Plan Review Stops For Permit 06010452 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-10-25 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-10-25 |
Time |
14:17 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2006-10-25 |
Time |
14:17 |
Sent To |
|
|
Notes |
2006-10-25 14:19:21 | BUILDING PROVISO: | | OVERHEAD GARAGE DOORS WILL REQUIRE A SEPERATE PERMIT. | | SPRAY BOOTH WILL REQUIRE A SEPERATE PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-08-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-08-23 |
Time |
07:18 |
Rev Time |
6.66 |
Received By |
jwitmer |
Date |
2006-08-22 |
Time |
13:38 |
Sent To |
|
|
Notes |
2006-08-23 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06010452/ 06030925 | | | | ADD:422 SUNSET/ 433 AVON RD | | CONT: BURKHARDT CONSTRUCTION | | TEL: (561)659-1400 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 3RD REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) THE PROPOSED BUILDING STRUCTURE | | TRANSGRESSES LEGAL BOUNDARY LINES | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE | | RECORDED AT THE COUNTY COURTHOUSE. | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | OF TITLE' DOCUMENT SO THAT FBC TABLE 601 | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | NOT APPLICABLE. | | 2A)THE UNITY OF TITLE SUBMITTED IS NOT | | FOR THE LOTS BACK TO BACK, PHASE I AND | | PHASE II BUT FOR THE LOTS THAT ARE ON | | BOTH SIDES OF SUNSET. THIS IS A MATTER | | THAT ZONING, UTILITIES NOR THE LAW | | DEPARTMENT HAS APPROVED. THIS ISSUE HAS | | TO BE RESOLVED BEFORE A PERMIT WILL BE | | ISSUED. | | 2B)ALSO SHEET A-1 PHASE-I REMOVE THE | | FENCE FROM ACROSS THE RITE OF WAY BEFORE | | A PERMIT WILL BE ISSUED. | | 2C)PROVIDE A UNITY OF TITLE THAT HAS | | BEEN APPROVED FOR LOTS 116 AND 142 | | COMBINING THESE LOTS INTO A SINGLE LOT. | | | | 3) CONFLICT OR DISCREPANCY IN PLANS AND | | THE ARHITECTS RESPONSE. SHEET A-1 | | PHASE-II ITEM# 17 INDICATES THAT THIS IS | | A NEW OVERHEAD FIRE RATED DOOR, WHEREAS | | COMMENT# 8 RESPONSE (06030925) INDICATES | | THIS IS AN EXISTING 3HR FIRE RATED | | DOORWAY. WHICH IS IT, SINCE THIS CROSSES | | PROPERTY LINES NO PERMIT WAS PULLED | | PROVIDE LITERATURE ON THE FIRE RATING | | SINCE WE STILL NEED A 2 HR SEPERATION | | FROM THE PAINT SHOP. TABLE 302.1.1. | | | | 4) SHEET A-1 PHASE-II INDICATES A NEW | | HANDICAPPED RAMP AS A RESULT OF A | | MEETING BETWEEN THE OWNER, DESIGN TEAM, | | CONTRACTOR AND BUILDING DEPARTMENT. | | 11-4.8.4.(2) LANDINGS. ALL LANDINGS | | ON RAMPS SHALL NOT BE LESS THAN 60" | | CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | HAVE NOT LESS THAN 72" OF STRAIGHT & | | LEVEL CLEARENCE. LOWER LANDING IS NOT | | INDICATED ON PLAN. WILL REQUIRE THE | | ELIMINATION OF ANOTHER PARKING SPOT. | | | | 5) THE ARCHITECT HAS SUBMITTED A LETTER | | ON DISPROPORTIONATE COST BUT THIS LETTER | | STILL DOES NOT RELIEVE THE OWNER FROM | | VERTICAL ACCESSIBLIITY. | | 11-4.1.6(1)(F) NOTHING IN THIS SECTION | | SHALL BE CONSTRUED TO RELIEVE THE OWNER | | OF ANY BUILDING, STRUCTURE OR FACILITY | | FROM THE DUTY TO PROVIDE VERTICAL | | ACCESSIBILITY TO ALL LEVELS ABOVE AND | | BELOW OCCUPIABLE GRADE LEVEL, REGARDLESS | | OF WHETHER THE CODE REQUIRES AN ELEVATOR | | TO BE INSTALLED IN SUCH BUILDING, | | STRUCTURE. | | THE DESIGN TEAM HAS CREATED A RAMP | | TO ENTER THE WAREHOUSE PORTION BUT NO | | VERTICAL ACCESSIBLITY TO THE OFFICES. | | | | 6A) A-1, PHASE I INDICATES ROOF TOP AIR | | HANDLERS, THE CURB IS TO BE TIED TO THE | | ROOF DECK BY 3"X3" ANGLES NO MENTION AS | | TO HOW THE ANGLES ARE FASTENED TO THE | | ALUMINIUM FRAME.2004 FBC BUILD 1503.1 | | | | 6B) THESE SAME 3"X3" ANGLES ARE TO BE | | BOLTED TO THE ROOF WHAT TYPE OF WEATHER | | PROOFING IS TO OCCUR AROUND THE BOLTS? | | 2004 FBC BUILD 1503.1 | | | | 6C) M-1.2 PHASE I PLANS INDICATE THE | | HURRICANE SUPPORT DETAIL WITH A 5/8" | | EYEBOLT THROUGHT THE ROOF DECK BUT NO | | MENTION AS TO HOW TO MAKE THE CONNECTION | | | | WEATHER TIGHT? 2004 FBC BUILD 1503.1 | | | | 7) ONLY ONE COPY OF LISTED ITEMS BELOW | | REQUIRES (2) SUBMITTALS: | | 7A) MSDS SHEETS | | 7B) CARBON MONOXIDE MONITORING SYSTEM. | | | | 8) WORK TO BE COMPLETED UNDER SEPERATE | | PERMIT: | | A) EXTERIOR MOTORIZED OVERHEAD DOORS | | B) PAINT BOOTH, MIXING ROOM & SUPRESSION | | SYSTEM. | | C) GENERATOR, PAD & LANDSCAPE WALL | | D) FUEL TANKS | | E) FENCING ACROSS SUNSET WITH CITY | | APPROVAL. | | F) KLAUS CAR STORAGE RACKS | | | | BUILDING PROVISOS: | | 109.3.10* IMPACT OF CONSTRUCTION. ALL | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | CODE SHALL BE PERMORMED IN A MANNER SO | | AS NOT TO ADVERSELY IMPACT THE CONDITION | | OF ADJACENT PROPERTY, UNLESS SUCH | | ACTIVITY IS PERMITTED TO AFFECT SAID | | PROPERTY PURSUANT TO A CONSENT BY THE | | APPLICABLE PROPERTY OWNER, UNDER TERMS & | | CONDITIONS AGREEABLE TO THE APPLICABLE | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | LIMITED TO THE CONTROL OF DUST, NOISE, | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | THE STORAGE OF CONSTRUCTION MATERIALS. | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | ADVERSELY IMPACT HISTORIC SURFACE WATER | | DRAINAGE FLOWS SERVING ADJACENT | | PROPERTIES, & MAY REQUIRE SPECIAL | | DRAINAGE DESIGN COMPLYING WITH | | ENGINEERING STANDARDS TO PRESERVE THE | | POSITIVE PATTERNS OF THE AFFECTED SITES. | | ACCORDINGLY, DEVELOPERS, CONTRACTORS, | | AND OWNERS OF ALL NEW RESIDENTIAL | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR | | ITEMS, ON EXISTING PROPERTIES RESULTING | | IN A DECREASE IN EXCESS OF 800SQ FT OF | | PERMEABLE LAND AREA ON ANY PARCELL SHALL | | AS A PERMIT CONDITION, PROVIDE A | | PROFESSIONALLY PREPARED DRAINAGE PLAN | | CLEARLY INDICATING COMPLIANCE WITH THIS | | PARAGRAPH. UPON COMPLETION OF THE | | IMPROVEMENT, A CERTIFICATE FROM A | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | THE INSPECTOR IN ORDER TO RECEIVE | | APPROVAL OF THE FINAL INSPECTION. | | | | 109.3.10.1 HURICANE PROTECTION. | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | ALLOW CONSTRUCTION RELATED MATERIALS | | EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | OTHERWISE UNSECURED AT A CONSTRUCTION | | SITE FROM 24 HRS. AFTER A HURRICANE | | WATCH HAS BEEN ISSUED UNTIL THE | | HURRICANE WATCH OR WARNING HAS BEEN | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | REMOVED FROM THE CONSTRUCTION SITE OR | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | THE DANGER OF SUCH CONSTRUCTION | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | WINDS. | | ANY PERSONS WHO FAILS TO COMPLY TO | | REMOVE OR SECURE THE CONSTRUCTION | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | EXCEED $500.00. | | IN ADDITION TO THE ABOVE, A LICENSED | | CONTRACTOR WHO VIOLATES THIS SECTION | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | TO SECTION 113 OF THIS CHAPTER. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-07-12 |
Time |
07:07 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-06-12 |
Time |
14:33 |
Sent To |
ENG |
|
Notes |
2006-06-12 00:00:00 | | | | | 1) WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE | | ALL VOIDED PAGES. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPITION OF THE | | REVISION MADE, IDENTIFYING THE SHEETS OR | | SPECIFIC PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOU PERMIT. | | THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 2) WPB.AMEND. 106.1.3 THE BUILDING | | OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY STANDARDS FOR PLANS | | AND SPECIFICATIONS,IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD RETENTION | | PROGRAM. "HAND WRITTEN INFORMATION IS | | NOT ACCEPTABLE ON ENGINEERED DRAWINGS". | | THE DRAWINGS AND INFORMATION BY THOMAS | | J.TWOMEY,P.E. WERE ALTERED. THIS IS NOT | | ACCEPTABLE.THE DRAWINGS SHALL BE | | ORIGINALLY SIGNED AND SEALED BY THE | | ENGINEER OF RECORD. SEE 61G15-23.001/ | | 61G15-23.002 FOR MORE INFORMATION. | | | | 3) 713.13(2) F.S.THE NOTICE OF | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | THE DESCRIBED IMPROVEMENT OR | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | DAYS OF RECORDING. THE OWNER MUST SIGN | | THE NOC. PER FS.713.13(1)(G). | | | | 4) WPB ADMIN CODE 106.3*3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. THE STATE | | COVER SHEETS ARE REQUIRED FOR THOSE | | PRODUCTS WHICH ARE APPROVED BY THE | | STATE. NOTE: THE PRODUCT APPROVAL FOR | | THE PGT FIXED WINDOW HAS BEEN REVISED | | AND UPDATED. SUBMIT THE UPDATED PRODUCT | | APPROVAL FOR THIS PRODUCT. SEE | | WWW.FLORIDABUILDING.ORG. #FL243-R3 FOR | | MORE INFORMATION. | | | | 5)FBC 704.8 ALLOWABLE AREA OF OPENINGS. | | THE MAXIMUM AREA OF UNPROTECTED OR | | PROTECTED OPENINGS PERMITTED IN AN | | EXTERIOR WALL IN ANY STORY SHALL NOT | | EXCEED THE VALUES SET FORTH IN TABLE | | 704.8 . WHERE BOTH UNPROTECTED AND | | PROTECTED OPENINGS ARE LOCATED IN THE | | EXTERIOR WALL IN ANY STORY, THE TOTAL | | AREA OF THE OPENINGS SHALL COMPLY WITH | | THE FOLLOWING FORMULA: SEE (FBC TABLE | | 602) FOR ADDITIONAL INFORMATION. IF THE | | WINDOWSWILL BE REMOVE THEY WILL HAVE | | TO MEET THE REQUIREMENTS OF THESE TWO | | SECTIONS OF THE CURRENT FBC. | | | | 6) ARE THERE TWO BUILDINGS OR ONE AT | | THIS ADDRESS? IF IT'S TWO BUILDINGS | | SUBMIT THE UNITY OF TITLE COMBINING THE | | TWO STRUCTURES. | | | | 7) SHOW THE CORRECT SQUARE FOOTAGE OF | | THIS BUILDING. THE DRAWINGS INDICATE THE | | SQUARE FOOTAGE AS 22,922 HOWEVER, THE | | DIMENTIONS OF THIS BUILDING DOES NOT | | NATCH THAT FIGURE. | | | | 8) SHEET D-1 SHOWS A FENCE WITH A GATE | | IN THE MIDDLE OF SUNSET ROAD. IF THE | | OWNER HAS PERMISSION FOR THE | | INSTALLATION OF THES FENCE PROVIDE THE | | INFORMATION FROM THE ENGINEERING DEPT. | | WHICH ALLOW THIS FENCE TO BE | | CONSTRUCTED. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | | | . | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-04-07 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-04-07 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-04-06 |
Time |
13:55 |
Sent To |
|
|
Notes |
2006-04-06 00:00:00 | 1) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT BEFORE A | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OF | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | 2) IF GLASS BLOCK WON'T BE USED IN THE | | BUILDING,REMOVE THE NOTE #12 ON SHEET | | A-1. ALSO IF THERE IS ANY OTHER | | INFORMATION WHICH DOES NOT AFFECT THIS | | PROJECT PLEASE HAVE IT REMOVED FORM THE | | DRAWINGS AND NOTES. | | | | 3) 106.3.3* PRODUCT APPROVALS- 2004 | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITTING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. THE STATE COVER | | SHEET IS REQUIRED FOR THOSE PRODUCTS | | WHICH ARE APPROVED BY THE STATE. THE | | ONES SUBMITTED DON'T HAVE THE COVER | | SHEETS. | | | | 3) NOTE: NOA #02-0702.04 FOR THE SINGLE | | HUNG WINDOW HAS EXPIRED. | | | | 4) THE SEALS ON SHEETS D-1 AND A-1 ARE | | ILLEGIBLE. ALL INFORMATION ON | | CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY. SEE FBC.106.1.1 | | | | 5) 110.2* W. P. B. ADMINISTRATIVE CODE, | | INFORMATION THAT IS REQUIRED FOR RECORD | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | A) THE EDITION OF THE CODE UNDER WHICH | | THE PERMIT WAS ISSUED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE DESIGN OCCUPANT LOAD, SEE 1004. | | D) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | IS REQUIRED. | | E) ANY SPECIAL STIPULATIONS & CONDITIONS | | OF THE BUILDING PERMIT. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-01-31 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2006-08-22 |
Time |
13:38 |
Sent To |
PC |
|
Notes |
2006-01-30 00:00:00 | 1) PRODUCT APPROVALS ARE REQUIRED FOR | | ALL EXTERIOR WINDOWS AND DOORS, ALSO | | THE GLASS BLOCK. | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 2)SHOWW A DETAIL DRAWWING WHERE THE | | STUCCO WILL BE FINISH OVER THE 1" FOAM. | | SHOW HOW THE FOAM IS ATTATCHED AND WHAT | | IT IS ATTATCHED TO. ALSO WHERE IS | | EXHAUST FAN IS REMOVED, SHOW THE FRAMING | | DETAIL OF HOW THE HOLE WILL BE SEALED. | | | | 3) ARE ALL THE WINDOWS FIXED WINDOWS? | | SUBMIT A WINDOW/DOOR SCHEDULE SHOWING | | THE SIZE AND TYPWOF EACH DOOR AND | | WINDOW. | | | | 4) IF ANY ROOFING WORK IS REQUIRED, | | SUBMIT THE PRODUCT APPROVALS FOR THE | | ROOFING PRODUCT WHICH WILL BE USED. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEK:(561)805-6726 | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
P |
Date |
2007-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-04 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-04 |
Time |
10:02 |
Sent To |
|
|
Notes |
2007-02-04 10:40:47 | ** VALUE WAS INCREASED TO $525K,. $411K WAS INCREASED | | ON THIS PERMIT AND $114K WAS ALREADY ON 06030925. | | | | | | | | REDLINED, ALL EXISTING OFFICE AREAS IS BEING BROUGHT UP | | TO THE 2004 FBC CHAPTER 13 FOR LIGHTING AND CONTROLS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
F |
Date |
2006-12-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-08 |
Time |
19:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-08 |
Time |
18:11 |
Sent To |
|
|
Notes |
2006-12-08 19:08:10 | ***UNSAT *** | | | | | | 1) NOTE:PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE | | OF WORK ON THIS PROJECT NEEDS TO BE UPDATED. PLEASE | | KNOW EVEN WITH THE PREVIOUS APPLIED VALUE UNDER 433 | | AVON WHICH WAS $114K AND THE VALUE ON THIS PERMIT AT | | $85K, THE VALUE FOR ALL WORK IN ACTUAL SCOPE IS | | EXTREMELY LOW. PLEASE KNOW THE ELECTRICAL ALONE IN THIS | | BUILDING IS HIGHER THAN THE APPLIED VALUE FOR THIS | | PERMIT. PLEASE KNOW THE VALUE SHALL INCLUDE ALL LABOR | | AND MATERIALS. | | PLEASE KNOW IF A VALUE IS NOT ADJUSTED FOR ALL WORK AND | | MATERIALS AS SHOWN, ONE WILL BE APPLIED BASED ON THE | | TABLES FROM THE FBC OR MARSHALL'S AND SWIFT GUIDE. | | FBC 108.3 | | | | 2) NOTE: PLEASE SEE PANEL P5 IS BEING SHOWN AT 600A'S | | WITH A 225A FEED. PLEASE VERIFY. | | FBC 106.1.2 | | | | 3) NOTE: PLEASE KNOW AS THE SCOPE INVOLVED EXCEEDS THAT | | OF 30%, PLEASE SEE FBC CHAPTER 13 WILL APPLY TO THE | | EXISTING OFFICES. THIS WAS GONE OVER IN PREVIOUS | | MEETINGS WITH THE ENGINEER AND DESIGN TEAM AND THIS | | INFORMATION WAS TO BE UPDATED AND APPLIED TO PLANS. | | PLEASE SEE LIGHTING CONTROLS, LIGHTING DENSITIES, ETC. | | PLEASE SEE OTHER ROOM(S) ON PLANS WHICH DO NOT SEEM TO | | INDICATE A SEPARATE SPACE CONTROL. | | PLEASE SEE NEW OUTSIDE LIGHTS REQUIRED TO BE PART OF | | THE EXTERIOR LIGHTING POWER ALLOWANCES. | | FBC 13-415.1.ABC.1.1, .1.2 AND .1.3 | | 13-415.2. | | | | 4) NOTE: PLEASE VERIFY SUB SECTIONS FOR PANELS, 4, AND | | 2 NOT ON RISER. | | | | 5) NOTE: PLEASE PROVIDE A COMPLETE LOAD SUMMARY FOR THE | | GENERATOR AS WELL AS THE LOADS ON EACH OF THE EDP AND | | THE EDPA. | | 220, 702.5 | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-22 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-21 |
Time |
18:44 |
Sent To |
|
|
Notes |
2006-10-22 08:41:07 | ****** NOTESREDLINED ********* | | | | | | | | 1) PLEASE SEE AS ONLY TWO SETS OF SPEC BOOKS WERE | | SUBMITTED AND THREE SETS OF PLANS WERE SUBMITTED, THE | | THIRD SET OF MANUFACTURES SPECS/CUT SHEETS FOR EACH OF | | THE ATS'S WERE ATTACHED TO THE SET 3OF 3. ON RISER | | SHEET. | | THE OTHER TWO SETS WERE PLACED IN SPEC BOOKS . | | | | 2) PLEASE SEE PLANS CALL FOR SPRAY BOOTH TO BE UNDER | | SEPARATE PERMIT(S) AND ARE NOT INCLUDED IN EITHER PHASE | | ONE OR PHASE TWO ON PLANS. PLEASE KNOW THAT THE | | MANUFACTURES SPEC WERE REMOVED FROM THE TWO SPEC BOOKS | | SUBMITTED AND PLACED WITH THE OTHER THREE SETS OF SPECS | | SUBMITTED SEPARATELY (LOOSE). | | THESE ARE LABELEDNIC AND WILL BE RETURNED TO | | CONTRACTOR FOR FUTURE USE. | | | | 3) NOTE: PLEASE SEE PHASE I RISERCALLS FOR SPACE FOR | | "FUTURE" METER, THIS IS REDLINED AS NO 2ND METER IS | | PERMITTED UNLESS PROPER REQUIRED TENANT SEPARATION IS | | CONSTRUCTED. | | | | 4) PLEASE BE AWAREBOTH PERMITS FOR GEN-ELEC AND FUEL | | PERMITS 06061596(ELEC) AND 06061597(FUEL) HAVE HAD | | ADDRESSES CHANGED TO CORRELATE WITH THE ADDRESS OF 422 | | SUNSET AND GEN-COM PERMIT NUMBER 06061595. | | | | | | ELECTRICAL PLANS STAMPED ALONG WITH SPECS FOR ATS'S. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | 2006-10-22 08:01:50 | REVIEW IN PROGRESS | 2006-10-21 18:44:46 | ELEC REVIEW IN PROGRESS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-10 |
Time |
21:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-10 |
Time |
20:42 |
Sent To |
|
|
Notes |
2006-08-10 00:00:00 | *** UNSAT *** | | | | ** PLEASE SEE COMMENTS BELOW, SOME ARE | | EXISTING AND SOME ARE NEW BASED ON PLANS | | SUBMITTED. | | | | 1) NOTE: PLEASE SEE PHASE 1, SHOWS METER | | FUTURE AND YET AND METER CAN IS BEING | | INSTALLED. PLEASE SEE PHASE II WHICH | | SHOWS THE METER BEING INSTALLED AS | | EXISTING. | | PLEASE KNOW WITHOUT TENANT SEPARATION | | THIS METERCAN IS NOT PERMITTED. SEC'S | | FROM GUTTER SHALL GO DIRECTLY INTO THE | | MAIN2 OF 2. | | THIS IS A SINGLE OCCUPANCY , ANY FUTURE | | METER CAN WILL BE DONE AT THE TIME OF | | SUCH SEPARATION OF TENANTS TAKES PLACE. | | THIS WAS THE UDNERSTANDING OF THE LAST | | MEETING BY THE DESIGN TEAM. | | PLEASE ALSO SEE PHASE ONE FOR RISER | | SHOWS CONDUIT AND FEEDERS TO NOTHING | | AFTER THE MAIN DISCONNECT. | | | | 2) NOTE: PLEASE SEE PLANS INDICATE A | | PHASE 1 FOR E-1.1, YET TITLE BLOCK CALLS | | FOR PHASE II. PLEASE SEE THIS SHEET DOES | | NOT CORRELATE WITH PHASING OF THE | | PROJECT. | | PLEASE SEE SPRAY BOOTH IS BEING SHOWN AS | | FUTURE ON PHASE TWO SHEETS, YET SHOWS AS | | BEING INSTALLED ON OTHER SHEETS AND ON | | PAHSE TWO PANEL SCHEDULES. | | PLEASE KNOW ALL INFORMATION AS REQUESTED | | FOR LOCATIONS ETC WAS NOT SHOWN FOR | | SPRAY BOOTH. | | PLEASE SEE NOTE FROM PREVIOUS REVIEW | | BELOW; | | "PLEASE SEE NEC 511 AND 516. ALL AREAS | | AND CLASS LOCATION SHALL BE INDICATED | | AND LAYED OUT PER NEC 500, 500.5, 501, | | CLASS 1 DIV 1, CLASS 1 DIV 2? | | NFPA-88B, 1997 | | PLEASE SEE THIS SHOWN WITH A "WAREHOUSE" | | OCCUPANCY WHICH DOES NOT SEEM TO | | CORRELATE WITH NEW REVISED PLANS AND | | PROPOSED WORK. | | | | 3) NOTE: PLEASE SEE SEAL BY THE ENGINEER | | IS NOT CLEAR AND VISABLE WITH ALL | | INFORMATION ON SAID SEAL. THIS OFFICE | | HAS ATTEMPTED TO SHADE THESE SHEETS TO | | SHOW ALL INFORMATION, HOWEVER THIS HAS | | NOT BEEN AFFECTIVE. | | PLEASE SEE FAC 61G15-23.001 | | "RAISED SEAL MUST BE CLEAR AND VISABLE" | | | | 4) NOTE: MISSING DISCONNECT'S FOR CU'S. | | 440.11 | | | | 5) NOTE: PLEASE SEE MISSING GFI FOR CU'S | | 210.63, 210.8. | | | | 6) NOTE: PLEASE SEE WIRE AND CONDUIT | | SCHEDULE AS #2 SHOWS AN "EQUIPMENT | | GROUNDING CONDUCTOR" BEFORE THE FIRST | | MEANS OF DISCONNECT. PLEASE SEE 250.6, | | 250.24 B AS THE "EQUIPMENT GROUNDING | | CONDUCTOR" IS ONLY INSTALLED AFTER THE | | FIRST MEANS OF DISCONNECT. | | PLEASE SEE SEC'S TO MAIN 1 OF 1. | | | | | | | | | | | | | | 6) NOTE: ** IMPORTANT" AS REQUESTED BY | | THE BUIDLING REVIEWER ON PREVIOUS NOTES: | | ONCE ALL REVIEWS ARE COMPLETE, BEFORE | | RESUBMITTING PLANS, PLEASE COMPLETELY | | REMOVE ALL OLD/VOIDED SHEETS AND ONLY | | INSERT NEW REVISED SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. ONE COPY | | OF THE OLD/VOIDED REMOVED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP TO ALLEAVIATE ANY DELAYS | | INTHE PROCESS. | | | | ** PLEASE KNOW, ONE SET OF EACH OF THE | | PREVIOUS SUBMITTED ELECTRICAL PLANS | | ALONG WITH THE NEW REVISED ELECTRICAL | | PLANS ARE BEING RETAINED BY THIS OFFICE | | AS EACH SET CONTAINS COMPLETELY | | DIFFERENT INFORMATION FOR USE/OCCUPANCY | | ETC. | | | | PLEASE SEE ANY COMMENTS FROM OTHER | | TRADES WHICH MAY AFFECT ELETRICAL PLANS. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, OR COMMENTS | | PLEASE CALL. | | A CALLED WAS PLACED TO THE ELECTRICAL | | ENGINEER'S OFFICE AND A MESSAGE WAS LEFT | | AS OF THIS REVIEW TO GO OVER PLANS. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-07 |
Time |
21:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-07 |
Time |
19:20 |
Sent To |
B |
|
Notes |
2006-07-07 00:00:00 | ********* UNSAT 4TH REVIEW ************ | | | | PLEASE SEE NOTES BELOW AS MANY ARE NEW | | DUE TO COMPLETELY NEW RISERAND MANY | | CHANGES ON PLANS. | | PLEASE SEE OTHER NOTES PER THIS REVIEW. | | * REPRESENTS FBC ADMINISTRATIVE SECTION | | 106.1.2 AS ADOPTED BY THE CITY OF WEST | | PALM BEACH | | | | 1) NOTE: IMPORTANT, ONCE ALL REVIEW(S) | | ARE DONE AND BEFORE PLANS ARE | | RESUBMITTED, PLEASE COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS FROM SETS AND ONLY | | INSERT THE NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | PLEASE ALSO REMOVE ALL STAPLED PRODUCT | | APPROVALS WHICH ARE NOW ATTACHED TO | | PLANS. THESE SHOULD BE IN TWO SETS | | SEPARATELY FROM PLANS AND NOT ATTACHED. | | THIS COMMENT IS FOR OTHER TRADE(S) | | SHEETS WHICH WERE LEFT IN SETS. | | PLEASE ONLY SUBMIT ONE COPY OF THE | | OLD/VOIDED REMOVED SHEETS FOR REFERENCE. | | | | 2) NOTE: PLEASE BE SURE PLANS REFLECT | | THE CURRENT CODES IN EFFECT. PLEASE SEE | | ELECTRICAL PLANS REFLECT THE 2001 FBC. | | PLEASE ADJUST AND REFERENC THE FOLLOWING | | WHICH ARE CURRENTLY UNDER. | | 2002 NFPA-70 (DONE), 2002 NFPA-72, 2003 | | NFPA-101, 2004 FBC. | | | | 3) NOTE: PLEASE SEE NOTES BELOW WITH | | RESPECT TO SERVICE(S) BEING PROPOSED. | | PLEASE KNOW, IN THE MEAN TIME ANY ATS | | BEING INSTALLED IN ANY SERVICE REQUIRES | | THE MANUFACTURES SPECS/CUT SHEETS TO BE | | SUBMITTED. PLEASE BE SURE THESE SHEETS | | INDICATE A LISTING BY ANRTL. | | 106.1.2 FBC ADMIN SECT, 110.3 | | | | 4) NOTE: PLEASE CORRELATE PLANS WITH | | RISER DIAGRAM. PLEASE SEE SOME SERVICE | | EQUIPMENT WHICH IS BEING SHOWN ON RISER, | | HOWEVER THESE ARE NOT ON PLANS, POWER OR | | LIGHTING SHEETS? (EDP ETC.) | | 106.1.2* | | | | 5) NOTE: PLEASE CORRELATE ALL CIRCUITING | | ON PLANS WITH SUBMITTED PANEL SCHEDULES. | | PLEASE SEE MANY ITEMS ARE BEING SHOWN | | CIRCUITED TO THE PREVIOUS PANEL | | SCHEDULES. | | PLEASE SEE PANEL SCHEDULES WHICH SHOW | | SPARE, YET CIRCUITS ARE ON PLANS. | | PLEASE SEE A/C RTU'S BEING SHOWN TO MDP, | | HOWEVER MDP DO NOT SHOW THESE ANYMORE. | | PLEASE SEE ME LTS ETC. | | 106.1.2* | | | | 6) NOTE: PLEASE KNOW, EM LIGHTING SHALL | | BE CIRCUITED PER 700.12E. | | PLEASE KNOW, AS THE CIRCUIT FOR THE EM | | LTS IS NOW SHOWN AS A BLANK ON PANEL | | SCHEDULE. PLEASE KNOW UNLESS THE | | GENERATOR WAS PERMITTED UNDER THIS | | PERMIT WHICH IT IS NOT, EM LTSWILL BE | | REQUIRED WITH BATTERY BACK UP AT A MIN | | AT THIS TIME AND UNDER THIS PERMIT. | | PLEASE SEE 700.12E, 700.16, LS 101 7.8, | | 7.9. | | | | 7) NOTE: PLEASE SEE"EDP"IS BEING | | SHOWN AS 800A MLO AND WITH A LOAD OF | | 300+ A'S YET, THE OCP DEVICE SHOWN ON | | MDP IS ONLY SHOWN AS 125A'S? PLEASE SEE | | THIS EXCEEDS THE RATING OF THE | | OVERCURRENT DEVICE. | | 240.4,310.16,240, ETC. | | | | 8) NOTE: PLEASE SEE MDP IS NOTED AND | | CIRCUITS ON MDP ETC ARE NOTED WITH A #1 | | IN A CIRCLE WHICH MENTIONS TO SEE RISER | | FOR FEEDERS, CONDUITS ETC. PLEASE SEE | | RISER DOES NOT INDICATE ANY FEEDERS ETC | | FROM MDP TO ATS AND FROM ATS TO EDP. | | PLEASE REVISE AND ADJUST. | | 240.4,310.16, 215.5 ETC | | | | 9) NOTE: PLEASE KNOW, A DISCONNECTING | | MEANS WILL BE REQUIRED GROUPED FOR | | FEEDERS COMING FROM FUTURE GENERATOR. | | THIS MAY BE SOMETHING PLACED INTO THE | | DESIGN AT THIS TIME OR AT A LATER DATE. | | PLEASE ALSO SEE NOTES FOR SERVICE. | | 225.31-225.39, 110.27 | | | | 10) NOTE: PLEASE INCLUDE SECT #2 OF P1 | | ON RISER DIAGRAM. | | PLEASE ALSO INDICATE IF THE PANEL "P1" | | CONTAINS OCP FEEDING SECT #2 OR DOES | | "P1" CONTAIN "FEED-THRU"LUGS. | | PLEASE SHOW. | | 106.1.2* | | | | 11) NOTE: PLEASE SEE ENERGY CALCULATIONS | | DO NOT REFLECT LIGHTING INSTALLED AND | | LIGHTING ALLOWANCE IN CALCS. IT IS NOTED | | ON PLANS AND LETTER FROM ENGINEER THAT | | THE "LPD" ARE UNDER MAX LIMITS, YET THE | | TOTAL WATTAGE ETC SHOULD BE IN | | CALCULATIONS. | | FBC 13-415.1.AB.1,13-415.2.ABC.1 | | | | 12) NOTE: PLEASE CLARIFY NEWOR | | EXISTING ROOF TOP GFI(S) FOR A/C | | EQUIPMENT. | | 210.63,210.8 | | | | 13) NOTE: PLEASE CLARIFY THE NUMBER OF | | AHU'S IN THIS SPACE, AS "M" SHEET | | MENITONS AHU'S #1, #2, #3 AND #4?? | | ?? | | | | 14) NOTE: PLEASE SEE NOTICE OF | | COMMENCMENT ATTACHED TO PACKAGE HAS | | EXPIRED PER FS 713.13(2). | | THIS WILL BE REQUIRED OT BE RE-RECORDED | | AND SUBMITTED BEFORE PICKING UP PERMIT. | | | | PLEASE SEE THE FOLLOWING AS COMMENTED | | WITH RESPECT TO THE SERVICE. | | | | ** CALLED ENGINEER ON 7/7/06 AT 4:45 PM | | AND LEFT MESSAGE TO CONTACT ME WITH | | RESPECT TO THE SERVICE, SEPARATION ETC. | | | | AS PER CONSULTATION WITH MR. ROBERT AND | | OTHERS. THE FOLLOWING TWO OPTIONS MAY BE | | DONE. | | | | 1) IF OPENING BETWEEN THIS SPACE AND THE | | ADJOINING FUTURE SPACE IS GOING TO | | REMAIN, EVEN WITH THE RATED OVER-HEAD | | DOOR, THEN THE ELECTRICAL SERVICE WILL | | HAVE TO BE REVISED TO INCLUDE ONLY ONE | | SERVICE RISER, ONE METER. | | | | 2)IF THE WALL IS CLOSED UP TO PROVIDE | | THE PROPER TENANT SEPARATION AS REQUIRED | | FOR OCCUPANCY TYPES, THEN ONE SERVICE | | WITH TWO METERS AND TWO MAINS WOULD BE | | PERMITTED. | | | | PLEASE KNOW ANY EMERGENCY BACK UP SYSTEM | | MAY STILL BE INSTALLED AFTER EACH MAIN | | ETC. | | | | ** THIS IS CONSIDERED ONE "BUILDING" | | UNDER THE DEFINITIONS OF THE FBC. | | ONLY IF SEPARATED BY A "FIRE WALL" WOULD | | THESE BE CONSIDERED TWO SEPARATE | | BUILDINGS. PLEASE SEE "FIRE WALL" UNDER | | DEFINITIONS. | | IF CONSTRUCTION OF CLOSING IN THE WALL , | | AND CONTRUCTION OF THE EXISTING WALL, | | CEILING ETC BETWEEN THE TWO MEET THE | | "FIRE WALL" REQUIRMENTS, THEN TWO | | SEPARATE SERVICES WILL BE PERMITTED WITH | | TWO SEPARATE OPT STAND-BY GENERATOR | | SYSTEMS. | | | | ** PLEASE KNOW, A MEETING SHOULD BE HELD | | TO GO COMMENTS, DESIGN ETC BEFORE | | RESUBMITTING PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | PLANS WERE ROUTED TO MR ROBERT BROWN | | AFTER THE ELECTRICAL REVIEW. | 2006-07-02 00:00:00 | SEE DEWEY PALMER WHEN PLANS COME BACK | | IN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-06-16 |
Time |
09:26 |
Rev Time |
1.30 |
Received By |
jleahy |
Date |
2006-06-16 |
Time |
07:36 |
Sent To |
|
|
Notes |
2006-06-16 00:00:00 | ON THE LAST PLAN REVIEW CHAPTER 13 OF | | THE FBC WAS REFERENCED BY THIS OFFICE. | | | | NO COMPLIANCE WITH THIS SECTION IS | | SHOWN. | | | | PLEASE SEE THE FOLLOWING SECTIONS: | | | | 13-415.1.ABC.1.1 AUTOMATIC LIGHTING | | SHUTOFF | | | | 13-415.1.ABC.1.2 SPACE CONTROL | | | | 13-415.1.ABC.1.3 ADDITIONAL CONTROLS | | | | 13-415.1.ABC.3TANDEM WIRING | | | | 13-415.1.ABC.1CALCULATION | | | | 13-415.1.CMETHOD C | | | | 13-415.2.ABC.1PERFORMANCE CALCULATION | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-04-03 |
Time |
15:57 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2006-04-03 |
Time |
15:57 |
Sent To |
|
|
Notes |
2006-04-03 00:00:00 | NEED TO EXPLAIN WHAT TYPE OF BUSINESS IS | | GOING TO RUN OUT OF THIS BAY? | | | | FROM THE DRAWINGS IT LOOKS LIKE | | AUTOMOTIVE REPAIR!!IF SO PLEASE | | APPLY THE REQUIREMENTS FROM ARTICLE 511 | | FROM THE NEC. | | | | BUILDING TO MEET THE REQUIREMENTS OF | | CHAPTER 13 OF THE FL BLDG. CODE FOR | | LIGHTING ,A/C AND EQUIPMENT. | | | | MAINS TO BE GROUPED PLEASE SHOW LOCATION | | 230.72 | | | | FOUR OF THE LIGHTING FIXTURE ARE THROUGH | | A WALL ??? SEE PAGE E1.1 | | | | NEED LOAD CALCULATIONS PER THE NEC | | 215.5, 220. | | | | NOTE 20 NEEDS TO BE CHANGED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-01-20 |
Time |
07:25 |
Rev Time |
0.30 |
Received By |
jleahy |
Date |
2006-01-20 |
Time |
07:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-09-21 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-09-21 |
Time |
11:49 |
Sent To |
|
|
Notes |
2006-09-21 00:00:00 | EVERYTHING IS O.K. PASSED | | | | RASIK CHOKSHI 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2006-07-13 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-07-13 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-07-13 |
Time |
13:19 |
Sent To |
PC |
|
Notes |
2006-07-13 00:00:00 | FAILED | | 1. SHEET D-1 SHOWS DOOR ON PUBLIC STREET | | SUNSET ROAD, DOOR ON PUBLIC STREET MAY | | NOT BE ALLOWED BY CITY. | | 2. NEED TO SHOW WATER/SEWER LINES ON | | PLAN/ELEVATION,DETAIL ETC. | | 3. PLEASE SHOW SIDE WALK, HANDYCAP | | ACCESS RAMP, ETC | | 4. NEED FLOOR ELEVATION,FLOODING | | REQUIREMENT,SFWMD APPROVAL | | 5.PLAN NEED TO BE APPROVED FROM UTILITY | | | | PLEASE CALL IF YOU NEED HELP, RASIK | | CHOKSHI 805-6723 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
7 |
Status |
P |
Date |
2007-02-23 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-23 |
Time |
19:53 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-23 |
Time |
19:53 |
Sent To |
|
|
Notes |
2007-02-23 20:01:05 | *****APPROVED***** | | | | | | REVISION #6 DATED 12/27/06;SHEET E-1.1 WAS STAMPED, | | INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-01-08 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-08 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2006-11-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-11-01 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-11-01 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2006-09-01 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-01 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-09-01 |
Time |
11:16 |
Sent To |
|
|
Notes |
2006-09-01 00:00:00 | ***PROVISO*** | | | | 1) NEW SHEETS DON'T APPEAR TO SHOW FIRE | | EXTINGUISHERS. PLEASE SHOW THE LOCATIONS | | WHEN RESUBMITTING THE PLANS FOR OTHER | | COMMENTS. | | | | 2) SINCE THIS WORK WILL BE IN PHASES, | | ALL EXIT DOORS THAT SERVE AS SUCH SHALL | | HAVE ILLUMINATED EXIT SIGNS IN PLACE. | | THIS IS NOT CLEARLY SHOWN ON PLANS. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-22 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-22 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-04-11 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-04-11 |
Time |
11:14 |
Sent To |
|
|
Notes |
2006-04-11 00:00:00 | ******DENIED****** | | | | 1) PLEASE INDICATE OCCUPANCY TYPE ON THE | | PLANS. WILL THERE BE PAINT SPRAYING OF | | VEHICLES? | | | | 2) LIFE SAFETY TO COMPLY WITH NFPA 101, | | 2003 EDITION. | | | | 3) PLEASE ILLUSTRATE REQUIRED ADDRESS ON | | BUILDING ELEVATIONS. MIMIMUM 6" ON | | CONTRASTING BACKGROUND. | | | | 4) IS BUILDING PROTECTED BY AUTOMATIC | | FIRE SPRINKLER SYSTEM. SEPARATE SHOP | | DRAWINGS AND PERMIT REQUIRED FOR | | REMODEL. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2006-01-24 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2006-01-24 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2006-01-24 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-03-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-03 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-03 |
Time |
17:40 |
Sent To |
P |
|
Notes |
2007-03-03 17:40:29 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-20 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
2007-01-31 15:56:35 | TO "COMM" BD#61 | 2007-01-20 12:36:14 | WAITING FOR "COMM" BD--REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
|
Date |
2006-11-29 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2006-11-29 |
Time |
19:57 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2006-11-29 |
Time |
19:57 |
Sent To |
E |
|
Notes |
2006-11-29 19:58:10 | SENT TO ELECTRICAL BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2006-11-29 |
Time |
18:34 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2006-11-29 |
Time |
18:34 |
Sent To |
|
|
Notes |
2006-12-08 15:20:04 | TO "COMM" BD#22 | 2006-11-29 18:34:52 | WAITING FOR "COMM" BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-04 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-04 |
Time |
14:46 |
Sent To |
|
|
Notes |
2006-10-17 13:50:04 | TO "COMM" BD#43 | 2006-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-31 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-31 |
Time |
13:51 |
Sent To |
|
|
Notes |
2006-08-09 00:00:00 | TO "COMM" BD#53 | 2006-07-31 00:00:00 | WAITING FOR "COMM" BD--NEW MECH AND | | PLUMB SHEETS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-06 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-06 |
Time |
14:17 |
Sent To |
E |
|
Notes |
2006-07-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-23 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-23 |
Time |
14:09 |
Sent To |
|
|
Notes |
2006-06-12 00:00:00 | TO "COMM" BD#49 | 2006-05-23 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-03-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-07 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-07 |
Time |
16:31 |
Sent To |
|
|
Notes |
2006-04-03 00:00:00 | TO "COMM" BD#57 | 2006-03-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-01-31 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-17 |
Time |
16:05 |
Sent To |
|
|
Notes |
2006-01-17 00:00:00 | TO "COMM" BD#11 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2006-10-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-10-27 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-10-27 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-09-18 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-09-18 |
Time |
13:00 |
Sent To |
|
|
Notes |
2006-09-18 00:00:00 | PROVISO: | | SUBMITTAL FOR THE TEXTILE DUCT & | | DIFFUSERS ARE NOT LISTED WITH UL. | | ANOTHER PRODUCT MAY HAVE TO BE SUBMITTED | | THAT MEET THE CLASS 0 (SURFACE BURNING | | CHARACTERISTICS OF ZERO) OR CLASS 1 | | (FLAME SPREAD INDEX <25 AND SMOKE | | DEVELOPED INDEX <50).THIS ISSUE MUST | | BE RESOLVED PRIOR TO INSTALLATION OF ANY | | DUCT. | | | | NON-METALIC DUCT SHALL COMPLY WITH | | 2004 FMC 603.4, DUCTS SHALL BE | | CONSTRUCTED WITH CLASS 0 OR CLASS 1 DUCT | | MATERIAL IN ACCORDANCE WITH UL 181. | | | | PLEASE NOTE, FABRIC DUCT SUBMITTED | | (PRIHODA) HAS NO UL LISTING. THE TEST | | REPORT PAGE 3 UNDER "LIMITATIONS" THERE | | IS A WARNING WHICH STATES THE FOLLOWING; | | "THIS DOCUMENT DOES NOT REPRESENT TYPE | | APPROVAL OR CERTIFICATION OF THE | | PRODUCT." | | | | | | ADDITIONAL PERMIT REQUIRED FOR THE SPRAY | | PAINT BOOTH.PLANS AND MANUFACTURER | | SUBMITTAL DATA ON FILE WITH BUILDING | | PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | E-MAIL [email protected]. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-06-14 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-06-14 |
Time |
07:11 |
Sent To |
|
|
Notes |
2006-06-14 00:00:00 | PROVISO: | | | | NO WORK TO BE PERFORMED ON ANY VEHICLE. | | THIS IS FOR STORAGE ONLY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-04-17 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-04-17 |
Time |
07:33 |
Sent To |
|
|
Notes |
2006-04-17 00:00:00 | DENIED: | | MECHANICAL PLANS WERE NOT SUBMITTED WITH | | THE INITIAL REVIEW. | | | | 1.PLEASE INDICATE WHAT TYPE OF | | BUSINESS THIS WILL BE.PLANS INDICATE | | CARS INSIDE BUSINESS.PLEASE PROVIDE | | CLARIFICATION, PARKING GARAGE, REAPIR | | GARAGE, BODY WORK OR PAINTING? | | | | 2.PLEASE NOTE, EXHAUST SHALL TERMINATE | | AS NOT TO CREATE A NUISANCE & SHALL NOT | | BE DIRECTED ONTO WALKWAYS. EXHAUST & | | INTAKE OPENINGS SHALL BE LOCATED A | | MINIMUM 10 FEET FROM LOT LINES OR | | BUILDINGS ON THE SAME LOT. | | | | 3.FRESH AIR INTAKE SHALL BE LOCATED A | | MINIMUM OF 10 FEET FROM ANY HZARDOUS OR | | NOXIOUS CONTAMINANT, SUCH AS PARKING | | LOTS, STREETS, ALLEYS OR LOADING DOCKS. | | | | 4.PLAN SHEET M-1.1 EF-3 INDICATES | | REELS FROM THE CEILING JOIST.IS THIS A | | SYSTEM THAT IS DESIGNED TO CONNECT | | DIRECTLY TO THE EXHAUST MUFFLER OF THE | | VEHICLE?PLEASE PROVIDE MANUFACTURER | | SUBMITTAL DATA. | | | | 5.PLAN SHEET M-1.2 INDICATES THE CO | | SENSORS LOW LEVEL ALARM AT 35 PPM.PER | | 2004 FMC 404.1, MECHANICAL VENTILATION | | IS NOT REQUIRED TO TO RUN CONTINUOUSLY | | WHERE THE SYSTEM IS ARRANGED TO OPERATE | | AUTOMATICALLY UPON DETECTION OF A | | CONCENTRATION OF CARBON MONOXIDE OF 25 | | PPM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
8 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-03-08 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-03-08 |
Time |
07:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-02-21 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-02-21 |
Time |
09:04 |
Sent To |
|
|
Notes |
2007-02-21 09:22:54 | DENIED; | | THE LAST APPROVED P-1 ON FILE WAS UP TO REVISION # 4 | | 9/26/06. THE NEWP-1 IS UP TO REVISION # 8. ONE SET OF | | PLANS HAS YELLOW HI-LITES AROUND ALL CHANGES NOT ON | | APPROVED PLANS. PLEASE SHOW CHANGES 5, 6, 7, AND 8 ON | | NEXT REVISION. | | 1. THE SERVICE SINK VENT CAN BE THE WET VENT FOR THE | | FLOOR DRAINS. THE DRY VENT CAN BE REMOVED FROM THE | | SANITARY RISER DIAGRAM. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2007-01-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-13 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-13 |
Time |
17:14 |
Sent To |
|
|
Notes |
2007-01-13 17:30:42 | DENIED | | REFERENCE: CITY MUNICIPAL CODE | | UTILITY DEPT STANDARDS | | | | 1. SHT P-1.1 900 GAL SAND/OIL INTERCEPTOR DETAIL. | | UTILITY STANDARDS INDICATE 3" WALLS AND 4" BOTTOM | | REQUIRED ON ALL INTERCEPTORS. (SEE ATTACHED SHEET). | | CITY CODE SECTION 90-124(7)(F) STATES "EACH INTERCEPTOR | | SHALL BE CONSTRUCTED OF STEEL REINFORCED CONCRETE. | | PLANS CALL FOR "FIBRILLATED POLYPROPLYLENE FIBER". | | DETAIL ALSO INDICATES 2.5" WALLS AND 3" BOTTOM. THIS | | DOES NOT MEET MUNICIPAL CODE OR UTILITY STANDARDS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2006-11-01 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-11-01 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-11-01 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2006-09-22 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-09-22 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-09-22 |
Time |
08:04 |
Sent To |
|
|
Notes |
2006-09-22 00:00:00 | DENIED; | | 1ADA DETAIL FOR PHASE 11 ON PAGE A-2 | | ONLY SHOWS A DETAIL OF LAVATORY. DETAIL | | OF WHOLE BATHROOM IS REQUIRED, SHOW THE | | TOILET, SHOWER, AND LAVATORY IN DETAIL. | | REQUIREMENTS FOR COMPLIANCE CAN BE | | FOUND, FBC-2004 CHAPTER 11; TOILET SEC. | | 11-4.16.1 THRU 11-4.16.6; LAVATORY | | 11-4.19.1 THRU 11-4.19.6; SHOWER DETAIL | | SECTION 11-4.21.1 THRU 11-4.21.8. | | 2.HOT WATER REQUIRED TO SERVICE SINK. | | (SHOW ON PLANS)LOCATION SIZE AND FUIL | | SORCE OF WATER HEATER. | | 3.SANITARY RISER DIAGRAM; | | A)TRENCH DRAIN AND FLOOR DRAIN SHALL | | NOT BE DOUBLE TRAPPED. SEC.1002.1 | | B)WHAT IS THE 4" VERTICAL DRAIN AND | | BACK WATER VALVE FOR? NEED MORE | | INFOREMATION. | | C)WHY IS A FLOOR DRAIN NEEDED IN THE | | FUTURE PAINT BOOTH? (SECOND | | REQUEST) | | 4. SAND INTERCEPTER; (SECOND REQUEST) | | PLANS MUST BE REVIEW AND APROVED BY THE | | UTILITY DEPARTMENT FOR SIZE AND | | LOCATION. | | THE CONTACT PERSON IS; | | LYNN MASSON | | PHONE822-2271 | | FAX 822-2279 | | E-MAIL [email protected] | | 5.PLUMBING FIXTURE REQUIREMENT TABLE FOR | | PHASE 11 IS NOT CORRECT. WORK WILL BE | | DONE IN IN THIS PART OF THE BUILDING. | | PLEASE CHANGE CLASIFICATION TO BUSINESS, | | OR CHANGE BOTH PHASES TO BUSINESS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-06-29 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-06-29 |
Time |
08:53 |
Sent To |
|
|
Notes |
2006-06-29 00:00:00 | FIXTURE CHANGE OUT ONLY. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-04-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-04-04 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-04-04 |
Time |
13:29 |
Sent To |
|
|
Notes |
2006-04-04 00:00:00 | DENIED; | | NO PLUMBING WORK SHOWN ON DRAWINGS. | | NO TYPE OF BUSINESS LISTED ON DRAWINGS. | | IF AUTOMOTIVE REPAIRS ARE TO BE DONE | | SAFTY EQUIPMENT @EYE WASH, SHOWER MAY BE | | REQUIRED. OIL OR SAND INTERSEPTOR MAY BE | | REQUIRED. SHOW COMPLIANCE TO FBC-2004 | | PLUMBING TABLE 403.1 AND CHAPTER 11 OF | | THE BUILDING CODE ACCESSIBILITY CODE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-01-25 |
Time |
07:19 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2006-01-25 |
Time |
07:19 |
Sent To |
|
|
Notes |
2006-01-25 00:00:00 | DENIED; | | NO PLUMBING SHOWN ON DRAWINGS. PLEASE | | SHOW PLUMBING WORK SCOTT MAXWELL | | PLUMBING WILL DO. | | SHOW COMPLIANCE TO FBC-2004 PLUMBING | | TABLE 403.1 (MINIMUM PLUMBING FIXTURES, | | AND FBC-2004 CHAPTER 11 . | | PLUMBING PLAN REVIEW BY | | JOHN LEECH | | 805-6695 |
|
|