Plan Review Stops For Permit 06010506 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2010-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-12-09 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-12-09 |
Time |
10:57 |
Sent To |
|
|
Notes |
2010-12-09 10:58:50 | RESTAMP PLANS FOR PERMIT EXTENSION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-10-04 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-10-04 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-07-14 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-07-14 |
Time |
14:25 |
Sent To |
PC |
|
Notes |
2006-07-14 00:00:00 | | | | | DENIED | | | | 1) NO WHITE OUT PERMITTED ON DRAWINGS | | PLEASE MAKE CORRECTIONS TO OTHER REVIEWS | | | | 2) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-03-13 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-03-13 |
Time |
16:11 |
Sent To |
PC |
|
Notes |
2006-03-13 00:00:00 | | | | | | | DENIED | | | | | | | | 1) PERMIT VALUATION IS LOW, VALUATION | | HAS BEEN ADJUSTED TO THE AVERAGE | | CONSTRUCTION COSTS AS SET OUT BY ICC PER | | 108.3 FBC* | | | | 2) CORRECT THE FOLLOWING INFORMATION ON | | DRAWINGS, | | A) UPDATEWIND DESIGN CRITERIA TO | | NEW STANDARD | | B) BUILDING TYPE | | C) CONCRETE STRENGTH ON FOUNDATION | | NOTES AND GENERAL NOTES DIFFER | | D) FASTENERS DIFFER ON GARAGE DOOR BUCK | | DETAIL AND FASTENER SCHEDULE | | E) DETAIL B/1 ON FOUNDATION PLAN | | F) MEAN ROOF HEIGHT AND OVERALL | | BUILDING HEIGHT ON A/4 | | G) ADDRESS ON SITE PLAN A/4 IS LAKE | | WORTH | | | | 3) SHOW DRAINAGE ON SITE PLANS PER | | R401.3 FBC | | | | 4) PROVIDE SOIL REPORT PER R401.4 FBC | | AND ARCHITECTS GENERAL NOTES #7 | | | | 5) FOUNDATION #3 SHALL BE A MINIMUM OF | | 12" BELOW GRADE PER R403.1.4 FBC SHOW ON | | DETAIL H/2 | | | | 6) BEDROOM WINDOWS DO NOT MEET | | EMERGENCY EGRESS REQUIREMENTS PER R310.1 | | - R310.1.4 FBC SHOW COMPLIANCE | | | | 7) DOORS, WALLS, AND CEILING BETWEEN | | GARAGE AND DWELLING SHALL MEET THE | | REQUIREMENTS OF SECTION R309 FBC | | | | 8) SPECIFY BEAM/LINTEL LENGTH AND THAT | | THEY COMPLY WITH 2104.1.5 FBC | | | | 9) INSULATION IS REQUIRED BETWEEN | | GARAGE AND DWELLING (WALLS AND CEILING) | | PROVIDE DETAIL OR NOTES | | | | 10) SUBMIT TRUSS DRAWINGS FOR ROOF AND | | 2ND FLOOR PER106.1.1.2 FBC* AND | | R802.10.1 | | | | 11) THOSE PRODUCTS WHICH ARE REGULATED | | BY DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | 12) PROVIDE CERTIFICATION LETTER FROM | | ATRIUM WINDOWS THAT WIND LOADS WILL BE | | MET FOR SH WINDOWS | | | | 13) PRODUCT APPROVAL FOR SIMONTON SGD | | HAS A MAXIMUM WIDTH OF 72" | | | | 14) PROVIDE A KEY PLAN AND INSTALLATION | | SCHEDULE SIMILAR TO ATTACHED SAMPLE ALSO | | SHOW ATTACHMENT TYPE, ETC. ON PRODUCT | | APPROVALS | | | | 15) RADON FEES SHALL BE COLLECTED FOR | | THE STATE OF FLORIDA PER CHAPTER 10D-91 | | FAC | | | | 16) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO A | | PERMIT BEING ISSUED | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 | | FBC* = WEST PALM BEACH | | ADMINISTATIVE AMMENDMENTS TO FBC | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
18:07 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-09-14 |
Time |
17:40 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-07-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-05 |
Time |
17:43 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-07-05 |
Time |
17:23 |
Sent To |
M |
|
Notes |
2006-07-06 00:00:00 | | | | | PROVISO | | | | WHEN RESUBMITTING FOR MECHANICAL | | COMMENTS, PROVIDE THE FOLLOWING ON THE | | ELECTRICAL SHEET. | | | | PER 110.9 AND 110.10: OBTAIN THE | | AVAILABLE FAULT CURRENT AT THE UTILITY | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | INDICATE THE AIC RATING FOR THE | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | THE AVAILABLE FAULT. | | | | AN EQUIPMENT GROUND FROM THE DISCONNECT | | TO THE PANEL MUST BE INDICATED ON THE | | RISER PER 250.122. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-01-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-01-25 |
Time |
16:50 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2006-01-25 |
Time |
14:45 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-05-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-17 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-17 |
Time |
13:42 |
Sent To |
M |
|
Notes |
2007-05-17 13:42:37 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-09-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-08 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-08 |
Time |
15:39 |
Sent To |
E |
|
Notes |
2006-09-08 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-03 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-03 |
Time |
13:23 |
Sent To |
E |
|
Notes |
2006-07-03 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-23 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-23 |
Time |
15:10 |
Sent To |
Z |
|
Notes |
2006-06-23 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-03-13 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-01-17 |
Time |
15:19 |
Sent To |
|
|
Notes |
2006-01-17 00:00:00 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-18 |
Time |
09:07 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-05-18 |
Time |
09:07 |
Sent To |
|
|
Notes |
2007-05-18 09:07:54 | MECH. REVISION TO PLANS PAGE A3. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-03 |
Time |
16:18 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-10-03 |
Time |
16:18 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-06 |
Time |
09:04 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-07-06 |
Time |
09:03 |
Sent To |
P |
|
Notes |
2006-07-06 00:00:00 | *** DENIED *** | | 1) WHITE-OUT MAY NOT BE USED ON PLANS, | | ALL HAND MADE CHANGES MUST BE SIGNED AND | | DATED AT EACH CHANGE WITH-OUT USING | | WHITE-OUT. | | | | 2) AS SUPPLY AIR DUCT SIZES APPEAR TO BE | | OVER SIZED, PLEASE SUBMIT MANUAL D | | CALCULATIONS FOR RESIDENTIAL DUCT DESIGN | | OR OTHER APPROVED CALCULATIONS, PER 2004 | | FBC/R M1601.1 . | | | | 3) AT THIS TIME THE 14" RETURN AIR | | TRANSFER DUCT NEEDS TO BE 16" DUE TO THE | | SUPPLY AIR DUCT SIZES IN THE MASTER | | SUITE, SEE NOTE #4 (A) AND (C) MASTER | | SUITE. | | | | 4) BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-26 |
Time |
11:33 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-01-26 |
Time |
11:33 |
Sent To |
B |
|
Notes |
2006-01-26 00:00:00 | *** DENIED *** | | 1) RETURN AIR TRANSFER DUCTS IN BEDROOM | | #2, AND MASTER BEDROOM ARE TO SMALL, SEE | | NOTE #2. | | | | 2)BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | 3) 10"X10" RETURN AIR GRILL IS TO SMALL | | FOR A 4 TON A/C SYSTEM. | | | | 4) THE CLOTHES DRYER VENT CAN NOT BE 3" | | FLEX PLEASE SEE 2004 FBC/M 504.6 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-03 |
Time |
14:45 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-10-03 |
Time |
14:45 |
Sent To |
M |
|
Notes |
2006-10-03 00:00:00 | | | | | | | **********PROVISO****** | | PER FBC-2004 PLUMBING, SECTION 802.4 | | STANDPIPES: AUTOMATIC CLOTHES WASHERS | | SHALL BE INSTALLED WITH A STANDPIPE THAT | | SHALL EXTEND A MINIMUM OF 18" AND A | | MAXIMUM OF 42" ABOVE THE TRAP WEIR. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-07-14 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-07-14 |
Time |
07:20 |
Sent To |
B |
|
Notes |
2006-07-14 00:00:00 | DENIED; | | 1.SEE MECHANICAL PLAN REVIEW NOTE # 1. | | 2.WATER HEATER PIPING DIAGRAM; PAN DRAIN | | AND PAN NOT SHOWN ON DRAWING. SHOW WERE | | PAN DRAIN WILL TERMINATE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-01-26 |
Time |
07:53 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2006-01-26 |
Time |
07:53 |
Sent To |
M |
|
Notes |
2006-01-26 00:00:00 | DENIED; | | 1. RISER DIAGRAM; RISER FOR 2ND FLOOR | | CANNOT DUMP INTO LAV. VENT OF 1ST FLOOR. | | MUST DISCHARGE DOWN STREAM OF 1/2 BATH. | | MASTER BATH HAS SHR. NOT TUB. LAV. NOT | | W/M. | | 2.WATER HEATER PLATFORM DETAIL; SHOW PAN | | UNDER HEATER,MUST HAVE A MIM. 3/4" DRAIN | | LINE TO OUTSIDE. SEE FBC-2004 | | RESIDENTIAL SEC.P2801.5, P2801.5.1, AND | | P2801.5.2. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-29 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-29 |
Time |
07:43 |
Sent To |
I |
|
Notes |
2006-06-29 00:00:00 | NOTE: | | THE PROPOSED A/C SHALL NOT BE CLOSER | | THAN 3FT FROM REAR PROPERTY LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-25 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-20 |
Time |
17:57 |
Sent To |
E |
|
Notes |
2006-01-25 00:00:00 | DENIED, | | 1. MUST MEET THE FRONT & SETBACK FOR | | MF14 RESIDENTIAL DISTRICT | | SEC94.75. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|