Plan Review Stops For Permit 06010368 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2007-08-18 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-18 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-18 |
Time |
11:16 |
Sent To |
PC |
|
Notes |
2007-08-18 12:29:05 | BUILDING PLAN REVIEW | | PERMIT: 06100368 | | ADD: 625 EL VEDADO | | CONT: ELSA LOPEZ | | TEL: (561)308-6715 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 2ND | | ACTION: PRIVISO. | | | | 1)OK | | | | 2)OK | | | | 3)OK | | | | PROVISOR: | | THE NEW SETS OF PLANS HAS TO BE STAMPED BY THE COUNTY, | | FOR INPACT FEES.. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-07-10 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-07-09 |
Time |
10:36 |
Sent To |
PC |
|
Notes |
2007-07-09 16:02:09 | BUILDING PLAN REVIEW | | PERMIT: 06100368 | | ADD: 625 EL VEDADO | | CONT: ELSA LOPEZ | | TEL: (561)308-6715 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 2ND | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | 2)NOW THE PORCH IS TURNED INTO LIVING SPACE THE VALUE | | OF THE AREA SHALL BE INDICATED ON THE APPLICATION. | | NOTE: WHEN THE VALUE IS INCREASED, THERE WILL BE | | ADDITIONAL FEES PER 108.3. IF THE VALUE IS NOT INCREASE | | WE WILL ADJUST THE VALUE ACCORDINGLY. | | | | 3)ON SHEET 1.1 THE PARTIAL PLAN AND THE NEW PARTIAL | | PLAN HAS CONFLICTING INFORMATION. ONE DRAWING SHOWS | | ROOMS AS EXISTING AND THE OTHER SHOWS THE SAME ROOMS AS | | EXISTING. THE ROOMS SHALL BE EITHER NEW OR EXISTING. | | CLARIFY. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2007-05-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-05-30 |
Time |
12:19 |
Rev Time |
2.50 |
Received By |
mjacobs |
Date |
2007-05-30 |
Time |
06:56 |
Sent To |
PC |
|
Notes |
2007-05-30 12:19:51 | BUILDING PLAN REVIEW | | PERMIT: 06100368 | | ADD: 625 ELVEDADO RD | | CONT: ELSA LOPEZ | | TEL: (561)308-6715 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: REV. | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2)DUE TO THE FACT THAT THE PORCH WILL NOW BECOME | | LIVING SPACE,IMPACT FEES MUST BE PAID TO PALM BEACH | | COUNTY. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 3)THE LABELING OF THE ROOMS ARE CONFUSING. MAKE SURE | | THE ROOMS ARE LABEL CORECTLY. IF THE PROJECT IS STILL | | UNDER CONSTRUCTION, EACH ROOM OF THE NEW CONSTRUCTION | | WILL TREATED AS A NEW ROOM. ROOMS WHICH ARE PART OF THE | | NEW ADDITION ARE CALLED EXISTING ROOMS, WHICH INFACT | | THEY ARE NEW ROOMS. | | | | 4)SHOW THE EXTERIOR SHOWER ON THE NORTH ELEVATION | | DRAWINGS ON SHEET 2.1. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-08-21 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-08-21 |
Time |
17:04 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-06-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-06-17 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-06-17 |
Time |
09:11 |
Sent To |
PC |
|
Notes |
2006-06-17 00:00:00 | | | 1) THE CAST-CREET U LINTEL SCHEDULE ON | | SHEET A/1 IS MISSING L-17 AND L-27. | | ADJUST THE SCHEDULE TO REFLECT THE | | DRAWINGS. | | | | 2) WITH THE ADDITION FO THE REAR PORCH | | THE VALUE FOR THIS APPLICATION HAS TO BE | | UPDATED . GIVE A FAIR MARKET VALUE FOR | | THE ADDITION OF THE PORCH OR WE WILL | | ADJUST THE COST USING THE MARSHALL-SWIFT | | REFERENCE BOOK. SO, IN ADDITION TO THE | | REVISION FEES ADDITIONAL FEES ARE DUE | | BASE ON THE SQUARE FOOTAGE OF THE NEW | | COVERED POACH | | | | 3) R802.10.1 TRUSS DESIGN DRAWINGS. | | TRUSS DESIGN DRAWINGS, PREPARED IN | | CONFORMANCE WITH SECTION R802.10.1 , | | SHALL BE PROVIDED TO THE BUILDING | | OFFICIAL AND APPROVED PRIOR TO | | INSTALLATION. TRUSS DESIGN DRAWINGS | | SHALL INCLUDE, AT A MINIMUM, THE | | INFORMATION SPECIFIED BELOW. TRUSS | | DESIGN DRAWING SHALL BE PROVIDED WITH | | THE SHIPMENT OF TRUSSES DELIVERED TO THE | | JOBSITE. | | | | 4) THE DRAWINGS WE HAVE ON FILE STATES | | THE TOTAL A/C AREA IS 2306 SQ.FT. | | HOWEVER THE NEW DRAWINGS SHOWS THE TOTAL | | A/C AREA IS 2414 SQ.FT. SHOW CLEARLY ON | | THE NEW DRAWINGS WHERE THE ADDITIONAL | | INCREASE IS. | | | | 5) F.S.472.025 ALL FINAL DRAWINGS, | | PLANS, SPECIFICATIONS, PLATS, OR REPORTS | | PREPARED OR ISSUED BY THE REGISTRANT IN | | ACCORDANCE WITH MINIMUM TECHNICAL | | STANDARDS SET BY THE BOARD SHALL BE | | SIGNED BY THE REGISTRANT, DATED AND | | STAMPED WITH HIS OR HER SEAL. | | SEE SHEETS A/5-A/7. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL(561)805-6726 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-04-17 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-04-17 |
Time |
11:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-02-28 |
Time |
10:52 |
Rev Time |
3.00 |
Received By |
mjacobs |
Date |
2006-02-27 |
Time |
17:36 |
Sent To |
PC |
|
Notes |
2006-02-28 00:00:00 | | | 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | 2004 SHALL BE DESIGNED TO THE 2004 | | FLORIDA BUILDING CODE. | | | | 2) M1506.3 VENTILATION RATE. | | VENTILATION SYSTEMS SHALL BE DESIGNED TO | | HAVE THE CAPACITY TO EXHAUST THE MINIMUM | | AIR FLOW RATE DETERMINED IN ACCORDANCE | | WITH TABLE M1506.3 . | | TABLE M1506.3 | | MINIMUM REQUIRED EXHAUST RATES FOR | | ONE- AND TWO-FAMILY DWELLINGS | | AREA TO BE VENTILATEDVENTILATION RATES | | | | KITCHENS100 CFM INTERMITTENT OR | | 25 CFM CONTINUOUS | | BATHROOMS?TOILET ROOMSMECHANICAL | | EXHAUST CAPACITY OF | | 50 CFM INTERMITTENT OR 20 CFM | | CONTINUOUS. | | | | | | R802.10.1 TRUSS DESIGN DRAWINGS. | | TRUSS DESIGN DRAWINGS, PREPARED IN | | CONFORMANCE WITH SECTION R802.10.1 , | | SHALL BE PROVIDED TO THE BUILDING | | OFFICIAL AND APPROVED PRIOR TO | | INSTALLATION. TRUSS DESIGN DRAWINGS | | SHALL INCLUDE, AT A MINIMUM, THE | | INFORMATION SPECIFIED BELOW. TRUSS | | DESIGN DRAWING SHALL BE PROVIDED WITH | | THE SHIPMENT OF TRUSSES DELIVERED TO THE | | JOBSITE | | | | 4) PLEASE SEE ZONING NOTE ABOUT THE TWO | | ENTRANCE DOORS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
10 |
Status |
P |
Date |
2007-10-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-10-10 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-10-10 |
Time |
12:49 |
Sent To |
I |
|
Notes |
2007-10-10 13:14:16 | | | | | PROVISO | | | | } 230.70 GENERAL. | | MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN | | A BUILDING OR OTHER STRUCTURE FROM THE SERVICE-ENTRANCE | | CONDUCTORSTHE AHJ HAS DETERMINED THAT "NEAREST POINT OF | | ENTRANCE? SHALL BE NO FARTHER THAN 8" OF UNPROTECTED | | CONDUCTORS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
9 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-09-25 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-09-25 |
Time |
10:57 |
Sent To |
M |
|
Notes |
2007-09-25 11:11:44 | | | | | | | | | NONCOMPLIANT | | | | THESE COMMENTS FROM THE PREVIOUS 8/9/07 REVIEW HAVE NOT | | BEEN ADDRESSED, AND THE SAME ELECTRICAL PLANS WERE | | RESUBMITTED. | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | 1} THE RISER DIAGRAM INDICATES AN EXISTING 200 AMP | | PANEL "A" AND A NEW 150 AMP PANEL "B". THE PANEL | | SCHEDULES LIST PANEL "A" WITH A 300 AMP MAIN AND PANEL | | "B" AS A NEW 250 AMP SUB-PANEL. THE PANELS ARE RATED AT | | 150 AND 200 AMPS AT THE METER LOCATION ON THE | | SITE/FLOOR PLAN. THE NEW SUB-PANEL LOCATION LISTS THE | | PANEL AS 250 AMP. CORRECTLY LABEL ALL THE SERVICE | | EQUIPMENT ON THE PLAN. 106.5, FBC AS AMENDED. | | | | 2} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | 210.52(A)(2). LOCATE SAME IN THE "NEW FAMILY ROOM", ONE | | MISSING IN THE "NEW WET BAR", AND "NEW BEDROOM", SEE | | REVIEWED PLAN FOR LOCATIONS. | | | | 3} PER 210.70(B)(2)(B) "AT LEAST ONE WALL | | SWITCH,CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO | | PROVIDE ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR | | ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS" THIS IS | | MISSING IN THE "NEW PLAY ROOM". | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-08-09 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-08-08 |
Time |
14:43 |
Sent To |
M |
|
Notes |
2007-08-09 08:36:00 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | FBC 2004, 2002 NEC, 2002 NFPA-70. CODES EFFECTIVE FOR | | THIS PERMIT. | | | | 1} THE RISER DIAGRAM INDICATES AN EXISTING 200 AMP | | PANEL "A" AND A NEW 150 AMP PANEL "B". THE PANEL | | SCHEDULES LIST PANEL "A" WITH A 300 AMP MAIN AND PANEL | | "B" AS A NEW 250 AMP SUB-PANEL. THE PANELS ARE RATED AT | | 150 AND 200 AMPS AT THE METER LOCATION ON THE | | SITE/FLOOR PLAN. THE NEW SUB-PANEL LOCATION LISTS THE | | PANEL AS 250 AMP. CORRECTLY LABEL ALL THE SERVICE | | EQUIPMENT ON THE PLAN. 106.5, FBC AS AMENDED. | | | | 2} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | 210.52(A)(2). LOCATE SAME IN THE "NEW FAMILY ROOM", ONE | | MISSING IN THE "NEW WET BAR", AND "NEW BEDROOM", SEE | | REVIEWED PLAN FOR LOCATIONS. | | | | 3} PER 210.70(B)(2)(B) "AT LEAST ONE WALL | | SWITCH?CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO | | PROVIDE ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR | | ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS" THIS IS | | MISSING IN THE "NEW PLAY ROOM". | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-06-27 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-06-27 |
Time |
13:51 |
Sent To |
|
|
Notes |
2007-06-27 15:01:07 | | | REVISION DENIED | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | 1} CHANGE THE SHEET NUMBER TO A/5 AS THAT IS THE | | ORIGINAL AND LAST REVISED SHEET NUMBER. SHEET A/5 CAN'T | | BE REPLACED BY E.1. REMOVE THE PLUMBING REVISION AND | | PUT IT ON THE PROPERLY NUMBERED (SEE PERMITTED SET). | | PUT THE RISER AND ALL PERTINENT INFORMATION THAT WAS | | OMITTED FROM THIS REVISION, BACK ON SHEET A/5. | | | | 2} PUT THE CORRECT DESIGNATION BACK ON THE | | PANELS(EXISTING FOR "A"AND GIVE RATING IN AMPS, AND | | NEW.FOR THE NEW PANEL "B"). ALSO VERIFY THAT PANEL "B" | | HAS BEEN RELOCATED SINCE THE PREVIOUS REVISION.. | | | | 3} INDICATE THE DEVICE AND LIGHTING LOCATIONS THAT WERE | | PART OF THE ORIGINAL SCOPE OF WORK. | | | | 4} THE PARLOR MUST COMPLY WITH 210.52 RECEPTACLE | | SPACING SPACING REQUIREMENTS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2007-05-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-05-10 |
Time |
13:33 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-05-10 |
Time |
12:42 |
Sent To |
M |
|
Notes |
2007-05-10 13:33:15 | | | | | REVISION DENIED | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | 1} EGRESS LIGHTING IS REQUIRED PER | | 210.70(A)(2)(B).PLEASE ADD TO PLAN. | | | | 2} THE RVISED PLANS SHOW ADDITION AS "EXISTING", PLEASE | | CORRECT TO INDICATE THE SCOPE OF WORK UNDER THE PERMIT | | PULLED, | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-05 |
Time |
07:13 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-09-05 |
Time |
06:49 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-08 |
Time |
13:00 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-08-08 |
Time |
09:34 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-14 |
Time |
17:41 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-06-13 |
Time |
06:36 |
Sent To |
P |
|
Notes |
2006-06-14 00:00:00 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR | | THE DESIGN MUST PRINT AND SIGN THEIR | | NAME TO SAME PER 106.3.4.2. SEE A/5 & | | A/6. | | | | 2} INDICATE THE AIC RATING OF THE | | DISCONNECT. THIS IS THE FIRST MEANS AND | | THE CORRECT AIC FOR THE BREAKERS IS MOST | | CRITICAL HERE. | | | | 3} INDICATE THE SERVICE CONDUCTOR SIZE | | AND TYPE. 4/0 MIN PER 310.15(B)(5). | | | | | | WILLIAM R. TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | CONSTRUCTION SERVICES DEPARTMENT | | 561) 805-6718 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-04-12 |
Time |
15:38 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-04-12 |
Time |
15:11 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-01-30 |
Time |
18:12 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-01-30 |
Time |
17:30 |
Sent To |
M |
|
Notes |
2006-01-30 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE A/C CALCULATIONS ON SHEET A/5 DO | | NOT MATCH THE MECHANICAL SPEC'S ON SHEET | | A/7. | | | | 2} RECEPTACLE SPACING DOES NOT COMPLY | | WITH 210.52(A)(1)&(2) IN ANY ROOM OF THE | | ADDITION. SEE REVIEWED SET OF PLANS FOR | | EXAMPLES. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2007-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-05 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-05 |
Time |
09:50 |
Sent To |
E |
|
Notes |
2007-10-05 09:50:58 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-14 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-14 |
Time |
10:57 |
Sent To |
E |
|
Notes |
2007-09-14 10:57:44 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2007-08-07 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-08-07 |
Time |
17:16 |
Sent To |
E |
|
Notes |
2007-08-07 17:17:13 | SENT TO "BT" DESK MMILLER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-22 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-22 |
Time |
16:23 |
Sent To |
Z |
|
Notes |
2007-06-22 16:23:30 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2007-05-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-10 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-10 |
Time |
08:26 |
Sent To |
E |
|
Notes |
2007-05-10 08:27:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-05-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-07 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-07 |
Time |
14:13 |
Sent To |
Z |
|
Notes |
2007-05-07 14:14:14 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-08-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-28 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-28 |
Time |
11:10 |
Sent To |
E |
|
Notes |
2006-08-28 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-08-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-04 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-04 |
Time |
15:43 |
Sent To |
|
|
Notes |
2006-08-04 00:00:00 | SENT TO "BT"/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-01 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-01 |
Time |
09:21 |
Sent To |
E |
|
Notes |
2006-08-01 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-12 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-12 |
Time |
10:25 |
Sent To |
E |
|
Notes |
2006-06-12 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-30 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-30 |
Time |
14:15 |
Sent To |
Z |
|
Notes |
2006-05-30 00:00:00 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-04-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-04 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-04 |
Time |
11:19 |
Sent To |
E |
|
Notes |
2006-04-04 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-21 |
Time |
16:20 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-27 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-27 |
Time |
09:17 |
Sent To |
E |
|
Notes |
2006-01-27 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-02-28 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-12 |
Time |
11:02 |
Sent To |
|
|
Notes |
2006-01-12 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
10 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-12 |
Time |
08:20 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-10-12 |
Time |
08:20 |
Sent To |
|
|
Notes |
2007-10-12 08:21:29 | REVISION TO MECH. PLANS, ENERGY CAL'S. AND COOLING LOAD | | CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
9 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-09-25 |
Time |
14:00 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-09-25 |
Time |
14:00 |
Sent To |
|
|
Notes |
2007-09-25 14:02:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | ***REVISIONDENIED *** | | 1)AS REQUESTED IN LAST TWO REVIEWS8-9-07 NOTE #1 | | AND 6-28-07 NOTE #5. MECHANICAL PLAN PAGE A/7 NEEDS TO | | SHOW THE RETURN AIR GRILLS (FOR FAMILY ROOM) AND SIZE | | FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN. SEE 2004 | | FBC/R M1602.4. | | | | 2) AS REQUESTED IN LAST REVIEW 8-9-07 NOTE #2. SHOW ON | | MECHANICAL PLAN PAGE A/7 HOW THE RETURN AIR FROM THE | | NEW WET BAR, NEW PLAY ROOM, AND NEW BEDROOM IS GOING TO | | RETURN TO THE AIR HANDLER IF ALL DOORS ARE CLOSED. SEE | | 2004 FBC/R M1602.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
8 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-09 |
Time |
13:31 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-08-09 |
Time |
13:31 |
Sent To |
P |
|
Notes |
2007-08-09 13:33:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | *** REVISION DENIED *** | | 1) AS REQUESTED IN LAST REVIEW 6-28-07 NOTE #5 | | MECHANICAL PLAN NEEDS TO SHOW THE RETURN AIR GRILLS AND | | SIZE FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN. | | | | 2) SHOW ON MECHANICAL PLAN HOW THE RETURN AIR FROM THE | | NEW WET BAR, NEW PLAY ROOM, AND NEW BEDROOM IS GOING TO | | RETURN TO THE AIR HANDLER IF ALL DOORS ARE CLOSED. SEE | | 2004 FBC/R M1602.4. | | | | 3) REVISED MECHANICAL PLANS SUBMITTED SHOWS ONE 5 TON | | A/C SYSTEM SERVICING THE WHOLE HOUSE, REVISED ENERGY | | CALCULATIONS STATE ONE 5 TON AND ONE 2 TON SERVICING | | THE HOUSE, THE TWO MUST COINCIDE. PLEASE CORRECT. | | | | 4) PREVIOUS MECHANICAL PLANS HAD SHOWN TWO A/C SYSTEMS | | TO BE INSTALLED, THIS PLAN ONLY SHOWS ONE SYSTEM, | | PLEASE DOUBLE CHECK THE DESIGN BEFORE RE-SUBMITTING. | | | | 5) BEFORE RE-SUBMITTING PLEASE CHECK THEN RE-CHECK THE | | PLANS, ENERGY CALCULATIONS, AND COOLING LOAD | | CALCULATIONS TO MAKE CERTAIN THEY ARE ACCURATE, CORRECT | | AND COINCIDE WITH EACH OTHER. | | | | 6)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING | | FOUR TIMES THE FEE. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL: [email protected]. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-28 |
Time |
11:01 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2007-06-28 |
Time |
11:01 |
Sent To |
P |
|
Notes |
2007-06-28 11:22:41 | ** REVISION DENIED ** | | 1) ENERGY CALCULATIONS LINE 11 A & B SHOW THE SUPPLY | | AND RETURN AIR DUCTS IN A CONDITIONED SPACE, THE DUCTS | | ARE IN THE ATTIC AND IS UN-CONDITIONED, PLEASE | | CORRECT. | | | | 2) ENERGY CALCULATIONS LINE 15 IS TAKING CREDIT FOR | | CEILING FANS THE ELECTRICAL PLANS NEED TO SHOW FANS IN | | ALL THE BEDROOMS ALSO THE EXISTING BEDROOMS, PLEASE | | CORRECT. | | | | 3) PLEASE SUBMIT COOLING LOAD CALCULATIONS FOR THE 5 | | TON A/C SYSTEM ALSO, AS THE ZONES HAVE CHANGED. | | | | 4) SEE MECHANICAL PLANS PAGE M/1 "A/C NOTES" STATE PALM | | BEACH COUNTY, THIS IS THE CITY OF WEST PALM BEACH, | | PLEASE CORRECT PLAN. | | | | 5) MECHANICAL PLAN NEEDS TO SHOW THE RETURN AIR GRILLS | | AND SIZE FOR 5 TON AHU SEE YELLOW HIGH LIGHT ON PLAN. | | | | 6) PLEASE SHOW THE LOCATION OF BOTH A/C CONDENSER UNITS | | ON THE MECHANICAL PLANS, AND LABEL THEM. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
F |
Date |
2007-05-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-11 |
Time |
10:43 |
Rev Time |
2.00 |
Received By |
tgordon |
Date |
2007-05-11 |
Time |
10:43 |
Sent To |
P |
|
Notes |
2007-05-11 11:06:31 | | | *** REVISION DENIED *** | | 1) REVISED PLANS ARE SHOWING THE ORIGINAL ADDITION AS | | EXISTING, THIS IS NOT EXISTING AS IT IS STILL PART OF | | THIS PERMIT, PLEASE CORRECT ALL PLANS. | | | | 2) A/C DUCTS HAVE BEEN REMOVED FROM THE ORIGINAL | | ADDITION, PLEASE CORRECT AS THEY ARE STILL PART OF THE | | PERMIT. | | | | 3) SHOW ON MECHANICAL PLANS HOW RETURN AIR IS GETTING | | BACK TO THE AIR HANDLER FROM ALL REQUIRED SPACES. | | | | 4) BATHROOM EXHAUST FANS HAVE BEEN REMOVED FROM | | BATHROOMS, PLEASE CORRECT. | | | | 5) COOLING LOAD CALCULATIONS NEED TO BE RE-CALCULATED | | AS THEY ARE SHOWING THE WRONG AREA AND VOLUME, NEED TO | | BE CALCULATED FOR THE TOTAL ADDITION NOT INCLUDING THE | | ORIGINAL HOUSE. | | | | 6) ENERGY CALCULATIONS NEED TO BE RE-DONE FOR THE SAME | | REASON | | | | 7) SEE MECHANICAL PLANS A/C NOTES: ARE REFERRING TO | | PALM BEACH COUNTY, PLEASE CORRECT TO SHOW CITY OF WEST | | PALM BEACH. | | | | 8) SEE MECHANICAL PLANS TOTAL AREA, PLEASE CORRECT TO | | SHOW AREAS UNDER THIS PERMIT | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-05 |
Time |
09:32 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-09-05 |
Time |
09:32 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-21 |
Time |
08:57 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2006-08-21 |
Time |
08:57 |
Sent To |
B |
|
Notes |
2006-08-21 00:00:00 | *** DENIED *** | | 1) REVISED ENERGY CALCULATIONS WERE NOT | | RE-SUBMITTED. | | | | 2) PROVIED RETURN AIR TO EXISTING DINING | | ROOM. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-16 |
Time |
11:25 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2006-06-16 |
Time |
11:25 |
Sent To |
B |
|
Notes |
2006-06-16 00:00:00 | REVISION TO MECH. PLANS AND E-CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-04-12 |
Time |
15:56 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-04-12 |
Time |
15:56 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-31 |
Time |
12:12 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-01-31 |
Time |
12:12 |
Sent To |
P |
|
Notes |
2006-01-31 00:00:00 | *** DENIED *** | | 1)ENERGY CALCULATIONS NEED TO BE ON FORM | | 600A-04 (2004) PER FBC 13-600.3.A . | | | | 2) NEED MAR MEK INC. OR NELSON MARIN'S | | LICENSE NUMBER ON MECHANICAL PLANS. | | | | 3) NO RETURN AIR IS PROVIDED FOR NEW | | FAMILY ROOM. | | | | 4) NEED TO SHOW SIZE OF THE RETURN AIR | | GRILL IN THE NEW PARLOR BEHIND DOOR. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
P |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-08-15 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-08-15 |
Time |
11:02 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-07-03 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-07-03 |
Time |
15:07 |
Sent To |
B |
|
Notes |
2007-07-03 15:23:49 | DENIED; | | NEW RISER DIAGRAM DOES NOT SHOW THE 2 BATHROOMS ADDED | | TO THE NEW ADDITION. SEE APPROVED PLANS. DO YOU HAVE 2 | | WASHER AND DRYERS, OR WAS THE OLD ONE DELETED? | | APPROVED PLANS SHOW A 3RD BATHROOM WAS THAT BATHROOM | | DELETED? IF SO PLEASENOTE ON PLANS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-05-23 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-05-23 |
Time |
07:25 |
Sent To |
B |
|
Notes |
2007-05-23 07:33:42 | DENIED; | | 1. THE APPROVED PLANS SHOWS NEW BATHROOMS ETC. REVISION | | SHOWS BATHROOMS AS EXISTING. SHOW SANITARY RISER | | DIAGRAM AS APPROVED WITH CHANGES CLOUDED. | | 2. THE OUTSIDE SHOWER CAN NOT GO TO SANITARY. THE WATER | | FROM THIS SHOWER SHOULD GO TO A GRASSY AREA OR TO A | | FRENCH DRAIN. IF DRAIN GO TO FRENCH DRAIN PLEASE SHOW | | DETAIL. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2006-08-19 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-08-19 |
Time |
06:23 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-08-19 |
Time |
06:22 |
Sent To |
M |
|
Notes |
2006-08-19 00:00:00 | REVISION |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-06-15 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-06-15 |
Time |
12:42 |
Sent To |
M |
|
Notes |
2006-06-15 00:00:00 | DENIED; | | PERSON RESPONSIBLE FOR DRAWINGS MUST | | PRINT AND SIGN THEIRNAME TO SAME. | | 106.3.4.3. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-04-13 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-04-13 |
Time |
08:30 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-02 |
Time |
07:46 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2006-02-02 |
Time |
07:46 |
Sent To |
B |
|
Notes |
2006-02-02 00:00:00 | DELETE; | | 1.W/M MUST DISCHARGE DOWN STREAM OF THE | | 1/2 BATH FBC-2004 PLUMBING SEC. 909.1. | | 2.CHANGE NOTE 1 TO FBC-2004 CODE. | | 3.MASTER BATHROOM TUB AND SHOWER ARE NOT | | VENTED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2007-06-25 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-06-25 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-06-25 |
Time |
12:45 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-05-08 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-05-08 |
Time |
17:34 |
Sent To |
I |
|
Notes |
2007-05-08 17:35:56 | ***FAILED*** | | | | | | 1)PLEASE PROVIDE ELEVATION FROM GRADE TO MIDPOINT OF | | ROOF'S PITCH. | | | | 2)DRIVEWAY MUST HAVE SEPERATE PERMIT | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2006-06-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-10 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-10 |
Time |
10:09 |
Sent To |
I |
|
Notes |
2006-06-10 00:00:00 | NEW PLANS: | | NOTE: THE PROPOSED ADDITION (NEW WET | | BAR) MUST NOT BE USED AS A SEPERATE | | KITCHEN (ONLY ONE COOKING FACILITY | | ALLOWED) | | | | SEC 94-303 MECHANICAL/POOL | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | THAN FOUR FEET INTO A SETBACK. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-03 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-03 |
Time |
15:00 |
Sent To |
I |
|
Notes |
2006-04-03 00:00:00 | NOTE: THE PROPOSED ADDITON SITS BEYOND | | THE 25FT FRONT SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-23 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-23 |
Time |
14:22 |
Sent To |
B |
|
Notes |
2006-01-26 00:00:00 | DENIED, | | 1. CANNOT HAVE TWO FRONT DOOR ENTRANCES. | | 2. NEED TO PROVIDE THE SETBACK (SIDE0 | | FOR THE PROPOSED ADDITION. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|