Plan Review Details - Permit 06011287
Plan Review Stops For Permit 06011287
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-30 Cont ID  
Sent By amorse Date 2006-05-30 Time 11:33 Rev Time 2.00
Received By amorse Date 2006-05-30 Time 11:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-22 Cont ID  
Sent By amorse Date 2006-03-22 Time 11:35 Rev Time 4.00
Received By amorse Date 2006-03-22 Time 11:35 Sent To PC
Notes
2006-03-22 00:00:00 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 3) PLANS WERE SUBMITTED AFTER JAN.1,
 2004 AND AS SUCH THE ENGINEER'S SEAL
 WAS MANDATED TO CHANGE IN APPEARANCE PER
 61G15-23.001 FAC
  
 4) PROVIDE DRAWING OF EXISTING LAYOUT
 WITH AJOINING ROOMS FOR BETTER
 UNDERSTANDING OF ADDITION OR MOVING OF
 EXISTING STRUCTURE AND SYSTEMS SUCH AS
 PLUMBING, MECHANICAL AND ELEC.
  
 5) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 CONFORM WITH R802.10.1 FBC
  
 6) DRAWING S/1 SPECIFIES REMOVAL OF WALL
 BELOW TIE BEAM, DOES PARALLAM BEAM
 REPLACE TIE BEAM? PLEASE CLARIFY
  
 7) DRAWING S/3 DETAIL 1 SHOWS TRUSS
 TAILS, WILL THEY BE REMOVED? ALSO IS
 TRIPLE JACK POST TO RUN ALLTHE WAY TO
 PARALLAM BEAM FOR BEARING WITHOUT DOUBLE
 TOP PLATE BECAUSE THERE IS NO WALL
 UNDERNEATH. CLARIFY ON DRAWINGS
  
 8) DRAWING S/2 SHOWS AN EXISTING BEAM TO
 REMAIN, IF BEAM IS IN CEILING WHAT IS
 RELATIONSHIP TO NEW TRUSS GIRDER AND
 ATTACHMENT TO NEW PARALLAM BEAM?
  
 9) ELEVATION DRAWING SHALL PROVIDE
 FIN.FL. EL, BEAM EL, AND MEAN ROOF HT.
  
 10) SUBMIT SOIL REPORT, MAY USE COPY OF
 EXISTING PER
  
 11) SUBMIT A SOIL REPORT PER 1802.1-
 1802.2.2 FBC
  
 12) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
  
 IS RELEVANT. THESE SHOULD INCLUDE THE
 FLORIDA STATE APPROVAL COVER PAGES, AND
 THE PRODUCT NOA THAT LISTS THE SYSTEM
 COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM
 TO BE USED AND THE GENERAL LIMITATIONS
 PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 13) PLEASE SEE JELD-WEN DOORS (THE FIRST
 4 PAGES IS THE STATE APPROVAL COVER
 SHEETS). THESE ARE REQUIRED FOR THE
 SHINGLES ALONG WITH THE UPDATED NOA, THE
 STORM PANELS AND WINDOWS ARE OK AS IS
  
 14) PROVIDE PRODUCT APPROVAL FOR FLAT
 AREA OF THE ROOF AS SHINGLES ARE NOT
 PERMITTED ON ROOF SLOPES LESS THAN 2/12
  
 15) THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 WPB
 AMENDMENTS TO FBC 2004
  
 16) STRUCTURAL NOTES ON S/3 UPDATE NOTES
 TO 2004. WIND LOADS ARE NOW 1609
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH
 ADMINISTATIVE AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-23 Cont ID  
Sent By btrobaug Date 2006-05-23 Time 17:32 Rev Time 0.33
Received By btrobaug Date 2006-05-23 Time 13:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-13 Cont ID  
Sent By btrobaug Date 2006-02-13 Time 12:15 Rev Time 0.50
Received By btrobaug Date 2006-02-13 Time 12:07 Sent To P
Notes
2006-02-13 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} SEE 210.8(A)(7) FOR GFI REQUIREMENTS
 AT WET BAR.
  
 2} THE ENGINEER OF RECORD MUST SIGN AND
 SEAL THE PLAN PER 471 FS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 15:57 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 15:57 Sent To E
Notes
2006-05-22 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-05 Cont ID  
Sent By adarroug Date 2006-05-05 Time 13:07 Rev Time 0.00
Received By adarroug Date 2006-05-05 Time 13:07 Sent To Z
Notes
2006-05-05 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-10 Cont ID  
Sent By adarroug Date 2006-02-10 Time 14:58 Rev Time 0.00
Received By adarroug Date 2006-02-10 Time 14:58 Sent To E
Notes
2006-02-10 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-22 Cont ID  
Sent By amorse Date 2006-03-22 Time 11:36 Rev Time 0.00
Received By amorse Date 2006-02-02 Time 17:28 Sent To  
Notes
2006-02-02 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2006-05-25 Cont ID  
Sent By tgordon Date 2006-05-25 Time 14:45 Rev Time 0.15
Received By tgordon Date 2006-05-25 Time 14:45 Sent To  
Notes
2006-05-25 00:00:00CUSTOMER HAD MECHANICAL PERMIT 06011289
 VOIDED. NO MECHANICAL PLANS SUBMITTED.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-05-24 Cont ID  
Sent By tgordon Date 2006-05-24 Time 11:40 Rev Time 0.30
Received By tgordon Date 2006-05-24 Time 11:40 Sent To B
Notes
2006-05-24 00:00:00*** DENIED ***
 1) AS NOTED IN LAST REVIEW 2-16-06.
 NO MECHANICAL PLANS WERE SUBMITTED FOR
 REVIEW. PLEASE SUBMIT MECHANICAL PLANS
 FOR REVIEW, OR YOU MAY WISH TO VOID YOUR
 MECHANICAL PERMIT NUMBER 06011289 SO
 YOUR BUILDING PLANS MAY BY-PASS A
 MECHANICAL REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-16 Cont ID  
Sent By tgordon Date 2006-02-16 Time 11:26 Rev Time 0.20
Received By tgordon Date 2006-02-16 Time 11:26 Sent To B
Notes
2006-02-16 00:00:00*** DENIED ***
 1) MECHANICAL PERMIT SIGNED ON, BUT NO
 MECHANICAL PLANS SUBMITTED FOR REVIEW
 (PLEASE SUBMIT MECHANICAL PLANS).
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-24 Cont ID  
Sent By mperson Date 2006-05-24 Time 10:46 Rev Time 0.33
Received By mperson Date 2006-05-24 Time 10:46 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-16 Cont ID  
Sent By btrobaug Date 2006-02-13 Time 12:37 Rev Time 1.00
Received By mperson Date 2006-02-16 Time 08:29 Sent To M
Notes
2006-02-16 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW.
  
 1. RESIDENTIAL (ONE AND TWO FAMILY)
 PER 601.3.5.4 SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, AND TRAPS WITH SIZES. ALSO
 INDICATE ON DRAWING WHERE NEW ISLAND
 SINK TIES INTO EXISTING SANITARY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDERSUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 2 Status P Date 2006-05-22 Cont ID  
Sent By mmclean Date 2006-05-22 Time 09:12 Rev Time 0.00
Received By mmclean Date 2006-05-22 Time 09:12 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-09 Cont ID  
Sent By mmclean Date 2006-02-09 Time 17:56 Rev Time 0.00
Received By mmclean Date 2006-02-09 Time 17:56 Sent To I
Notes
2006-02-09 00:00:00DENIED,
 1. MUST PROVIDE TWO COMPLETE FLOOR PLAN,
 SHOWING THE PROPOSED (WITH INTERIOR
 ACCESS) TO THE EXISTING STRUCTURE. ALL
 ROOMS MUST BE IDENTIFIED.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720