Plan Review Details - Permit 06010506
Plan Review Stops For Permit 06010506
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-12-09 Cont ID  
Sent By rmcdouga Date 2010-12-09 Time 10:57 Rev Time 0.00
Received By rmcdouga Date 2010-12-09 Time 10:57 Sent To  
Notes
2010-12-09 10:58:50RESTAMP PLANS FOR PERMIT EXTENSION

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-10-04 Cont ID  
Sent By amorse Date 2006-10-04 Time 09:37 Rev Time 0.00
Received By amorse Date 2006-10-04 Time 09:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-14 Cont ID  
Sent By amorse Date 2006-07-14 Time 14:26 Rev Time 0.00
Received By amorse Date 2006-07-14 Time 14:25 Sent To PC
Notes
2006-07-14 00:00:00 
  
 DENIED
  
 1) NO WHITE OUT PERMITTED ON DRAWINGS
 PLEASE MAKE CORRECTIONS TO OTHER REVIEWS
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-13 Cont ID  
Sent By amorse Date 2006-03-13 Time 16:11 Rev Time 0.00
Received By amorse Date 2006-03-13 Time 16:11 Sent To PC
Notes
2006-03-13 00:00:00 
  
  
 DENIED
  
  
  
 1) PERMIT VALUATION IS LOW, VALUATION
 HAS BEEN ADJUSTED TO THE AVERAGE
 CONSTRUCTION COSTS AS SET OUT BY ICC PER
 108.3 FBC*
  
 2) CORRECT THE FOLLOWING INFORMATION ON
 DRAWINGS,
 A) UPDATEWIND DESIGN CRITERIA TO
 NEW STANDARD
 B) BUILDING TYPE
 C) CONCRETE STRENGTH ON FOUNDATION
 NOTES AND GENERAL NOTES DIFFER
 D) FASTENERS DIFFER ON GARAGE DOOR BUCK
 DETAIL AND FASTENER SCHEDULE
 E) DETAIL B/1 ON FOUNDATION PLAN
 F) MEAN ROOF HEIGHT AND OVERALL
 BUILDING HEIGHT ON A/4
 G) ADDRESS ON SITE PLAN A/4 IS LAKE
 WORTH
  
 3) SHOW DRAINAGE ON SITE PLANS PER
 R401.3 FBC
  
 4) PROVIDE SOIL REPORT PER R401.4 FBC
 AND ARCHITECTS GENERAL NOTES #7
  
 5) FOUNDATION #3 SHALL BE A MINIMUM OF
 12" BELOW GRADE PER R403.1.4 FBC SHOW ON
 DETAIL H/2
  
 6) BEDROOM WINDOWS DO NOT MEET
 EMERGENCY EGRESS REQUIREMENTS PER R310.1
 - R310.1.4 FBC SHOW COMPLIANCE
  
 7) DOORS, WALLS, AND CEILING BETWEEN
 GARAGE AND DWELLING SHALL MEET THE
 REQUIREMENTS OF SECTION R309 FBC
  
 8) SPECIFY BEAM/LINTEL LENGTH AND THAT
 THEY COMPLY WITH 2104.1.5 FBC
  
 9) INSULATION IS REQUIRED BETWEEN
 GARAGE AND DWELLING (WALLS AND CEILING)
 PROVIDE DETAIL OR NOTES
  
 10) SUBMIT TRUSS DRAWINGS FOR ROOF AND
 2ND FLOOR PER106.1.1.2 FBC* AND
 R802.10.1
  
 11) THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 12) PROVIDE CERTIFICATION LETTER FROM
 ATRIUM WINDOWS THAT WIND LOADS WILL BE
 MET FOR SH WINDOWS
  
 13) PRODUCT APPROVAL FOR SIMONTON SGD
 HAS A MAXIMUM WIDTH OF 72"
  
 14) PROVIDE A KEY PLAN AND INSTALLATION
 SCHEDULE SIMILAR TO ATTACHED SAMPLE ALSO
 SHOW ATTACHMENT TYPE, ETC. ON PRODUCT
 APPROVALS
  
 15) RADON FEES SHALL BE COLLECTED FOR
 THE STATE OF FLORIDA PER CHAPTER 10D-91
 FAC
  
 16) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO A
 PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH
 ADMINISTATIVE AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-14 Cont ID  
Sent By btrobaug Date 2006-09-14 Time 18:07 Rev Time 0.50
Received By btrobaug Date 2006-09-14 Time 17:40 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-07-05 Cont ID  
Sent By btrobaug Date 2006-07-05 Time 17:43 Rev Time 0.50
Received By btrobaug Date 2006-07-05 Time 17:23 Sent To M
Notes
2006-07-06 00:00:00 
  
 PROVISO
  
 WHEN RESUBMITTING FOR MECHANICAL
 COMMENTS, PROVIDE THE FOLLOWING ON THE
 ELECTRICAL SHEET.
  
 PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 AN EQUIPMENT GROUND FROM THE DISCONNECT
 TO THE PANEL MUST BE INDICATED ON THE
 RISER PER 250.122.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-01-25 Cont ID  
Sent By btrobaug Date 2006-01-25 Time 16:50 Rev Time 0.75
Received By btrobaug Date 2006-01-25 Time 14:45 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-05-17 Cont ID  
Sent By adarroug Date 2007-05-17 Time 13:42 Rev Time 0.00
Received By adarroug Date 2007-05-17 Time 13:42 Sent To M
Notes
2007-05-17 13:42:37TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-08 Cont ID  
Sent By adarroug Date 2006-09-08 Time 15:39 Rev Time 0.00
Received By adarroug Date 2006-09-08 Time 15:39 Sent To E
Notes
2006-09-08 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-03 Cont ID  
Sent By adarroug Date 2006-07-03 Time 13:23 Rev Time 0.00
Received By adarroug Date 2006-07-03 Time 13:23 Sent To E
Notes
2006-07-03 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-23 Cont ID  
Sent By adarroug Date 2006-06-23 Time 15:10 Rev Time 0.00
Received By adarroug Date 2006-06-23 Time 15:10 Sent To Z
Notes
2006-06-23 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-13 Cont ID  
Sent By amorse Date 2006-03-13 Time 16:13 Rev Time 0.00
Received By amorse Date 2006-01-17 Time 15:19 Sent To  
Notes
2006-01-17 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-05-18 Cont ID  
Sent By tgordon Date 2007-05-18 Time 09:07 Rev Time 0.25
Received By tgordon Date 2007-05-18 Time 09:07 Sent To  
Notes
2007-05-18 09:07:54MECH. REVISION TO PLANS PAGE A3.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-10-03 Cont ID  
Sent By tgordon Date 2006-10-03 Time 16:18 Rev Time 0.30
Received By tgordon Date 2006-10-03 Time 16:18 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-06 Cont ID  
Sent By tgordon Date 2006-07-06 Time 09:04 Rev Time 0.45
Received By tgordon Date 2006-07-06 Time 09:03 Sent To P
Notes
2006-07-06 00:00:00*** DENIED ***
 1) WHITE-OUT MAY NOT BE USED ON PLANS,
 ALL HAND MADE CHANGES MUST BE SIGNED AND
 DATED AT EACH CHANGE WITH-OUT USING
 WHITE-OUT.
  
 2) AS SUPPLY AIR DUCT SIZES APPEAR TO BE
 OVER SIZED, PLEASE SUBMIT MANUAL D
 CALCULATIONS FOR RESIDENTIAL DUCT DESIGN
 OR OTHER APPROVED CALCULATIONS, PER 2004
 FBC/R M1601.1 .
  
 3) AT THIS TIME THE 14" RETURN AIR
 TRANSFER DUCT NEEDS TO BE 16" DUE TO THE
 SUPPLY AIR DUCT SIZES IN THE MASTER
 SUITE, SEE NOTE #4 (A) AND (C) MASTER
 SUITE.
  
 4) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-01-26 Cont ID  
Sent By tgordon Date 2006-01-26 Time 11:33 Rev Time 0.30
Received By tgordon Date 2006-01-26 Time 11:33 Sent To B
Notes
2006-01-26 00:00:00*** DENIED ***
 1) RETURN AIR TRANSFER DUCTS IN BEDROOM
 #2, AND MASTER BEDROOM ARE TO SMALL, SEE
 NOTE #2.
  
 2)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 3) 10"X10" RETURN AIR GRILL IS TO SMALL
 FOR A 4 TON A/C SYSTEM.
  
 4) THE CLOTHES DRYER VENT CAN NOT BE 3"
 FLEX PLEASE SEE 2004 FBC/M 504.6 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-10-03 Cont ID  
Sent By mperson Date 2006-10-03 Time 14:45 Rev Time 0.33
Received By mperson Date 2006-10-03 Time 14:45 Sent To M
Notes
2006-10-03 00:00:00 
  
  
 **********PROVISO******
 PER FBC-2004 PLUMBING, SECTION 802.4
 STANDPIPES: AUTOMATIC CLOTHES WASHERS
 SHALL BE INSTALLED WITH A STANDPIPE THAT
 SHALL EXTEND A MINIMUM OF 18" AND A
 MAXIMUM OF 42" ABOVE THE TRAP WEIR.

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-14 Cont ID  
Sent By jleech Date 2006-07-14 Time 07:20 Rev Time 0.00
Received By jleech Date 2006-07-14 Time 07:20 Sent To B
Notes
2006-07-14 00:00:00DENIED;
 1.SEE MECHANICAL PLAN REVIEW NOTE # 1.
 2.WATER HEATER PIPING DIAGRAM; PAN DRAIN
 AND PAN NOT SHOWN ON DRAWING. SHOW WERE
 PAN DRAIN WILL TERMINATE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-01-26 Cont ID  
Sent By jleech Date 2006-01-26 Time 07:53 Rev Time 0.33
Received By jleech Date 2006-01-26 Time 07:53 Sent To M
Notes
2006-01-26 00:00:00DENIED;
 1. RISER DIAGRAM; RISER FOR 2ND FLOOR
 CANNOT DUMP INTO LAV. VENT OF 1ST FLOOR.
 MUST DISCHARGE DOWN STREAM OF 1/2 BATH.
 MASTER BATH HAS SHR. NOT TUB. LAV. NOT
 W/M.
 2.WATER HEATER PLATFORM DETAIL; SHOW PAN
 UNDER HEATER,MUST HAVE A MIM. 3/4" DRAIN
 LINE TO OUTSIDE. SEE FBC-2004
 RESIDENTIAL SEC.P2801.5, P2801.5.1, AND
 P2801.5.2.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-29 Cont ID  
Sent By mmclean Date 2006-06-29 Time 07:43 Rev Time 0.00
Received By mmclean Date 2006-06-29 Time 07:43 Sent To I
Notes
2006-06-29 00:00:00NOTE:
 THE PROPOSED A/C SHALL NOT BE CLOSER
 THAN 3FT FROM REAR PROPERTY LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-25 Cont ID  
Sent By mmclean Date 2006-01-25 Time 13:47 Rev Time 0.00
Received By mmclean Date 2006-01-20 Time 17:57 Sent To E
Notes
2006-01-25 00:00:00DENIED,
 1. MUST MEET THE FRONT & SETBACK FOR
 MF14 RESIDENTIAL DISTRICT
 SEC94.75.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720