Plan Review Details - Permit 06010599
Plan Review Stops For Permit 06010599
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-02-24 Cont ID  
Sent By amorse Date 2006-02-24 Time 15:45 Rev Time 0.75
Received By amorse Date 2006-02-24 Time 15:45 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-09 Cont ID  
Sent By amorse Date 2006-02-09 Time 09:29 Rev Time 1.00
Received By amorse Date 2006-02-09 Time 09:29 Sent To PC
Notes
2006-02-09 00:00:00 
  
 DENIED
  
 1) VERIFY MEETING RAIL ON WINDOW JOB
 DISCRIPTION CALLS FOR STANDARD MEETING
 RAIL, PRODUCT APPROVALS ARE FOR HEAVY
 DUTY MEETING RAIL. STANDARD MEETING RAIL
 WILL NOT REACH DESIGN PRESSURES UNLESS
 TEMPERED GLASS IS USED, HEAVY DUTY RAIL
 WILL MEET THE DESIGN PRESSURES WITH
 STANDARD 3/16" ANNEALED GLASS
  
 2) CONTRACTOR SHALL VERIFY THAT WINDOW
 IS A REPLACEMENT ONLY AND NO
 MODIFICATION TO BUILDING STRUCTURE WILL
 TAKE PLACE
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-13 Cont ID  
Sent By adarroug Date 2006-02-13 Time 10:33 Rev Time 0.00
Received By adarroug Date 2006-02-13 Time 10:33 Sent To B
Notes
2006-02-13 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-09 Cont ID  
Sent By amorse Date 2006-02-09 Time 09:30 Rev Time 0.00
Received By amorse Date 2006-01-19 Time 09:41 Sent To  
Notes
2006-01-19 00:00:00TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy