Plan Review Details - Permit 05121117
Plan Review Stops For Permit 05121117 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-01-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-01-06 |
Time |
13:54 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-01-06 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-29 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-29 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2005-12-30 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2005-12-30 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
14:12 |
Sent To |
M |
|
Notes |
2006-02-06 00:00:00 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-01-06 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-12-28 |
Time |
08:41 |
Sent To |
|
|
Notes |
2005-12-28 00:00:00 | TO "BOB"#7 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-02-07 |
Time |
11:11 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-02-07 |
Time |
11:11 |
Sent To |
|
|
Notes |
2006-02-07 00:00:00 | MECH. PLANS VOIDED AND WILL BE SUBMITTED | | AT A LATER DATE SO MASTER PERMIT WILL GO | | THROU. NO MECH. PERMIT NUMBER APPLIED | | FOR AT THIS TIME. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-01-04 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-01-04 |
Time |
13:28 |
Sent To |
|
|
Notes |
2006-01-04 00:00:00 | DENIED: | | 1.RETURN AIR FROM BATHROOM AREAS SHALL | | NOT BE RECIRCULATED PER 2004 FMC 407.1. | | | | 2.PLAN SHEET 7 OF 8 INDICATES 150 CFM | | OF EXHAUST FROM THE MENS RESTROOM/SHOWER | | AREA.PER 2004 FMC TABLE 403.3, A TOTAL | | OF 200 CFM IS REQUIRED FROM THE MENS | | ROOM. | | | | 3.PROVIDE MANUFACTURER INFORMATION OR | | SPECIFICATIONS FOR THE EXHAUST FAN. | | PLANS DOES NOT INDICATE IF THE EXHAUST | | FAN IS NEW OR EXISTING. | | | | 4.PLAN SHEET 7 OF 8 INDICATES SUPPLY | | AND RETURN AIR DUCT GOINX DOWN TO THE | | 1ST FLOOR IN AN EXISTING OPENING. | | PLEASE CLARIFY IF THIS PENETRATION IS | | RATED.SHOW COMPLIANCE WITH 2004 FMC | | 607.6.1 & 607.8 OR 607.6.3. | | | | 5.PLEASE PROVIDE OUTSIDE AIR | | CALCULATIONS IN ACCORDANCE WITH 2004 FMC | | TABLE 403.3. | | | | 6.PLAN SHEET 8 OF 8, DETAIL FOR THE | | AHU SHOWS A "SAFE-T-SWITCH" ON THE | | AUXILIARY DRAIN LINE.PLEASE INDICATE | | IF THE AHU HAS A BOTTOM RETURN.PLEASE | | INDICATE IF THE RETURN AIR IS A DUCTED | | BOTTOM RETURN OR SHOW COMPLIANCE WITH | | 2004 FMC 307.2.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-03 |
Time |
11:34 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-01-03 |
Time |
11:45 |
Sent To |
|
|
Notes |
2006-01-03 00:00:00 | *** DENIED *** | | 1) RETURN AIR CAN NOT COME FROM A PUBLIC | | RESTROOM, PER 2004 FBC/M 407.1 . | | | | 2) PLEASE PROVIDE FOR SUPPLY VENTILATION | | AIR, PER 2004 FBC/M 403.1 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-03 |
Time |
11:45 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2006-01-04 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
|