Plan Review Details - Permit 06020598
Plan Review Stops For Permit 06020598 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-09-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-09-20 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-09-20 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-07-07 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-07-07 |
Time |
11:15 |
Sent To |
|
|
Notes |
2006-07-07 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | FROM PREVIOUS REVIEWS, SAME PAPERWORK | | SUBMITTED: | | | | _XX_2.PROVIDE BUILDING HEIGHT. | | DESIGN PRESSURES FOR BUILDINGS OVER | | 60FEET ARE REQUIRED TO BE DESIGNED USING | | ASCE7, FBC1609.1.1. DOCUMENTS PREPARED | | BY AN ENGINEER AND SUBMITTED FOR PUBLIC | | RECORD ARE TO BE SIGNED SEALED ORIGINALS | | FAC61G15-23.002. | | | | SECOND REVIEW - SOME OF THE PAPERWORK | | YOU SUBMITTED STILL GIVES A MRH OF 15'. | | DUE TO THE CONFUSION AND DISCREPANCIES | | ON SOME OF YOUR JOBS IN REGARDS TO | | BUILDING HEIGHT, HAVE AN ENGINEER OR | | ARCHITECT CERTIFY THIS BUILDING'S | | HEIGHT. | | | | THIRD REVIEW - THE DESIGN PRESSURES | | PRODUCED BY THE ENGINEERING SOFTWARE | | SHOWS A MRH OF 120', THE HANDWRITTEN | | SCHEDULE GIVES MRH AS 15'.THE DESIGN | | PRESSURES AND BUILDING HEIGHT ARE TO BE | | CERTIFIED BY AN ENGINEER. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-05-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-05-06 |
Time |
19:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-05-06 |
Time |
19:02 |
Sent To |
|
|
Notes |
2006-05-06 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | FROM PREVIOUS REVIEW: | | | | _XX_2.PROVIDE BUILDING HEIGHT. | | DESIGN PRESSURES FOR BUILDINGS OVER | | 60FEET ARE REQUIRED TO BE DESIGNED USING | | ASCE7, FBC1609.1.1. DOCUMENTS PREPARED | | BY AN ENGINEER AND SUBMITTED FOR PUBLIC | | RECORD ARE TO BE SIGNED SEALED ORIGINALS | | FAC61G15-23.002. | | | | SECOND REVIEW - SOME OF THE PAPERWORK | | YOU SUBMITTED STILL GIVES A MRH OF 15'. | | DUE TO THE CONFUSION AND DISCREPANCIES | | ON SOME OF YOUR JOBS IN REGARDS TO | | BUILDING HEIGHT, HAVE AN ENGINEER OR | | ARCHITECT CERTIFY THIS BUILDING'S | | HEIGHT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-03-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-03-02 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-03-02 |
Time |
14:26 |
Sent To |
|
|
Notes |
2006-03-02 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED | | ITEMS APPLY | | | | _XX_1.A NOTICE OF COMMENCEMENT MUST | | BE FILED WITH THE CLERK OF COURTS BEFORE | | A PERMIT CAN BE ISSUED, FS713.13. | | | | _XX_2.PROVIDE BUILDING HEIGHT. | | DESIGN PRESSURES FOR BUILDINGS OVER | | 60FEET ARE REQUIRED TO BE DESIGNED USING | | ASCE7, FBC1609.1.1. DOCUMENTS PREPARED | | BY AN ENGINEER AND SUBMITTED FOR PUBLIC | | RECORD ARE TO BE SIGNED SEALED ORIGINALS | | FAC61G15-23.002. | | | | _XX_3.PROVIDE A COPY OF THE CONDO | | ASSOCIATION APPROVAL. | | | | _XX_4.COMPLETE THE ATTACHED | | INSTALLATION SCHEDULE OR PROVIDE | | REQUIRED INFORMATION IN A SIMILAR | | FORMAT. | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT | | APPROVAL REQUIRED, FAC9B72, | | WWW.FLORIDABUILDING.ORG. | | | | _XX_6.ON THE PRODUCT APPROVAL, MARK | | WHICH DETAILS APPLY TO THIS JOB.PLEASE | | USE INK RATHER THAN A HIGHLIGHTER. | | | | ____7.SHOW THE EMERGENCY MEANS OF | | ESCAPE, FBC R310. | | | | _XX_8.PROVIDE A FLOOR PLAN SHOWING | | WHERE THE SHUTTERS WILL BE INSTALLED | | WHICH CORRELATES WITH THE INSTALLATION | | SCHEDULE, ITEM 4 ABOVE. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-19 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-19 |
Time |
17:13 |
Sent To |
B |
|
Notes |
2006-09-19 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-25 |
Time |
18:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-25 |
Time |
18:00 |
Sent To |
B |
|
Notes |
2006-06-25 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-05 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-05 |
Time |
13:25 |
Sent To |
B |
|
Notes |
2006-05-05 00:00:00 | TO "SHILL "DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-03-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-03-02 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-02-15 |
Time |
18:32 |
Sent To |
|
|
Notes |
2006-02-15 00:00:00 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy