Plan Review Details - Permit 06010683
Plan Review Stops For Permit 06010683
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-03-27 Cont ID  
Sent By mjacobs Date 2006-03-27 Time 09:23 Rev Time 0.00
Received By mjacobs Date 2006-03-24 Time 16:51 Sent To PC
Notes
2006-03-27 00:00:00 
  
 PROVISO
 PRODUCT APPROVAL FOR HURRICANE
 PROTECTION IS REQUIRED BEFORE CO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-10 Cont ID  
Sent By mjacobs Date 2006-02-10 Time 10:02 Rev Time 2.50
Received By mjacobs Date 2006-02-09 Time 14:49 Sent To PC
Notes
2006-02-09 00:00:001) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE. NOTE: THE NOTICE OF COMMENCEMENT
 MUST BE RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2) THERE IS NO GARAGE DOOR ON THIS
 STRUCTURE SO,WHY IS IT CALL A
 GARAGE/STUDIO? IF THE STRUCTURE WILL NOT
 BE USED AS A GARAGE, CHANGE THE
 DESCRIPTION ON THE APPLICATION TO MATCH
 THE USE AND OCCUPANCY OF THE BUILDING.
  
 3) PRODUCT APPROVALS WITH THE STATE
 COVER SHEET AND FL# ARE NEEDED FOR EACH
 PRODUCT INCLUDING THE ROOFING
 MATERIALS/DOORS AND WINDOWS/LINTELS ETC.
 THOSE PRODUCTS WHICH ARE GEGULATED BY
 DCA RULE 9B72 SHALL BE REVIEW AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 (W.P.B.AMENDMENTS) 106.3.3
  
 4) THE LUS28 SIMPSON HANGER IS TOO SHORT
 TO ACCOMIDATE A 2X12. I SUGGEST THAT YOU
 SPEAK WITH SIMPSON STRONG TIE AND GET
 THEIR ADVISE AS TO WHICH HANGE SHOULD BE
 USED.
  
 5) 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.CONSTRUCTION DOCUMENTS SHALL
 BE DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE
 BUILDING OFFICIAL (SEE ALSO SECTION
 106.3.5).
  
 6) 106.1.1.2 FOR ROOF ASSEMBLIES
 REQUIRED BY THE CODE, THE CONSTRUCTION
 DOCUMENTS SHALL ILLUSTRATE, DESCRIBE,
 AND DELINEATE THE TYPE OF ROOFING
 SYSTEM, MATERIALS, FASTENING
 REQUIREMENTS, FLASHING REQUIREMENTS AND
 WIND RESISTANCE RATING THAT ARE REQUIRED
 TO BE INSTALLED.PRODUCT EVALUATION AND
 INSTALLATION SHALL INDICATE COMPLIANCE
 WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN
 ARCHITECT OR ENGINEER FOR THE SPECIFIC
 SITE MUST BE SUBMITTED WITH THE
 CONSTRUCTION DOCUMENTS.ALSO SEE ROOFING
 PROCEDURE IN PACKAGE.
  
 7) NOTE: THE WIND LOAD SECTION IN THE
 FBC IS 1609 NOT 1606. CHANGE NOTES TO
 REFLECT THE CORRECT SECTION.
  
 8)A SITE PLAN IS REQUIRED SHOWING THE
 EXACT OUTLINE,SIZE AND LOCATION OF
 PROPOSED ADDITION AND EXISTING BUILDINGS
 AND SHOW DISTANCE TO PROPERTY LINES.ETC.
 SITE DRAWINGS. DRAWINGS SHALL SHOW THE
 LOCATION OF ALL NEW WORK, INCLUDING THE
 PROPOSED BUILDING OR STRUCTURE, AND OF
 ALL EXISTING MAN-MADE IMPROVEMENTS AND
 EVERY EXISTING SURVEY, OR OTHER SPECIAL
 SURVEY, PREPARED BY A QUALIFIED
 SURVEYOR. IF REQUIRED, SURVEYS SHALL BE
 PREPARED IN ACCORDANCE WITH PROVISIONS
 OF CHAPTERS 177 AND 472 FLORIDA
 STATUTES, AND RULE 61G17, FLORIDA
 ADMINISTRATIVE CODE. (W.P.B AMENDMENTS
 SEC.106.3.4)
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-23 Time 15:44 Rev Time 0.33
Received By btrobaug Date 2006-03-23 Time 18:05 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-01-30 Cont ID  
Sent By btrobaug Date 2006-01-30 Time 14:32 Rev Time 0.50
Received By btrobaug Date 2006-01-30 Time 12:36 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 15:25 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 15:25 Sent To E
Notes
2006-03-23 00:00:00TO BT'S DESK, NEW ELECTRICAL SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-04 Cont ID  
Sent By adarroug Date 2006-03-04 Time 17:09 Rev Time 0.00
Received By adarroug Date 2006-03-04 Time 17:09 Sent To Z
Notes
2006-03-04 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-24 Cont ID  
Sent By adarroug Date 2006-01-24 Time 08:29 Rev Time 0.00
Received By adarroug Date 2006-01-24 Time 08:29 Sent To E
Notes
2006-01-24 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-02-10 Time   Rev Time 0.00
Received By adarroug Date 2006-01-19 Time 11:54 Sent To  
Notes
2006-01-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-02-02 Cont ID  
Sent By tgordon Date 2006-02-02 Time 16:37 Rev Time 0.15
Received By tgordon Date 2006-02-02 Time 16:37 Sent To B
Notes
2006-02-02 00:00:00NO MECH. PLANS OR MECH. CONTRACTOR
 SUBMITTED AT THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-03-24 Cont ID  
Sent By jleech Date 2006-03-24 Time 14:33 Rev Time 0.00
Received By jleech Date 2006-03-24 Time 14:33 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-02 Cont ID  
Sent By jleech Date 2006-02-02 Time 10:23 Rev Time 0.50
Received By jleech Date 2006-02-02 Time 10:23 Sent To M
Notes
2006-02-02 00:00:00DENIED;
 MINUMUM CLEARANCE FOR W/C IS 30" FROM
 SHOWER TO WALL. THE MINUMUM FOR A SHOWER
 IS 30" X 30" OR 900 SQ. INCH. SEE
 FBC-2004 PLUMBING SEC. 405.3.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-03-22 Cont ID  
Sent By mmclean Date 2006-03-22 Time 14:39 Rev Time 0.00
Received By mmclean Date 2006-03-22 Time 14:39 Sent To I
Notes
2006-03-22 00:00:00NOTE: THE GARAGE/STUDIO MUST BE A
 MINIMUM OF 6FT FROM MAIN STRUCTURE. SF14

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-23 Cont ID  
Sent By mmclean Date 2006-01-23 Time 16:49 Rev Time 0.00
Received By mmclean Date 2006-01-20 Time 07:51 Sent To I
Notes
2006-01-20 00:00:00DENIED, NEED SURVEY SHOWING LOCATION OF
 GARAGE/STUDIO