Plan Review Details - Permit 06010290
Plan Review Stops For Permit 06010290
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-10-06 Cont ID  
Sent By amorse Date 2006-10-06 Time 13:27 Rev Time 0.00
Received By amorse Date 2006-10-06 Time 13:27 Sent To PC
Notes
2006-10-06 00:00:00 
  
 REVISION
  
 EXTENSION OF HC RAMP

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-09-01 Cont ID  
Sent By amorse Date 2006-09-01 Time 07:37 Rev Time 0.00
Received By amorse Date 2006-09-01 Time 07:37 Sent To  
Notes
2006-09-01 00:00:00 
  
 PASSED
  
 CONTRACTOR SUBMITTED REQUIRED
 INFORMATION FOR REVISION
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-08-21 Cont ID  
Sent By amorse Date 2006-08-21 Time 08:06 Rev Time 0.00
Received By amorse Date 2006-08-21 Time 08:06 Sent To PC
Notes
2006-08-21 00:00:00 
  
 DENIED
  
 1) PROVIDE ATTACHMENT METHOD FOR METAL
 DECKING TO THE 1/4 X 4X4 ANGLE AND W8X15
 BEAMS
  
 2) PROVIDE INFORMATION ON MATERIAL TO BE
 APPLIED TO THE METAL DECK (CONCRETE,
 LIGHT WEIGHT CONCRETE, ETC.)
  
 3) ROOFING PERMIT MAY ALSO REQUIRE A
 REVISION AS THE ATTACHMENT METHOD AND
 SUBSTRATE WILL BE DIFFERENT THAN WHAT
 WAS APPLIED FOR.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-06-19 Cont ID  
Sent By amorse Date 2006-06-19 Time 12:26 Rev Time 0.00
Received By amorse Date 2006-06-19 Time 12:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-05 Cont ID  
Sent By amorse Date 2006-05-05 Time 08:33 Rev Time 0.00
Received By amorse Date 2006-05-05 Time 08:33 Sent To  
Notes
2006-05-05 00:00:00 
  
 DENIED
  
 NOTES 1 AND 4 WHERE ADDRESSED BUT MORE
 INFORMATION IS NEED, NOTE 3 WAS NOT
 ADDRESSED.
  
 1) HANDRAIL EXTENTION IS SHOWN ON A2-1.0
 BUT SIZE IS NOT SHOWN. PLEASE SHOW THAT
 MIN REQUIREMENT IS MET PER 11-4.8.5(2)
 FBC
 A2-1.0 SHOWS FOOTING UNDER CMU.THERE ARE
 NO DETAILS FOR FOOTING ONTHIS DETAIL OR
 03/A0-0
 LANDINGS ON RAMPS ARE REQUIRED TO BE NO
 LESS THAN 72" PER 11-4.8.4(2) FBC
  
 3) PLEASE SEE A1-1.0 AT DOOR 114 AND
 RAMP MANUVERING REQUIRES A MINIMUM 24"
 OF LEVEL AREA ON THE LATCH SIDE ALSO
 APPROCH FROM THE PUSH SIDE REQUIRES A
 MINIMUM 12" AT THE LATCH SIDE OF DOOR
 (SEE FIG. 25 (A)AND(B) IN CHAPTER 11)
 FBC
  
 4) IN BUILDINGS WITH MULTIPLE ACCESSIBLE
 ENTRANCES, ACCESSIBLE PARKING SPACES
 SHALL BE DISPERSED AND LOCATED CLOSEST
 TO THE ACCESSABLE ENTRANCES PER 11-4.6.2
 FBC
  
 NEW NOTES:
  
 1) DOOR 114 IS AN INTERIOR DOOR THAT
 WILL BE USED AS AN EXTERIOR DOORAS
 SUCH PLEASE PROVIDE PRODUCT APPROVALS
 PER 9B-72 F.A.C. ALSO STATE WIND DESIGN
 CRITERIA AND COMPONENT AND CLADING PSF"S
 FOR DOOR ON DRAWING PER 1603.1.4 FBC
  
 2) APPLICABLE CODES SECTION OF PAGE T1
 AND LS0-0 DO NOT MATCH SHOULD READ FBC
 2004 PLEASE CLARIFY
  
 3) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED. ALTHOUGH IT IS
 GOOD FOR 1 YEAR FROM DATE OF ISSUE WORK
 MUST COMMENCE WITHIN 90 DAYS. PLEASE
 RE-RECORD
  
 4) PLEASE NOTE THAT NO FURTHER PLAN
 REVIEWS WILL BE DONE UNTIL FALSE ALARM
 FEES ARE PAID AND FINANCE DEPT HOLD IS
 REMOVED CONTACT EFRAIM GARCED @ 805-1320
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-03 Cont ID  
Sent By amorse Date 2006-04-03 Time 11:43 Rev Time 0.00
Received By amorse Date 2006-04-03 Time 11:43 Sent To PC
Notes
2006-04-03 00:00:00 
  
 DENIED
  
 1) PROVIDE DETAILS ON RAMP CONSTRUCTION
 FOOTING DETAILS, DECK CONSTRUCTION, TIE
 DOWNS, HANDRAIL ETC.
  
 2) RAMPS SHALL HAVE HANDRAIL ON BOTH
 SIDE PER 11-4.8.5 FBC
  
 3) COMPLY WITH MANUVERING DISTANCE
 REQUIREMENTS AT RAMP LANDING PER
 11-4.13.6 FBC
  
 4) SHOW LOCATION OF ACCESSABLE PARKING
 SPACE AND ROUTE TO NEW ACCESSABLE RAMP
 AND ENTRANCE
  
 5) DOOR HARDWARE SHALL COMPLY WITH
 11-4.13.9
  
 6) DOOR SCHEDULE SHOWS #104 AND #114 AS
 PAIRS PLEASE CLARIFY
  
 7) PROVIDE DETAILS OF RECEPTION COUNTER
 FOR COMPLIANCE WITH ACCESSABILITY PER
 11-7.2
  
 8) PROVIDE ACCESSABILITY REQUIREMENTS
 FOR KITCHEN SINK PER 11-4.24
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-06-26 Cont ID  
Sent By jleahy Date 2007-06-26 Time 17:29 Rev Time 1.00
Received By jleahy Date 2007-06-26 Time 17:29 Sent To  
Notes
2007-06-26 17:30:29AS BUILTFOR JOBJL

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-05-29 Cont ID  
Sent By jleahy Date 2007-05-29 Time 20:29 Rev Time 1.30
Received By jleahy Date 2007-05-29 Time 20:28 Sent To  
Notes
2007-05-29 20:30:13NOTE TO INSPECTOR
  
 PLAN STATES NO NEW CIRCUITS, IF NEW ONES ARE ADDED THEN
 NEW PANEL
 SCHEDULES WILL BE REQUIRED.
  
 JAKE

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-11-20 Cont ID  
Sent By dpalmer Date 2006-11-20 Time 18:45 Rev Time 0.00
Received By dpalmer Date 2006-11-20 Time 18:28 Sent To PC
Notes
2006-11-20 18:46:12*** UNSAT ***
  
  
 1) NOTE: PLEASE KNOW THAT THE ENGINEER SHOWN ON PLANS
 SUBMITTED FOR REVISIONS TO ELECTRICAL LIGHTING PLANS IS
 NOT THE ENGINEER OR FIRM OF RECORD.
 PLEASE KNOW THIS IS NOT PERMITTED UNDER FLORIDA
 STATUTES 471.025.
 MUST BE THE ENGINEER/ FIRM OF RECORD OR PLANS CAN BE
 TAKEN OVER BY ANOTHER ENGINEERING HOWEVER PLEASE CALL
 TO GO OVER ANY SUCH REQUIREMENTS FOR THIS.
  
 ** PLEASE KNOW AS FYI, THE TITLE BLOCK FOR ENGINEERING
 FIRM AS SHOWNIS MISSING LICENSE NUMBER FOR FIRM AS
 REQUIRED UNDER FLORIDA ADMINISTRATIVE CODE
 61G15-23.002, AND FLORIDA STATUTES 471.023. THIS IS FOR
 INFORMATIONAL PURPOSE ONLY.
  
  
 IF THERE ARE ANY QUESTIONS ON THE ABOVE COMMENTS, OR IF
 THE COMMENTS ARE NOT CLEAR IN ANY FASHION, PLEASE DO
 NOT HESITATE IN CONTACTING THIS REVIEW WITH QUESTIONS
 OR COMMENTS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPARTMENT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-09-20 Cont ID  
Sent By dpalmer Date 2006-09-20 Time 12:49 Rev Time 0.00
Received By dpalmer Date 2006-09-20 Time 12:49 Sent To PC
Notes
2006-09-20 00:00:00REVISION FOR CHANGING CONDUIT TO ALSO
 ALLOW MC CABLE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-17 Cont ID  
Sent By dpalmer Date 2006-09-17 Time 10:57 Rev Time 0.00
Received By dpalmer Date 2006-09-17 Time 10:57 Sent To PC
Notes
2006-09-17 00:00:00ELEC REV/AS-BUILTS OK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-03 Cont ID  
Sent By dpalmer Date 2006-05-03 Time 20:08 Rev Time 0.00
Received By dpalmer Date 2006-05-03 Time 19:23 Sent To  
Notes
2006-05-03 00:00:00OLD VOIDED ELECTRICAL SHEETS REMOVED,
 ELECTRICAL PLANS STAMPED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-10 Cont ID  
Sent By dpalmer Date 2006-02-10 Time 21:15 Rev Time 0.00
Received By dpalmer Date 2006-02-10 Time 20:59 Sent To  
Notes
2006-02-10 00:00:00IN ELEC FOR REVIEW
 ******** UNSAT **********
  
 1)NOTE: PLEASE INDICATE ALL CIRCUITING
 ON PLANS AND CORRELATE A PANEL SCHEDULE
 OR PANEL SCHEDULE(S) TO BE SUBMITTED.
 NEW OR EXISTING PANELS BEING ADDED FOR
 WORK/ CIRCUITS?
 215.5
  
 2)NOTE: PLEASE SEE MANY NEW 30A RECEPTS
 ARE INDICATED. PLEASE ALSO SEE PLANS
 INDICATE 60A RECEPTS ALSO WITH OUT ANY
 INFORMATIONFOR LOADS DEVICES ETC.
 PLEASE SUBMIT LOAD CALCUALTIONS FOR ALL
 EXISITNG AND NEW TO BE ADDED. PLEASE
 ALSO SPECIFY USE OF THE NEW DEVICES AND
 LOADS.
 215.5,220
  
 3)NOTE: PLEASE SEE SHEET T-1 WHICH
 INDICATES A 2004 NFPA-101. PLEASE KNOW,
 AS OF JAN 1ST, 2005 WE ARE CURRENTLY
 UNDER THE 2003 NFPA-101.
  
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2006-06-21 Cont ID  
Sent By mwennerg Date 2006-06-21 Time 09:07 Rev Time 0.00
Received By mwennerg Date 2006-06-21 Time 09:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-05-05 Cont ID  
Sent By mwennerg Date 2006-05-05 Time 15:02 Rev Time 0.00
Received By mwennerg Date 2006-05-05 Time 15:02 Sent To  
Notes
2006-05-05 00:00:00******DENIED******
  
 1) RESPONSE TO COMMENT 1- PLEASE NOTE
 THAT NFPA 101, 2003 EDITION SHALL BE
 REFERENCED. 2004 EDITION SHALL BE
 APPLIED TO THE FLORIDA FIRE PREVENTION
 CODE.
  
 2) PLEASE PROVIDE INFORMATION REGARDING
 STORAGE AND APPLICATION OF MATERIALS
 USED IN JEWELRY PROCESS. PLEASE INDICATE
 QUANTITY AND TYPE OF MATERIAL.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-02-15 Cont ID  
Sent By mwennerg Date 2006-02-15 Time 14:24 Rev Time 0.00
Received By mwennerg Date 2006-02-15 Time 14:24 Sent To  
Notes
2006-02-15 00:00:00******DENIED******
  
 1) NFPA 101, AND NFPA-1 2003 EDITION
 SHALL BE REFERENCED. PLEASE MAKE
 CORRECTION ON SHT T-1.
  
 2) RAMPS AND STAIRS SHALL HAVE HANDRAILS
 ON BOTH SIDES.
  
 3) MONTGOMERY HALL OCCUPANT LOAD IS
 INCORRECT. CALCULATION WAS BASED ON 5
 SQ'/PERSON, HOWEVER 15 SQ'/PERSON SHOULD
 BE USED.
  
 4) PLEASE INDICATE THE INTERIOR FINISH
 CLASSIFICATION OF WALLS AND CEILINGS,
 CLASS A,B,OR C.
  
 5) SEPARATE SHOP DRAWING AND PERMITS
 REQUIRED FOR FIRE SPRINKLER AND FIRE
 ALARM REMODEL.
  
 6) EXIT DOORS SERVING OCCUPANT LOADS
 GREATER THAN 100 SHALL HAVE PANIC
 HARDWARE. PLEASE SHOW ON DOOR SCHEDULE.
  
  
 7) A CURRENT OCCUPANT LOAD SIGN MAY BE
 OBTAINED FROM THE BUREAU OF FIRE
 PREVENTION IF DIFFERENT FROM LAST
 CACULATION.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLANS REVIEW (%^1) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2006-06-15 Cont ID  
Sent By pschmitz Date 2006-06-15 Time 14:13 Rev Time 0.00
Received By pschmitz Date 2006-06-15 Time 14:36 Sent To  
Notes
2006-06-15 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 PROVISO:
  
 SEE LETTER DATED 6-2-06 FROM HERRICK
 BROS. CONST. JEFF WADE.
 ARMORY ARTS CNTR STAFF IS STILL IN
 DEVELPOPING STAGES FOR STUDIOS 110, 111.
 REVISIONS TO FOLLOW WHEN DESIGN IS
 COMPLETED.
  
 QUESTIONS 561-805-6692
  
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-05-02 Cont ID  
Sent By pschmitz Date 2006-05-02 Time 15:09 Rev Time 0.00
Received By pschmitz Date 2006-05-02 Time 15:19 Sent To  
Notes
2006-05-02 00:00:00PLAN REVIEW DATED 5-2-06 FOR GAS
  
 RESPONSE DATED 3-28-06 BY NELSON LONG
 GAS IS NOT IN THE SCOPE OF RENOVATION

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-03-11 Cont ID  
Sent By pschmitz Date 2006-03-11 Time 11:11 Rev Time 0.00
Received By pschmitz Date 2006-03-11 Time 11:11 Sent To  
Notes
2006-03-11 00:00:00PAUL SCHMITZ
 FBC 2004 FUEL GAS CODE, PLAN REVIEW
 DENIED
  
 1)SHT A1-1.0 SEC 415 GROUP H-5
 OCCUPANCY. ROOM #110,111 JEWELRY MFG.
 STUDIO. PROVIDE IN DETAIL ALL
 INFORMATION REQUIRED FOR GROUP H-5 USE.
  
 2) SEC 106.3.5.2 GAS: ISOMETRIC
 REQUIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop HIST HISTORICAL
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2006-01-09 00:00:00OK PER F MITNER 1-8-06

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-06-26 Cont ID  
Sent By adarroug Date 2007-06-26 Time 15:07 Rev Time 0.00
Received By adarroug Date 2007-06-26 Time 15:07 Sent To E
Notes
2007-06-26 15:07:47TO 'JLEAHY" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 16:13 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 16:13 Sent To E
Notes
2007-05-29 16:15:09TO "E" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-11-20 Cont ID  
Sent By adarroug Date 2006-11-20 Time 11:04 Rev Time 0.00
Received By adarroug Date 2006-11-20 Time 11:04 Sent To E
Notes
2006-11-20 11:05:15TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2006-10-03 Time 17:13 Sent To  
Notes
2006-10-03 00:00:00TO "COMM" BD#27

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-09-26 Cont ID  
Sent By adarroug Date 2006-09-26 Time 16:27 Rev Time 0.00
Received By adarroug Date 2006-09-26 Time 16:27 Sent To P
Notes
2006-09-26 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-09-13 Cont ID  
Sent By adarroug Date 2006-09-13 Time 13:16 Rev Time 0.00
Received By adarroug Date 2006-09-13 Time 13:16 Sent To E
Notes
2006-09-13 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-17 Cont ID  
Sent By adarroug Date 2006-08-17 Time 17:57 Rev Time 0.00
Received By adarroug Date 2006-08-17 Time 17:57 Sent To Z
Notes
2006-08-17 00:00:00TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-07 Cont ID  
Sent By adarroug Date 2006-06-07 Time 16:15 Rev Time 0.00
Received By adarroug Date 2006-06-07 Time 16:15 Sent To  
Notes
2006-06-07 00:00:00TO "BOB"#14--EXPEDITED PLANS--

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-01 Cont ID  
Sent By adarroug Date 2006-05-01 Time 16:46 Rev Time 0.00
Received By adarroug Date 2006-05-01 Time 16:46 Sent To  
Notes
2006-05-03 00:00:00TO "BOB"#15
2006-05-01 00:00:00WAITING FOR "BOB"
 EXPEDITED PLANS--PER RBROWN

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-03 Time   Rev Time 0.00
Received By adarroug Date 2006-01-10 Time 16:21 Sent To  
Notes
2006-03-24 00:00:00MOVED TO BOB #3
  
2006-02-01 00:00:00TO "COMM" BD#13
2006-01-10 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-02-23 Cont ID  
Sent By hmoser Date 2006-02-23 Time 17:21 Rev Time 0.00
Received By hmoser Date 2006-02-23 Time 17:21 Sent To  
Notes
2006-02-23 00:00:00NO MECHANICAL PLANS.2/23/06 HM.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-10-18 Cont ID  
Sent By jleech Date 2006-10-18 Time 07:55 Rev Time 0.00
Received By jleech Date 2006-10-18 Time 07:55 Sent To  
Notes
2006-10-18 07:55:50AS BUILTS

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-06-16 Cont ID  
Sent By pschmitz Date 2006-06-15 Time 14:37 Rev Time 0.00
Received By pschmitz Date 2006-06-15 Time 14:37 Sent To  
Notes
2006-06-16 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 PROVISO:
  
 SEE LETTER DATED 6-2-06 FROM HERRICK
 BROS. CONST. JEFF WADE.
 ARMORY ARTS CNTR STAFF IS STILL IN
 DEVELPOPING STAGES FOR STUDIOS 110, 111.
 REVISIONS TO FOLLOW WHEN DESIGN IS
 COMPLETED.
  
 SEE RESPONSE DATED 6-16-06 FROM LYNN
 MASSON.
 EXEMPTION GRANTED DUE TO SMALL AMOUNT OF
 WASTE WATER DISCHARGE, FOR CHEMICALS IN
 PRINT MAKING STUDIO 108, DARK ROOM 109.
  
 QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-05-03 Cont ID  
Sent By pschmitz Date 2006-05-03 Time 10:54 Rev Time 0.00
Received By pschmitz Date 2006-05-02 Time 15:21 Sent To  
Notes
2006-05-02 00:00:00 
 PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
 UNSAT
 PREVIOUS COMMENTS DATED 3-11-06 NOTE #3
 SHT A1-1.0 RM 109 IS LABELED AS A DARK
 ROOM WITH A SOLUTION BENCH.
  
 3) SHT A1-1.0 ROOM ,109 DARK ROOM.
 SEC 803.2 NEUTRALIZING DEVICE REQUIRED
 FOR CORROSIVE WASTE.
 CONTACT W P BEACHWATERPLANT LAB
 SUPERVISORINDUSTRIAL COORDINATOR,
 LYNN MASSON
 OFFICE 561-822-2271
 E-MAIL [email protected]
  
 NOTE #4 NOT ADDRESSED.
 4)SHT A1-1.0 SEC 415 GROUP H-5
 OCCUPANCY. ROOM #110,111 JEWELRY MFG.
 STUDIO. PROVIDE IN DETAIL ALL
 INFORMATION REQUIRED FOR GROUP H-5 USE.
  
 5-2-06 REVISIONS COMMENT UNSAT WAITING
 FOR A CALL FROM ARCHITE5CT
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-11 Cont ID  
Sent By pschmitz Date 2006-03-11 Time 09:57 Rev Time 0.00
Received By pschmitz Date 2006-03-11 Time 09:57 Sent To  
Notes
2006-03-11 00:00:00 
 PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 DENIED
  
 1) 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. ELECTRONIC MEDIA DOUCMENTS ARE
 PERMITTED TO BE SUBMITTED WHEN APPROVED
 BY THE BUILDING OFFICAL. CONSTRUCTION
 DOUCMENTS SHALL BE OF SUFFICENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT ITWILL CONFORM TOTHE
 PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS
 AS DETERMINED BY THE BUILDING OFFICAL (
 SEE ALSO SECTION 106.3.5)
 2) SHT LS0-0 REQUIRED MINIMUM FACILITIES
 SHOW THE LOCATION OF THE REQUIRED D/F
 AND S/S, REFERENCED ON CODE SUMMARY.
 3) SHT A1-1.0 ROOM #108,109 DARK ROOM.
 SEC 803.2 NEUTRALIZING DEVICE REQUIRED
 FOR CORROSIVE WASTE.
 CONTACT W P BEACHWATERPLANT LAB
 SUPERVISORINDUSTRIAL COORDINATOR,
 LYNN MASSON
 OFFICE 561-822-2271
 E-MAIL [email protected]
 4)SHT A1-1.0 SEC 415 GROUP H-5
 OCCUPANCY. ROOM #110,111 JEWELRY MFG.
 STUDIO. PROVIDE IN DETAIL ALL
 INFORMATION REQUIRED FOR GROUP H-5 USE.
 5) SHT A1-1.0 CONFERENCE RM SINK.
 11-4.24 SINKS.
 11-4.24.1 GENERAL.
 SINKS REQUIRED TO BE ACCESSIBLE BY
 SECTION 11-4.1 SHALL COMPLY WITH SECTION
 11-4.24.
 11-4.24.2 HEIGHT.
 SINKS SHALL BE MOUNTED WITH THE COUNTER
 OR RIM NO HIGHER THAN 34 INCHES (865 MM)
 ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE.
 KNEE CLEARANCE THAT IS AT LEAST 27
 INCHES (685 MM) HIGH, 30 INCHES (760 MM)
 WIDE, AND 19 INCHES (485 MM) DEEP SHALL
 BE PROVIDED UNDERNEATH SINKS.
 11-4.24.4 DEPTH.
 EACH SINK SHALL BE A MAXIMUM OF 6?
 INCHES (165 MM) DEEP.
 11-4.24.5 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE AT LEAST 30 INCHES
 BY 48 INCHES (760 MM BY 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE
 PROVIDED IN FRONT OF A SINK TO ALLOW
 FORWARD APPROACH. THE CLEAR FLOOR SPACE
 SHALL BE ON AN ACCESSIBLE ROUTE AND
 SHALL EXTEND A MAXIMUM OF 19 INCHES (485
 MM) UNDERNEATH THE SINK (SEE FIGURE
 11-32).
 11-4.24.6 EXPOSED PIPES AND SURFACES.
 HOT WATER AND DRAIN PIPES EXPOSED UNDER
 SINKS SHALL BE INSULATED OR OTHERWISE
 CONFIGURED SO AS TO PROTECT AGAINST
 CONTACT. THERE SHALL BE NO SHARP OR
 ABRASIVE SURFACES UNDER SINKS.
 11-4.24.7 FAUCETS.
 FAUCETS SHALL COMPLY WITH SECTION
 11-4.27.4. LEVER-OPERATED, PUSH-TYPE,
 TOUCH-TYPE, OR ELECTRONICALLY CONTROLLED
 MECHANISMS ARE ACCEPTABLE DESIGNS.
 6)SEC 106.3.5.1.3 (3,4.)COMMERICAL
 BUILDINGS: PLUMBING, SANITARY; WATER.
 ISOMETRIC REQUIRED.
 7) SEC 106.3.5.2 GAS: ISOMETRIC
 REQUIRED.
 8)PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
 END OF COMMENTS, QUESTIONS 561-805-6692
  
  