANUAL J CALCULATIONS, | | SEE ATTACHED COPY OF MANUAL J CAL'S. | | PLEASE CORRECT OR SUBMIT REVISED MANUAL J | | CAL'S. PER 2004 FBC 13-607.1.ABC.1.1 . | | | | 2) RETURN AIR TRANSFER DUCTS TO AC #4 | | FROM THE FAMILY ROOM ARE TO SMALL, SEE | | NOTE # 5, PLEASE CORRECT. | | | | 3) A 10" RETURN AIR DUCT TO THE MASTER | | SUITEIS TO SMALL FOR A 12" SUPPLY AIR | | DUCT, ALL AIR TO THE MASTER SUITE MUST | | BE INCLUDED, SEE NOTE #5 (C) EXCEPT. | | PLEASE CORRECT. | | | | 4) TWO SUPPLY AIR DUCTS IN THE DEN ARE | | NOT SIZED, PLEASE CORRECT. | | | | 5) BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-17 |
Time |
11:09 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-05-17 |
Time |
11:10 |
Sent To |
B |
|
Notes |
2006-05-17 00:00:00 | *** PROVISO *** | | 1) PROVIDE COMBUSTION AIR FOR ALL GAS | | APPLIANCES AND REVISE MECHANICAL PLANS | | TO SHOW THIS, BEFOR ROUGH MECHANICAL | | INSPECTION. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-04-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-04-28 |
Time |
08:01 |
Rev Time |
1.00 |
Received By |
tgordon |
Date |
2006-04-28 |
Time |
08:01 |
Sent To |
P |
|
Notes |
2006-04-28 00:00:00 | *** DENIED *** | | 1) MANUAL J CALCULATIONS ARE CALLING FOR | | A TOTAL OF 25,892 SENSIBLE BTU'S, | | MECHANICAL PLANS ARE CALLING FOR A TOTAL | | OF 47,800 SENSIBLE BTU'S, THE PLANS CAN | | ONLY CALL FOR 20% MORE THAN THE MANUAL J | | CAL'S PLEASE CORRECT, PER 2004 FBC CH. | | 13, 607.1.ABC.1.1 . | | | | 2) PLEASE CORRECT THE FLOOR SIZE FOR | | ZONE 1 IN THE MANUAL J CAL'S. | | | | 3) A 12" RETURN AIR DUCT TO AHU #3 | | APPEARS TO SMALL BOR A 3 TON A/C SYSTEM, | | PLEASE CORRECT. | | | | 4)PLEASE SHOW THE SIZE OF THE R/A RIDGE | | DUCT IN A/C CLOSET #3. | | | | 5)RETURN AIR TRANSFER DUCT TO FAMILY | | ROOM IS UNDER SIZED, SEE NOTE #7. | | | | 6) AS REQUESTED 3-14-06 #7, RETURN AIR | | TRANSFER DUCT TO MASTER BEDROOM IS UNDER | | SIZED, SEE NOTE #7 (C) EXCEPT.. | | | | 7)BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-03-14 |
Time |
16:00 |
Rev Time |
1.00 |
Received By |
tgordon |
Date |
2006-03-14 |
Time |
16:00 |
Sent To |
P |
|
Notes |
2006-03-14 00:00:00 | *** DENIED *** | | 1) ARCHITECT'S LICENSE NUMBER MUST | | APPEAR IN THE TITLE BLOCK, PER FAC | | 61G1-16.004 . | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED | | BY OWNER/AGENT. | | | | 3) PLEASE SHOW TOTAL COOLING BTU'S. AND | | SENSIBLE COOLING BTU'S. ON MECHANICAL | | PLANS. | | | | 4) PLANS ARE SHOWING AN EXHUST FAN IN | | THE LAUNDRY ROOM WITH A GAS WATER | | HEATER, THIS WILL REMOVE THE COMBUSTION | | AIR FROM THE ROOM PLEASE CORRECT. | | | | 5) PLEASE SHOW THE SIZE OF THE RETURN | | AIR GRILL TO AHU #4. | | | | 6) RETURN AIR TRANSFER DUCTS TO THE DEN. | | AND PLAYROOM ARE UNDER SIZED, SEE NOTE | | #8 (A). | | | | 7) RETURN AIR TRANSFER DUCT TO THE | | MASTER SUITE IS TO SMALL, SEE NOTE #8 | | (A) AND (C) "EXCEPT". | | | | 8)BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-04-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-17 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-04-29 |
Time |
09:47 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-03-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-03-16 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-03-16 |
Time |
15:27 |
Sent To |
B |
|
Notes |
2006-03-16 00:00:00 | DENIED; | | SANITARY RISER DIAGRAM IS REQUIRED. | | PLEASE SIZE ALL PIPES. SEE FBC-2004 | | CHAPTER 1 ADMINISTRATION CODE. SEC. | | 106.3.5.4 (9). | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
Sent By |
bpowell |
Date |
2007-04-26 |
Time |
19:08 |
Rev Time |
0.00 |
Received By |
bpowell |
Date |
2007-04-26 |
Time |
19:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
bpowell |
Date |
2007-04-16 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
bpowell |
Date |
2007-04-16 |
Time |
09:10 |
Sent To |
|
|
Notes |
2007-04-16 09:14:05 | 1.NEW PLANS AND SURVEY SHALL BE SUBMITTED WITH | | REVISIONS INDICATING WHAT HAS BEEN REVISED. | | | | BOBBY POWELL, PLANNER, (561) 822-1435, [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-26 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-26 |
Time |
07:48 |
Sent To |
I |
|
Notes |
2006-04-26 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | WALL/FENCE/GATE/PIERS WITH EASEMENT | | APPROVAL FROM CITY OF WEST PALM BEACH | | UTILITY DEPT. | | *** THE MAX HEIGHT ALLOWED WITHIN THE | | FIRST 25FT FRONT SETBACK IS 4FT. BEYOND | | THE 25FT FRONT SETBACK 6FT ONLY. | | *** MUST PROVIDE TWO COPY OF SITEWALL | | FOR THE PROPOSED WALL/PIERS/GATE. | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | POOL/SPA/DECK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-03-10 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-03-10 |
Time |
11:13 |
Sent To |
I |
|
Notes |
2006-03-10 00:00:00 | DENIED, | | 1. THE FRONT SETBACK ON SITEPLAN & | | SURVEY DOES NOT MATCH. | | 2. MUST PULL A SEPERATE PERMIT FOR | | WALL/FENCE/GATE/PIERS WITH EASEMENT | | APPROVAL FROM CITY OF WEST PALM BEACH | | UTILITY DEPT. | | 3. THE MAX HEIGHT ALLOWED WITHIN THE | | FIRST 25FT FRONT SETBACK IS 4FT. BEYOND | | THE 25FT FRONT SETBACK 6FT ONLY. | | 4. MUST PROVIDE TWO COPY OF SITEWALL FOR | | FOR THE PROPOSED WALL/PIERS/GATE. | | 5. MUST PULL A SEPERATE PERMIT FOR | | POOL/SPA/DECK | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|