Plan Review Stops For Permit 05121233 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-07-20 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-20 |
Time |
08:05 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-07-20 |
Time |
08:05 |
Sent To |
|
|
Notes |
2006-07-20 00:00:00 | STRUCTURAL REVISIONS OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-30 |
Time |
14:05 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-05-30 |
Time |
14:04 |
Sent To |
|
|
Notes |
2006-05-30 00:00:00 | STRUCTURAL REV. OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-02 |
Time |
08:07 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-05-02 |
Time |
08:07 |
Sent To |
|
|
Notes |
2006-05-02 00:00:00 | FOUNDATION REVISION OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-03-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-03-28 |
Time |
08:59 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2006-03-28 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-28 |
Time |
08:28 |
Rev Time |
2.00 |
Received By |
alange |
Date |
2006-02-28 |
Time |
08:27 |
Sent To |
|
|
Notes |
2006-02-28 00:00:00 | DENIED | | | | 1.ALL PLANS SUBMITTED AFTER OCTOBER, | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | FLORIDA BUILDING CODE. | | | | 2. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 3.ALL PRODUCT APPROVALS SUBMITTED | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | APPROVAL ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 4.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMMENDMENT TO FBC 106.3.3 | | | | 5.PRODUCT APPROVALS REQUIRED FOR | | LINTELS AND STRAPS AND TIE-DOWNS. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-04-12 |
Time |
13:13 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-04-12 |
Time |
13:02 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-03-23 |
Time |
17:00 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-03-23 |
Time |
16:47 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-01-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-01-13 |
Time |
16:48 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-01-13 |
Time |
16:28 |
Sent To |
P |
|
Notes |
2006-01-13 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PLEASE PROVIDE A CALCULATION INCLUDI- | | NG ALL ADDED LOADS IMPOSED,ALL EXISTING | | LOADS AND THE EXISTING OR PROPOSED | | SERVICE SPECIFICATIONS PER 215.15. | | | | 2} THE PERSON RESPONSIBLE FOR THE | | DRAWINGS MUST PRINT AN DSIGN NAME ON | | SAME. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-07 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-07 |
Time |
14:40 |
Sent To |
B |
|
Notes |
2006-07-07 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-05-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-27 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-27 |
Time |
14:17 |
Sent To |
B |
|
Notes |
2006-05-27 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-25 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-25 |
Time |
14:48 |
Sent To |
B |
|
Notes |
2006-04-25 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-04 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2006-04-04 |
Time |
15:36 |
Sent To |
P |
|
Notes |
2006-04-04 00:00:00 | AS OF 3/31/06 PLANS ON "BTROBAUG" DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-23 |
Time |
16:34 |
Sent To |
E |
|
Notes |
2006-03-23 00:00:00 | TO BT'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-09 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-09 |
Time |
13:27 |
Sent To |
Z |
|
Notes |
2006-03-09 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-01-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-12 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-12 |
Time |
14:06 |
Sent To |
E |
|
Notes |
2006-01-12 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-28 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-02-28 |
Time |
08:59 |
Sent To |
|
|
Notes |
2005-12-30 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2006-01-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-24 |
Time |
11:06 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-01-24 |
Time |
11:06 |
Sent To |
B |
|
Notes |
2006-01-24 00:00:00 | NO MECH. PLANS OR MECH. CONTRACTOR | | SUBMITTED AT THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-03-31 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-31 |
Time |
15:26 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-03-31 |
Time |
15:25 |
Sent To |
E |
|
Notes |
2006-03-31 00:00:00 | | | | | | | | | ******PROVISO****** | | 604.9 WATER HAMMER. THE FLOW VELOCITY OF | | THE WATER DISTRIBUTION SYSTEM SHALL BE | | CONTROLLED TO REDUCE THE POSSIBILITY OF | | WATER HAMMER. A WATER-HAMMER ARRESTOR | | SHALL BE INSTALLED WHERE QUICK-CLOSING | | VALVES ARE UTILIZED. WATER-HAMMER | | ARRESTORS SHALL BE INSTALLED IN | | ACCORDANCE WITH MANUFACTURE'S | | SPECIFICATIONS. WATER-HAMMER ARRESTORS | | SHALL CONFORM TO ASSE 1010. | | ********************************* |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-27 |
Time |
13:47 |
Rev Time |
1.00 |
Received By |
mperson |
Date |
2006-03-27 |
Time |
13:47 |
Sent To |
B |
|
Notes |
2006-03-27 00:00:00 | ****DENIED 2ND TIME**** | | REFERENCE:FBC-2004 PLUMBING, AND CITY OF | | WESR PALM BEACH, AMENDMENTS TO FBC-2004, | | CHAPTER 1, ADMINISRATION: | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | 1. UTL-SINK SHOWN ON PLUMBING ISOMETRIC | | DRAWING ON SHEET E-1 CAN NOT DISCHARGE | | INTO A BATHROOM GROUP. MUST BE | | DOWNSTREAM OF BATHROOM GROUP, PER | | FBC-2004 PLUMBING SEC. 909.1. PLEASE | | CORRECT. | | 2. TUB SHOWN ON PLUMBING ISOMETRIC DRAW- | | ING ON SHEET E-1 IS NOT VENTED, SHOULD | | BE PART OF BATHROOM GROUP. PLEASE | | CORRECT. | | 3. ITEM #14 PLUMBING NOTES ON E-1. AIR | | CHAMBERS ARE NOT TO CODE, MUST BE WATER | | HAMMER ARRESTERS TO BE INSTALLED PER | | FBC-2004 PLUMBING SEC. 604.9. PLEASE | | CHANGE NOTES TO REFLECT THIS. | | 4. PER 708.3.4, A CLEANOUT SHALL BE | | PROVIDED AT THE BASE OF EACH WASTE OR | | SOIL STACK. THE PLUMBING ISOMETRIC | | DRAWING ON SHEET E-1 DOES NOT INDICATE | | THIS, PLEASE CORRECT. | | 5. PLUMBING ISOMETRIC SHOWN ON E-1 | | INDICATES BUILDING SEWER INSTALLED | | PARALLEL TO THE OUTSIDE OF THE BUILDING | | WITH BRANCHES TO THE FIXTURES ON INSIDE | | OF BUILDING. NOTE: PER 708.3.5 BUILDING | | DRAIN AND BUILDING SEWER JUNCTION, THERE | | SHALL BE A CLEANOUT NEAR THE JUNCTION OF | | THE BUILDING DRAIN AND THE BUILDING | | SEWER. PLEASE CORRECT DRAWING TO REFLECT | | THIS. | | 6. PER CHAPTER 1, SEC. 106 , SHEET E-1 | | DRAWING NEEDS TO BE SIGNED BY DESIGNER. | | 7. NOTE: CHANGES TO BE IDENTIFIED BY | | TRIANGLES, CLOUDS OR OTHER AND NOTE ON | | REVISIONS ON DRAWING. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-01-24 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-01-24 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-01-24 |
Time |
10:30 |
Sent To |
M |
|
Notes |
2006-01-24 00:00:00 | DENIED; | | 1. SANITARY RISER DIAGRAM DOESNOT MATCH | | FLOOR PLAN. | | 2.RISER DIAGRAM SHOWS 2- TUBS NO SHOWER. | | 3.RISER DIAGRAM SHOWS 2 WASHERS. | | 4.W/M AND L/T CANNOT DISCHARGE INTO A | | BATHROOM GROUP. MUST BE DOWN STREAM OF | | BATHROOM. FBC-2004 SEC. 909.1. | | 5.WATER HEATER SHOULD NOT BE SHOWN ON | | SAN.RISER. | | 6.VENTING ON SAN.RISER IS NOT TO CODE. | | 7.AIRCHAMMBERS ARE NOT TO CODE, MUST BE | | WATER HAMMER ARRESTORS TO BE INSTALL PER | | FBC-2004 PLUMBING SEC.604.9. | | 8. THE BRANCH DRAIN TO THE W/M MUST BE | | 3" PER SEC.406.3. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-03-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-03-22 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-03-22 |
Time |
14:55 |
Sent To |
I |
|
Notes |
2006-03-22 00:00:00 | NOTE: THE PROPOSED ADDITION MUST SIT | | BEYOND THE 25FT FRONT SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-01-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-11 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-11 |
Time |
18:09 |
Sent To |
I |
|
Notes |
2006-01-11 00:00:00 | DENIED, | | 1. THE PROPOSED ADDITION MUST SIT 25FT | | FROM THE FRONT SETBACK. SURVEY SHOWS | | 24.6' | | 2. SUBMIT TWO NEW SURVEY SHOWING THE | | PROPOSED ADDITION MOVED BACK 25FT FROM | | THE FRONT SETBACK. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|