Plan Review Details - Permit 06020317
Plan Review Stops For Permit 06020317
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-09-28 Cont ID  
Sent By alange Date 2006-09-28 Time 14:07 Rev Time 1.00
Received By alange Date 2006-09-28 Time 14:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-08-18 Cont ID  
Sent By alange Date 2006-08-18 Time 12:56 Rev Time 1.25
Received By alange Date 2006-08-18 Time 11:30 Sent To Z
Notes
2006-08-18 00:00:00DENIED
  
  
 1.713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 3.ADJUST PERMIT VALUE TO REFLECT ALL
 MATERIALS AND LABOR AND PAY ADDITIONAL
 PERMIT FEES.
  
 4.SIGN OWNER/AGENT ON ENERGY CALCS PER
 2004 FBC.
  
 5.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THE FOLLOWING, INSWING
 DOOR, STRAPS AND TIE-DOWNS.
  
 6.JELD-WEN DOOR AND STRAPS AND
 TIE-DOWNS MISSING THE FOLLOWING STATE
 PRODUCT APPROVAL,POMA SHUTTER ON FILE
 HERE OK.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.PRODUCT
 APPROVALS NOT LISTED ON LETTER.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
  
 A.PROTECTION AGAINST DECAYR319
 2.ALL WOOD FRAMING MEMBERS THAT
 REST ON CONCRETE OR MASONRY EXTERIOR
 FOUNDATION WALLS AND ARE LESS THAN 8
 INCHES FROM THE EXPOSED GROUND.
 3.SILLS AND SLEEPERS ON A CONCRETE
 OR MASONRY SLAB THAT IS IN DIRECT
 CONTACT WITH THE GROUND UNLESS SEPARATED
 FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE
 BARRIER.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING
 HAVING A CLEARANCE OF LESS THAN 6 INCHES
 FROM THE GROUND.
 6.WOOD STRUCTURAL MEMBERS
 SUPPORTING MOISTURE-PERMEABLE FLOORS OR
 ROOFS THAT ARE EXPOSED TO THE WEATHER,
 SUCH AS CONCRETE OR MASONRY SLABS,
 UNLESS SEPARATED FROM SUCH FLOORS OR
 ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-15 Cont ID  
Sent By alange Date 2006-06-15 Time 13:19 Rev Time 1.50
Received By alange Date 2006-06-15 Time 13:19 Sent To  
Notes
2006-06-15 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO $.
 ADDITIONAL PERMIT FEES ARE DUE.
  
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THE FOLLOWING, DOORS,
 STRAPS AND TIE-DOWNS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 NEW COMMENT:
 A.PROTECTION AGAINST DECAYR319
 1.WOOD JOISTS OR THE BOTTOM OF A
 WOOD STRUCTURAL FLOOR WHEN CLOSER THAN
 18 INCHES OR WOOD GIRDERS WHEN CLOSER
 THAN 12 INCHES TO THE EXPOSED GROUND IN
 CRAWL SPACES OR UNEXCAVATED AREA LOCATED
 WITHIN THE PERIPHERY OF THE BUILDING
 FOUNDATION.
 2.ALL WOOD FRAMING MEMBERS THAT
 REST ON CONCRETE OR MASONRY EXTERIOR
 FOUNDATION WALLS AND ARE LESS THAN 8
 INCHES FROM THE EXPOSED GROUND.
 3.SILLS AND SLEEPERS ON A CONCRETE
 OR MASONRY SLAB THAT IS IN DIRECT
 CONTACT WITH THE GROUND UNLESS SEPARATED
 FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE
 BARRIER.
 4.THE ENDS OF WOOD GIRDERS ENTERING
 EXTERIOR MASONRY OR CONCRETE WALLS
 HAVING CLEARANCES OF LESS THAN 0.5 INCH
 (12.7 MM) ON TOPS, SIDES AND ENDS.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING
 HAVING A CLEARANCE OF LESS THAN 6 INCHES
 (152 MM) FROM THE GROUND.
 6.WOOD STRUCTURAL MEMBERS
 SUPPORTING MOISTURE-PERMEABLE FLOORS OR
 ROOFS THAT ARE EXPOSED TO THE WEATHER,
 SUCH AS CONCRETE OR MASONRY SLABS,
 UNLESS SEPARATED FROM SUCH FLOORS OR
 ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 NOTE; NEW COMMENTS MAY ARISE AFTER NEW
 PLANS HAVE BEEN SUBMITTED.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-27 Cont ID  
Sent By alange Date 2006-03-27 Time 09:37 Rev Time 3.00
Received By alange Date 2006-03-27 Time 09:37 Sent To  
Notes
2006-03-27 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO $.
 ADDITIONAL PERMIT FEES ARE DUE.
  
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THE FOLLOWING, DOORS,
 WINDOWS, STRAPS AND TIE-DOWNS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE
 PERMITTED TO BE SUBMITTED WHEN APPROVED
 BY THE BUILDING OFFICIAL. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE BUILDING OFFICIAL
 (SEE ALSO SECTION 106.3.5).
  
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 10.CLEARLY SHOW EXISTING AREAS ON
 PLANS, NEW WORK, FLOOR PLANS,
 ELEVATIONS,FRAMING DETAILS,
 CONSTRUCTION MATERIALS USED (WOD OR
 MASONARY), SHOW ROOM USE ON PLANS.FBC
 106.3.5 WPB AMMENDMENTS
  
 11.SHOW FINISH FLOOR ELEVATION ON
 PLANS.IS THIS SLAB AT GRADE?
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 NOTE; NEW COMMENTS MAY ARISE AFTER NEW
 PLANS HAVE BEEN SUBMITTED.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-09-21 Cont ID  
Sent By btrobaug Date 2006-09-21 Time 06:56 Rev Time 0.50
Received By btrobaug Date 2006-09-21 Time 06:19 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-16 Cont ID  
Sent By btrobaug Date 2006-08-16 Time 06:53 Rev Time 0.50
Received By btrobaug Date 2006-08-16 Time 06:38 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-06-14 Cont ID  
Sent By btrobaug Date 2006-06-14 Time 07:37 Rev Time 0.33
Received By btrobaug Date 2006-06-14 Time 07:36 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-17 Cont ID  
Sent By btrobaug Date 2006-02-17 Time 15:26 Rev Time 0.33
Received By btrobaug Date 2006-02-17 Time 15:20 Sent To P
Notes
2006-02-17 00:00:00 
 PLEASE SUBMIT PLANS INDICATING
 COMPLIANCE WITH 2004 RESIDENTIAL
 BUILDING CODE AND THE 2002 NEC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-09-20 Cont ID  
Sent By adarroug Date 2006-09-20 Time 14:16 Rev Time 0.00
Received By adarroug Date 2006-09-20 Time 14:16 Sent To E
Notes
2006-09-20 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-09-11 Cont ID  
Sent By adarroug Date 2006-09-11 Time 09:55 Rev Time 0.00
Received By adarroug Date 2006-09-11 Time 09:55 Sent To Z
Notes
2006-09-11 00:00:00TO "Z" BOX/RESUB--SHEETS STAMPED FOR
 "ZONING", BUT FAILED IN SYSTEM

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-09 Cont ID  
Sent By adarroug Date 2006-08-09 Time 15:22 Rev Time 0.00
Received By adarroug Date 2006-08-09 Time 15:22 Sent To E
Notes
2006-08-09 00:00:00TO "BTROBAUG" DESK/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-12 Cont ID  
Sent By adarroug Date 2006-06-12 Time 10:12 Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 10:12 Sent To E
Notes
2006-06-12 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-01 Cont ID  
Sent By adarroug Date 2006-06-01 Time 11:57 Rev Time 0.00
Received By adarroug Date 2006-06-01 Time 11:57 Sent To Z
Notes
2006-06-01 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-16 Cont ID  
Sent By adarroug Date 2006-02-16 Time 09:19 Rev Time 0.00
Received By adarroug Date 2006-02-16 Time 09:19 Sent To E
Notes
2006-02-16 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-27 Cont ID  
Sent By alange Date 2006-03-27 Time 09:48 Rev Time 0.00
Received By alange Date 2006-02-09 Time 16:24 Sent To  
Notes
2006-02-09 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-02-21 Cont ID  
Sent By tgordon Date 2006-02-21 Time 13:49 Rev Time 0.15
Received By tgordon Date 2006-02-21 Time 13:49 Sent To B
Notes
2006-02-21 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-09-21 Cont ID  
Sent By mperson Date 2006-09-21 Time 14:00 Rev Time 0.33
Received By mperson Date 2006-09-21 Time 14:00 Sent To B
Notes
2006-09-21 00:00:00NEW SHEETS

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-08-18 Cont ID  
Sent By mperson Date 2006-08-18 Time 09:21 Rev Time 0.33
Received By mperson Date 2006-08-18 Time 09:21 Sent To B
Notes
2006-08-18 00:00:00NOTE: NEW SHEETS NO PLUMBING CHANGES

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-06-15 Cont ID  
Sent By mperson Date 2006-06-15 Time 09:02 Rev Time 0.33
Received By mperson Date 2006-06-15 Time 09:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By mperson Date 2006-02-21 Time 09:20 Rev Time 1.00
Received By mperson Date 2006-02-21 Time 09:20 Sent To M
Notes
2006-02-21 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW:
  
 1. RESIDENTIAL (ONE AND TWO FAMILY)
 PER 601.3.5.4, SUBMIT A PLUMBING
 SANITARY ISOMETRIC RISER DIAGRAM
 INDICATING ALL WASTE, VENTS, AND TRAPS
 WITH SIZES.
 2. SECTION 405 INSTALLATION OF FIXTURES
 405.3.1 WATER CLOSETS, LAVATORIES SHALL
 NOT BE SET CLOSER THAN 15" FROM ITS
 CENTER TO ANY SIDE WALL.(NOTE: FINISHED
 SIDE WALL OR SHOWER STALL WALL) WATER
 CLOSET COMPARTMENTS SHALL NOT BE LESS
 THAN 30" WIDE. THERE SHALL BE AT LEAST
 21" CLEARENCE IN FRONT OF LAVATORY OR
 WATER CLOSET TO ANY WALL, FIXTURE OR
 DOOR.
 417.4 SHOWER COMPARTMENTS. ALL SHOWER
 COMPARTMENTS SHALL HAVE A MINIMUM OF 900
 SQUARE INCHES OF INTERIOR
 CROSS-SECTIONAL AREA. SHOWER
 COMPARTMENTS SHALL NOT BE LESS THAN 30
 INCHES IN MINIMUM DIMENSION MEASURED
 FROM THE FINISHED INTERIOR DIMENSION OF
 THE COMPARTMENT.
 (NOTE: THE ABOVE MEASUREMENTS NEED TO BE
 INDICATED ON DRAWING. THE 5 FOOT INSIDE
 TO INSIDE MEASUREMENT ON YOUR DRAWING
 WILL NOT MEET MINIMUM REQUIREMENTS
 PLEASE REWORK MEASUREMENTS TO COMPLY
 WITH MINIMUM STANDARDS.)
 3. SECTION 917 AIR ADMITTANCE VALVES.
 PLEASE CORRECT DRAWING FROM STUDIO VENT
 TO AIR ADMITTANCE VALVE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561)805-6721

Review Stop Z ZONING
Rev No 4 Status P Date 2006-09-18 Cont ID  
Sent By mmclean Date 2006-09-18 Time 14:24 Rev Time 0.00
Received By mmclean Date 2006-09-15 Time 17:18 Sent To I
Notes
2006-09-18 00:00:00NOTE: ENCLOSING THE EXISTING CARPORT.

Review Stop Z ZONING
Rev No 3 Status F Date 2006-08-18 Cont ID  
Sent By mmclean Date 2006-08-18 Time 13:32 Rev Time 0.00
Received By mmclean Date 2006-08-18 Time 13:32 Sent To I
Notes
2006-08-18 00:00:00DENIED,
 1. THE PROPOSED WALL FOR THE NEW
 ADDITION MUST HAVE INTERIOR ACCESS FROM
 THE EXISTING LAUNDRY ROOM TO BATHROOM.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-10 Cont ID  
Sent By mmclean Date 2006-06-10 Time 11:33 Rev Time 0.00
Received By mmclean Date 2006-06-10 Time 11:33 Sent To I
Notes
2006-06-10 00:00:00NOTE: ENCLOSE EXISTING CARPORT.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-15 Cont ID  
Sent By mmclean Date 2006-02-15 Time 16:14 Rev Time 0.00
Received By mmclean Date 2006-02-15 Time 16:14 Sent To I
Notes
2006-02-15 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE PROPOSED WORK WITH
 SETBACKS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy