Plan Review Stops For Permit 05120992 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-09-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-09-07 |
Time |
18:11 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-09-07 |
Time |
18:11 |
Sent To |
PC |
|
Notes |
2006-09-07 00:00:00 | PERMIT UNDER 'P'. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-07-10 |
Time |
10:07 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-07-10 |
Time |
09:22 |
Sent To |
|
|
Notes |
2006-07-10 00:00:00 | BUILDING REVIEW 4TH CHECKLIST: | | 1- SAME ITEM FROM PREVIOUS CHECKLISTS. | | ENGINEER TO REVIEW AND APPROVE IN | | WRITTING ALL PRODUCT APPROVALS AS | | REQUIRED BY SECTION 106.3.3 OF CITY | | AMENDMENTS TO FBC 2004. | | | | 2- NEED RE-RECORDED NOTICE OF | | COMMENCEMENT. NOTICE OF COMMENCEMENT IS | | EXPIRED AFTER 90 DAYS IF WORK IS NOT | | STARTED. | | SEC. 713.13 (G)(2) FLORIDA STATUTES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-03-13 |
Time |
07:53 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-03-13 |
Time |
07:53 |
Sent To |
|
|
Notes |
2006-03-13 00:00:00 | BUILDING REVIEW 3RD CHECKLIST (SAME | | COMMENTS FROM 2ND CHECKLIST): | | | | 1- PROVIDE 2 SIGNED AND SEALED COPIES OF | | THE ENGINEER'S DESIGN PRESSURES | | CALCULATIONS. ONLY ONE COPY SUBMITTED. | | | | 2- AS OF 3-13-06 SINGLE HUNG FLORIDA | | PRODUCT APPROVAL FL 2742IS NOT | | APPROVED YET (SEE COPY DOWNLOADED FROM | | DCA WEBSITE ON WWW.FLORIDABUILDING.ORG). | | APPROVAL STATUS SAYS THAT MANUFACTURER | | NEEDS TO RE-APPLY. PRODUCT MUST HAVE | | APPROVED STATUS TO BE USED. | | AS AN ALTERNATIVE, MANUFACTURER MAY | | APPLY FOR CITY OF WEST PALM BEACH LOCAL | | PRODUCT APPROVAL USING THE DADE COUNTY | | NOA AND FULLY COMPLETING THE LOCAL | | PRODUCT APPROVAL FORM. SEE ATTACHED | | COPY. (PROVIDE 2 COMPLETE COPIES WITH | | APPLICANTS ORIGINAL SIGNATURES) | | | | 3- ENGINEER WHO PROVIDE THE CALCULATIONS | | ON ITEM #1 ABOVE TO REVIEW AND APPROVE | | ALL PRODUCT APPROVALS PRIOR TO SUBMITTAL | | TO THIS OFFICE AS REQUIRED BY SEC. | | 106.3.3 OF CITY AMENDMENTS TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-02-16 |
Time |
18:53 |
Rev Time |
0.40 |
Received By |
jgomez |
Date |
2006-02-16 |
Time |
18:53 |
Sent To |
|
|
Notes |
2006-02-16 00:00:00 | BUILDING REVIEW SECOND CHECKLIST: | | 1- A) ENGINEER CALCULATIONS SUBMITTED | | NEED TO HAVE ORIGINAL SEAL, SIGNATURE | | AND DATE AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES. | | | | B) PROVIDE 2 COPIES. | | | | | | 2- SINGLE HUNG FLORIDA PRODUCT APPROVAL | | FL2742 IS NOT APPROVED. APPROVAL STATUS | | SAYS THAT MANUFACTURER NEEDS TO | | RE-APPLY.PRODUCT APPROVAL MUST BE | | APPROVED IN ORDER TO BE USED. | | | | 3- ENGINEER WHO PROVIDE CALCULATIONS ON | | ITEM #1 ABOVE TO REVIEW AND APPROVE ALL | | PRODUCT APPROVALS PRIOR TO SUBMITTAL TO | | THIS OFFICE AS REQUIRED BY SEC. 106.3.3 | | OF CITY AMENDMENTS TO TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-31 |
Time |
14:47 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2006-01-31 |
Time |
14:47 |
Sent To |
|
|
Notes |
2006-01-31 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- THIS IS A HIGHRISE BUILDING. PROVIDE | | ENGINEERING CALCULATIONS FOR THE | | OPENINGS DESIGN PRESSURES AS REQUIRED BY | | SEC. 1609 FBC 2004 AND SEC. 106.1.2 OF | | CITY AMENDMENTS TO FBC 2004. | | ***NEED TO VERIFY THAT PROPOSED WINDOWS | | AND MULLIONS WILL RESIST THE CALCULATED | | DESIGN PRESSURES. | | | | 2- PROVIDE FLORIDA OR LOCAL PRODUCT | | APPROVAL AS REQUIRED BY RULE 9B-72 OF | | DCA FOR: | | A) SINGLE HUNG WINDOWS. FLORIDA | | PRODUCT APPROVAL FL2742 WAS NOT | | APPROVED. MANUFACTURER NEEDS TO | | RE-APPLY. SEE NOTE ON FL 2742 UNDER | | APPLICATION STATUTES. . | | B) WINDOW MULLIONS IF THE WINDOWS ARE | | GOING TO BE MULLED TOGETHER. | | ***NOTE: CLEARLY SPECIFY HOW ARE | | MULLIONS GOING TO BE ANCHORED TO VERIFY | | COMPLIANCE WITH THE CALCULATED DESIGN | | PRESSURES. SEC. 106.1.2 OF CITY | | AMENDMENTS TO FBC 2004. | | | | 3- PROVIDE RECORDED NOTICE OF | | COMMENCEMENT. | | | | 4- DESIGNER OF RECORD (SEE ITEM #2 | | ABOVE) TO REVIEW AND APPROVE THE PRODUCT | | APPROVALS AS REQUIRED BY SEC. 106.3.3 OF | | CITY AMENDMENTS TO FBC 2004 PRIOR TO | | SUBMITTAL TO THIS OFFICE. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-06 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-06 |
Time |
16:04 |
Sent To |
B |
|
Notes |
2006-09-06 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-07 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-07 |
Time |
16:36 |
Sent To |
B |
|
Notes |
2006-07-07 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-10 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-10 |
Time |
16:16 |
Sent To |
B |
|
Notes |
2006-03-10 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-02-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-10 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-10 |
Time |
09:05 |
Sent To |
B |
|
Notes |
2006-02-10 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-01-31 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2005-12-27 |
Time |
08:39 |
Sent To |
|
|
Notes |
2005-12-27 00:00:00 | TO "MISC" BOX#1 |
|
|