Plan Review Details - Permit 06010171
Plan Review Stops For Permit 06010171
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-06-01 Cont ID  
Sent By lmartine Date 2007-06-01 Time 14:23 Rev Time 0.00
Received By lmartine Date 2007-06-01 Time 14:22 Sent To  
Notes
2007-06-01 17:00:58REVISION AT SLIDING GLASS DOOR,OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-04-06 Cont ID  
Sent By lmartine Date 2007-04-06 Time 12:55 Rev Time 0.00
Received By lmartine Date 2007-04-06 Time 12:55 Sent To  
Notes
2007-04-06 12:56:052/27/07 REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-08-16 Cont ID  
Sent By alange Date 2006-08-16 Time 09:56 Rev Time 2.00
Received By alange Date 2006-08-16 Time 09:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-07-25 Cont ID  
Sent By alange Date 2006-07-25 Time 10:48 Rev Time 1.25
Received By alange Date 2006-07-25 Time 10:42 Sent To E
Notes
2006-07-25 00:00:00DENIED
 FIFTH REVIEW:
  
 1. 713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 5.SUBMIT SPECIFICATIONS FOR REQUIRED
 BBQ HOOD OR REMOVE BBQ FROM PLANS.
 CHANGES TO PLANS SHALL BE DONE BY THE
 DESIGNER OF RECORD.
  
 A.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED TRUSS SETS ONE SET IS A PHOTO
 COPY AND SIGNATURES ARE NOT ORIGINAL
 THEY ARE STAMPS.
 NOTE:TRUSS DRAWINGS ARE NOT REQUIRED
 FOR PERMITTING, BUT ARE REQUIRED TO BE
 APPROVED PRIOR TO INSTALLATION.
 R-802.10.1
  
 SEE ATTACHED NOTICE REGARDING REPEATED
 PLAN REVIEWS.FS 553.80(2)(B)
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE SET OF
 OLD PAGES. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-07-10 Cont ID  
Sent By alange Date 2006-07-10 Time 13:36 Rev Time 1.25
Received By alange Date 2006-07-10 Time 13:31 Sent To  
Notes
2006-07-10 00:00:00DENIED
 FOURTH REVIEW:
  
 1. 713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5.SUBMIT SPECIFICATIONS FOR REQUIRED
 BBQ HOOD.
  
 6.SIGN OWNER/ AGENT ON ENERGY CALCS
 FBC 2004 13-600.3ABC.2.
  
 NEW COMMENT:
 A.TRUSS DRAWINGS, ENGINEER JOHN
 WEBER'S SEALS ARE EXPIRED AND SHOULD
 READ "LICENSED" NOT CERTIFICATE. FS
 472.025
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE SET OF
 OLD PAGES. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-16 Cont ID  
Sent By alange Date 2006-06-16 Time 12:55 Rev Time 1.50
Received By alange Date 2006-06-16 Time 11:30 Sent To  
Notes
2006-06-16 00:00:00DENIED
 THIRD REVIEW:
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5.SUBMIT SPECIFICATIONS FOR BBQ HOOD.
  
 6.SIGN OWNER/ AGENT ON ENERGY CALCS
 FBC 2004 13-600.3ABC.2.
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE SET OF
 OLD PAGES. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-04-12 Cont ID  
Sent By alange Date 2006-04-12 Time 15:40 Rev Time 2.00
Received By alange Date 2006-04-12 Time 15:18 Sent To  
Notes
2006-04-12 00:00:00DENIED
 SECOND REVIEW:
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS PER9B-72.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4. W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 5.SUBMIT SPECIFICATIONS FOR BBQ GRILL,
 HOOD AND FIREPLACE.
  
 6.SUBMIT TWO COPIES OF ENERGY CALCS.
  
 NEW COMMENT:
 9.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-03 Cont ID  
Sent By alange Date 2006-02-03 Time 07:24 Rev Time 3.25
Received By alange Date 2006-02-03 Time 07:24 Sent To  
Notes
2006-02-03 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2. BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS PER9B-72.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4. W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 5.SUBMIT SPECIFICATIONS FOR BBQ GRILL,
 HOOD AND FIREPLACE.
  
 6.SUBMIT TWO COPIES OF ENERGY CALCS.
  
 7.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 8.SUBMIT A DETAIL FOR GUARD RAILS
 COMPLYING WITH R-312.1 ANF R-312.2
  
 9.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.R-807
  
 10.SAFTEY GLAZING IS REQUIRED AT TUB
 LOCATIONS R-308.4
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 11 Status P Date 2008-01-30 Cont ID  
Sent By btrobaug Date 2008-01-30 Time 10:58 Rev Time 0.00
Received By btrobaug Date 2008-01-30 Time 07:00 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 10 Status P Date 2007-11-14 Cont ID  
Sent By btrobaug Date 2007-11-14 Time 07:48 Rev Time 0.00
Received By btrobaug Date 2007-11-14 Time 07:16 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 9 Status F Date 2007-09-13 Cont ID  
Sent By btrobaug Date 2007-09-13 Time 14:00 Rev Time 0.00
Received By btrobaug Date 2007-09-13 Time 13:03 Sent To PC
Notes
2007-09-13 14:00:15 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC AS AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
  
 1} 210.52(B)(1) SMALL APPLIANCES
 RECEPTACLE OUTLETS SERVED IN THE KITCHEN, PANTRY,
 BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA OF A
 DWELLING UNIT, THE TWO OR MORE 20-AMPERE
 SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
 210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
 OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP OUTLETS
 COVERED BY 210.52(C), AND RECEPTACLE OUTLETS FOR
 REFRIGERATION EQUIPMENT.
 210.52(B)(2) NO OTHER OUTLETS THE TWO OR MORE
 SMALL-APPLIANCE BRANCH CIRCUITS SPECIFIED IN
 210.52(B)(1) SHALL HAVE NO OTHER OUTLETS. SEE PANEL
 SCHEDULE A CIRCUITS 18 AND 19 ARE IN VIOLATION OF THESE
 ARTICLES. THE DEVICES WERE NOT CIRCUITED ON PREVIOUS
 PLANS. THE LIGHTS MAY NOT BE ON THOSE CIRCUITS EITHER.
  
 2} 210.11(C)(3) BATHROOM BRANCH CIRCUITS IN ADDITION TO
 THE NUMBER OF BRANCH CIRCUITS REQUIRED BY OTHER PARTS
 OF THIS SECTION, AT LEAST ONE 20-AMPERE BRANCH CIRCUIT
 SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
 CIRCUIT A-21. THE MEDIA AND POWDER ROOM BATHS AREN?T
 MARKED, BUT DON?T APPEAR ON SEPARATE CIRCUITS IN THE
 SCHEDULES. ?HIS? BATH ON THE SECOND FLOOR IS ALSO IN
 VIOLATION AS IT SHARES LIGHTS AND RECEPTACLES IN THE
 COMMON HALL.
  
 3} 110.26 THE POOL PUMP AND ACU #1 DISCONNECTS DO NOT
 SEEM TO HAVE THE REQUIRED CLEARANCES.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH [email protected]
 ELECTRICAL PLANS EXAMINER 561/805-6718
 CITY OF WEST PALM BEACH

Review Stop E ELECTRICAL
Rev No 8 Status F Date 2007-08-14 Cont ID  
Sent By btrobaug Date 2007-08-14 Time 08:08 Rev Time 0.00
Received By btrobaug Date 2007-08-13 Time 16:13 Sent To PC
Notes
2007-08-14 08:31:22 
 REVISION DENIED
  
 ALL REVISIONS MUST BE DRAWN AND SIGNEDBY THE DESIGNER
 OF RECORD, MICHAEL GARRISON. 106.1 FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-08-11 Cont ID  
Sent By dpalmer Date 2006-08-11 Time 19:06 Rev Time 0.00
Received By dpalmer Date 2006-08-11 Time 19:06 Sent To M
Notes
2006-08-11 00:00:00*** REDLINED THE FOLLOWING**
  
  
 PLEASE SEE MISSING EGRESS LT FIXTURE
 REQUIRED IN FOYER AREA FOR EGRESS FROM
 SEC FLR TO FIRST FLR AND 1ST FLR TO 2ND
 FLR. SOME SORT OF LT FIXTURE WILL BE
 REQUIRED. 210.70, LS 101 7.8
  
 PLEASE SE LOAD CALCULATIONS SHOW
 2-GARAGE DOOR OPENER CIRCUITS, HOWEVER
 PANEL SCHEDULE MENTIONS "'S" TWO YET
 ONLY IN ONE SPACE.
  
 THE ABOVE MAY BE REVISED WHEN PLANS ARE
 REVISED FOR ANY OTHER ITEMS BEFORE
 ROUGH.
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2006-07-25 Cont ID  
Sent By dpalmer Date 2006-07-25 Time 20:05 Rev Time 0.00
Received By dpalmer Date 2006-07-25 Time 17:39 Sent To PC
Notes
2006-07-25 00:00:00*********** UNSAT 5TH REVIEW *********
  
 ** PLEAS SEE THIS IS THE 5TH REVIEW.
 PLEASE SEE SOME COMMENTS BELOW ARE STILL
 IN NEED OF BEING ADDRESSED FROM PREVIOUS
 REVIEWS AND PLEASE SEE SOME NEW
 COMMENTS.
  
  
 1) NOTE: PLEASE SEE SERVICE RISER IS
 STILL VERY UNCLEAR AS THE 100A MCB SUB
 PANEL IS NOT FED FROM ANYWHERE? PLEASE
 SEE RISER SHOWS THIS PANEL BEING FED
 FROM PANEL "A", HOWEVER PANEL "A" DOES
 NOT LIST THIS PANEL, OCP ETC ON ITS
 PANEL SCHEDULE. WHERE IS THIS PANEL FED
 FROM?
 FBC 106.1.2 ADMIN SECT., 215.5 ,
 240.4,310.16 ETC.
  
 2) NOTE: PLEASE CORRELATE AIC RATINGS AS
 RISER SHOWS 22K FOR THE MCB AND PANEL
 "A" SHOWS 10K? IF THE MAINS ARE 22K AND
 THE BRANCH BREAKERS ARE SIZED AT SERIES
 RATINGS, THEN PLEASE INDICATE THE 10K
 FOR BRANCH BRKRS ONLY. IF IT SOMETHING
 DIFFERENT, THEN PLEASE ADJUST.
 110.9, 106.1.2FBC
  
 3) NOTE: PLEASE SEE RISER IS SHOWING
 "EQUIPMENT GROUNDING CONDUCTORS " FROM
 METER TO MAIN. PLEASE SEE 250.6,
 250.24B, AS THE EGC IS ONLY INSTALLED
 AFTER THE FIRST MEANS OF DISCONNECT.
  
 4)NOTE: PLEASE SEE RISER SHOWS 100A SUB
 PANEL BEING FED WITH 3-3/0'S?? AND #6
 EQUIPMENT GROUNDING CONDUCTOR?? PLEASE
 KNOW, IT IS OK TO USE THESE OVERSIZED
 CONDUCTORS, HOWEVER RISER SHOWS THEM IN
 A "1/2" CONDUIT?? AND 3/0'S WILL NOT FIT
 INTO THE 100A BRKR. PLEASE VERIFY AND
 SEE 310.16/310.15B6 FOR SIZING. PLEASE
 SEE CHAPTER 9 TABLES FOR CORRECT SIZING
 OF CONDUIT FOR CONDUIT FILL.
 215.5.
  
 5) NOTE: PLEASE INDICATE METER CAN SIZE
 AS PREVIOUS PLANS CALLED FOR 200A
 SERVICE.
 106.1.2
  
 6) NOTE: PLEASE CORRELATE ALL A/C
 MECHANICAL LOADS, OVER CURRENT
 PROTECTION AND WIRE SIZES. PLEASE SEE
 OCP IS NOW MISSING FOR SOME AHU'S HEAT?
 PLEASE SEE 424.3B FOR MIN SIZING. PLEASE
 SEE TWO AHU'S ARE NOW SHOWING 5KW HEAT
 YET, STILL IDNCATE 60A OCP ON LOAD
 CALCULATIONS AND #6 WIRE. ONCE AGAIN,
 PLEASE VERIFY THIS AS 5KW UNITS ARE NOW
 BEING SHOWN AND 60A OCP IS WAY TOO HIGH.
 PLEASE ALSO KNOW, #6 WIRE WILL NOT FIT
 IN THE CORRECT SIZE BRKR THEY NEED TO
 BE.
 PLEASE ALSO SEE CU'S AS THESE ARE ALSO
 SHWOING 60A OCP. UPON REVIWING THE
 MECHANICAL EQUIPMENT SCHEDULE UNITS #2
 AND #3 ARE 2.5 AND 3.0 TON UNITS. PLEASE
 CONSULT YOUR MECHANICAL PERSON AS THE
 OCP IS WAY TOO HIGH. PLEASE ALSO ADJUST
 THE CONDUCTOR SIZE CORRECLTY AS THE #6'S
 WILL ALSO NOT FIT IN THE OCP NEEDED
 ONCE THESE ARE ADJUSTED.
 240, 440, 430, 240.4, 310.16,ETC ETC
 106.1.2 FBC.
  
 7) NOTE: PLEASE SEE LOAD FOR ELEVATOR ON
 PANEL SCHEDULE DOES NOT CORRELATE WITH
 THE LOAD CALCULATIONS.PLEASE SEE A LOAD
 OF 3300 VA IS BEING SHOWN ON BOTH "A"
 AND "B" PHASE WHICH WOULD BE A TOTAL
 LOAD ON LOAD CALCS OF 6600VA. PLEASE
 VERIFY WHAT THE LOADS ACTUALLY ARE.
 IF LOAD IS INDEED 6600, PLEASE ADJUST
 THE OCP AND CONDUCTOR SIZES ALONG WITH
 REVISING THE LOAD CALCULATIONS.
 240.4,310.16,220 ETC.
  
 8) NOTE: PLEASE SEE SMALL APPLIANCE
 CIRCUITS ARE STILL BEING SHOWN AT
 2400VA. PLEASE SEE 210.11C1,220.16 AS SM
 APPL CIRCUITS ARE 1500VA. PLEASE SEE
 THAT 2400VA WAY EXCEEDS THE RATING OF A
 20A CIRCUIT. (1920VA MAX).
  
 9) NOTE: PLEASE SEE LOADS SHOWN FOR
 ELEVATOR CAR LTS AND RECEPTS WHICH SEEM
 TO INDICATE DEDICATED LOAD OF 1080VA YET
 THIS LOAD OS NOT ON LOAD CALCULATIONS?
 PLEASE ALSO SEE AN ADDITIONAL LOAD OF
 1080VA IS SHOWN FOR ELEV CAR YET THIS IS
 ALSO NOT SHOWN IN LOAD CALCULATIONS?
 220.
  
 10 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 11) NOTE: PLEASE LIST ALL CIRCUITING ON
 PANEL SCHEDULE(S) FOR SPECIFIC AREAS AND
 PLEASE LIST ALL THE REQUIRED ARC FAULT
 PROTECTED CIRCUITS AS REQUIRED PER
 210.12B,. 408.4
 IE; MASTERBEDRM LTS, KITCHEN LTS,
 LIVING RM RECEPTS ETC.
 IT IS KNOWN TO THIS OFFICE THAT THE
 BRNACH CIRCUITING WILL MOST LIKELY
 CHANGE SURING CONSTRUCTION , HOWEVER THE
 MIN CIRCUITS SHALL BE ON PANEL SCHEDULES
 AT THIS TIME.
  
 12) NOTE: PLEASE SEE AN ESTIMATE LOAD OF
 900VA IS BEING SHOWN FOR ALL THE GEN LT
 AND RECEPT CIRCUITS. WHERE IS THIS 900VA
 COMING FROM. PLEASE SEE TOTAL GEN LT
 DEMAND IS 15,000+ VA AND DOES NOT
 CORRELATE WITH THIS.
 PLEASE SEE NEC 220,215.5 ETC.
  
 13) NOTE: PLEASE SEE THAT SMOKE
 DETECTORS ARE REQUIRED WITHIN 12" OF THE
 HIGHEST POINT OF ANY FLAT CEILINGS AND
 SLOPED CEILING WITHIN 3' OF PEAK. PLEASE
 SEE THAT IF THE TRAY CEILINGS AS SHOWN
 ARE 12" OR MORE UP FROM OTHER
 SURROUNDING CEILINGS AREAS, THEN THE
 SD'S ARE REQUIRED TO BE MOVED. PLEASE
 SEE SD'S LOCATED WITHIN 20' OF COOKING
 APPLIANCES SHALL MEET THE EXCEPTIONS AS
 BEING PHOTO-ELECTRIC EYE TYPE/RESETTING
 TYPE AS REQUIRED.
 PLEASE SEE NFPA-72 2002 11.8.3 FOR THESE
 INSTALLATION REQUIREMENTS.
  
 14) NOTE: PLEASE SEE 680.71 AS NO GFI
 PROTECTION IS NOTED FOR WHIRLPOOL TUB.
 PLEASE ALSO SEE THAT NO ELECTRICAL FOR
 THIS SAME TUB IS BEING SHOWN ON PLANS??
 PLEASE CORRELATE.
 106.1.2
  
 15) NOTE: PLEASE SEE THAT THE PLANS
 SHALL STATE THE CURRENT CODES IN EFFECT
 FOR THE FOLLOWING. PLEASE LIST THE
 FOLLOWING AT A MINIMUM WHICH ARE
 RELEVANT TO THE ELECTRICAL PLANS.
 2002 NFPA-70( NEC), 2002 NFPA-72, 2003
 NFPA-101.
  
 16) NOTE: PLEASE SEEMISSING EGRESS
 LIGHTING CONTROLS WHEN EXITING TO
 OUTSIDE FROM THE FOLLOWING AREAS. MEDIA
 RM, LIVING RM, NOOK AND FAMILY RM.
 PLEASE KNOW, LIGHTING MAY BE CONTROLLED
 BY MULTIPLE LOCATIONS BY 3-/4-WAYS.(ONLY
 A SUGGESTIONS) MUST HAVE MIN CONTROL FOR
 SOME SORT OF LIGHTING FIXTURE.
 NFPA-70 210.70, NFPA-101 7.8
  
 17) NOTE: PLEASE SEE 210.52B1, 210.11C1,
 220.16 AS DINING SHALL BE ON ONE OR MORE
 OF THE REQUIRED SMALL APPLIANCE
 CIRCUITS. PLEASE LIST AND SEE MIN VA
 (1500VA) REQUIRED.
  
 18) NOTE: PLEASE SEE PANEL SCHEDULE
 SEEMS TO MENTIONS THREE CIRCUITS FOR
 "GFI"?? HOWEVER THIS IS UNCLEAR WHAT
 THESE ARE FOR. PLEASE LIST.
 408.4
  
 19) NOTE: PLEASE SEE MISSING THE
 REQUIRED DEDICATED BATH(S) CIRCUIT(S)
 PER 210.52D,210.11C3. MUST BE #12 AND
 20A. (IS CIRCUITS FROM NOTE #18 THESE??)
 IF SO, PLEASE LABEL.
  
 20) NOTE: PLEASE SEE PLANS SEEM TO
 INDICATE SOME SORT OF "HEATER" FOR
 FUTURE POOL EQUIPMENT?? PLEASE BE SURE
 TO INDICATE IF GAS (FUTURE) OR
 ELECTRIC(FUTURE). PLEASE KNOW HOWEVER,
 IF THIS IS GOING TO BE AN ELECTRICAL
 HEAT PUMP, THEN PLEASE KNOW THE LOAD
 NEEDS TO BE FIGURED INTO THE SERVICE AT
 THIS TIME.
 PLEASE ADJUST OF ELECTRIC HEAT PUMP.
 PLEASE ALSO KNOW, ALL CONTINOUS LOADS
 ARE SHOWN AT 125%. (HEAT PUMP AND POOL
 PUMP) IF THE LOAD IS ALREADY SHOWN AT
 125%, PLEASE NOTE.
 220,680.9,215.3,230.42
  
 21) NOTE: PLEASE SEE LOAD CALCULATIONS
 SHOW PANELS AS 40CIR AND PANELS ARE
 42CIR. (MISPRINT/CORRELATE).
 106.1.2
  
 22) NOTE: PLEASE KNOW PLANS HAVE BEEN
 SUBMITTED FIVE TIMES FOR REVIEW FOR THIS
 SINGLE FAMILY RESIDENCE.
 PLEASE KNOW ALL FIVE SETS OF ELECTRICAL
 PLANS ARE BEING RETAINED. PLEASE ALSO
 KNOW PLANS MAY BE TURNED OVER TO THE
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS
 FOR PEIR REVIEWFOR REPEATED COMMENTS FOR
 NON-COMPLIANCE.
 PLEASE ALSO SEE COPY OF FS 553.80(2)(B)
 WITH RESPECT TO DESIGN PROFESSIONALS AND
 REPEAT COMMENTS FOR CODE COMPLIANCE.
 PLEASE KNOW THAT IF ANY OF THE SAME CODE
 COMPLIANT COMMENTS ARE STILL NOT
 ADDRESSED ON THE NEXT RESUBMITTAL, THIS
 OFFICE WILL HAVE NO CHOICE TO ASSESS A
 4X FEE FOR THE PLAN REVIEW PORTION OF
 THE PERMIT FEE.
 PLEASE SEE THIS FINE WILL BE $10,860.00
 WHICH IS REQUIRED UNDER FLORIDA STATUES
 TO BE PAID BY THE DESIGN PROFESSIONAL(S)
 OF RECORD. THIS FINE IS "NOT" THE
 RESPONSIBILTY OF THE OWNER OR
 CONTRACTOR.
 PLEASE KNOW THIS OFFICE IS GIVING NOTICE
 THAT A MEETING IS REQUIRED AND SHALL BE
 HELDWITH THEATTENDANCE OF THE
 FOLLOWING PERSONS AT A MINIMUM: GARRISON
 DESIGN GROUP, MR. LUIS LOPEZ (ENGINEER
 OF RECORD) AND GENERAL CONTRACTOR.
  
 23) NOTE: PLEASE KNOW, UPON REVIEW OF
 THE SUBMITTED PACKAGE THE ORIGINAL
 PERMIT APPLICATION COULD NOT BE READILY
 FOUND. PLEASE BE SURE THIS APPLICATION
 IS LOCATED AND SUBMITTED WHEN
 RESUBMITTING PLANS.
 PLEASE ALSO KNOW THAT ANY NOTICE OF
 COMMENCEMENTS NOT RECORDED WITHIN 90
 DAYS OF ISSUANCE OF THE PERMMIT WILL
 REQUIRE THE NOC TO BE RE-RECORDED PER FS
 713.13(2). PER FS AS NOTED, IF WORK HAS
 NOT COMMENCED WITHIN 90 DAYS OF
 RECORDING SUCH NOC, THE NOC SHALL BECOME
 VOID.
 IF THERE ARE ANY QUESTIONS ON THIS,
 PLEASE CALL.
  
 ** PLEASE BE SURE TO CAREFULLY STAPLE
 ALL NEW SETS , AS THE SETS WERE ATTACHED
 THROUGH THE PANEL SCHEDULES CAUSING
 THESE TO BE TORN FOR REVIEW. PLEASE ALSO
 TO SUBMIT TWO COMPLETE AND CLEAN SETS
 FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2006-08-11 Time   Rev Time 0.00
Received By btrobaug Date 2006-07-14 Time 07:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-07-05 Cont ID  
Sent By btrobaug Date 2006-07-05 Time 10:21 Rev Time 1.00
Received By btrobaug Date 2006-07-05 Time 06:30 Sent To M
Notes
2006-07-05 00:00:00 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE LOAD CALCULATION @218.5 AMPS
 EXCEEDS THE SERVICE SIZE OF 200 AMPS.
 230.31 SIZE AND RATING.
 (A) GENERAL. SERVICE-LATERAL CONDUCTORS
 SHALL HAVE SUFFICIENT AMPACITY TO CARRY
 THE CURRENT FOR THE LOAD AS COMPUTED IN
 ACCORDANCE WITH ARTICLE 220 AND SHALL
 HAVE ADEQUATE MECHANICAL STRENGTH.
 SUGGEST LARGER SERVICE.
  
 2} THE 3/0 FEEDERS FOR 250 AMPS DOES NOT
 COMPLY WITH 310.15(B)(6).
  
 3} THE GROUNDING ELECTRODE CONDUCTOR
 MUST BE SIZED PER 250.66, MINIMUM OF A
 #2 COPPER FOR 250 AMP OCP.
  
 4} THE FEEDER FOR PANEL "B" IS NOT
 LISTED IN PANEL "A".
  
 5} THE SMALL APPLIANCE CIRCUITS @ 2400
 VA ARE TOO LARGE FOR A 20 AMP CIRCUIT
 SEE 220.16 FOR LOAD CALCULATION
 REQUIREMENTS, SMALL APPLIANCE.
  
 6} THE LAUNDRY CIRCUIT CALCULATION
 REQUIRED BY 220.16(B), IS NOT IN THE
 LOAD CALCULATION.
  
 7} THE A/C CALCULATIONS ON THE
 ELECTRICAL PLAN DOES NOT CORRESPOND TO
 THE MECHANICAL PLAN. PLEASE CORRELATE
 SAME.
  
 8} PLEASE SEE THE GFI LOCATED IN THE
 SINK IN THE CABANA BATH.
  
 9} BEDROOMS 1 AND 3 NEED A RECEPTACLE
 ADDED PER 210.52(A)(1).
  
 10} PLEASE INSERT ALL NEW PAGES INTO ONE
 COMPLETE SET OF PLANS WHEN RESUBMITTING.
 ALSO DO NOT RESUBMIT SHEETS FROM OLD
 REVIEWS OTHER THAN THE PREVIOUS REVIEW,
 REMOVE ALL OTHERS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-06-12 Cont ID  
Sent By btrobaug Date 2006-06-12 Time 18:03 Rev Time 0.75
Received By btrobaug Date 2006-06-12 Time 17:30 Sent To M
Notes
2006-06-12 00:00:00 
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE LOAD CALCULATION @254 AMPS
 EXCEEDS THE SERVICE SIZE OF 200 AMPS.
 230.31 SIZE AND RATING.
 (A) GENERAL. SERVICE-LATERAL CONDUCTORS
 SHALL HAVE SUFFICIENT AMPACITY TO CARRY
 THE CURRENT FOR THE LOAD AS COMPUTED IN
 ACCORDANCE WITH ARTICLE 220 AND SHALL
 HAVE ADEQUATE MECHANICAL STRENGTH..
  
 2} PROVIDE PANEL SCHEDULES FOR PANELS
 "A" AND "C". 408.4 NEC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-04-12 Cont ID  
Sent By btrobaug Date 2006-04-12 Time 10:47 Rev Time 0.50
Received By btrobaug Date 2006-04-12 Time 07:32 Sent To P
Notes
2006-04-12 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE IS NO CONSIDERATION FOR FUTURE
 EXPANSION REGARDING THE SERVICE SIZE OF
 200 AMPS WITH A CORRECTED CALCULATED
 LOAD OF 209 AMPS. SEE ARTICLE 220 NEC.
  
 2} THE RISER INDICATES A METER/MAIN
 COMBINATION SERVICE, BUT THE EQUIPMENT
 SHOWN AT LOCATION ON THE PLAN ARE STAND
 ALONE, PLEASE CLARIFY.
  
 3} THE DISCONNECT LOCATION FOR THE
 CONDENSING UNITS DO NOT MEET 110.26
 SPACING REQUIREMENTS.
  
 4} SEE SOME BATHROOMS NOT COMPLY WITH
 210.52(D).
  
 NOTES FROM PREVIOUS REVIEW:
  
 3} THE NOTE REGARDING "RECEPTACLES ON
 ARC FAULT CIRCUITS" SHOULD READ
 "OUTLETS", SEE PRIOR COMMENT AND SEE
 210.12.
  
 6} THERE ARE SEVERAL ROOMS WHERE THE
 RECEPTACLE SPACING DOES NOT COMPLY WITH
 210.52(A)(1&2). SEE REVIEWED SET OF
 PLANS FOR APPROXIMATE LOCATIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-10 Cont ID  
Sent By btrobaug Date 2006-01-10 Time 09:43 Rev Time 1.00
Received By btrobaug Date 2006-01-10 Time 07:13 Sent To Z
Notes
2006-01-10 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE A RISER DIAGRAM, SERVICE
 EQUIPMENT LOCATIONS AND PANEL SCHEDULES
 PER 215.5.
  
 2}REGARDING THE NOTE REFERRING TO
 SMOKE DETECTORS, THEY MUST BE ON AN ARC
 FAULT BREAKER PER 210.12.
  
 3} THE NOTE REGARDING "RECEPTACLES ON
 ARC FAULT CIRCUITS" SHOULD READ
 "OUTLETS", SEE PRIOR COMMENT AND SEE
 210.12.
  
 4} THERE IS NO ELEVATOR EQUIPMENT IN THE
 CALCULATIONS, BUT ONE SHOWN ON THE PLAN.
 SEE ARTICLE 620.
  
 5} PLEASE SHOW THE LOCATION OF ALL
 EQUIPMENT ON THE PLAN. POOL PUMPS,
 CONDENSING UNITS ETC. SO THAT DISCONNECT
 LOCATIONS AND SERVICE RECEPTACLE
 PLACEMENT CAN BE REVIEWED.
  
 6} THERE ARE SEVERAL ROOMS WHERE THE
 RECEPTACLE SPACING DOES NOT COMPLY WITH
 210.52(A)(1&2). SEE REVIEWED SET OF
 PLANS FOR APPROXIMATE LOCATIONS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2008-04-28 Cont ID  
Sent By adarroug Date 2008-04-28 Time 09:42 Rev Time 0.00
Received By adarroug Date 2008-04-28 Time 09:42 Sent To Z
Notes
2008-04-28 09:42:47TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-11-08 Cont ID  
Sent By adarroug Date 2007-11-08 Time 11:32 Rev Time 0.00
Received By adarroug Date 2007-11-08 Time 11:32 Sent To E
Notes
2007-11-08 11:33:08TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-08-22 Cont ID  
Sent By adarroug Date 2007-08-22 Time 16:34 Rev Time 0.00
Received By adarroug Date 2007-08-22 Time 16:34 Sent To E
Notes
2007-08-22 16:34:29TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-08-06 Cont ID  
Sent By adarroug Date 2007-08-06 Time 17:18 Rev Time 0.00
Received By adarroug Date 2007-08-06 Time 17:18 Sent To E
Notes
2007-08-06 17:19:03TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-06-13 Cont ID  
Sent By adarroug Date 2007-06-13 Time 09:05 Rev Time 0.00
Received By adarroug Date 2007-06-13 Time 09:05 Sent To M
Notes
2007-06-13 09:06:47TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-05-11 Cont ID  
Sent By adarroug Date 2007-05-11 Time 16:56 Rev Time 0.00
Received By adarroug Date 2007-05-11 Time 16:56 Sent To M
Notes
2007-05-11 16:56:57TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-03-01 Cont ID  
Sent By adarroug Date 2007-03-01 Time 16:12 Rev Time 0.00
Received By adarroug Date 2007-03-01 Time 16:12 Sent To B
Notes
2007-03-01 16:13:21TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-08-11 Cont ID  
Sent By adarroug Date 2006-08-11 Time 11:50 Rev Time 0.00
Received By adarroug Date 2006-08-11 Time 11:50 Sent To E
Notes
2006-08-11 00:00:00TO "BTROBAUG" DESK/RESUB
 PLANS ROUTED TO DVP'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-07-13 Cont ID  
Sent By adarroug Date 2006-07-13 Time 11:24 Rev Time 0.00
Received By rbrown Date 2006-07-13 Time 11:24 Sent To M
Notes
2006-07-22 00:00:00BILL TROBAUGH DID NOT REVIEW THIS PRIOR
 TO HIS DEPARTURE.IT HAS NOW BEEN
 ROUTED TO MECHANICAL AND THE OTHER
 TRADES.IT WILL BE RETURNED TO
 ELECTRICAL FOR REVIEW UPON BILL'S
 RETURN.
  
  
2006-07-13 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-06-26 Cont ID  
Sent By adarroug Date 2006-06-26 Time 11:57 Rev Time 0.00
Received By adarroug Date 2006-06-26 Time 11:57 Sent To E
Notes
2006-06-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-06-12 Cont ID  
Sent By adarroug Date 2006-06-12 Time 10:46 Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 10:46 Sent To E
Notes
2006-06-12 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-31 Cont ID  
Sent By adarroug Date 2006-05-31 Time 09:26 Rev Time 0.00
Received By adarroug Date 2006-05-31 Time 09:26 Sent To Z
Notes
2006-05-31 00:00:00TO "Z" BOX/NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-04-06 Cont ID  
Sent By adarroug Date 2006-04-06 Time 10:23 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 10:23 Sent To E
Notes
2006-04-06 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-29 Cont ID  
Sent By adarroug Date 2006-03-29 Time 15:37 Rev Time 0.00
Received By adarroug Date 2006-03-29 Time 15:37 Sent To Z
Notes
2006-03-29 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-17 Cont ID  
Sent By adarroug Date 2006-01-17 Time 14:37 Rev Time 0.00
Received By adarroug Date 2006-01-17 Time 14:37 Sent To Z
Notes
2006-01-17 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-03 Cont ID  
Sent By alange Date 2006-02-03 Time 07:34 Rev Time 0.00
Received By alange Date 2006-01-06 Time 11:38 Sent To  
Notes
2006-01-06 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2007-06-13 Cont ID  
Sent By tgordon Date 2007-06-13 Time 13:33 Rev Time 0.30
Received By tgordon Date 2007-06-13 Time 13:33 Sent To  
Notes
2007-06-13 13:38:10** REVISION TO MECHANICAL PLANS **
 *** PROVISO ***
 1) PROVIDE FOR COMBUSTION OR MAKE-UP AIR TO GAS CLOTHES
 DRYER, SEE 2004 FBC/R M1701.1 AND M1701.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2007-05-16 Cont ID  
Sent By tgordon Date 2007-05-16 Time 09:30 Rev Time 0.45
Received By tgordon Date 2007-05-16 Time 09:30 Sent To B
Notes
2007-05-16 09:58:55REVISION TO MECHANICAL PLANS
 *** DENIED ***
 1) INFORMATION MISSING FROM TITLE BLOCK.
 SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET
 CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE
 NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND
 LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS
 AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE
 ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT.
  
 2) ROOMS ARE SHOWING AS BOXES WITH NO DOORS, PLEASE
 SUBMIT PLANS THAT SHOW ROOMS WITH DOORS, HALLWAYS ETC,
 AND LABEL ROOMS (BEDROOM, LIVING ROOM, KITCHEN, ETC).
  
 3) PLEASE SHOW AN A/C EQUIPMENT LISTING WITH ALL
 PERTINENT INFORMATION ON PLANS.
  
 4) PLEASE LABEL SECOND FLOOR.
  
 5) PLEASE SHOW ALL GAS APPLIANCES ON PLANS AND SHOW HOW
 THEY GETTING COMBUSTION AIR AND MAKE UP AIR, SEE 2004
 FBC/R M1701.
  
 6) PLEASE STATE ON PLANS WHICH AIR HANDLERS ARE IN THE
 ATTIC.
  
 7) PROVIDE RETURN AIR FOR BEDROOM #2, SEE 2004 FBC/R
 M1602.4.
  
 8) SEE YELLOW HIGH LIGHTED SUPPLY AIR DUCTS ON
 MECHANICAL PLANS, PLEASE SHOW SIZE OF DUCTS.
  
 9) SHOW LOCATION OF A/C CONDENSER UNITS ON PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2006-08-14 Cont ID  
Sent By tgordon Date 2006-08-14 Time 09:33 Rev Time 0.30
Received By tgordon Date 2006-08-14 Time 09:33 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2006-07-24 Cont ID  
Sent By tgordon Date 2006-07-24 Time 10:21 Rev Time 1.20
Received By tgordon Date 2006-07-24 Time 10:21 Sent To B
Notes
2006-07-24 00:00:00*** DENIED ***
 1) AHU #1 12" TRUNK LINE IS TO SMALL FOR
 907 CFM'S SEE MANUAL 'J' CALCULATIONS
 MAX. VELOCITY 900 FPM, THEREFORE 14"
 WOULD BE REQUIRED. AND THE 10" TRUNK
 LINE WOULD NEED TO BE 12", PLESE
 CORRECT.
  
 2) A/C SYSTEM #3 IS LISTED AS A 3.5 TON
 BUT IS A 2.5 TON PLEASE CORRECT.
  
 3) SEE 4" DUCT TO MEDIA ROOM AND 8" DUCT
 TO WALKIN CLOSET, PLEASE CORRECT.
  
 4) IS AHU #1 GOING IN THE PANTRY OR IN
 THE ALOSET WITH THE WATER HEATER, SEE
 ELECTRICAL PLANS AND MECHANICAL PLANS,
 PLEASE CORRECT.
  
 5) SEE 7" DUCT TO HIS CLOSET, PLANS ALSO
 SHOW (2)6X6 1W 30 CFM, PLEASE CORRECT.
  
 6) AHU IN MASTER SUITE IS MARKED AS AHU
 #2 BUT IS AHU #3, PLEASE CORRECT.
  
 7) AHU OVER UTILITY ROOM IS MARKED AS
 AHU #3, BUT IS AHU #2, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-07-05 Cont ID  
Sent By tgordon Date 2006-07-05 Time 15:53 Rev Time 1.20
Received By tgordon Date 2006-07-05 Time 15:53 Sent To B
Notes
2006-07-05 00:00:00*** DENIED ***
 1) PLEASE SEE MANUAL J CALCULATIONS PAGE
 7 AND CORRECT THE EQUIPMENT LISTING FOR
 A/C SYSTEM #3 (MASTER SUITE).
  
 2) PLEASE CORRECT THE EQUIPMENT LISTING
 AS TWO A/C SYSTEMS ARE LISTED AS #2.
  
 3) PLEASE SHOW ON MECHANICAL PLANS AS
 YOU HAVE ON THE ELECTRICAL PLANS, THAT
 THE GAS CLOTHES DRYER AND GAS WATER
 HEATER ARE DIRECT VENTED.
  
 4) PLEASE SEE HIGH-LITED DUCTS ON
 MECHANICAL PLANS AS SOME ARE NOT SIZED
 AND SOME ARE RUNNING INTO OTHER DUCTS
 WITH NO MIXING BOXES AND NO SIZE
 CHANGES.
  
 5) PLEASE SEE ELECTRICAL REVIEW NOTES #7
 AND #10, AND CORRECT.
  
 6) PLEASE REMOVE ALL OLD PLANS AND
 SUBMIT TWO COMPLETE SETS OF PLANS, THE
 SETS SHOULD INCLUDE ANY APPROVED STAMPED
 PAGES FROM PAST REVIEWS (PLUMBING &
 ZONING).
  
 7) PLEASE BE ADVISED THAT NOTE #6 HAS
 BEEN REQUESTED NUMEROUS TIMES BY OTHER
 DEPARTMENTS, AND SEE ATTACHED ADVISORY
 REGARDING FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-06-14 Cont ID  
Sent By tgordon Date 2006-06-14 Time 13:43 Rev Time 0.45
Received By tgordon Date 2006-06-14 Time 13:43 Sent To P
Notes
2006-06-14 00:00:00*** DENIED ***
 1) ENERGY CAL'S. NEED TO BE SIGNED BY
 OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2
  
 3) PROVIDE A/C EQUIPMENT LISTING ON
 MECHANICAL PLANS.
  
 4) PROVIDE COMBUSTION AIR OR COMBUSTION
 AIR CALCULATIOUN FOR GAS WATER HEATER
 AND GAS CLOTHES DRYER, PER 2004 FBC/R
 M1701.1 .
  
 5) PLEASE PROVIDE A APPROVED EXHAUST
 HOOD WITHDETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR GRILL IN SUMMER
 KITCHEN, OR GRILL'S MANFACTURE'S SPEC'S
 SHOWING ONE IS NOT NEEDED, PRE 2004
 FBC/M 505.3 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-01-10 Cont ID  
Sent By tgordon Date 2006-01-10 Time 12:09 Rev Time 0.20
Received By tgordon Date 2006-01-10 Time 12:09 Sent To P
Notes
2006-01-10 00:00:00NO MACHANICAL PLANS SUBMITTED FOR
 REVIEW.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-06-15 Cont ID  
Sent By jleech Date 2006-06-15 Time 13:47 Rev Time 0.00
Received By jleech Date 2006-06-15 Time 13:47 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-04-12 Cont ID  
Sent By jleech Date 2006-04-12 Time 13:42 Rev Time 0.00
Received By jleech Date 2006-04-12 Time 13:42 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-01-17 Cont ID  
Sent By jleech Date 2006-01-17 Time 08:05 Rev Time 0.50
Received By jleech Date 2006-01-17 Time 08:04 Sent To B
Notes
2006-01-17 00:00:00PROVISO;
 4" PIPE REQUIRED TO THE 1/2 BATHROOM
 BRANCH. 3" PIPE TO RUN AT A 1/4" PITCH.

Review Stop Z ZONING
Rev No 5 Status P Date 2008-04-28 Cont ID  
Sent By choops Date 2008-04-28 Time 13:53 Rev Time 0.00
Received By choops Date 2008-04-28 Time 13:53 Sent To PC
Notes
2008-04-28 13:59:20***APPROVED - LANDSCAPE PLAN SUBMITTAL***
  
 PROVISOS:
 1)PROPERTY REQUIRES: FIVE (5) SHADE/FLOWERING/FRUIT
 TREES (MINIMUM 8' HIGH WITH 5' CLEAR TRUNK SPACE), AND
 TWELVE (12) SHRUBS (MINIMUM 2 GALLON CONTAINER SIZE).
  
 2)ANY LANDSCAPING OUTSIDE OF PROPERTY LINES (WITHIN
 SWALE/PARKWAY AREA) SHALL BE APPROVED BY THE CITY'S
 ENGINEERING DEPARTMENT.
  
 3)PLANT MATERIAL SHALL BE EQUAL TO OR BETTER THAN
 FLORIDA DEPARTMENT OF AGRICULTURE NUMBER 1 NURSERY
 GRADE STANDARD.
  
 4)REQUIRED IRRIGATION SYSTEM SHALL BE INSTALLED IN
 BOTH THE YARD AND SWALE/PARKWAY AREAS PURSUANT TO
 SECTION 94-445 OF THE CITY'S ZONING AND LAND
 DEVELOPMENT REGULATIONS.

Review Stop Z ZONING
Rev No 4 Status P Date 2006-06-10 Cont ID  
Sent By mmclean Date 2006-06-10 Time 13:21 Rev Time 0.00
Received By mmclean Date 2006-06-10 Time 13:21 Sent To I
Notes
2006-06-10 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK.
  
 NOTE: MUST MAINTAIN 1000SQ FT OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-04-05 Cont ID  
Sent By mmclean Date 2006-04-05 Time 10:04 Rev Time 0.00
Received By mmclean Date 2006-04-05 Time 10:04 Sent To I
Notes
2006-04-05 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA/DECK.
  
 NOTE: MUST MAINTAIN 1000SQ FT OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-02-01 Cont ID  
Sent By mmclean Date 2006-02-01 Time 16:15 Rev Time 0.00
Received By mmclean Date 2006-01-28 Time 08:24 Sent To B
Notes
2006-02-01 00:00:002/1/06 DENIED,
 1. NEED TO REDUCE THE PROPOSED
 DRIVEWAY/WALKWAY TO MEET THE ZONING
 REQUIREMENTS.
  
 MUST MAINTAIN 1000SQ FT OR 75% WHICHEVER
 IS LESS WITHIN THE FIRST 25FT FRONT
 SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
2006-01-28 00:00:00NEED TO FIND PLANS TO PUT ALL TOGETHER &
 COMPLETE REVIEW.(ONLY RECEIVED SURVEYS
 & APPLICATION TO CHANGE FROM PLAN CHECK
 TO PERMIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-10 Cont ID  
Sent By rbrown Date 2006-01-10 Time 09:48 Rev Time 0.00
Received By rbrown Date 2006-01-10 Time 09:48 Sent To M
Notes
2006-01-10 00:00:00NO ZONING REVIEW CARRIED OUT BECAUSE
 SURVEY DRAWING WAS NOT SUBMITTED.
 SURVEY DRAWING MUST BE SUBMITTED WHEN
 THE STATUS IS CHANGED FROM 'PROJECT' TO
 'PERMIT APPLICATION'.