Plan Review Details - Permit 06010393
Plan Review Stops For Permit 06010393
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-02 Cont ID  
Sent By alange Date 2006-03-02 Time 10:27 Rev Time 2.00
Received By alange Date 2006-03-02 Time 10:27 Sent To  
Notes
2006-03-02 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLIC
  
 ATION. PLEASE CALL (561)233-5025 FOR
 MORE INFORMATION.
  
 3.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC."R" VALUES FOR WALLS NOT
 AS ON PLANS, SIGN OWNER/AGENT.
  
 4.PRODUCT APPROVALS REQUIRED FOR
 BITUMEN ROOF AND STRAPS AND TIEDOWNS.
 ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 5.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 6.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 7.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 8.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 9.EDWARD KRANZ ENGINEER SHALL SEAL
 PLANS WITH REVISED SEAL SHOWING
 "LICENSED"
  
 10.GENERATOR SHALL BE ON A SEPERATE
 PERMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-02-08 Cont ID  
Sent By btrobaug Date 2006-02-08 Time 10:50 Rev Time 0.75
Received By btrobaug Date 2006-02-07 Time 16:24 Sent To M
Notes
2006-02-03 00:00:00 
 PROVISO
 PLEASE SUBMIT MANUFACTURERS
 SPECIFICATION FOR THE ATS AND GENERATOR
 PRIOR TO THE ROUGH ELECTRICAL
 INSPECTION. ALLOW TWO WEEKS FOR REVIEW.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-28 Cont ID  
Sent By adarroug Date 2006-01-28 Time 16:10 Rev Time 0.00
Received By adarroug Date 2006-01-28 Time 16:10 Sent To E
Notes
2006-01-28 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-02 Cont ID  
Sent By alange Date 2006-03-02 Time 10:36 Rev Time 0.00
Received By alange Date 2006-01-12 Time 11:53 Sent To  
Notes
2006-01-12 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-09 Cont ID  
Sent By tgordon Date 2006-02-09 Time 08:09 Rev Time 1.00
Received By tgordon Date 2006-02-09 Time 08:09 Sent To P
Notes
2006-02-09 00:00:00*** DENIED ***
 1)ENERGY CALCULATIONS NEED TO BE ON FORM
 600A-04 (2004) PER FBC 13-600.3.A AND
 NEED TO BE SIGNED BY OWNER/AGENT.
  
 2) ENERGY CAL'S. ARE CALLING FOR 60,000
 TOTAL BTU'S, PLANS ARE CALLING FOR
 90,800 TOTAL BTU'S, PLANS CAN NOT CALL
 FOR MORE TGAN THE ENERGY CAL'S. PLEASE
 CORRECT.
  
 3) NEED TO SHOW SENSIBLE BTU'S. ALSO, ON
 PLANS A/C SCHEDULE.
  
 4) AHU #1 CONDENSATE DRAIN CAN NOT
 DISCHARGE ON THE FRONT PORCH, PER 2004
 FBC/M 1411.3 .
  
 5) AHU #1 PROVIED RETURN AIR TO ALL
 HABITABLE ROOMS WITH DOORS, SEE NOTE #6.
  
 6)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 7) AHU #1 PLEASE SHOW IF YOU ARE USING A
 TRUNK LINE OR MIXING BOXES FOR SUPPLY
 AIR.
  
 8) AHU #2 PROVIED RETURN AIR FOR NEW
 OFFICE, KITCHEN, AND FAMILY ROOM, SEE
 NOTE #6.
  
 9) AHU #2 CAN NOT HAVE AN OPEN RETURN
 AIR PLENUM IN THE GARAGE, SEE 2004 FBC/R
 309.1.1 .
  
 10) AHU #3 ALL RETURN AIR GRILLS ABOVE
 BEDROOM DOORS ARE TO SMALL, SEE NOTE #6.
  
 11) PLEASE NOTE WHEN APPLYING FOR YOUR
 GENERATOR PERMIT. GENERATOR EXHUST MUST
 BE TEN FEET AWAY FROM ANY BUILDING
 OPENINGS (WINDOWS, DOORS, ROOF & EAVE
 VENTS), AND TEN FEET AWAY FROM ADJECENT
 BUILDING OPENS. PER 2004 FBC/M 401.5.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-02-10 Cont ID  
Sent By jleech Date 2006-02-10 Time 08:02 Rev Time 0.50
Received By jleech Date 2006-02-10 Time 08:02 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-01-28 Cont ID  
Sent By mmclean Date 2006-01-28 Time 08:58 Rev Time 0.00
Received By mmclean Date 2006-01-28 Time 08:58 Sent To I
Notes
2006-01-28 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 FENCE/GATE/WALL WITH EASEMENT APPROVAL
 FROM THE CITY OF WEST PALM BEACH UTILITY
 DEPT.WOULD NEED TO PROVIDE ALL OTHER
 RELEASES IF FENCE IS BEING BUILT &
 CLOSING OFFICE UTILITY EASEMENT IN REAR
 OF PROPERTY (2.5 U.E.).