Plan Review Stops For Permit 06010130 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-03-14 |
Time |
10:47 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-03-14 |
Time |
10:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-08 |
Time |
07:30 |
Rev Time |
0.40 |
Received By |
alange |
Date |
2006-02-08 |
Time |
07:26 |
Sent To |
|
|
Notes |
2006-02-08 00:00:00 | DENIED | | | | 1.SHOW SLAB DETAIL AND SHOW METHOD OF | | GENERATOR ATTACHMENT TO SLAB. | | | | 2.SUBMIT TWO ORIGONAL SEALED SURVEYS, | | FS 472.025 | | | | 3.PERSON RESPOSIBLE FOR THE DESIGN | | SHALL PRINT THERE NAME AND SIGN PLANS. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-01-30 |
Time |
17:29 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-01-30 |
Time |
17:08 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FUEL |
DIESEL GENERATOR |
Rev No |
1 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-02 |
Time |
09:28 |
Rev Time |
|
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2006-04-18 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-18 |
Time |
14:26 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-04-18 |
Time |
14:26 |
Sent To |
PC |
|
Notes |
2006-04-18 00:00:00 | REVISION: USE GALVANIZED PIPE ABOVE | | GROUND INSTEAD OF PE UNDER GROUND ALONG | | WALL TO DRYER AND TANKLESS WATER HEATER |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-10 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-03-10 |
Time |
08:25 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-02 |
Time |
09:32 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2006-02-02 |
Time |
09:29 |
Sent To |
B |
|
Notes |
2006-02-02 00:00:00 | DENIED; | | ZONING MUST APPROVE LOCATION OF | | GENERATOR BEFORE GAS PLAN CAN BE | | APPROVED. | | GAS PERMIT REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-06 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-06 |
Time |
11:46 |
Sent To |
M |
|
Notes |
2006-03-06 00:00:00 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-28 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-28 |
Time |
14:27 |
Sent To |
Z |
|
Notes |
2006-02-28 00:00:00 | TO 'Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-28 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-28 |
Time |
16:07 |
Sent To |
E |
|
Notes |
2006-01-28 00:00:00 | TO "GEN-RES" BOX"E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-08 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-01-05 |
Time |
13:39 |
Sent To |
|
|
Notes |
2006-01-05 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-03-06 |
Time |
13:32 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-03-06 |
Time |
13:32 |
Sent To |
P |
|
Notes |
2006-03-06 00:00:00 | *** PROVISO *** | | 1)GENERATOR EXHUST MUST BE TEN FEET AWAY | | FROM ANY BUILDING OPENINGS (WINDOWS, | | DOORS, ROOF & EAVE VENTS), AND TEN FEET | | AWAY FROM ADJECENT BUILDING OPENS. PER | | 2004 FBC/M 401.5.1 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-31 |
Time |
16:14 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-01-31 |
Time |
16:14 |
Sent To |
G |
|
Notes |
2006-01-31 00:00:00 | *** DENIED *** | | 1) PLANS OF GENERATOR LOCATION ARE | | DIFFICULT TO READ DUE TO SIZE AND AMOUNT | | OF INFOMATION ON THEM. | | CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-02 |
Time |
09:28 |
Rev Time |
|
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-03-06 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-03-06 |
Time |
10:35 |
Sent To |
I |
|
Notes |
2006-03-06 00:00:00 | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | INTO A SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-27 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-27 |
Time |
13:20 |
Sent To |
B |
|
Notes |
2006-01-27 00:00:00 | DENIED, | | 1. MUST PROVIDE TWO CURRENT COPY OF | | SURVEY, SHOWING THE LOCATION OF WORK. | | 2. SURVEY PROVIDED IS OVER A 1YR OLD. | | (1972). | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|