Plan Review Details - Permit 06010368
Plan Review Stops For Permit 06010368
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-08-18 Cont ID  
Sent By mjacobs Date 2007-08-18 Time 13:53 Rev Time 0.00
Received By mjacobs Date 2007-08-18 Time 11:16 Sent To PC
Notes
2007-08-18 12:29:05BUILDING PLAN REVIEW
 PERMIT: 06100368
 ADD: 625 EL VEDADO
 CONT: ELSA LOPEZ
 TEL: (561)308-6715
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: PRIVISO.
  
 1)OK
  
 2)OK
  
 3)OK
  
 PROVISOR:
 THE NEW SETS OF PLANS HAS TO BE STAMPED BY THE COUNTY,
 FOR INPACT FEES..
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2007-07-10 Cont ID  
Sent By mjacobs Date 2007-07-10 Time 07:16 Rev Time 0.00
Received By mjacobs Date 2007-07-09 Time 10:36 Sent To PC
Notes
2007-07-09 16:02:09BUILDING PLAN REVIEW
 PERMIT: 06100368
 ADD: 625 EL VEDADO
 CONT: ELSA LOPEZ
 TEL: (561)308-6715
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 2)NOW THE PORCH IS TURNED INTO LIVING SPACE THE VALUE
 OF THE AREA SHALL BE INDICATED ON THE APPLICATION.
 NOTE: WHEN THE VALUE IS INCREASED, THERE WILL BE
 ADDITIONAL FEES PER 108.3. IF THE VALUE IS NOT INCREASE
 WE WILL ADJUST THE VALUE ACCORDINGLY.
  
 3)ON SHEET 1.1 THE PARTIAL PLAN AND THE NEW PARTIAL
 PLAN HAS CONFLICTING INFORMATION. ONE DRAWING SHOWS
 ROOMS AS EXISTING AND THE OTHER SHOWS THE SAME ROOMS AS
 EXISTING. THE ROOMS SHALL BE EITHER NEW OR EXISTING.
 CLARIFY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2007-05-30 Cont ID  
Sent By mjacobs Date 2007-05-30 Time 12:19 Rev Time 2.50
Received By mjacobs Date 2007-05-30 Time 06:56 Sent To PC
Notes
2007-05-30 12:19:51BUILDING PLAN REVIEW
 PERMIT: 06100368
 ADD: 625 ELVEDADO RD
 CONT: ELSA LOPEZ
 TEL: (561)308-6715
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: REV.
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)DUE TO THE FACT THAT THE PORCH WILL NOW BECOME
 LIVING SPACE,IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3)THE LABELING OF THE ROOMS ARE CONFUSING. MAKE SURE
 THE ROOMS ARE LABEL CORECTLY. IF THE PROJECT IS STILL
 UNDER CONSTRUCTION, EACH ROOM OF THE NEW CONSTRUCTION
 WILL TREATED AS A NEW ROOM. ROOMS WHICH ARE PART OF THE
 NEW ADDITION ARE CALLED EXISTING ROOMS, WHICH INFACT
 THEY ARE NEW ROOMS.
  
 4)SHOW THE EXTERIOR SHOWER ON THE NORTH ELEVATION
 DRAWINGS ON SHEET 2.1.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-08-21 Cont ID  
Sent By mjacobs Date 2006-08-21 Time 18:13 Rev Time 0.00
Received By mjacobs Date 2006-08-21 Time 17:04 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-17 Cont ID  
Sent By mjacobs Date 2006-06-17 Time 14:25 Rev Time 0.00
Received By mjacobs Date 2006-06-17 Time 09:11 Sent To PC
Notes
2006-06-17 00:00:00 
 1) THE CAST-CREET U LINTEL SCHEDULE ON
 SHEET A/1 IS MISSING L-17 AND L-27.
 ADJUST THE SCHEDULE TO REFLECT THE
 DRAWINGS.
  
 2) WITH THE ADDITION FO THE REAR PORCH
 THE VALUE FOR THIS APPLICATION HAS TO BE
 UPDATED . GIVE A FAIR MARKET VALUE FOR
 THE ADDITION OF THE PORCH OR WE WILL
 ADJUST THE COST USING THE MARSHALL-SWIFT
 REFERENCE BOOK. SO, IN ADDITION TO THE
 REVISION FEES ADDITIONAL FEES ARE DUE
 BASE ON THE SQUARE FOOTAGE OF THE NEW
 COVERED POACH
  
 3) R802.10.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN
 CONFORMANCE WITH SECTION R802.10.1 ,
 SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. TRUSS DESIGN DRAWINGS
 SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS
 DESIGN DRAWING SHALL BE PROVIDED WITH
 THE SHIPMENT OF TRUSSES DELIVERED TO THE
 JOBSITE.
  
 4) THE DRAWINGS WE HAVE ON FILE STATES
 THE TOTAL A/C AREA IS 2306 SQ.FT.
 HOWEVER THE NEW DRAWINGS SHOWS THE TOTAL
 A/C AREA IS 2414 SQ.FT. SHOW CLEARLY ON
 THE NEW DRAWINGS WHERE THE ADDITIONAL
 INCREASE IS.
  
 5) F.S.472.025 ALL FINAL DRAWINGS,
 PLANS, SPECIFICATIONS, PLATS, OR REPORTS
 PREPARED OR ISSUED BY THE REGISTRANT IN
 ACCORDANCE WITH MINIMUM TECHNICAL
 STANDARDS SET BY THE BOARD SHALL BE
 SIGNED BY THE REGISTRANT, DATED AND
 STAMPED WITH HIS OR HER SEAL.
 SEE SHEETS A/5-A/7.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL(561)805-6726
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-04-17 Cont ID  
Sent By mjacobs Date 2006-04-17 Time 11:55 Rev Time 0.00
Received By mjacobs Date 2006-04-17 Time 11:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-28 Cont ID  
Sent By mjacobs Date 2006-02-28 Time 10:52 Rev Time 3.00
Received By mjacobs Date 2006-02-27 Time 17:36 Sent To PC
Notes
2006-02-28 00:00:00 
 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 2) M1506.3 VENTILATION RATE.
 VENTILATION SYSTEMS SHALL BE DESIGNED TO
 HAVE THE CAPACITY TO EXHAUST THE MINIMUM
 AIR FLOW RATE DETERMINED IN ACCORDANCE
 WITH TABLE M1506.3 .
 TABLE M1506.3
 MINIMUM REQUIRED EXHAUST RATES FOR
 ONE- AND TWO-FAMILY DWELLINGS
 AREA TO BE VENTILATEDVENTILATION RATES
  
 KITCHENS100 CFM INTERMITTENT OR
 25 CFM CONTINUOUS
 BATHROOMS?TOILET ROOMSMECHANICAL
 EXHAUST CAPACITY OF
 50 CFM INTERMITTENT OR 20 CFM
 CONTINUOUS.
  
  
 R802.10.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN
 CONFORMANCE WITH SECTION R802.10.1 ,
 SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. TRUSS DESIGN DRAWINGS
 SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS
 DESIGN DRAWING SHALL BE PROVIDED WITH
 THE SHIPMENT OF TRUSSES DELIVERED TO THE
 JOBSITE
  
 4) PLEASE SEE ZONING NOTE ABOUT THE TWO
 ENTRANCE DOORS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  

Review Stop E ELECTRICAL
Rev No 10 Status P Date 2007-10-10 Cont ID  
Sent By btrobaug Date 2007-10-10 Time 13:14 Rev Time 0.00
Received By btrobaug Date 2007-10-10 Time 12:49 Sent To I
Notes
2007-10-10 13:14:16 
  
 PROVISO
  
 } 230.70 GENERAL.
 MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN
 A BUILDING OR OTHER STRUCTURE FROM THE SERVICE-ENTRANCE
 CONDUCTORSTHE AHJ HAS DETERMINED THAT "NEAREST POINT OF
 ENTRANCE? SHALL BE NO FARTHER THAN 8" OF UNPROTECTED
 CONDUCTORS.

Review Stop E ELECTRICAL
Rev No 9 Status F Date 2007-09-25 Cont ID  
Sent By btrobaug Date 2007-09-25 Time 11:11 Rev Time 0.00
Received By btrobaug Date 2007-09-25 Time 10:57 Sent To M
Notes
2007-09-25 11:11:44 
  
  
  
 NONCOMPLIANT
  
 THESE COMMENTS FROM THE PREVIOUS 8/9/07 REVIEW HAVE NOT
 BEEN ADDRESSED, AND THE SAME ELECTRICAL PLANS WERE
 RESUBMITTED.
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE RISER DIAGRAM INDICATES AN EXISTING 200 AMP
 PANEL "A" AND A NEW 150 AMP PANEL "B". THE PANEL
 SCHEDULES LIST PANEL "A" WITH A 300 AMP MAIN AND PANEL
 "B" AS A NEW 250 AMP SUB-PANEL. THE PANELS ARE RATED AT
 150 AND 200 AMPS AT THE METER LOCATION ON THE
 SITE/FLOOR PLAN. THE NEW SUB-PANEL LOCATION LISTS THE
 PANEL AS 250 AMP. CORRECTLY LABEL ALL THE SERVICE
 EQUIPMENT ON THE PLAN. 106.5, FBC AS AMENDED.
  
 2} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND
 210.52(A)(2). LOCATE SAME IN THE "NEW FAMILY ROOM", ONE
 MISSING IN THE "NEW WET BAR", AND "NEW BEDROOM", SEE
 REVIEWED PLAN FOR LOCATIONS.
  
 3} PER 210.70(B)(2)(B) "AT LEAST ONE WALL
 SWITCH,CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO
 PROVIDE ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR
 ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS" THIS IS
 MISSING IN THE "NEW PLAY ROOM".
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 8 Status F Date 2007-08-09 Cont ID  
Sent By btrobaug Date 2007-08-09 Time 08:36 Rev Time 0.00
Received By btrobaug Date 2007-08-08 Time 14:43 Sent To M
Notes
2007-08-09 08:36:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
 FBC 2004, 2002 NEC, 2002 NFPA-70. CODES EFFECTIVE FOR
 THIS PERMIT.
  
 1} THE RISER DIAGRAM INDICATES AN EXISTING 200 AMP
 PANEL "A" AND A NEW 150 AMP PANEL "B". THE PANEL
 SCHEDULES LIST PANEL "A" WITH A 300 AMP MAIN AND PANEL
 "B" AS A NEW 250 AMP SUB-PANEL. THE PANELS ARE RATED AT
 150 AND 200 AMPS AT THE METER LOCATION ON THE
 SITE/FLOOR PLAN. THE NEW SUB-PANEL LOCATION LISTS THE
 PANEL AS 250 AMP. CORRECTLY LABEL ALL THE SERVICE
 EQUIPMENT ON THE PLAN. 106.5, FBC AS AMENDED.
  
 2} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND
 210.52(A)(2). LOCATE SAME IN THE "NEW FAMILY ROOM", ONE
 MISSING IN THE "NEW WET BAR", AND "NEW BEDROOM", SEE
 REVIEWED PLAN FOR LOCATIONS.
  
 3} PER 210.70(B)(2)(B) "AT LEAST ONE WALL
 SWITCH?CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO
 PROVIDE ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR
 ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS" THIS IS
 MISSING IN THE "NEW PLAY ROOM".
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2007-06-27 Cont ID  
Sent By btrobaug Date 2007-06-27 Time 16:37 Rev Time 0.00
Received By btrobaug Date 2007-06-27 Time 13:51 Sent To  
Notes
2007-06-27 15:01:07 
 REVISION DENIED
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 1} CHANGE THE SHEET NUMBER TO A/5 AS THAT IS THE
 ORIGINAL AND LAST REVISED SHEET NUMBER. SHEET A/5 CAN'T
 BE REPLACED BY E.1. REMOVE THE PLUMBING REVISION AND
 PUT IT ON THE PROPERLY NUMBERED (SEE PERMITTED SET).
 PUT THE RISER AND ALL PERTINENT INFORMATION THAT WAS
 OMITTED FROM THIS REVISION, BACK ON SHEET A/5.
  
 2} PUT THE CORRECT DESIGNATION BACK ON THE
 PANELS(EXISTING FOR "A"AND GIVE RATING IN AMPS, AND
 NEW.FOR THE NEW PANEL "B"). ALSO VERIFY THAT PANEL "B"
 HAS BEEN RELOCATED SINCE THE PREVIOUS REVISION..
  
 3} INDICATE THE DEVICE AND LIGHTING LOCATIONS THAT WERE
 PART OF THE ORIGINAL SCOPE OF WORK.
  
 4} THE PARLOR MUST COMPLY WITH 210.52 RECEPTACLE
 SPACING SPACING REQUIREMENTS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2007-05-10 Cont ID  
Sent By btrobaug Date 2007-05-10 Time 13:33 Rev Time 0.50
Received By btrobaug Date 2007-05-10 Time 12:42 Sent To M
Notes
2007-05-10 13:33:15 
  
 REVISION DENIED
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 1} EGRESS LIGHTING IS REQUIRED PER
 210.70(A)(2)(B).PLEASE ADD TO PLAN.
  
 2} THE RVISED PLANS SHOW ADDITION AS "EXISTING", PLEASE
 CORRECT TO INDICATE THE SCOPE OF WORK UNDER THE PERMIT
 PULLED,
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-09-05 Cont ID  
Sent By btrobaug Date 2006-09-05 Time 07:13 Rev Time 0.50
Received By btrobaug Date 2006-09-05 Time 06:49 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-08-08 Cont ID  
Sent By btrobaug Date 2006-08-08 Time 13:00 Rev Time 0.50
Received By btrobaug Date 2006-08-08 Time 09:34 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-06-14 Cont ID  
Sent By btrobaug Date 2006-06-14 Time 17:41 Rev Time 0.50
Received By btrobaug Date 2006-06-13 Time 06:36 Sent To P
Notes
2006-06-14 00:00:00 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR
 THE DESIGN MUST PRINT AND SIGN THEIR
 NAME TO SAME PER 106.3.4.2. SEE A/5 &
 A/6.
  
 2} INDICATE THE AIC RATING OF THE
 DISCONNECT. THIS IS THE FIRST MEANS AND
 THE CORRECT AIC FOR THE BREAKERS IS MOST
 CRITICAL HERE.
  
 3} INDICATE THE SERVICE CONDUCTOR SIZE
 AND TYPE. 4/0 MIN PER 310.15(B)(5).
  
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-12 Cont ID  
Sent By btrobaug Date 2006-04-12 Time 15:38 Rev Time 0.50
Received By btrobaug Date 2006-04-12 Time 15:11 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-30 Cont ID  
Sent By btrobaug Date 2006-01-30 Time 18:12 Rev Time 0.50
Received By btrobaug Date 2006-01-30 Time 17:30 Sent To M
Notes
2006-01-30 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE A/C CALCULATIONS ON SHEET A/5 DO
 NOT MATCH THE MECHANICAL SPEC'S ON SHEET
 A/7.
  
 2} RECEPTACLE SPACING DOES NOT COMPLY
 WITH 210.52(A)(1)&(2) IN ANY ROOM OF THE
 ADDITION. SEE REVIEWED SET OF PLANS FOR
 EXAMPLES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 09:50 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 09:50 Sent To E
Notes
2007-10-05 09:50:58TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-14 Time 10:57 Rev Time 0.00
Received By adarroug Date 2007-09-14 Time 10:57 Sent To E
Notes
2007-09-14 10:57:44TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-08-07 Cont ID  
Sent By mmiller Date 2007-08-07 Time 17:17 Rev Time 0.00
Received By mmiller Date 2007-08-07 Time 17:16 Sent To E
Notes
2007-08-07 17:17:13SENT TO "BT" DESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-06-22 Cont ID  
Sent By adarroug Date 2007-06-22 Time 16:23 Rev Time 0.00
Received By adarroug Date 2007-06-22 Time 16:23 Sent To Z
Notes
2007-06-22 16:23:30TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-05-10 Cont ID  
Sent By adarroug Date 2007-05-10 Time 08:26 Rev Time 0.00
Received By adarroug Date 2007-05-10 Time 08:26 Sent To E
Notes
2007-05-10 08:27:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-05-07 Cont ID  
Sent By adarroug Date 2007-05-07 Time 14:13 Rev Time 0.00
Received By adarroug Date 2007-05-07 Time 14:13 Sent To Z
Notes
2007-05-07 14:14:14TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-08-28 Cont ID  
Sent By adarroug Date 2006-08-28 Time 11:10 Rev Time 0.00
Received By adarroug Date 2006-08-28 Time 11:10 Sent To E
Notes
2006-08-28 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-08-28 Cont ID  
Sent By adarroug Date 2006-08-04 Time 11:10 Rev Time 0.00
Received By adarroug Date 2006-08-04 Time 15:43 Sent To  
Notes
2006-08-04 00:00:00SENT TO "BT"/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 09:21 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 09:21 Sent To E
Notes
2006-08-01 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-06-12 Cont ID  
Sent By adarroug Date 2006-06-12 Time 10:25 Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 10:25 Sent To E
Notes
2006-06-12 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-30 Cont ID  
Sent By adarroug Date 2006-05-30 Time 14:15 Rev Time 0.00
Received By adarroug Date 2006-05-30 Time 14:15 Sent To Z
Notes
2006-05-30 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-04-04 Cont ID  
Sent By adarroug Date 2006-04-04 Time 11:19 Rev Time 0.00
Received By adarroug Date 2006-04-04 Time 11:19 Sent To E
Notes
2006-04-04 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-21 Cont ID  
Sent By dpalmer Date 2006-03-21 Time 16:20 Rev Time 0.00
Received By dpalmer Date 2006-03-21 Time 16:20 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-27 Cont ID  
Sent By adarroug Date 2006-01-27 Time 09:17 Rev Time 0.00
Received By adarroug Date 2006-01-27 Time 09:17 Sent To E
Notes
2006-01-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-02-28 Time   Rev Time 0.00
Received By adarroug Date 2006-01-12 Time 11:02 Sent To  
Notes
2006-01-12 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 10 Status P Date 2007-10-12 Cont ID  
Sent By tgordon Date 2007-10-12 Time 08:20 Rev Time 0.30
Received By tgordon Date 2007-10-12 Time 08:20 Sent To  
Notes
2007-10-12 08:21:29REVISION TO MECH. PLANS, ENERGY CAL'S. AND COOLING LOAD
 CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 9 Status F Date 2007-09-25 Cont ID  
Sent By tgordon Date 2007-09-25 Time 14:00 Rev Time 0.45
Received By tgordon Date 2007-09-25 Time 14:00 Sent To  
Notes
2007-09-25 14:02:25PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 ***REVISIONDENIED ***
 1)AS REQUESTED IN LAST TWO REVIEWS8-9-07 NOTE #1
 AND 6-28-07 NOTE #5. MECHANICAL PLAN PAGE A/7 NEEDS TO
 SHOW THE RETURN AIR GRILLS (FOR FAMILY ROOM) AND SIZE
 FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN. SEE 2004
 FBC/R M1602.4.
  
 2) AS REQUESTED IN LAST REVIEW 8-9-07 NOTE #2. SHOW ON
 MECHANICAL PLAN PAGE A/7 HOW THE RETURN AIR FROM THE
 NEW WET BAR, NEW PLAY ROOM, AND NEW BEDROOM IS GOING TO
 RETURN TO THE AIR HANDLER IF ALL DOORS ARE CLOSED. SEE
 2004 FBC/R M1602.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 8 Status F Date 2007-08-09 Cont ID  
Sent By tgordon Date 2007-08-09 Time 13:31 Rev Time 0.45
Received By tgordon Date 2007-08-09 Time 13:31 Sent To P
Notes
2007-08-09 13:33:23PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER
 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 *** REVISION DENIED ***
 1) AS REQUESTED IN LAST REVIEW 6-28-07 NOTE #5
 MECHANICAL PLAN NEEDS TO SHOW THE RETURN AIR GRILLS AND
 SIZE FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN.
  
 2) SHOW ON MECHANICAL PLAN HOW THE RETURN AIR FROM THE
 NEW WET BAR, NEW PLAY ROOM, AND NEW BEDROOM IS GOING TO
 RETURN TO THE AIR HANDLER IF ALL DOORS ARE CLOSED. SEE
 2004 FBC/R M1602.4.
  
 3) REVISED MECHANICAL PLANS SUBMITTED SHOWS ONE 5 TON
 A/C SYSTEM SERVICING THE WHOLE HOUSE, REVISED ENERGY
 CALCULATIONS STATE ONE 5 TON AND ONE 2 TON SERVICING
 THE HOUSE, THE TWO MUST COINCIDE. PLEASE CORRECT.
  
 4) PREVIOUS MECHANICAL PLANS HAD SHOWN TWO A/C SYSTEMS
 TO BE INSTALLED, THIS PLAN ONLY SHOWS ONE SYSTEM,
 PLEASE DOUBLE CHECK THE DESIGN BEFORE RE-SUBMITTING.
  
 5) BEFORE RE-SUBMITTING PLEASE CHECK THEN RE-CHECK THE
 PLANS, ENERGY CALCULATIONS, AND COOLING LOAD
 CALCULATIONS TO MAKE CERTAIN THEY ARE ACCURATE, CORRECT
 AND COINCIDE WITH EACH OTHER.
  
 6)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING
 FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL: [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 7 Status F Date 2007-06-28 Cont ID  
Sent By tgordon Date 2007-06-28 Time 11:01 Rev Time 0.35
Received By tgordon Date 2007-06-28 Time 11:01 Sent To P
Notes
2007-06-28 11:22:41** REVISION DENIED **
 1) ENERGY CALCULATIONS LINE 11 A & B SHOW THE SUPPLY
 AND RETURN AIR DUCTS IN A CONDITIONED SPACE, THE DUCTS
 ARE IN THE ATTIC AND IS UN-CONDITIONED, PLEASE
 CORRECT.
  
 2) ENERGY CALCULATIONS LINE 15 IS TAKING CREDIT FOR
 CEILING FANS THE ELECTRICAL PLANS NEED TO SHOW FANS IN
 ALL THE BEDROOMS ALSO THE EXISTING BEDROOMS, PLEASE
 CORRECT.
  
 3) PLEASE SUBMIT COOLING LOAD CALCULATIONS FOR THE 5
 TON A/C SYSTEM ALSO, AS THE ZONES HAVE CHANGED.
  
 4) SEE MECHANICAL PLANS PAGE M/1 "A/C NOTES" STATE PALM
 BEACH COUNTY, THIS IS THE CITY OF WEST PALM BEACH,
 PLEASE CORRECT PLAN.
  
 5) MECHANICAL PLAN NEEDS TO SHOW THE RETURN AIR GRILLS
 AND SIZE FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN.
  
 6) PLEASE SHOW THE LOCATION OF BOTH A/C CONDENSER UNITS
 ON THE MECHANICAL PLANS, AND LABEL THEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2007-05-11 Cont ID  
Sent By tgordon Date 2007-05-11 Time 10:43 Rev Time 2.00
Received By tgordon Date 2007-05-11 Time 10:43 Sent To P
Notes
2007-05-11 11:06:31 
 *** REVISION DENIED ***
 1) REVISED PLANS ARE SHOWING THE ORIGINAL ADDITION AS
 EXISTING, THIS IS NOT EXISTING AS IT IS STILL PART OF
 THIS PERMIT, PLEASE CORRECT ALL PLANS.
  
 2) A/C DUCTS HAVE BEEN REMOVED FROM THE ORIGINAL
 ADDITION, PLEASE CORRECT AS THEY ARE STILL PART OF THE
 PERMIT.
  
 3) SHOW ON MECHANICAL PLANS HOW RETURN AIR IS GETTING
 BACK TO THE AIR HANDLER FROM ALL REQUIRED SPACES.
  
 4) BATHROOM EXHAUST FANS HAVE BEEN REMOVED FROM
 BATHROOMS, PLEASE CORRECT.
  
 5) COOLING LOAD CALCULATIONS NEED TO BE RE-CALCULATED
 AS THEY ARE SHOWING THE WRONG AREA AND VOLUME, NEED TO
 BE CALCULATED FOR THE TOTAL ADDITION NOT INCLUDING THE
 ORIGINAL HOUSE.
  
 6) ENERGY CALCULATIONS NEED TO BE RE-DONE FOR THE SAME
 REASON
  
 7) SEE MECHANICAL PLANS A/C NOTES: ARE REFERRING TO
 PALM BEACH COUNTY, PLEASE CORRECT TO SHOW CITY OF WEST
 PALM BEACH.
  
 8) SEE MECHANICAL PLANS TOTAL AREA, PLEASE CORRECT TO
 SHOW AREAS UNDER THIS PERMIT
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729. .

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2006-09-05 Cont ID  
Sent By tgordon Date 2006-09-05 Time 09:32 Rev Time 0.30
Received By tgordon Date 2006-09-05 Time 09:32 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2006-08-21 Cont ID  
Sent By tgordon Date 2006-08-21 Time 08:57 Rev Time 0.25
Received By tgordon Date 2006-08-21 Time 08:57 Sent To B
Notes
2006-08-21 00:00:00*** DENIED ***
 1) REVISED ENERGY CALCULATIONS WERE NOT
 RE-SUBMITTED.
  
 2) PROVIED RETURN AIR TO EXISTING DINING
 ROOM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-06-16 Cont ID  
Sent By tgordon Date 2006-06-16 Time 11:25 Rev Time 0.35
Received By tgordon Date 2006-06-16 Time 11:25 Sent To B
Notes
2006-06-16 00:00:00REVISION TO MECH. PLANS AND E-CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-04-12 Cont ID  
Sent By tgordon Date 2006-04-12 Time 15:56 Rev Time 0.30
Received By tgordon Date 2006-04-12 Time 15:56 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-01-31 Cont ID  
Sent By tgordon Date 2006-01-31 Time 12:12 Rev Time 0.30
Received By tgordon Date 2006-01-31 Time 12:12 Sent To P
Notes
2006-01-31 00:00:00*** DENIED ***
 1)ENERGY CALCULATIONS NEED TO BE ON FORM
 600A-04 (2004) PER FBC 13-600.3.A .
  
 2) NEED MAR MEK INC. OR NELSON MARIN'S
 LICENSE NUMBER ON MECHANICAL PLANS.
  
 3) NO RETURN AIR IS PROVIDED FOR NEW
 FAMILY ROOM.
  
 4) NEED TO SHOW SIZE OF THE RETURN AIR
 GRILL IN THE NEW PARLOR BEHIND DOOR.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 7 Status P Date 2007-08-15 Cont ID  
Sent By jleech Date 2007-08-15 Time 11:03 Rev Time 0.00
Received By jleech Date 2007-08-15 Time 11:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status F Date 2007-07-03 Cont ID  
Sent By jleech Date 2007-07-03 Time 15:12 Rev Time 0.00
Received By jleech Date 2007-07-03 Time 15:07 Sent To B
Notes
2007-07-03 15:23:49DENIED;
 NEW RISER DIAGRAM DOES NOT SHOW THE 2 BATHROOMS ADDED
 TO THE NEW ADDITION. SEE APPROVED PLANS. DO YOU HAVE 2
 WASHER AND DRYERS, OR WAS THE OLD ONE DELETED?
 APPROVED PLANS SHOW A 3RD BATHROOM WAS THAT BATHROOM
 DELETED? IF SO PLEASENOTE ON PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 5 Status F Date 2007-05-23 Cont ID  
Sent By jleech Date 2007-05-23 Time 07:35 Rev Time 0.00
Received By jleech Date 2007-05-23 Time 07:25 Sent To B
Notes
2007-05-23 07:33:42DENIED;
 1. THE APPROVED PLANS SHOWS NEW BATHROOMS ETC. REVISION
 SHOWS BATHROOMS AS EXISTING. SHOW SANITARY RISER
 DIAGRAM AS APPROVED WITH CHANGES CLOUDED.
 2. THE OUTSIDE SHOWER CAN NOT GO TO SANITARY. THE WATER
 FROM THIS SHOWER SHOULD GO TO A GRASSY AREA OR TO A
 FRENCH DRAIN. IF DRAIN GO TO FRENCH DRAIN PLEASE SHOW
 DETAIL.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-08-19 Cont ID  
Sent By pschmitz Date 2006-08-19 Time 06:23 Rev Time 0.00
Received By pschmitz Date 2006-08-19 Time 06:22 Sent To M
Notes
2006-08-19 00:00:00REVISION

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-06-15 Cont ID  
Sent By jleech Date 2006-06-15 Time 12:42 Rev Time 0.00
Received By jleech Date 2006-06-15 Time 12:42 Sent To M
Notes
2006-06-15 00:00:00DENIED;
 PERSON RESPONSIBLE FOR DRAWINGS MUST
 PRINT AND SIGN THEIRNAME TO SAME.
 106.3.4.3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-04-13 Cont ID  
Sent By jleech Date 2006-04-13 Time 08:30 Rev Time 0.00
Received By jleech Date 2006-04-13 Time 08:30 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-02 Cont ID  
Sent By jleech Date 2006-02-02 Time 07:46 Rev Time 0.33
Received By jleech Date 2006-02-02 Time 07:46 Sent To B
Notes
2006-02-02 00:00:00DELETE;
 1.W/M MUST DISCHARGE DOWN STREAM OF THE
 1/2 BATH FBC-2004 PLUMBING SEC. 909.1.
 2.CHANGE NOTE 1 TO FBC-2004 CODE.
 3.MASTER BATHROOM TUB AND SHOWER ARE NOT
 VENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 5 Status P Date 2007-06-25 Cont ID  
Sent By choops Date 2007-06-25 Time 12:46 Rev Time 0.00
Received By choops Date 2007-06-25 Time 12:45 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2007-05-08 Cont ID  
Sent By choops Date 2007-05-08 Time 17:34 Rev Time 0.00
Received By choops Date 2007-05-08 Time 17:34 Sent To I
Notes
2007-05-08 17:35:56***FAILED***
  
  
 1)PLEASE PROVIDE ELEVATION FROM GRADE TO MIDPOINT OF
 ROOF'S PITCH.
  
 2)DRIVEWAY MUST HAVE SEPERATE PERMIT
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720

Review Stop Z ZONING
Rev No 3 Status P Date 2006-06-10 Cont ID  
Sent By mmclean Date 2006-06-10 Time 10:09 Rev Time 0.00
Received By mmclean Date 2006-06-10 Time 10:09 Sent To I
Notes
2006-06-10 00:00:00NEW PLANS:
 NOTE: THE PROPOSED ADDITION (NEW WET
 BAR) MUST NOT BE USED AS A SEPERATE
 KITCHEN (ONLY ONE COOKING FACILITY
 ALLOWED)
  
 SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-04-03 Cont ID  
Sent By mmclean Date 2006-04-03 Time 15:00 Rev Time 0.00
Received By mmclean Date 2006-04-03 Time 15:00 Sent To I
Notes
2006-04-03 00:00:00NOTE: THE PROPOSED ADDITON SITS BEYOND
 THE 25FT FRONT SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-23 Cont ID  
Sent By mmclean Date 2006-01-23 Time 14:22 Rev Time 0.00
Received By mmclean Date 2006-01-23 Time 14:22 Sent To B
Notes
2006-01-26 00:00:00DENIED,
 1. CANNOT HAVE TWO FRONT DOOR ENTRANCES.
 2. NEED TO PROVIDE THE SETBACK (SIDE0
 FOR THE PROPOSED ADDITION.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720