Plan Review Details - Permit 06021135
Plan Review Stops For Permit 06021135
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-09-28 Cont ID  
Sent By alange Date 2006-09-28 Time 11:08 Rev Time 0.00
Received By alange Date 2006-09-28 Time 11:08 Sent To  
Notes
2006-09-28 00:00:00STRUCTURAL DETAILS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-08-01 Cont ID  
Sent By alange Date 2006-08-01 Time 16:23 Rev Time 0.33
Received By alange Date 2006-08-01 Time 16:23 Sent To  
Notes
2006-08-01 00:00:00ENGINEER LETTER REC'D

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-19 Cont ID  
Sent By alange Date 2006-05-19 Time 10:39 Rev Time 1.00
Received By alange Date 2006-05-19 Time 09:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-02 Cont ID  
Sent By alange Date 2006-05-02 Time 08:13 Rev Time 1.00
Received By alange Date 2006-05-02 Time 08:10 Sent To  
Notes
2006-05-02 00:00:00DENIED
  
  
 2.PRODUCT APPROVALS REQUIRED FOR FLAT
 ROOF AND STRAPS AND TIE-DOWNS.
  
 3.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
 SHALL BE SUBMITTED AND APPROVED PRIOR TO
 INSTALLATION.
  
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-29 Cont ID  
Sent By alange Date 2006-03-29 Time 11:01 Rev Time 2.25
Received By alange Date 2006-03-29 Time 10:56 Sent To  
Notes
2006-03-29 00:00:00DENIED
  
  
 1.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC AND SIGN FORM.
  
 2.PRODUCT APPROVALS REQUIRED FOR FLAT
 ROOF AND STRAPS AND TIE-DOWNS.
  
 3.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 4.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 5.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
  
 6.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 7.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 8.ROOF TILE SHALL NOT BE INSTALL OVER
 AN EXISTING ROOF.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-03-16 Cont ID  
Sent By btrobaug Date 2007-03-16 Time 12:14 Rev Time 0.50
Received By btrobaug Date 2007-03-16 Time 11:13 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-20 Cont ID  
Sent By btrobaug Date 2006-11-20 Time 16:51 Rev Time 0.50
Received By btrobaug Date 2006-11-20 Time 15:58 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-11-14 Cont ID  
Sent By btrobaug Date 2006-11-14 Time 13:52 Rev Time 1.00
Received By btrobaug Date 2006-11-14 Time 12:12 Sent To PC
Notes
2006-11-14 13:52:15 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT.
  
 1} THE APPARANT DISCONNECTS, MISMARKED PANEL"A" AND
 "B" ON THE RISER DIAGRAM,ARE NOT LOCATED ON THE PLAN.
 LOCATE SAME. PANELS "A & B" IN THE LAUNDRY ROOM ARE IN
 VIOLATION OF 225.32, LOCATION OF DISCONNECTS.
  
 2} THE PANELS ON THE RISER DIAGRAM ARE NOT ALL
 DESIGNATED AND DO NOT CORRELATE WITHE THE PANEL
 SCHEDULES WHICH ARE NOT MARKED EITHER, EXCEPT TWO THAT
 ARE BOTH MARKED "A". PLEASE MARK ALL PANELS AND
 DISCONNECTS, SEE PERMIT SET.
  
 3} CORRELATE THE DISCONNECT AND PANEL RATINGS ON THE
 RISER WITH THE SAME ON PANEL SCHEDULES. NOTE THATTHE
 PANELS MARKED "A" ARE LISTED AS 150 AMP.
  
 4} THERE ARE NO EQUIPMENT GROUNDS, REQUIRED PER
 250.122, RAN TO ANY PANELS FROM THE DISCONNECTS, EXCEPT
 THE GARAGE PANEL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-05-17 Cont ID  
Sent By btrobaug Date 2006-05-17 Time 07:45 Rev Time 0.50
Received By btrobaug Date 2006-05-17 Time 07:00 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-04-27 Cont ID  
Sent By btrobaug Date 2006-04-27 Time 13:43 Rev Time 0.50
Received By btrobaug Date 2006-04-27 Time 13:10 Sent To M
Notes
2006-04-27 00:00:00 
  
 PLEASE SEE ARTICLE 225.31 AND 225.32 ,
 2002, NEC. WHICH READ AS FOLLOWS.
  
 225.31 DISCONNECTING MEANS.
 MEANS SHALL BE PROVIDED FOR
 DISCONNECTING ALL UNGROUNDED CONDUCTORS
 THAT SUPPLY OR PASS THROUGH THE BUILDING
 OR STRUCTURE.
 225.32 LOCATION.
 THE DISCONNECTING MEANS SHALL BE
 INSTALLED EITHER INSIDE OR OUTSIDE OF
 THE BUILDING OR STRUCTURE SERVED OR
 WHERE THE CONDUCTORS PASS THROUGH THE
 BUILDING OR STRUCTURE. THE DISCONNECTING
 MEANS SHALL BE AT A READILY ACCESSIBLE
 LOCATION NEAREST THE POINT OF ENTRANCE
 OF THE CONDUCTORS. FOR THE PURPOSES OF
 THIS SECTION, THE REQUIREMENTS IN 230.6
 SHALL BE PERMITTED TO BE UTILIZED.
  
 ALSO SEE ARTICLE 250.32(A), TO DETERMINE
 HOW TO INSTALL A GROUNDING ELECTRODE AT
 THAT BUILDING, IN THIS CASE, THE MAIN
 HOUSE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-14 Cont ID  
Sent By btrobaug Date 2006-03-14 Time 12:01 Rev Time 0.50
Received By btrobaug Date 2006-03-14 Time 11:41 Sent To M
Notes
2006-03-14 00:00:00 
 FAILED
  
  
 1} PLEASE LOCATE ALL THE SERVICE
 EQUIPMENT ON THE PLAN SO THAT COMPLIANCE
 WITH 225.31, 250.32 AND 110.26 CAN BE
 DETERMINED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-05-01 Cont ID  
Sent By adarroug Date 2007-05-01 Time 16:28 Rev Time 0.00
Received By adarroug Date 2007-05-01 Time 16:28 Sent To M
Notes
2007-05-01 16:29:08TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-04-25 Cont ID  
Sent By adarroug Date 2007-04-25 Time 13:13 Rev Time 0.00
Received By adarroug Date 2007-04-25 Time 13:13 Sent To M
Notes
2007-04-25 13:14:09TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-04-23 Cont ID  
Sent By adarroug Date 2007-04-23 Time 11:17 Rev Time 0.00
Received By adarroug Date 2007-04-23 Time 11:17 Sent To Z
Notes
2007-04-23 11:17:25TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-04-03 Cont ID  
Sent By bpowell Date 2007-04-16 Time 09:14 Rev Time 0.00
Received By spalmer Date 2007-04-03 Time 17:25 Sent To Z
Notes
2007-04-03 17:25:59TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-03-15 Cont ID  
Sent By adarroug Date 2007-03-15 Time 09:58 Rev Time 0.00
Received By adarroug Date 2007-03-15 Time 09:58 Sent To E
Notes
2007-03-15 09:59:22TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-11-16 Cont ID  
Sent By adarroug Date 2006-11-16 Time 09:42 Rev Time 0.00
Received By adarroug Date 2006-11-16 Time 09:42 Sent To E
Notes
2006-11-16 09:42:43TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-11-09 Cont ID  
Sent By adarroug Date 2006-11-09 Time 17:47 Rev Time 0.00
Received By adarroug Date 2006-11-09 Time 17:47 Sent To E
Notes
2006-11-09 17:47:47TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 15:09 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 15:07 Sent To E
Notes
2006-11-02 15:07:42TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 15:02 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 14:58 Sent To M
Notes
2006-11-02 14:58:39TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-10-02 Cont ID  
Sent By adarroug Date 2006-10-02 Time 12:29 Rev Time 0.00
Received By adarroug Date 2006-10-02 Time 12:29 Sent To M
Notes
2006-10-02 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-09-11 Cont ID  
Sent By adarroug Date 2006-09-11 Time 10:00 Rev Time 0.00
Received By adarroug Date 2006-09-11 Time 10:00 Sent To B
Notes
2006-09-11 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-31 Cont ID  
Sent By adarroug Date 2006-07-31 Time 14:54 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 14:54 Sent To B
Notes
2006-07-31 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-15 Cont ID  
Sent By adarroug Date 2006-05-15 Time 10:07 Rev Time 0.00
Received By adarroug Date 2006-05-15 Time 10:07 Sent To E
Notes
2006-05-15 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 10:22 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 10:22 Sent To E
Notes
2006-04-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-17 Cont ID  
Sent By adarroug Date 2006-04-17 Time 11:45 Rev Time 0.00
Received By adarroug Date 2006-04-17 Time 11:45 Sent To Z
Notes
2006-04-17 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-13 Cont ID  
Sent By adarroug Date 2006-03-13 Time 10:00 Rev Time 0.00
Received By adarroug Date 2006-03-13 Time 10:00 Sent To E
Notes
2006-03-13 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-29 Cont ID  
Sent By dpalmer Date 2006-03-29 Time 10:56 Rev Time 0.00
Received By alange Date 2006-02-28 Time 08:56 Sent To  
Notes
2006-02-28 00:00:00TO ZONING.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2007-05-02 Cont ID  
Sent By tgordon Date 2007-05-02 Time 09:31 Rev Time 0.20
Received By tgordon Date 2007-05-02 Time 09:31 Sent To  
Notes
2007-05-02 09:32:22REVISION TO ENERGY CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2007-04-25 Cont ID  
Sent By tgordon Date 2007-04-25 Time 16:12 Rev Time 0.30
Received By tgordon Date 2007-04-25 Time 16:12 Sent To  
Notes
2007-04-25 16:22:24REVISION TO ENERGY CAL'S.
 *** DENIED ***
 1) REVISED COOLING LOAD CALCULATIONS SHOW THAT THE A/C
 SYSTEMS ON THE MECHANICAL PLANS ARE TO LARGE, SEE 2001
 FBC 13-607.1.ABC.1.1, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-03-19 Cont ID  
Sent By tgordon Date 2007-03-19 Time 11:45 Rev Time 0.20
Received By tgordon Date 2007-03-19 Time 11:45 Sent To  
Notes
2007-03-19 11:46:00RE-STAMP.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2006-11-03 Cont ID  
Sent By tgordon Date 2006-11-03 Time 09:39 Rev Time 0.30
Received By tgordon Date 2006-11-03 Time 09:39 Sent To  
Notes
2006-11-03 09:40:04REVISION TO MECHANICAL PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2006-10-10 Cont ID  
Sent By tgordon Date 2006-10-10 Time 08:45 Rev Time 0.45
Received By tgordon Date 2006-10-10 Time 08:45 Sent To  
Notes
2006-10-10 08:59:52MECHANICAL REVISION
 *** DENIED ***
  
 1) SEE MECHANICAL PLANS A/C SYSTEMS #2
 AND #3 SENSIBLE BTU'S CAN NOT BE MORE
 THAN 20% OVER THE MANUAL J CALCULATIONS,
 SEE ATTACHED COPY OF MANUAL J CAL'S.
 PLEASE CORRECT OR SUBMIT REVISED MANUAL J
 CAL'S. PER 2004 FBC 13-607.1.ABC.1.1 .
  
 2) RETURN AIR TRANSFER DUCTS TO AC #4
 FROM THE FAMILY ROOM ARE TO SMALL, SEE
 NOTE # 5, PLEASE CORRECT.
  
 3) A 10" RETURN AIR DUCT TO THE MASTER
 SUITEIS TO SMALL FOR A 12" SUPPLY AIR
 DUCT, ALL AIR TO THE MASTER SUITE MUST
 BE INCLUDED, SEE NOTE #5 (C) EXCEPT.
 PLEASE CORRECT.
  
 4) TWO SUPPLY AIR DUCTS IN THE DEN ARE
 NOT SIZED, PLEASE CORRECT.
  
 5) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-05-17 Cont ID  
Sent By tgordon Date 2006-05-17 Time 11:09 Rev Time 0.45
Received By tgordon Date 2006-05-17 Time 11:10 Sent To B
Notes
2006-05-17 00:00:00*** PROVISO ***
 1) PROVIDE COMBUSTION AIR FOR ALL GAS
 APPLIANCES AND REVISE MECHANICAL PLANS
 TO SHOW THIS, BEFOR ROUGH MECHANICAL
 INSPECTION.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-04-28 Cont ID  
Sent By tgordon Date 2006-04-28 Time 08:01 Rev Time 1.00
Received By tgordon Date 2006-04-28 Time 08:01 Sent To P
Notes
2006-04-28 00:00:00*** DENIED ***
 1) MANUAL J CALCULATIONS ARE CALLING FOR
 A TOTAL OF 25,892 SENSIBLE BTU'S,
 MECHANICAL PLANS ARE CALLING FOR A TOTAL
 OF 47,800 SENSIBLE BTU'S, THE PLANS CAN
 ONLY CALL FOR 20% MORE THAN THE MANUAL J
 CAL'S PLEASE CORRECT, PER 2004 FBC CH.
 13, 607.1.ABC.1.1 .
  
 2) PLEASE CORRECT THE FLOOR SIZE FOR
 ZONE 1 IN THE MANUAL J CAL'S.
  
 3) A 12" RETURN AIR DUCT TO AHU #3
 APPEARS TO SMALL BOR A 3 TON A/C SYSTEM,
 PLEASE CORRECT.
  
 4)PLEASE SHOW THE SIZE OF THE R/A RIDGE
 DUCT IN A/C CLOSET #3.
  
 5)RETURN AIR TRANSFER DUCT TO FAMILY
 ROOM IS UNDER SIZED, SEE NOTE #7.
  
 6) AS REQUESTED 3-14-06 #7, RETURN AIR
 TRANSFER DUCT TO MASTER BEDROOM IS UNDER
 SIZED, SEE NOTE #7 (C) EXCEPT..
  
 7)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-14 Cont ID  
Sent By tgordon Date 2006-03-14 Time 16:00 Rev Time 1.00
Received By tgordon Date 2006-03-14 Time 16:00 Sent To P
Notes
2006-03-14 00:00:00*** DENIED ***
 1) ARCHITECT'S LICENSE NUMBER MUST
 APPEAR IN THE TITLE BLOCK, PER FAC
 61G1-16.004 .
  
 2) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT.
  
 3) PLEASE SHOW TOTAL COOLING BTU'S. AND
 SENSIBLE COOLING BTU'S. ON MECHANICAL
 PLANS.
  
 4) PLANS ARE SHOWING AN EXHUST FAN IN
 THE LAUNDRY ROOM WITH A GAS WATER
 HEATER, THIS WILL REMOVE THE COMBUSTION
 AIR FROM THE ROOM PLEASE CORRECT.
  
 5) PLEASE SHOW THE SIZE OF THE RETURN
 AIR GRILL TO AHU #4.
  
 6) RETURN AIR TRANSFER DUCTS TO THE DEN.
 AND PLAYROOM ARE UNDER SIZED, SEE NOTE
 #8 (A).
  
 7) RETURN AIR TRANSFER DUCT TO THE
 MASTER SUITE IS TO SMALL, SEE NOTE #8
 (A) AND (C) "EXCEPT".
  
 8)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-04-29 Cont ID  
Sent By tgordon Date 2006-05-17 Time 11:10 Rev Time 0.00
Received By jleech Date 2006-04-29 Time 09:47 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-16 Cont ID  
Sent By jleech Date 2006-03-16 Time 15:27 Rev Time 0.00
Received By jleech Date 2006-03-16 Time 15:27 Sent To B
Notes
2006-03-16 00:00:00DENIED;
 SANITARY RISER DIAGRAM IS REQUIRED.
 PLEASE SIZE ALL PIPES. SEE FBC-2004
 CHAPTER 1 ADMINISTRATION CODE. SEC.
 106.3.5.4 (9).
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  
  

Review Stop Z ZONING
Rev No 4 Status P Date 2007-04-26 Cont ID  
Sent By bpowell Date 2007-04-26 Time 19:08 Rev Time 0.00
Received By bpowell Date 2007-04-26 Time 19:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2007-04-16 Cont ID  
Sent By bpowell Date 2007-04-16 Time 09:17 Rev Time 0.00
Received By bpowell Date 2007-04-16 Time 09:10 Sent To  
Notes
2007-04-16 09:14:051.NEW PLANS AND SURVEY SHALL BE SUBMITTED WITH
 REVISIONS INDICATING WHAT HAS BEEN REVISED.
  
 BOBBY POWELL, PLANNER, (561) 822-1435, [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2006-04-26 Cont ID  
Sent By mmclean Date 2006-04-26 Time 07:48 Rev Time 0.00
Received By mmclean Date 2006-04-26 Time 07:48 Sent To I
Notes
2006-04-26 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 WALL/FENCE/GATE/PIERS WITH EASEMENT
 APPROVAL FROM CITY OF WEST PALM BEACH
 UTILITY DEPT.
 *** THE MAX HEIGHT ALLOWED WITHIN THE
 FIRST 25FT FRONT SETBACK IS 4FT. BEYOND
 THE 25FT FRONT SETBACK 6FT ONLY.
 *** MUST PROVIDE TWO COPY OF SITEWALL
 FOR THE PROPOSED WALL/PIERS/GATE.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-16 Cont ID  
Sent By mmclean Date 2006-03-10 Time 14:18 Rev Time 0.00
Received By mmclean Date 2006-03-10 Time 11:13 Sent To I
Notes
2006-03-10 00:00:00DENIED,
 1. THE FRONT SETBACK ON SITEPLAN &
 SURVEY DOES NOT MATCH.
 2. MUST PULL A SEPERATE PERMIT FOR
 WALL/FENCE/GATE/PIERS WITH EASEMENT
 APPROVAL FROM CITY OF WEST PALM BEACH
 UTILITY DEPT.
 3. THE MAX HEIGHT ALLOWED WITHIN THE
 FIRST 25FT FRONT SETBACK IS 4FT. BEYOND
 THE 25FT FRONT SETBACK 6FT ONLY.
 4. MUST PROVIDE TWO COPY OF SITEWALL FOR
 FOR THE PROPOSED WALL/PIERS/GATE.
 5. MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720