Plan Review Details - Permit 06010507
Plan Review Stops For Permit 06010507
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-10-03 Cont ID  
Sent By amorse Date 2006-10-03 Time 14:26 Rev Time 0.00
Received By amorse Date 2006-10-03 Time 14:26 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-14 Cont ID  
Sent By amorse Date 2006-07-14 Time 14:52 Rev Time 0.00
Received By amorse Date 2006-07-14 Time 14:52 Sent To PC
Notes
2006-07-14 00:00:00 
  
 DENIED
  
 1) NO WHITE OUT PERMITTED ON DRAWINGS
 PLEASE MAKE CORRECTIONS TO OTHER REVIEWS
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-14 Cont ID  
Sent By amorse Date 2006-03-14 Time 07:55 Rev Time 0.00
Received By amorse Date 2006-03-14 Time 07:55 Sent To PC
Notes
2006-03-14 00:00:00 
  
  
  
 DENIED
  
  
  
 1) PERMIT VALUATION IS LOW, VALUATION
 HAS BEEN ADJUSTED TO THE AVERAGE
 CONSTRUCTION COSTS AS SET OUT BY ICC PER
 108.3 FBC*
  
 2) CORRECT THE FOLLOWING INFORMATION ON
 DRAWINGS,
 A) UPDATEWIND DESIGN CRITERIA TO
 NEW STANDARD
 B) BUILDING TYPE
 C) CONCRETE STRENGTH ON FOUNDATION
 NOTES AND GENERAL NOTES DIFFER
 D) FASTENERS DIFFER ON GARAGE DOOR BUCK
 DETAIL AND FASTENER SCHEDULE
 E) ADDRESS ON SITE PLAN A/4 IS LAKE
 WORTH
  
 3) SHOW DRAINAGE ON SITE PLANS PER
 R401.3 FBC
  
 4) PROVIDE SOIL REPORT PER R401.4 FBC
 AND ARCHITECTS GENERAL NOTES #7
  
 5) FOUNDATION #3 SHALL BE A MINIMUM OF
 12" BELOW GRADE PER R403.1.4 FBC SHOW ON
 DETAIL H/2
  
 6) BEDROOM WINDOWS DO NOT MEET
 EMERGENCY EGRESS REQUIREMENTS PER R310.1
 - R310.1.4 FBC SHOW COMPLIANCE
  
 7) DOORS, WALLS, AND CEILING BETWEEN
 GARAGE AND DWELLING SHALL MEET THE
 REQUIREMENTS OF SECTION R309 FBC
  
 8) SPECIFY BEAM/LINTEL LENGTH AND THAT
 THEY COMPLY WITH 2104.1.5 FBC
  
 9) INSULATION IS REQUIRED BETWEEN
 GARAGE AND DWELLING (WALLS AND CEILING)
 PROVIDE DETAIL OR NOTES
  
 10) SUBMIT TRUSS DRAWINGS FOR ROOF AND
 2ND FLOOR PER106.1.1.2 FBC* AND
 R802.10.1
  
 11) THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 12) PROVIDE CERTIFICATION LETTER FROM
 ATRIUM WINDOWS THAT WIND LOADS WILL BE
 MET FOR SH WINDOWS
  
 13) PROVIDE A KEY PLAN AND INSTALLATION
 SCHEDULE SIMILAR TO ATTACHED SAMPLE ALSO
 SHOW ATTACHMENT TYPE, ETC. ON PRODUCT
 APPROVALS
  
 14) RADON FEES SHALL BE COLLECTED FOR
 THE STATE OF FLORIDA PER CHAPTER 10D-91
 FAC
  
 15) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO A
 PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH
 ADMINISTATIVE AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-17 Cont ID  
Sent By dpalmer Date 2006-09-17 Time 12:18 Rev Time 0.00
Received By dpalmer Date 2006-09-17 Time 12:10 Sent To M
Notes
2006-09-17 00:00:00** REDLINED,
  
 ALL BEDRMS WHICH INDICATE LT/FAN FOR
 "FUTURE" MUST AHVE SOME SORT OF LT
 FIXTURE INSTALLED FOR CO AT A MIN.
 10.70, LS 101 7.8

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By dpalmer Date 2006-07-05 Time 07:50 Rev Time 0.00
Received By dpalmer Date 2006-07-05 Time 07:15 Sent To M
Notes
2006-07-05 00:00:00**** UNSAT ****
  
  
  
 **
 1) NOTE: PLEASE SEE THE ELECTRICAL PAGE
 CONTAINS "WHITE-OUT" AND HAND DRAWN
 CHANGES. PLEASE KNOW, IN NO CASE CAN
 "WHITE OUT" BE USED ON PLANS. HAND DRAWN
 CHANGES MAY BE DONE BY A DESIGNER OF
 RECORD, HOWEVER EACH AND EVERY HAND
 WRITTEN DETAIL OR CHANGED WOULD BE
 REQUIRED TO BE SIGNED/INITIALED AND
 DATED.
 PLEASE REPRINT SHEETS ALONG WITH ANY
 COMMENTS FROM ANY OTHER TRADES AND SIGN,
 DATED AND SEAL PLANS.
 FS 481.221.
  
 2) NOTE: PLEASE SEE BUILDING REVIEW
 ADJUSTED THE VALUE FOR SCOPE PF WORK,
 HOWEVER THE FEES WERE NOT PAID. THESE
 FEES ARE REQUIRED TO BE PAID.
 FBC ADMIN SECT 108.3
  
 3) NOTE: ONE SET/COPY OF THE OLD/VOIDED
 SHEETS WERE NOTSUBMITTED FOR
 REFERENCE?
 PLEASE SEE THESE PLANS ARENOWMISSING
 THE AIC RATING OF THE SERVICE EQUIPMENT.
 PLEASE REVISE AND INDICATE THIS.
 110.9/215.5
  
 4) NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM MAIN DISCONNECT
 TO THE SUB PANEL.
 250.110.250.24B,250.122
 THIS WAS NOTED ON PREVIOUS REVIEW TO
 INCLUDE.
  
 **PLEASE REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 FOR REVIEW STAMPING.
 ONE SET OF THE OLD/VOIDED REMOVED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-08 Cont ID  
Sent By dpalmer Date 2006-02-08 Time 18:37 Rev Time 0.00
Received By dpalmer Date 2006-02-08 Time 18:21 Sent To M
Notes
2006-02-08 00:00:00********* UNSAT ***********
  
 1)NOTE: PLEASE SEE DESIGN AND PLANS MAKE
 REFERENCE TO THE 2001 FBC. PLEASE SEE
 BLDG COMMENTS AS THE 2004 FBC WAS
 ADOPTED OCT 1ST, 2005
  
 2)NOTE: PLEASE SEE PLANS WERE REQUIRED
 TO BE SUBMITTED FOR PERMIT BEFORE THE
 JAN 12TH, 2006 DEADLINE FOR PALM BEACH
 COUNTY IMPACT FEE INCREASE. PLEASE SEE
 BLDG REVIEW COMMENTS AS PLANS WERE NOT
 SUBMITTED FOR PERMIT UNTIL 2/6/06 AND
 MAY REQUIRE ADDITIONAL FEES BY PBC.
  
 3)NOTE: PLEASE ALSO SEE BLDG REVIEW
 COMMENTS AS VALUE FOR THIS TWO-STORY
 DWELLING SEEMS LOW FOR SCOPE OF WORK.
 PLEASE SEE FBC 108.3 , VALUATION IS
 BASED ON ALL LABOR AND MATERIALS.
 VALUE TO BE ADJUSTED.
  
 4)NOTE: PLEASE CORRELATE PANEL SCHEDULE,
 WITH RISER AND PLANS. ONE SHOWS 200A AND
 THE OTHER LOCATIONS INDICATE PANEL AS
 150A'S?
 215.5
  
 5)NOTE: PLEASE INCLUDE ALL FEEDERS FROM
 MAIN DISCONNECT TO SUB PANEL.
 PLEASESHOW EQUIPMENT GROUNDING
 CONDUCTOR.
 310.16,240.4, 310.15B6, 250.110, 250.122
 ETC
  
 6)NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52. REDLINED ON ONE SET.
  
 ** PLEASE REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 PLEASE SUBMIT ONE COPY OF OLD/VOIDED
 SHEETS FOR REFERENCE ONLY.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-05-17 Cont ID  
Sent By adarroug Date 2007-05-17 Time 13:43 Rev Time 0.00
Received By adarroug Date 2007-05-17 Time 13:43 Sent To M
Notes
2007-05-17 13:44:02TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-09-14 Cont ID  
Sent By adarroug Date 2006-09-14 Time 13:30 Rev Time 0.00
Received By adarroug Date 2006-09-14 Time 13:30 Sent To E
Notes
2006-09-14 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-08 Cont ID  
Sent By adarroug Date 2006-09-08 Time 18:09 Rev Time 0.00
Received By adarroug Date 2006-09-08 Time 18:09 Sent To Z
Notes
2006-09-08 00:00:00TO "Z" BOX/RESUB--"Z" SHEET VOIDED

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-03 Cont ID  
Sent By adarroug Date 2006-07-03 Time 13:36 Rev Time 0.00
Received By adarroug Date 2006-07-03 Time 13:36 Sent To E
Notes
2006-07-03 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-23 Cont ID  
Sent By adarroug Date 2006-06-23 Time 15:06 Rev Time 0.00
Received By adarroug Date 2006-06-23 Time 15:06 Sent To Z
Notes
2006-06-23 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-14 Cont ID  
Sent By amorse Date 2006-03-14 Time 07:55 Rev Time 0.00
Received By amorse Date 2006-02-07 Time 16:10 Sent To  
Notes
2006-02-07 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-05-18 Cont ID  
Sent By tgordon Date 2007-05-18 Time 09:09 Rev Time 0.20
Received By tgordon Date 2007-05-18 Time 09:09 Sent To  
Notes
2007-05-18 09:10:12MECH. REVISION TO PLANS PAGE A3.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-09-18 Cont ID  
Sent By tgordon Date 2006-09-18 Time 09:05 Rev Time 0.30
Received By tgordon Date 2006-09-18 Time 09:04 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By tgordon Date 2006-07-05 Time 09:33 Rev Time 0.30
Received By tgordon Date 2006-07-05 Time 09:33 Sent To P
Notes
2006-07-05 00:00:00*** DENIED ***
 1) PLEASE SEE ELECTRICAL REVIEW NOTE #1
 (NO WHITE OUT) AND CORRECT.
  
 2) MASTER BEDROOM 14" RETURN AIR
 TRANSFER DUCT NEEDS TO BE 16" SEE NOTE
 #3 (A) AND (C) MASTER SUITE.
  
 3) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-09 Cont ID  
Sent By tgordon Date 2006-02-09 Time 13:41 Rev Time 0.35
Received By tgordon Date 2006-02-09 Time 13:41 Sent To B
Notes
2006-02-09 00:00:00*** DENIED ***
 1) SENSIBLE BTU'S AND TOTAL BTU'S ON
 MECHANICAL PLANS EQUIP. LIST & MANUAL J
 EQUIP. LIST DO NOT MATCH PLEASE CORRECT.
  
 2) CFM'S ON MANUAL J PER ROOM, AND
 MECHANICAL PLANS LAY OUT PER ROOM DO NOT
 MATCH, (SOME SUPPLY AIR DUCTS APPEAR TO
 BE TO LARGE) PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-10-03 Cont ID  
Sent By mperson Date 2006-10-03 Time 11:33 Rev Time 0.33
Received By mperson Date 2006-10-03 Time 11:33 Sent To B
Notes
2006-10-03 00:00:00 
  
  
 **********PROVISO**********
 PER FBC-2004, PLUMBING, SECTION 802.4
 STANDPIPES: AUTOMATIC CLOTHES WASHERS
 SHALL BE INSTALLED WITH A STANDPIPE THAT
 SHALL EXTEND A MINIMUM OF 18" AND A
 MAXIMUM OF 42" ABOVE THE TRAP WEIR.

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-14 Cont ID  
Sent By jleech Date 2006-07-14 Time 07:08 Rev Time 0.00
Received By jleech Date 2006-07-14 Time 07:08 Sent To B
Notes
2006-07-14 00:00:00DENIED;
 1. SEE ELECTRICAL PLAN REVIEW'S NOTE
 ONE.
 2.WATER HEATER DETAIL; SHOW HEATER PAN
 UNDER WATER HEATER WITH A 3/4" DRAIN TO
 THE OUTSIDE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-09 Cont ID  
Sent By jleech Date 2006-02-09 Time 07:20 Rev Time 0.33
Received By jleech Date 2006-02-09 Time 07:20 Sent To M
Notes
2006-02-09 00:00:00DENIED;
 1.PAN REQUIRED FOR WATER HEATER WITH
 3/4" DRAIN PIPE TO OUTSIDE. SEEFBC-2004
 RESIDENTIAL SEC. P2801.5, P2801.5.1 AND
 P2801.5.2.
 2.SANITARY RISER DIAGRAM, THE WASHER AND
 KITCHEN SINK BRANCH DRAINS ARE REQUIRED
 TO DISCHARGE DOWN STREAM OF THE VENT FOR
 THE 1/2 BATH. FBC-2004 RESIDENTIAL SEC.
 P3108.
 3.AUTOMATIC CLOTHES WASHER CLEANOUT TO
 BE 48" AFF. PLEASE AND NOTE TO RISER
 DIAGRAM.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2006-09-12 Cont ID  
Sent By mmclean Date 2006-09-12 Time 14:42 Rev Time 0.00
Received By mmclean Date 2006-09-12 Time 14:42 Sent To I
Notes
2006-09-12 00:00:00NOTE:
 THE PROPOSED A/C SHALL NOT BE CLOSER
 THAN 1.5FT FROM REAR PROPERTY LINE.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-29 Cont ID  
Sent By mmclean Date 2006-06-29 Time 14:29 Rev Time 0.00
Received By mmclean Date 2006-06-29 Time 14:29 Sent To I
Notes
2006-06-29 00:00:00NOTE:
 THE PROPOSED A/C SHALL NOT BE CLOSER
 THAN 1.5FT FROM REAR PROPERTY LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-08 Cont ID  
Sent By mmclean Date 2006-02-08 Time 16:39 Rev Time 0.00
Received By mmclean Date 2006-02-08 Time 16:39 Sent To E
Notes
2006-02-08 00:00:00DENIED,
 1. NEED TO PROVIDE THE DIMENSION OF THE
 PROPOSED DRIVEWAY & WALKWAY (LENGTH &
 WIDTH).
  
 NOTE: MUST MAINTAIN 1000SQ OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720