Plan Review Stops For Permit 06011138 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-25 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-08-25 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-16 |
Time |
16:34 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-02-16 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-24 |
Time |
08:41 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-08-24 |
Time |
07:52 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-09 |
Time |
11:03 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-02-09 |
Time |
09:58 |
Sent To |
M |
|
Notes |
2006-02-09 00:00:00 | | | THE VALUE ON THE APPLICATION MUST | | REFLECT THE TOTAL VALUE OF LABOR AND | | MATERIAL PER 108.3 FBC.( COST OF | | GENERATOR ,ATS,SLAB, ETC.) | | | | | | 1}INDICATE FEEDER FROM PANEL "N" TO ATS | | IN PANEL "N" SCHEDULE. THIS IS TO | | PREVENT AN INADVERTENT POWER UP OF THE | | GENERATOR PANEL, CURRENTLY LABLED "L", | | WHILE ATTEMTING TO DE-ENERGISE IT WITH | | THE BREAKER, AND RE ENERGIZING IT WITH | | THE GENERATOR. | | | | 2} SHOW PANEL "S" ON THE RISER PER 215.5 | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-15 |
Time |
14:40 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-02-15 |
Time |
14:40 |
Sent To |
B |
|
Notes |
2006-02-15 00:00:00 | NOTE: SEPERATE PLANS AND PERMIT REQUIRED | | FOR GAS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-22 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-22 |
Time |
14:55 |
Sent To |
E |
|
Notes |
2006-08-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-12 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-12 |
Time |
14:14 |
Sent To |
Z |
|
Notes |
2006-08-12 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-02 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-02 |
Time |
15:16 |
Sent To |
E |
|
Notes |
2006-02-02 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-02-16 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-31 |
Time |
13:59 |
Sent To |
|
|
Notes |
2006-01-31 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-24 |
Time |
09:10 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-08-24 |
Time |
09:10 |
Sent To |
B |
|
Notes |
2006-08-24 00:00:00 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURE'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING, AND PROVIDE MANUFACTURE'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-02-13 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-02-13 |
Time |
15:16 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-02-13 |
Time |
15:16 |
Sent To |
P |
|
Notes |
2006-02-13 00:00:00 | *** PROVISO *** | | 1)GENERATOR EXHUST MUST BE TEN FEET AWAY | | FROM ANY BUILDING OPENINGS (WINDOWS, | | DOORS, ROOF & EAVE VENTS), AND TEN FEET | | AWAY FROM ADJECENT BUILDING OPENS. PER | | 2004 FBC/M 401.5.1 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-15 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-02-15 |
Time |
14:39 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-08-19 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-19 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-19 |
Time |
06:59 |
Sent To |
I |
|
Notes |
2006-08-19 00:00:00 | DENIED, | | 1. THE FOOTPRINT OF THE SURVEY & PARTIAL | | SITEPLAN DOES NOT MATCH. | | 2. PLEASE PROVIDE AND UPDATED SURVEY | | SHOWING THE CORRECTED FOOTPRINT OF THE | | EXISTING STRUCTURE (SHOWING ANY ADDITION | | THAT CHANGED THE FOOTPRINT TO WHAT THE | | SURVEY IS SHOWING DATED 10/10/90 | | 3. THE SITEPLAN MUST SHOW ALL THAT | | LOCATED ON THE PROPERTY AND MUST BE A | | FULL SIZE SITEPLAN WITH DIMENSION OF THE | | COMPLETE PROPERTY WITH SETBACKS OF THE | | STRUCTURE (FRONT/SIDE/REAR) | | 4. THE SITEPLAN SUBMITTED CANNOT BE USED | | A REVIEW FOR THE PROPOSED WORK AND THE | | SURVEY SUBMITTED IS NOT A CURRENT SURVEY | | (10/10/90) | | | | NOTE: SEC 94-303 MECHANICAL/POOL | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | THAN FOUR FEET INTO A SETBACK. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-02-02 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-02-02 |
Time |
13:19 |
Sent To |
I |
|
Notes |
2006-02-02 00:00:00 | DENIED, | | 1. NEED TO PROVIDE A COMPLETE SURVEY OR | | SITEPLAN WITH DIMENSION OF LOT WITH | | SETBACKS AND ADDRESS OF PROPERTY. | | 2. MUST INDICATE THE SETBACK OF THE | | GENERATOR FROM PROPERTY LINE. | | 3. SITEPLAN (PARTIAL) DOES NOT PROVIDE | | INFORMATION NEEDED TO COMPLETE ZONING | | REVIEW. | | | | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | INTO A SETBACK (CANNOT ENCROACH ON | | PROPERTY LINE). | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|