Plan Review Stops For Permit 05120987 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-10-20 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-10-20 |
Time |
08:26 |
Sent To |
|
|
Notes |
2006-10-20 08:26:53 | THE SITE ADDRESS FOR THE MULTI-LEVEL PARKING GARAGE IS | | CORRECT TO BE 1621 WORTHINGTON RD |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-02-02 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-02-02 |
Time |
13:30 |
Sent To |
|
|
Notes |
2006-02-02 00:00:00 | NEED SITE PLAN & PLAT BEFORE ISSUING THE | | CORRECT ADDRESS LU |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
16 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-06-22 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-06-22 |
Time |
14:17 |
Sent To |
|
|
Notes |
2007-06-22 14:17:54 | PROCESSED AS BUILT REVISIONS TO ARCHITECTURAL SHEETS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
15 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-06-18 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-06-18 |
Time |
13:38 |
Sent To |
|
|
Notes |
2007-06-18 13:44:06 | ADDITIONAL CHANGES HAVE BEEN MADE TO THESE PAGES BY THE | | REVISION WHICH WAS SUBMITTED ON 5/31/07. SEE THE NOTES | | FOR REVISION # 14 . |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
14 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-06-18 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-06-18 |
Time |
13:03 |
Sent To |
Z |
|
Notes |
2007-06-18 13:07:28 | REVISIONS/AS BUILTS TO SHEETS A1.1.0, A2.1.1, A2.1.2, | | A2.1.3, A2.2.1, A2.2.2, A2.3.1, A2.3.2, AND A2.3.3 ARE | | OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
13 |
Status |
F |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-05-02 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-05-02 |
Time |
12:05 |
Sent To |
|
|
Notes |
2007-05-02 13:00:50 | AS BUILT REVISIONS DENIED BY BUILDING | | | | 1) SUBMIT THREE (3) COMPLETE SETS OF DRAWINGS FOR | | REVIEW.FS 553.71 | | | | 2) SOME OF THE 8-1/2" X 11" SIGNED AND SEALED DRAWINGS | | FROM THE ENGINEER HAVE COPIED SIGNATURES WHICH IS NOT | | ALLOWED. SEE FAC 61G15-23.002 AND FS471.025 | | | | 3) SHOW COMPLIANCE WITH FBC 11-4.7.7 DETECTABLE | | WARNINGS. | | A CURB RAMP SHALL HAVE A DETECTABLE WARNING COMPLYING | | WITH SECTION 11-4.29.2 . THE DETECTABLE WARNING SHALL | | EXTEND THE FULL WIDTH AND DEPTH OF THE CURB RAMP. | | | | 4) SHOW COMPLIANCE WITH FBC 11-4.5.4 GRATINGS. | | IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEN THEY | | SHALL HAVE SPACES NO GREATER THAN ? INCH (13 MM) WIDE | | IN ONE DIRECTION [SEE FIGURE 11-8 (G)]. IF GRATINGS | | HAVE ELONGATED OPENINGS, THEN THEY SHALL BE PLACED SO | | THAT THE LONG DIMENSION IS PERPENDICULAR TO THE | | DOMINANT DIRECTION OF TRAVEL [SEE FIGURE 11-8 (H)]. | | | | 5) SHOW COMPLIANCE WITH FBC 11-4.29.5 DETECTABLE | | WARNINGS AT HAZARDOUS VEHICULAR AREAS. | | IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE | | WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS, | | OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND | | VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL | | BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS | | 36 INCHES (915 MM) WIDE, COMPLYING WITH SECTION | | 11-4.29.2 . | | | | 6) SHOW COMPLIANCE WITH FBC 11-4.1.2 FOR REQUIRED | | ACCESSIBLE PARKING SPACES. SEE ZONING COMMENTS. | | | | 7) PROVIDE DETAIL OF PIPE RAIL SPECIFIED IN STAIR | | DETAILS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-30 |
Time |
13:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-30 |
Time |
12:44 |
Sent To |
|
|
Notes |
2007-03-30 13:25:54 | SUBMITTAL OF SIGNED AND SEALED LIGHT POLE CALCULATIONS | | IS OK, |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-06 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-06 |
Time |
18:28 |
Sent To |
|
|
Notes |
2007-03-06 18:27:48 | SUBMITTED SHOP DRAWINGS FOR EGRESS STAIRS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-01 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-01 |
Time |
07:04 |
Sent To |
|
|
Notes |
2007-03-01 07:36:34 | DENIED BY BUILDING | | | | 1) THE EMBEDMENT POLE CALCULATIONS FROM PCSI ARE | | INCORRECT. THE CALCULATIONS THAT WERE USED ARE FROM FBC | | SECTION 1819.7.2.1 WHICH ONLY APPLIES TO THE HIGH | | VELOCITY HURRICANE ZONE. THE PROJECT IS LOCATED IN THE | | CITY OF WEST PALM BEACH, WHICH IS NOT LOCATED IN THE | | HVHZ. | | | | 2) THE LATERAL SOIL BEARING PRESSURE THAT WAS USED IN | | THE CALCULATION WAS BASED ON SEDIMENTARY ROCK. THE | | SUBSURFACE SOIL REPORT FOR THE PROJECT FROM ARDAMAN AND | | ASSOCIATES, INC. INDICATES VERY LOOSE TO MODERATELY | | DENSE SANDS UNDERLYING THE SITE. | | | | 3) THE EMBEDMENT DEPTH, HEIGHT ABOVE GROUND, MAXIMUM | | EPA, ETCON THE CUT SHEET ARE INCORRECT. SEE | | ATTACHED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-01 |
Time |
06:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-01 |
Time |
06:21 |
Sent To |
|
|
Notes |
2007-03-01 06:35:37 | DENIED BY BUILDING | | | | 1) ACCORDING TO THE TITLE BLOCK, THE SHOP DRAWINGS | | SUBMITTED FOR THE TILT WALL PANELS IS FROM JOEL R. | | MIDDLEBROOKS, THE ENGINEER OF RECORD FOR THE PROJECT | | AND NOT A SPECIALTY ENGINEER. HE SHOULD SIGN AND SEAL | | THE DRAWINGS AS REQUIRED BY FS 471. HE SHOULD NOT BE | | DOING A SHOP DRAWING REVIEW FOR GENERAL CONFORMANCE TO | | DESIGN ON HIS OWN DRAWINGS. | | | | 2)THIS IS THE SECOND TIME THESE DRAWINGS HAVE BEEN | | SUBMITTED WITHOUT BEING SIGNED AND SEALED BY THE | | ENGINEER WHO PRODUCED THEM AND WHOSE NAME APPEARS IN | | THE TITLE BLOCK. THIS IS REQUIRED BY FLORIDA STATUTE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2007-02-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-28 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-28 |
Time |
17:55 |
Sent To |
|
|
Notes |
2007-02-28 17:58:26 | WINDLOAD CALCULATIONS FOR LIGHT POLES ON TOP OF GARAGE | | AND CONCRETE BASE ANCHORING ENGINEERING IS OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2007-02-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-21 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-21 |
Time |
16:04 |
Sent To |
|
|
Notes |
2007-02-21 16:05:24 | 3) THE EMBED SHOP DRAWINGS ARE OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-21 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-21 |
Time |
15:52 |
Sent To |
|
|
Notes |
2007-02-21 16:04:18 | DENIED BY BUILDING | | | | 1)THE PRECAST COLUMN AND DOUBLE T PLANS ARE DENIED | | BECAUSE ONE OF THE THREE REQUIRED SETS IS NOT SIGNED | | AND SEALED BY THE SPECIALITY ENGINEER WHOSE TITLE BOCK | | APPEARS ON THE DRAWINGS. | | | | 2) THE TILT WALL PANEL PLANS ARE DENIED BECAUSE NONE OF | | THE THREE SETS HAVE BEEN SIGNED AND SEALED BY THE | | STRUCTURAL ENGINEER WHOSE TITLE BLOCK APPEARS ON THE | | DRAWINGS. FS 471. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-12 |
Time |
18:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-12 |
Time |
18:34 |
Sent To |
|
|
Notes |
2007-02-12 18:46:38 | SUBMITTAL OF WIND LOAD CALCULATIONS FOR LIGHT POLES ON | | TOP OF PARKING GARAGE ARE DENIED. | | | | 1) THREE SET OF SIGNED AND SEALED DRAWINGS ARE REQUIRED | | FOR THRESHOLD BUILDINGS. | | | | 2)THE ENGINEERING IS REQUIRED TO BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | STRUCTURE. | | | | 3) SUBMIT A DETAIL SPECIFYING HOW THE CONCRETE BASE | | SHOWN IN THE HAPCO DRAWING WITH 36" ANCHOR BOLTS | | EMBEDDED ARE ATTACHED TO THE STRUCTURE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-11-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-11-01 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-11-01 |
Time |
15:04 |
Sent To |
|
|
Notes |
2006-11-01 16:25:39 | BUILDING PROVISO | | | | IN ORDER TO ASSURE THAT THE FIRE SEPARATION DISTANCE | | REQUIRED BY FBC TABLE 704.8 FOOTNOTE (C) AND THE 20 | | FEET DISTANCE TOOTHER STRUCTURES REQUIRED BY FBC | | 903.6.1(2)ARE IN COMPLIANCE, THE AMENDMENT TO THE | | DECLARATION OF CONDOMINIUM, DECLARATION OF UNITY OF | | CONTROL AND DECLARATION OF RESTRICTIVE COVENANT MUST BE | | EXECUTED AND APPROVED BY THE BUILDING OFFICIAL BEFORE | | THE CERTIFICATE OF OCCUPANCY WILL BE ISSUED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-10-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-10-12 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-10-12 |
Time |
16:21 |
Sent To |
|
|
Notes |
2006-10-12 16:46:34 | | | DENIED BY BUILDING | | | | 1)THE SURVEY AND SITE PLANS DO NOT LOCATE THE | | CONDO/PROPERTY LINES 20 FEET FROM THE PARKING STRUCTURE | | AS REQUIRED BY 2004 FBC 903.6.1(2). SEE COMMENT #4 FROM | | PREVIOUS REVIEW. | | | | 2)THE LOCATION OF THE CONDO/PROPERTYLINES DO NOT | | APPEAR TO BEGREATER THAN 10 FEET AS REQUIRED BY FBC | | TABLE 708.4 FOOTNOTE (C) SUCH THAT THE AREA OF OPENINGS | | IS NOT LIMITED. SEE COMMENT #2 FROM PREVIOUS REVIEW. | | | | 3)THE SQUARE FOOTAGE ANALYSIS ON A2.0.1 STILL LISTS | | BUSINESS AND STORAGE OCCUPANCIES ON THE FIRST FLOOR. | | | | 4) SHEETS A3.2.2 AND A4.1.2 SPECIFY 3PLY MODIFIED ROOF | | COVERING. THE PRODUCT APPROVAL THAT WAS SUBMITTED IS | | FOR A BUILT UP ROOF SYSTEM. PLEASE CORRECT. | | | | 5) DETAIL 2 ON A1.1.0 SPECIFIES AN 8' HIGH GENERATOR | | SCREEN WALL AND THE SITE PLANS ON A 1.1.0 AND A1.1.1 | | SHOW THE WALL AS6'. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-07-05 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-07-05 |
Time |
12:36 |
Sent To |
|
|
Notes |
2006-07-05 00:00:00 | DENIED BY BUILDING | | | | 1621 WORTHINGTON ROAD | | 5 STORY PARKING GARAGE | | TYPE II-B (SPRINKLERED)(PER PLANS) | | MIXED OCCUPANCY (S-2 STORAGE & BUSINESS) | | FLOOD ZONE A9 BFE 13' (+ 6" CITY REQ.) | | REQUIRED SOIL BEARING PER PLANS 8,000 | | PSF. | | | | 1) THE STRUCTURE IS LOCATED IN AN A9 | | FLOOD ZONE AN ELEVATION CERTIFICATE WILL | | BE REQUIRED. ALL EQUIPMENT MUST ALSO BE | | LOCATED 6" ABOVE BFE. | | | | 2) THE PROPERTY LINES HAVE BEEN CHANGED | | BY A DECLARATION OF CONDOMINIUM ON FILE | | WITH THE PROPERTY APPRAISER. THE NEW | | PROPERTY CONTROL NUMBER THAT HAS BEEN | | ASSIGNED IS PCN 74-43-43-29-22-000-0030. | | | | SEE ATTACHMENT. THESE NEW PROPERTY LINES | | ARE THE ONES THAT THE FIRE SEPARATION | | DISTANCES WILL BE BASED ON. PROVIDE A | | SITE PLAN/SURVEY WITH THE DISTANCES FROM | | THE BUILDING TO THE "CONDO" PROPERTY | | LINES SPECIFIED. BASED ON THE LOCATIONS | | OF THE "CONDO" PROPERTY LINES, THE | | STRUCTURE DOES NOT COMPLY WITH FBC 704.8 | | FOR ALLOWABLE AREA OF OPENINGS. NOTE: | | FOOTNOTE C TO TABLE 704.8 ALLOWS | | UNLIMITED OPENING AREAS FOR OPEN PARKING | | STRUCTURES WITH A FIRE SEPARATION OF | | GREATER THAN 10 FEET. | | | | 3)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | THE FOUNDATION PLANS SUBMITTED TO THE | | COUNTY DID NOT SPECIFY THE FUTURE 2700 | | SQFT TENNANT SPACE FOR A BUSINESS. THERE | | WILL BE FEES DUE FOR THIS AREA. | | | | 4) THE FIRE SPRINKLER PLANS THAT WERE | | SUBMITTED SPECIFY THAT THE OPEN GARAGE | | IS NOT REQUIRED TO BE SPRINKLERED AND | | THAT THE TENNANT SPACE AND STORAGE/ | | EQUIPMENT ROOMS ARE SPRINKLERED. THIS IS | | NOT CORRECT. PLEASE SEE FBC 903.6.1. | | ANY BUILDING WHICH IS OF THREE STORIES | | OR MORE IN HEIGHT SHALL BE EQUIPPED WITH | | AN APPROVED AUTOMATIC SPRINKLER SYSTEM | | INSTALLED IN ACCORDANCE WITH SECTION | | 903.1 . | | EXCEPTIONS: | | 2.A STAND-ALONE PARKING GARAGE | | CONSTRUCTED WITH NONCOMBUSTIBLE | | MATERIALS, THE DESIGN OF WHICH IS SUCH | | THAT ALL LEVELS OF THE GARAGE ARE | | UNIFORMLY OPEN TO THE ATMOSPHERE ON ALL | | SIDES WITH THE PERCENTAGES OF OPENINGS | | EQUAL TO OR GREATER THAN THOSE SPECIFIED | | IN SECTION 406.3 . SUCH GARAGES SHALL BE | | SEPARATED FROM ANY OTHER STRUCTURE BY | | NOT LESS THAN 20 FEET (6096 MM). A | | STAND-ALONE PARKING GARAGE IS ONE THAT | | IS SOLELY FOR THE PARKING OF VEHICLES | | AND DOES NOT HAVE ANY OTHER OCCUPANCY | | GROUP IN THE BUILDING. | | THERE IS A BUSINESS OCCUPANCY IN THE | | BUILDING AND THE DISTANCE TO PROPERTY | | LINES IS LESS THAN 20 FEET (ANOTHER | | STRUCTURE COULD BE BUILT WITHIN 20 | | FEET). | | | | 5) THE BUILDING DATA ON SHEET A2.0.1 | | INCORRECTLY REFERENCES TABLE 500. THE | | CORRECT TABLE IS 2004 FBC TABLE 503. | | | | 6) THE BUILDING DATA ON SHEET A2.0.1 IS | | INCORRECT. SEE FBC TABLE 503. BUSINESS/ | | TYPE II-B IS LIMITED TO 4 STORIES AND | | 23,000 SQFT. PER FLOOR.STORAGE S-2/ | | TYPE II-B IS ALSO LIMITED TO 4 STORIES | | AND 26,000 SQFT PER FLOOR. | | UNLESS THE BUILDING OCCUPANCY IS | | SEPARATED BY 2 HOUR FIRE BARRIER WALLS | | AND CEILING ASSEMBLY PER FBC 302.3.2 THE | | MOST RESTRICTIVE LIMITS FOR HEIGHT AND | | AREA OF TABLE 503 BASED ON CONSTRUCTION | | TYPE AND OCCUPANCY SHALL BE APPLIED TO | | THE ENTIRE BUILDING. | | NOTE: FBC 504.2 ALLOWS HEIGHT & STORY | | INCREASES FOR A BUILDING EQUIPPED | | THROUGHOUT WITH AN APPROVED SPRINKLER | | SYSTEM IN ACCORDANCE WITH SECTION | | 903.3.1.1. | | FBC 406.3.6 ALLOWS OPEN PARKING GARAGES | | OF TYPE II CONSTRUCTION WITH ALL SIDES | | OPEN TO HAVE UNLIMITED AREA WHEN THE | | HEIGTH DOES NOT EXCEED 75 FEET. | | | | 7) FBC* (CITY AMENDMENTS)109.3.6.1 | | REQUIRES A STRUCTURAL INSPECTION PLAN TO | | BE SUBMITTED PRIOR TO THE ISSUANCE OF A | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | A THRESHOLD BUILDING. PLEASE SUBMIT A | | SIGNED AND SEALED STRUCTURAL INSPECTION | | PLAN FROM THE ENGINEER OF RECORD FOR THE | | STRUCTURE. | | | | 8) PLEASE REVISE THE REFERENCE TO | | ASCE7-98 IN THE NOTES UNDER THE GROSS | | UPLIFT AND WALL DESIGN TABLES ON S4.O. | | THE CORRECT REFERENCE IS ASCE7-02. | | | | 9) ON SHEET A8.1.1 PLEASE REPLACE SBC | | WITH FBC. | | | | 10) ON SHEET A9.1.1 PLEASE CORRECT THE | | NOTE UNDER TYPE "C" WALLS TO REFERENCE | | THE FBC AND NOT THE SFBC. ALSO CORRECT | | THE TABLE SPECIFIED. | | | | 11) FBC 11-4.6.4 VAN ACCESSIBLE PARKING | | SPACES LOCATED WITHIN A PARKING | | STRUCTURE SHALL HAVE AN ADDITIONAL SIGN | | READING ?VAN ACCESSIBLE? MOUNTED BELOW | | THE SYMBOL OF ACCESSIBILITY. SUCH SIGNS | | SHALL BE LOCATED SO THEY CANNOT BE | | OBSCURED BY A VEHICLE PARKED IN THE | | SPACE. | | | | 12) PROVIDE NOTE ON PLANS TO SHOW | | COMPLIANCE WITH FBC 3002.4, WHICH | | REQUIRES AT LEAST ONE PASSENGER ELEVATOR | | TO ACCOMMODATE AN AMBULANCE STRETCHER | | 76" LONG AND 26" WIDE IN THE HORIZONTAL | | POSITION. | | | | 13) PROVIDE NOTE ON PLANS TO SPECIFY | | THAT ELEVATOR IS TO COMPLY WITH FBC | | 11-4.10 FOR ACCESSIBILITY AND ASME | | A17.1-1990 'SAFETY CODE FOR ELEVATORS | | AND ESCALATORS'. | | | | 14) FBC 11-4.6.2 INDICATE THE ACCESSIBLE | | ROUTE OF TRAVEL FROM THE PARKING GARAGE | | TO THE ACCESSIBLE ENTRANCE OF THE | | BUILDING IT SERVES. | | | | 15) FBC 1008.1.2 REQUIRES EGRESS DOORS | | TO SWING IN THE DIRECTION OF TRAVEL | | WHERE SERVING AN OCCUPANT LOAD OF 50 OR | | MORE PERSONS. THE MIDLEVEL PLANS ON | | SHEETS A2.0.2 AND A2.2.1 SHOW DOOR 201 | | WITH THE WRONG SWING. | | | | 16) FBC 1008.1.1 REQUIRES EGRESS DOORS | | TO HAVE A MINIMUM CLEAR WIDTH OF NOT | | LESS THAN 32". ON A2.0.1 E7 THRU E10 ARE | | SPECIFIED WITH 30" WIDTHS. | | | | 17) ON SHEET A8.1.1 OPENINGS 103 & 104 | | ARE SPECIFIED AS WINDOWS W/SIDELITES AND | | AS FUTURE EGRESS DOORS. THESE SHOULD NOT | | BE LISTED AS EGRESS OPENINGS ON SHEET | | A2.0.1. PLEASE CLARIFY. | | | | 18) SUBMIT PRODUCT APPROVALS FOR THE | | ROOFING MATERIALS. PLANS SPECIFY 4 PLY | | MODIFIED HOT MOP. | | | | 19) THE EXTERIOR BUILDING ELEVATIONS | | ELEVATIONS ON SHEET A3.1.3 APPEAR TO | | SHOW TRANSOM WINDOWS ABOVE THE EXTERIOR | | STAIRWAY DOORS AT THE FIRST LEVEL. | | SPECIFY THIS IN THE DOOR SCHEDULE AND | | SUBMIT PRODUCT APPROVALS FOR THE TRANSOM | | WINDOWS AND THE STRUCTURAL MULLIONS. | | | | 20) IF THE PRODUCTS HAVE A STATE PRODUCT | | APPROVAL IN ADDITION TO THE MIAMI DADE | | NOA, PLEASE PRINT A COVER SHEET WITH THE | | FL# FROM THE STATE WEBSITE | | (WWW.FLORIDABUILDING.ORG) AND ATTACH IT | | TO THE NOA. | | | | 21) FBC 106.3.3*(CITY AMENDMENTS) | | REQUIRES PRODUCTS REGULATED BY DCA RULE | | 9B-72 TO BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD. | | PRODUCT APPROVALS SUBMITTED HAVE NOT | | BEEN APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. | | | | 22) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLAN SHEETS IN ORDER | | TO ADDRESS THE COMMENTS, PLEASE REMOVE | | THE OLD SHEETS AND INSERT THE NEW ONES. | | ONE COPY OF THE OLD PLANS SHEETS SHOULD | | BE ATTACHED TO FORM A SET OF 'OLD/VOIDED | | SHEETS' FOR COMPARISON OF REVISIONS WHEN | | REVIEWING THE RESUBMITTED PLANS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-04-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-04-18 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-04-12 |
Time |
07:04 |
Sent To |
|
|
Notes |
2006-04-17 00:00:00 | DENIED BY BUILDING | | | | 1621 WORTHINGTON ROAD | | 5 STORY PARKING GARAGE | | TYPE II-A (SPRINKLERED) | | MIXED OCCUPANCY (S-2 STORAGE & | | BUSINESS) NOTE: PLUMBING SHEET P3.4 | | INDICATES A FUTURE GYM WHICH WOULD BE AN | | ASSEMBLY OCCUPANCY. | | FLOOD ZONE A9 BFE 13' (+6"CITY REQ.) | | REQUIRED SOIL BEARING PER PLANS 2,000 | | PSF | | | | 1) STRUCTURE IS LOCATED IN AN A9 FLOOD | | ZONE AN ELEVTION CERTIFICATE WILL BE | | REQUIRED. ALL EQUIPMENT MUST ALSO BE | | LOCATED 6" ABOVE REQUIRED BFE. | | | | 2) SUBMIT A SIGNED AND SEALED SURVEY. | | INDICATE THE LOCATION OF THE ASSUMED | | PROPERTY LINE BETWEEN THE PROPOSED | | PARKING GARAGE AND THE PROPOSED BUILDING | | TO THE WEST. SEE FIRE SEPARATION | | DISTANCE FBC 702.1 AND 704.3. | | | | 3) FBC 1802.2.1AREA OF QUESTIONABLE | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | TO VERIFY THE SAFE BEARING CAPACITY OF | | THE SOIL. | | | | 4)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 5)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 6) SUBMIT FIRE SPRINKLER DRAWINGS AS | | REQUIRED BY FBC 106.3.5. | | | | 7) FBC 13-103.0ENERGY CODE COMPLIANCE | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | APPROPRIATE CODE COMPLIANCE FORMS. | | FBC 13-101.1.6SHELL BUILDINGS. | | THE WHOLE BUILDING (INCL. FUTURE TENANT | | SPACE) SHALL BE CONSIDERED.SHELL | | BUILDINGS SHALL BE SHOWN TO COMPLY WITH | | METHOD B (SEE SUB-CHAPTER 4).ALL | | ASSUMPTIONS MADE ABOUT SYSTEMS, NOT | | SHOWN ON THE CURRENT PLANS, SHALL BE | | LISTED AND APPENDED TO THE FORM 400B FOR | | SUBMITTAL.THIS WILL BE COMPARED, AT A | | LATER DATE, TO THE ACTUAL SYSTEMS | | PROPOSED BY THE FUTURE TENANT(S).THE | | ASSUMPTIONS LISTED ON THE APPENDIX SHEET | | SHALL BE AT LEAST THE MINIMUM STANDARD | | (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE | | BUILDING TO BE OCCUPIED FOR IT'S | | INTENDED PURPOSE. | | | | 8) FBC* 109.3.6.1SPECIAL INSPECTOR.A | | STRUCTURAL INSPECTION PLAN MUST BE | | SUBMITTED PRIOR TO THE ISSUANCE OF A | | BUILDING PERMIT FOR THE CONSTRUCTION OF | | A THRESHOLD BUILDING.A THRESHOLD | | BUILDING IS ANY BUILDING WHICH IS | | GREATER THAN THREE STORIES OR 50 FEET IN | | HEIGHT, OR WHICH HAS AN ASSEMBLY | | OCCUPANCY WITH 5,000 SQFT AREA AND | | GREATER THAN 500 OCCUPANTS.THREE | | COPIES OF THE PLANS AND OTHER DOCUMENTS | | WILL BE REQUIRED FOR PERMITTING | | PURPOSES. ALSO, PLEASE ARRANGE WITH | | HAROLD PISKURA (INSPECTION SERVICES | | MANAGER - TEL:561 805 6711), A MEETING | | INVOLVING THE OWNER, THRESHOLD | | INSPECTOR, JOB INSPECTOR, CONTRACTOR AND | | ENGINEER. | | | | 9)FBC* 109.3.6.4.4 ALL PLANS FOR THE | | BUILDING WHICH ARE REQUIRED TO BE SIGNED | | AND SEALED BY THE ARCHITECT OR ENGINEER | | OF RECORD CON- TAIN A STATEMENT THAT, TO | | THE BEST OF THE ARCHITECT'S PR | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | SPECIFICATIONS COMPLY WITH THE | | APPLICABLE FIRE-SAFETY STANDARDS AS | | DETERMINED BY THE LOCAL AUTHORITY IN | | ACCORDANCE WITH THIS SECTION AND 633 | | FLORIDA STATUTE. | | | | 10) FBC* 106.1.3 QUALITY OF BUILDING | | PLANS. BUILDING PLANS SHALL BE DRAWN TO | | A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER | | ACCEPTABLE MEDIUM. | | | | 11) FBC 1603.1.4WIND DESIGN DATA.THE | | PLANS SHALL STATE THE BASIC WIND SPEED, | | WIND IMPORTANCE FACTOR, WIND EXPOSURE | | CATEGORY, INTERNAL PRESSURE COEFFICIENT, | | AND EXTERIOR COMPONENT AND CLADDING | | DESIGN WIND PRESSURES.ADD THIS | | INFORMATION TO THE PLANS. INFORMATION | | LEFT BLANK ON SHEET S4.O. | | | | 12) THE EDITION OF ASCE 7 REFERENCED IN | | THE 2004 FBC IS ASCE 7-02. PLEASE REVISE | | THE EDITIONS OF ASCE 7 SPECIFIED ON | | SHEET S4.0. | | | | 13) SPECIFY ON THE PLANS IF THE | | STRUCTURE IS DESIGNED AS ENCLOSED, | | PARTIALLY ENCLOSED OR OPEN. | | | | 14) SPECIFY THE SCALE OF THE LIFE SAFETY | | PLAN FOR THE EQUIPMENT ROOMS ON SHEET | | A003. | | | | 15) SPECIFY THE NEGATIVE AND POSITIVE | | WINDLOAD PRESSURES FOR THE STOREFRONTS | | AT THE TENNANT SPACE, THE EXTERIOR DOOR | | TO THE MECHANICAL ROOMS, AND THE DOORS | | TO THE EGRESS STAIRS. FBC 1609 | | | | 16) NOTE 2 ON S5.0 IS COVERED BY A | | PRINTING ERROR. PLEASE CORRECT. | | | | 17) SUBMIT PRODUCT APPROVALS FOR THE | | DOOR AND WINDOW OPENINGS SUBJECT TO | | WINDLOADING, ROOFING MATERIALS, STORM | | PANELS, ETC. | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | PRODUCT APPROVAL NUMBER (FL###), | | AVAILABLE FROM THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE WWW. | | FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX | | (IF YOU FIND THAT THE QUOTED WEB PAGE IS | | NO LONGER AVAILABLE, PLEASE INFORM THE | | PLAN REVIEWER) | | FBC 106.3.3*(CITY AMENDMENTS) REQUIRES | | PRODUCTS REGULATED BY DCA RULE 9B-72 TO | | BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 18) SUBMIT SPECIFICATIONS FOR THE FIRE | | RATED DOORS, DOOR CLOSERS, HARDWARE, | | ETC. | | | | 19) PLEASE REVISE OCCUPANCY TYPE FOR | | FUTURE GYMNASIUM TO GROUP A (ASSEMBLY, | | A-3). REVISE OCCUPANT LOAD CALCS., | | TENANT SEPARATION, ETC. ACCORDINGLY. THE | | PARKING AREA AND STORAGE AREA ARE GROUP | | S-2 STORAGE. | | | | 20) ON SHEET S1.0 SOME OF THE SECTION | | MARKERS ARE NOT AT THE PROPER LOCATIONS. | | PLEASE CORRECT. | | | | 21) ON SHEET S2.0 THERE ARE TWO | | DIFFERENT SECTION DRAWINGS LABELED | | 5/S2.0. SECTION 6/S2.0 SHOULD BE LABELED | | AS 7/S2.0. | | | | 22) PROVIDE A COLUMN SCHEDULE. SEE NOTE | | 14 ON S1.0. | | | | 23) SHEETS S1.1 AND A1.2 HAVE SECTIONS | | MARKED X/X. PLEASE CLARIFY. | | | | 24) MARKS 5/S3.0 ON SHEET S1.1 MARK | | 6/S3.0 ON SHEET S1.2 ARE NOT AT THE | | CORRECT LOCATIONS. PLEASE CORRECT. | | | | 25) PLEASE REVISE NOTE 8.06 ON A000 TO | | COMPLY WITH THE 2004 FLORIDA BUILDING | | CODE. SEE FBC 1609.1.4. | | | | 26) THE NUMBERS OF PARKING SPACES LISTED | | FOR THE FIRST FLOOR ON A002 AND A003 DO | | NOT CONCUR. | | | | 27) THE ELEVATOR SHALL COMPLY WITH FBC | | 11-4.10 FOR ACCESSIBILITY AND WITH ASME | | A17.1-1990, 'SAFETY CODE FOR ELEVATORS | | AND ESCALATORS'. | | | | 28) FBC 3002.4STRETCHER ACCESSIBLE | | ELEVATOR.AT LEAST ONE PASSENGER | | ELEVATOR SHALL ACCOMMODATE AN AMBULANCE | | STRETCHER 76" LONG AND 24" WIDE IN THE | | HORIZONTAL POSITION.THIS ELEVATOR | | SHALL BE IDENTIFIED BY SIGNAGE.AMEND | | THE PLANS TO DEMONSTRATE COMPLIANCE. | | | | 29) FBC 11-4.1.2(5)(B) REQUIRES ONE IN | | EVERY EIGHT ACCESSIBLE SPACES TO BE VAN | | ACCESSIBLE AND BE DESIGNED AS REQUIRED | | BY SECTION 11-4.6.3. BASED ON THE NUMBER | | OF ACCESSIBLE SPACES, TWO VAN ACCESSIBLE | | SPACES ARE REQUIRED. FBC 11-4.6.4 | | REQUIRES VAN ACCESSIBLE SIGNAGE. FBC | | 11-4.6.5 REQUIRES 98" MINIMUM VERTICAL | | CLEARANCE AT THE VAN ACCESSIBLE PARKING | | SPACES AND ALONG THE ACCESS ROUTE TO AND | | EXITS FROM SUCH SPACES. NO SPRINKLER | | PIPING, ROOF DRAIN PIPING, ETC. WITHIN | | THE REQUIRED 98" CLEARANCE. SHOW | | COMPLIANCE. | | | | 30)FBC 406.2.2 REQUIRES THE CLEAR HEIGHT | | OF EACH FLOOR LEVEL IN VECHICAL AND | | PEDESTRIAN TRAFFIC AREAS TO BE NOT LESS | | THAN 7 FEET. | | | | 31) SHOW COMPLIANCE WITH FBC 11-4.6.2 | | INDICATE THE ACCESSIBLE ROUTE OF TRAVEL | | FROM THE PARKING GARAGE TO THE | | ACCESSIBLE ENTRANCE OF THE BUILDING IT | | SERVES.ACCESSIBLE PARKING SPACES MUST | | BE LOCATED ON AN ACCESSIBLE ROUTE NO | | LESS THAN 44" WIDE SO THAT USERS WILL | | NOT BE COMPELLED TO WALK OR WHEEL BEHIND | | PARKED VECHILES. | | | | 32) ON SHEET A003 UNDER APPLICABLE | | CODES, HIGH VELOCITY HURRICANE ZONES, | | CHAPTERS 15 & 16 DO NOT APPLY TO THIS | | PROJECT. PLEASE REVISE. CITY OF WEST | | PALM BEACH IS NOT LOCATED IN THE HVHZ. | | ALSO ON A003 THE SECTION TITLED | | HURRICANE CRITERIA CHAPTER 15 & 16 NEEDS | | TO BE REVISED. SEE NOTES ON PLANS. | | | | 33)FBC 11-4.15.2 SPECIFIES THAT | | ACCESSIBLE DRINKING FOUNTIANS SHALL BE | | NO HIGHER THAN 36" TO THE SPOUT OUTLET. | | REVISE DRINKING FOUNTAIN DRAWING ON | | A006. | | | | 34) NOTE 1 ON SHEET A006 FOR FAIR | | HOUSING GUIDELINES DOES NOT APPLY TO | | THIS PROJECT. THIS PARKING GARAGE IS NOT | | ACCESSORY TO A RESIDENTIAL OCCUPANCY. | | | | 35) THE FIRE RATING OF THE WALLS IS NOT | | INDICATED ON THE LIFE SAFETY PLANS, | | ALTHOUGH THE LEGEND IS GIVEN ON SHEET | | A003. SPECIFY THE FIRE RATINGS OF THE | | WALLS AND FLOOR/CEILINGS. | | | | 36) THE EXIT FROM THE SOUTHEAST EGRESS | | STAIR DOES NOT EXIT TO THE EXTERIOR OF | | THE BUILDING. FBC 406.2.5 DOES NOT ALLOW | | VECHICLE RAMPS TO SERVE AS AN EXIT | | ELEMENT. | | | | 37) PROVIDE A STAIR DETAIL SPECIFYING | | THE RISERS, TREADS, VERTICAL RISE | | BETWEEN LANDINGS, HEADROOM, HANDRAILS, | | GUARDS, STAIR WIDTH, ETC. PLEASE USE A | | LARGER SCALE THAN SHOWN ON A2O2 & A203. | | SEE FBC 1009. | | | | 38) NOTE: THE COMMON PATH OF TRAVEL IN | | THE FUTURE TENNANT SPACE IS ACCEPTABLE | | FOR A BUSSINESS OCCUPANCY, BUT MAY NOT | | BE FOR AN ASSEMBLY OCCUPANCY. THE COMMON | | PATH OF TRAVEL IS 20' FOR ASSEMBLY WITH | | MORE THAN 50 OCCUPANTS. | | | | 39) FBC 1008.1.2 REQUIRES EGRESS DOORS | | TO SWING IN THE DIRRECTION OF TRAVEL | | WHERE SERVING AN OCCUPANT LOAD OF 50 OR | | MORE PERSONS. EGRESS STAIRS DO NOT | | COMPLY. | | | | 40) THE EXIT TO THE EXTERIOR IS NOT | | SHOWN FOR THE NORTHWEST EGRESS STAIR. | | THE SITE PLAN ON A001 SHOWS EXTERIOR | | STAIRS AT THIS LOCATION. PROVIDE | | DETAILS. | | | | 41) THE DOOR SCHEDULE ON A400 LISTS ALL | | DOORS AS 3-0 X 8-0, THIS APPEARS TO | | DIFFER WITH THE EGRESS WIDTHS PROVIDED | | ON THE LIFE SAFETY PLAN AT THE TENNANT | | SPACE. FBC 1008.1.1 REQUIRES A MINIMUM | | CLEAR WIDTH OF NOT LESS THAN 32". | | | | 42) THE EXIT LIGHTS AT THE ELEVATOR AND | | DOOR 115 APPEAR TO BE LOCATED | | INCORRECTLY. THE EXIT LIGHT AT DOOR 116 | | IS LOCATED SO THAT IT WILL DIRECT PEOPLE | | BACK INTO THE GARAGE. PLEASE CORRECT. | | | | 43) SPECIFY GUARDS AND VECHICLE BARRIERS | | AS REQUIRED BY FBC 406.2.3 AND 406.2.4 | | AND DESIGNED IN ACCORDANCE WITH FBC | | 1607.7. PROVIDE DETAILS. | | | | 44) TO EXPEDITE REVIEW OF A RESUBMITTAL | | WHICH REQUIRES NEW PLANS IN ORDER TO | | ADDRESS THE ABOVE COMMENTS, THE OLD | | SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | REMAINING OLD SHEETS, TO FORM A SET OF | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | PLANS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-06-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-25 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-25 |
Time |
14:54 |
Sent To |
PC |
|
Notes |
2007-06-25 15:39:34 | ELEC REV OK, STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-04-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-22 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-22 |
Time |
08:44 |
Sent To |
|
|
Notes |
2007-04-22 09:06:12 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE 620.23, 620.24 FOR REQUIRED | | DEDICATED CIRCUITS. THESE MAY NOT FEED OTHER AREAS | | AND/OR EACH OTHER. | | | | 2) NOTE: PLEASE SEE REDLINED NOTES FROM 10/6/06 WHICH | | REQUIRED THE ATTACHMENT LOCATIONS TO BE SHOWN FOR | | TRANSFORMER. | | PLEASE SEE 250.20,250.30, 250.66. | | PLEASE KNOW THIS WAS REDLINED ON PLANS FOR ISSUANCE. | | | | ** PLEASE SEE POSSIBLE BUILDING REVIEW NOTES. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-06 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-06 |
Time |
11:48 |
Sent To |
|
|
Notes |
2006-10-06 00:00:00 | REDLINED 250.30, 250.20, AND 250.66 | | FOR THE GROUNDING ELECTRODE ATTACHMENT | | FOR THE TRANSFORMER. | | | | | | ALL THREE SETS OF ELECTRICAL PLANS | | STAMPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-06-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-18 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-18 |
Time |
13:49 |
Sent To |
|
|
Notes |
2006-06-18 00:00:00 | IN ELEC FOR REVIEW, REVIEW IN PROGRESS. | | ***** UNSAT 2ND REVIEW **** | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW AND SOME NEW DUE TO MANY ITEMS ON | | PLANS BEING COMPLETELY REVISED. | | | | ** PLEASE SEE THAT AN ADDRESS WAS | | ASSIGNED FOR PROJECT AND SHOULD BE | | REFLECTED IN TITLE BLOCKS OF ALL SHEETS. | | (1621 WORTHINGTON RD.) | | | | 1) NOTE: PLEASE SUBMIT ALL MANUFACTURE'S | | CUT/SPEC SHEETS FOR THE FOLLOWING. | | FUEL TANK, WP ENCLOSURE FOR GEN. | | THE GEN AND ATS SPCES WERE SUBMITTED AND | | ARE OK. | | PLEASE HOWEVER "HIGHLIGHT" THE GEN AS | | INDICATED ON PLANS ON THE SPEC SHEETS. | | | | ** ON PREVIOUS REVIEW** | | | | 2) NOTE: PLEASE SUBMIT PHOTO-METRICS | | UNDER NORMAL AND EM CONDITIONS FOR ALL | | EGRESS AREAS. THE NORMAL WERE SUBMITTED, | | HOWEVER COULD NOT LOCATE EM LEVELS. | | MIN 1FT CANDLE. NFPA -101 7.8.1.3 , | | 7.9.2.2. | | | | ** PREVIOUS REVIEW** | | | | 3) NOTE: PLEASE SEE FXTURE TYPES ON E0.1 | | DO NOT CORRELATE WIHT MANY FIXTURES IN | | GARAGE AND STAIRS. | | STILL NEED TO VERIFY TYPE OF FIXTURE FOR | | STAIRS. | | 215.5 | | | | 4) NOTE: PLEASE INDICATE THE OCP ON THE | | GENERATOR FOR EACH BREAKER THAT IS BEING | | INDICATED ON RISER. | | PLEASE INDICATE THE INTENDED LOAD(S). | | (IT IS NOTED THAT THE LOAD ON GGDP IS | | BEING SHOWN, HOWEVER RISER ALSO SHOWS | | GEN FEEDING OTHER LOADS? | | 215.5,220,702.5 ETC. | | | | ** PREVIOUS REVIEW NOTE** | | | | 5) NOTE: PLEASE SEE CALCULATIONS FOR FBC | | CHAPTER 13 ARE NEEDED PER 13-415.1.AB.1, | | 13-415.2.ABC.1. | | PLEASE PROVIDE WITH ENERGY CALCS. | | PLEASE SEE ENGERY CALCSMUST BE SIGNED, | | DATED AND SEALED BY THE RESPONSIBLE | | DESIGNER OF RECORD. | | PLEASE SEE CALCS SUBMITTED FOR GYM SPACE | | WERE NOT SIGNED/SEALED. | | ** PLEASE SEE NEW "ST" DEVICES LOCATED | | IN ROOMS DO NOT INDICATE THE MAX TIMED | | FOR "ON". | | PLEASE SEE THIS CAN/SHOULD ALSO BE | | LOCATED ON ELECTRICAL LEGEND. | | | | ** PREVIOUS NOTES** | | | | 6) NOTE: PLEASE SEE LOADS WERE SHOWN AS | | "BLANK" ON PREVIOUS PLANS. PLEASE SEE | | LOADS ARE NOW SHOWN, HOWEVER CONTINUOUS | | LOADS WHICH ARE REQUIRED TO BE SHOWN | | @125% DO NOT INDICATE THIS? | | PLEASE ALSO SEE ANY LARGEST MOTORS SHALL | | ALSO INDICATE 125%. | | PLEASE CLARIFY LOADS WHICH ARE BEING | | SHOWN ON "GMDP" FOR "GLH/GL1" AS BOTH | | PANELS ARE SHOWN WITHOUT ANY LOADS. | | WHERE IS THE 20KV COMING FROM? | | 215.5, 230.42,215.3 220 | | | | 7) NOTE: PLEASE SEE "GGDP" SHALL | | INDICATE A SIGN AS EM MAIN. | | PLEASE SEE 702.7 FOR SIGNALS REQUIRED. | | 702.8,701.8,701.9, 230.2E | | | | ** FOLLOW NOTES DO NOT APPLY TO KAMM | | CONSULTING ENG'S. | | | | 8) NOTE: PLEASE SEE "S" SHEETS ARE BIENG | | SEAL WHICH IS NO LONGER ACCEPTABLE UNDER | | FAC 61G15-23.001. | | PLEASE KNOW, IN FEB 04, A RULING BY THE | | FLORIDA BOARD OF PROFESSIONAL ENGINEER'S | | FOR A CHANGE IN THE WORDING IN THE SEAL. | | PLEASE KNOW, THE WORDING OF | | "CERTIFICATE" COULD NO LONGER BE USED | | AND THE NEW WORDING OF "LICENSE" WAS | | REQUIRED IN SAID SEAL. | | PLEASE KNOW THAT AN EXTENSION WAS | | GRANTED TODEC 31ST, 2005 , HOWEVER ALL | | PLANS AFTER SUCH DATE SHALL CONTAIN THE | | NEW SEAL WITH THE WORDING OF "LICENSE". | | THIS MAY ALSO BE IN BUILDING REVIEW | | COMMENTS. | | | | 9) NOTE: PLEASE SEE LANDSCAPE PLANS ARE | | STILL INDICATING ELECTRICAL LIGHTING | | ETC. | | PLEASE KNOW, ALL ELECTRICAL LIGHTING | | SHALL BE REMOVED FROM SAID PLANS, OR | | REVISE ELECTRICAL PLANS TO INCLUDE | | THESE. | | PLEASE ALSO SEE FBC CHAPTER 13 FOR | | OUTSIDE LANDSCAPE LT-ING. | | | | 10) NOTE: PLEASE SEE MISSING REQUIRED | | INFORMATION IN TITLE BLOCK FOR LANDSCAPE | | ARCHITECT AND FIRM. | | PLEASE SEE 61G1-16.004, FS 481.219 | | MISSING CERTIFICATE OF AUTHORIZATION #. | | | | 11) NOTE: PLEASE SEE FS 553.80(2)(B) | | WITH RESPECT TO ANY REPEAT COMMENTS. | | THIS IS ONLY A NOTICE. | | | | ** PLEASE ONLY SUBMIT ONE COPY OF | | OLD/VOIDED SETS FOR REVIEW AND | | REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | ** NOTE ADDED TO FRONT SCREEN. | | NOTICE OF COMMENCMENT IN PACKAGE HAS | | EXPIRED PER FS 713.13(2). | | WILL NEED A NEW RE-RECORDED NOC BEFORE | | PICKING UP PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-02-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-01 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-31 |
Time |
21:05 |
Sent To |
|
|
Notes |
2006-02-10 00:00:00 | *** PLEASE SEE NOTES UNDER MAIN BLDG | | ALSO FOR ADDRESS. | | | | PLEASE KNOW, THE LEGAL PROPERTY MAY NOT | | CHANGE AS THE ELECTRICAL SERVICEAND | | GENERATORS COME FROM GARAGE BLDG TO MAIN | | BLDG. | | PLEASE SEE ANY LEGAL PROPPERTY PCN | | CHNAGE ETC WILL REQUIRE LEGAL EASEMENTS | | ETC. | 2006-02-01 00:00:00 | ********** UNSAT ********** | | | | ** PLEASE KNOW, PLANS AND SUBMITTIALS | | ARE NOT COMPLETE AT THIS TIME. | | | | | | 1)NOTE: PLEASE SEE ALL CURRENT CODES | | SHALL BE REFERENCED TO THE CURRENT CODES | | IN EFFECT. PLEASE SEE PLANS CALL FOR | | 2001 FLORIDA BUILDING CODE. PLEASE KNOW, | | AS OF OCT 1ST, 2005 THE NEW FBC IS THE | | 2004 EDITION. PLEASE SEE THE FOLLOWING | | SHALL BE REFERENCED. 2003 NFPA-101, 2002 | | NFPA-70, AND 2002 NFPA-72 | | | | 2)NOTE: PLANS WILL REQUIRED BATTERY BACK | | UP LT FIXTURES IN MAIN ELECTRICAL RM, | | ELEVATOR RMS. | | PLEASE ALSO KNOW BATTERY BACK UP | | FIXTURES WILL BE REQUIRED IN STAIRWAY | | AND EGRESS PATHS TO PROVIDE A MIN OF 1FT | | CANDLE OF LIGHT BY SOME SORT OF BATTEY | | BACK UP FIXTURE. PLEASE SEE NFPA-101 | | 7.9.2.2, TRIPPING OR SHUTTING OFF ANY | | SINGLE DEVICE OR MEANS OF OVERCURRENT | | PROTECTION SHALL NOT LEAVE ANY ONE | | EGRESS PATH IN TOTAL DARKNESS. | | PLEASE PROVIDE PHOTOMETRICS FOR | | STAIRWAYS, AS THE 2003 LS 101 7.8.1.3 | | REQUIRES A MIN OF 10FY CANDLES(108LUX) | | IN STAIRWAYS UNDER NORMAL LIGHTING | | CONDITIONS AND 7.9.2.2 PERMITS THE | | DERATING TO A MIN OF 1FT CANDLE UNDER | | EMERGENCY CONDITIONS. | | 700.16.,700.12E ETC | | | | 3)NOTE: PLEASE SEE POSSIBLE BLDG | | COMMENTS AS STAIRWAY DOORS SEEM TO SWING | | IN, INSTEAD OF THE DIRECTION OF EGRESS. | | PLEASE SEE ANY POSSIBLE COMMENTS WITH | | RESPECT TO THE "FUTURE" TENANT SPACE. | | (GYM). | | | | 4)NOTE: PLEASE SUBMIT ALL MANUFACTURES | | SPECS/CUT SHEETS FOR GENERATOR, ATS, | | ETC. PLEASE PROVIDE SPECS FOR ANY TANKS | | FOR THE PRIME-MOVER OF GEN. | | PLEASE BE SURE ALL SPECS ETC INDICATE | | LISTINGS FROM A NRTL. | | NO REVIEW CAN BE DONE AT THIS TIME. | | | | 5)NOTE: PLEASE SEE NO MAIN IS SHOWN ON | | THE LINE-SIDE OF ATS SHOWN. PLEASE SEE | | THE FOLLOWING COMMENT WITH RESPECT TO | | GFP FOR SYSTEMS 277/480V 1000A'[S OR | | MORE. | | 230.70,ETC. | | | | 6)NOTE: PLEASE SEE ATS MANUFACTUREA S | | GFP IS REQUIED BY THE NEC FOR SERVICE | | AND MAY REQUIRE A 4-POLE ATS FOR GFP TO | | WORK CORRECTLY. | | PLEASE PROVIDE INFORMATION; PLEASE SEE | | GENERATOR IS ALREADY SHOWN AS A | | SEPARATELY DERIVED SYSTEM AS REQUIRED, | | HOWEVER NOT ENOUGH ATS INFORMATION IS | | SUBMITTED FOR CORRELATION OF REVIEW FOR | | CODE COMPLIANCE. | | EXAMPLE, PLEASE SEE TEXT TAKEN FROM | | ASCO: | | "WHERE GROUND FAULTPROTECTION IS | | TRIGGERED BY THE CODE AND AN ALTERNATE | | POWER SUPPLY IS INCLUDED,SWITCHING OF | | THE NEUTRAL BECOMES NECESSARY. THE | | CIRCUIT SHOWN ABOVE ILLUSTRATESSUCH A | | CIRCUMSTANCE. THE SERVICE IS LARGER THAN | | 1,000 AMPS. CONSEQUENTLY, GROUNDFAULT | | PROTECTION IS REQUIRED AT THE MAIN | | SERVICE DISCONNECT AT A MINIMUM. IF IT | | IS INSTALLED THERE AND THE GENERATOR | | NEUTRAL GROUNDING WAS THROUGH A SOLID | | CONNECTION TO THE MAIN SERVICE NEUTRAL, | | A GROUND FAULT WHEN THE GENERATOR IS | | FEEDING THE LOAD WILL CAUSE THE MAIN | | SERVICE DISCONNECT TO OPEN. THIS WILL | | NOTDISCONNECT THE ARCING FAULT FROM | | THE GENERATOR. COORDINATION IS THUS | | LOST." | | | | 7)NOTE: PLEASE SEE SERVICE MAINS AS | | REQUIRED DO NOT INDICATE ANY GFP PER | | 230.95,240.13 ETC. | | | | 8)NOTE: PLEASE LABEL ALL MAINS, 1, 2, 3 | | ETC, 1OF? 2 OF ? ETC. | | | | 9)NOTE: PLEASE PROVIDE ONE LINE | | GROUNDING ELECTRODE DIAGRAM FOR BLDG, TO | | INCLUDE GROUNDING ELECTRODE RISER FOR | | ANY TRANSFORMERS. 250.30,250.58 | | | | 10)NOTE: PLEASE SEE PANELS , (MDP WHICH | | ARE NOT COMPLETE AT THIS TIME. PLEASE | | SEE SOME AREA OF PANELS WHERE XXX'S ARE | | SHOWN FOR REQUIRED INFORMATION. | | PLEASE SEE "GGP" WHERE BRANCH CIRCUIT | | INFORMATION APPEARS IN THE TITLE BLOCK | | OF SAID PANEL. | | PLEASE SEE OTHER PANELS WHERE ALL | | INFORMATION INDICATED IS SHOWN AS | | "SPARE"? PLEASE SPECIFY "FUTURE" USE AND | | FOR WHAT LOADS THESE WILL FEED. | | | | 11)NOTE: PLEASE CORRELATE RISER DIAGRAM | | AND PANELS. | | PLEASE SEE "GLH", "GMDP", GLH", ETC, | | THESE ARE SHOWN BEING FED FROM OTHER | | EQUIPMENT ON RISER THAN LISTED ON PANEL | | SCHEDULES. | | PLEASE ALSO SEE "GDP", "GGP", AND "GLP", | | PLEASE SEE RISER, PLEASE SEE "T1B" AS | | THIS IS FED FROM TWO SEPARATE PANELS, | | AND CORRELATE WIRTH RISER. | | 215.5 | | | | 12)NOTE: PLEASE SEE NOTES FOR | | DISTRIBUTION SYSTEM MENTIONS TO EXTEND | | TO MAIN BLDG, PLEASE SEE NOTES FROM MAIN | | BLDG REVIEW WHEN COMPLETED AS THIS MAY | | AFFECT ELECTRICAL SERVICE OR DESIGN AS | | SHOWN. | | | | 13)NOTE: PLEASE COMPLETE ALL SERVICE | | ENTRANCE CONDUCTORS ON RISER ALONG WITH | | ALL FEEDERS. | | PLEASE SEE MISSING SEC'S TO EM SYSTEM, | | ATS OR NEW MAIN DISCONNECT, PLEASE SEE | | MISSING FEEDERS FROPM GEN, PLEASE SEE | | MISSING SEC'S TO GMDP, ATS TO GDP ETC . | | PLEASE COMPLETE RISER. | | | | 14)NOTE: PLEASE SEE MISSING OVERCURRENT | | PROTECTION AT GENERATOR. PLEASE ALSO SEE | | MISSING LOAD CALCUALTIONS FOR INTENDED | | LOAD FOR GENERATOR. | | PLEASE ALSO SEE FOLLOWING COMMENT. | | | | 15)NOTE: PLEASE COMPLETE AND SUBMIT MIN | | LOAD CALCUALTIONS AS REQUIRED PER | | NEC.220 | | PLEASE SEE ALL MAIN DISTRIBUTIION | | SYSTEMS ARE SHOWING "BLANKS" FOR LOADS?? | | PLEASE BE SURE TO INDICATE ALL LOADS. NO | | REVIEW OF THESE CAN BE DOINE AT THIS | | TIME. | | 215.5 | | | | 16)NOTE: PLEASE SEE NOTES FOR GENERATORS | | AS INDICATED ON ELECTRICAL PLANS WHICH | | NOTES ALL GENERATOR CONDUITS PROCEEDING | | TO THE MAIN OFFICE BLDG?? | | PLEASE INDICATE WHERE GENFOR GARAGE IS | | LOCATED? | | PLEASE ALSO SEE COMMENTS FOR MAIN BLDG | | AS THESE NOTES INDICATE ALL THESE | | FEEDERS SHALL PROCEED TO THE FIRST FLR | | MAIN ELECTRICAL ROOM, HOWEVER THIS DOES | | NOT SEEM TO CORRELATE WITH WHAT IS SHOWN | | ON MAIN BLDG PLANS. | | 215.5 | | | | 17)NOTE: PLEASE SEE FBC 2004 CHAPTER 13, | | 13-413.1ABC.1.1, .2 FOR VOLTAGE DROP | | INFORMATION NEEDED. | | | | 18)NOTE: PELASE SEE LIGHTING | | REQUIREMENTS UNDER 13-415 FOR AREAS OF | | CONTROL AND TANDEM WIRING. | | PLEASE SPECIFY THIS INFORMATION ON | | PLANS. | | | | 19)NOTE: PLEASE SEE LANDSCAPE PLANS | | MENTIONS AND NOTES LIGHTING AND TO SEE | | ELECTRICAL PLANS FOR THESE, HOWEVER | | THESE ITEMS COULD NOT BE LOCATED ON | | ELECTRICAL PLANS. | | PLEASE SUBMIT WIND LOAD CALCUALTIONS FOR | | ALL SITE LIGHTING POLES TO MEET FBC 140 | | MPH. | | | | 20)NOTE: PLEASE SEE LANDSCAPE PLANS ARE | | SEALED "PHOTO-COPIES" OF ARCHITECT'S | | SIGNATURE. PLEASE SEE FS 481.221 WHICH | | REQUIRES THE SIGNATURE TO BE AN ORIGINAL | | SIGNATURE. | | | | ** PLEASE KNOW, REVIEW FOR MAIN BLDG HAS | | NOT COMMENCED AT THIS TIME. | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER REVIEWER(S) WHICH MAY AFFECT | | ELECTRICAL PLANS. | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | AND ON.Y INSERT NEW REVISED SHEETS INTO | | COMPLETED SETS FOR REVIEW AND STAMPING. | | ONLY SUBMIT ONE COPY OF OLD/VOIDED | | SHEETS FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | DPALMER2WPB.ORG | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-11-02 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-11-02 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2006-10-06 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-10-06 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-10-06 |
Time |
13:12 |
Sent To |
|
|
Notes |
2006-10-06 00:00:00 | | | FOUND INCONSISTENCY IN LEGEND, FOR | | EXAMPLE, CIVIL SH 2 OF 5,IN LEGEND, | | PROPOSED STORM SEWER & CATCH BASIN HAS | | SQUARE SYMBOL AND ON DRAWING 142 FT 15" | | RCP HAS ROUND SYMBOL ON NORTH END, IS | | THIS AN INLET? ALSO IT SAYS 10.0 N.S. IS | | IT NORTH INVERT ELE? WHY TWO ELEVATIONS, | | 10.0 N. S. WE SEE ONLY ONE END OF PIPE. | | PLEASE MAKE CORRECTION IN ALL SHEETS. | | | | YOU NEED TO SHOW DUMPSTER ENCLOSURE | | DETAILS AND DIMENTIONS PER CITY OF WPB | | STANDARDS | | | | PLEASE SHOW DETAILS ON DRAWINGS PER CITY | | OF WPB STANDARDS FOR SIDEWALK,DRIVEWAY, | | APPROACH,PARKINGS,HANDICAP PARKING PER | | ADA, ETC., | | | | PLEASE RESPOND EACH ITEM SEPARATELY ON | | YOUR RESPONSE TO EXPEDITE THE PERMIT. | | | | RASIK CHOKSHI 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2006-07-21 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-07-21 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-07-21 |
Time |
16:24 |
Sent To |
|
|
Notes |
2006-07-21 00:00:00 | PLEASE PROVIDE DRAINAGE CALCULATIONS, & | | PLAN. HOW CISTERN TANKS ARE CONNECTED TO | | ANY OTHER SYSTEMS? DESIGN PARA FOR THAT | | SYSTEM TOO. | | PLEASE CORRECT THE WORD " TURBIDITY" IN | | POLLUTION PRE. NOTES D. | | | | RASIK, 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2006-02-24 |
Time |
09:23 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2006-02-24 |
Time |
09:23 |
Sent To |
|
|
Notes |
2006-02-24 00:00:00 | FAILED: | | | | 1. PLEASE PROVIDE A COPY OF MDIFIED | | SFWMD. | | 2. SHEET 2 OF 4, SEWER CONNECTION FOR | | THE PROPOSED BUILDING IS NOT CLEAR. | | 3. POLLUTION PREVENTION PLANS MUST BE | | ADDED TO CIVIL PLANS, PLEASE REVISE. | | 4. PLEASE SUBMIT CALCULATION FOR | | PERVIOUS, IMPERVIOUS AND BUILDING AREA | | FOR THIS IMPROVEMENT. | | 5. SHEET 2 OF 4, CISTERN TANKS, ARE THEY | | CONNECTED TO ANY SYS., AND THE INTEND? | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-06-22 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-06-22 |
Time |
12:51 |
Sent To |
|
|
Notes |
2007-06-22 13:12:24 | *****REVISION APPROVED***** | | | | | | THE COMMENTS OF 05/25/07 PLAN REVIEW HAVE BEEN | | ADDRESSED;PLAN SHEETSA2.1.1 THRUA2.3.3 WERE | | STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2007-06-12 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2007-06-12 |
Time |
15:02 |
Sent To |
|
|
Notes |
2007-06-12 15:03:12 | BOLLARDS ADDED TO PARKING AREA PER J. SMITH. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
F |
Date |
2007-05-25 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2007-05-25 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2007-05-25 |
Time |
10:23 |
Sent To |
|
|
Notes |
2007-05-25 10:28:46 | ***DENIED*** | | | | 1) PLEASE SEE BUILDING COMMENTS #1&2 REGARDING | | REQUIREMENTS PER FS AND FAC. | | | | 2) PLEASE PROVIDE MORE INFORMATION REGARDING PIPE | | RAILINGS. | | | | 3) EXIT DOORS TO MEET THE REQUIREMENTS OF NFPA 101, | | CHAPTER 7. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLANS REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-10-23 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-10-23 |
Time |
12:56 |
Sent To |
|
|
Notes |
2006-10-23 13:00:15 | ***APPROVED*** | | | | 1) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | ALARM AND STANDPIPE SYSTEMS. | | | | 2) TEMPORARY STANDPIPES REQUIRED WHEN BUILDING REACHES | | (3) STORIES OR (30') IN HEIGHT. | | | | 3) FIRE DEPARTMENT VALVES ON STANDPIPES TO BE 2 1/2"- 1 | | 1/2" REDUCER WITH CHAINS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2006-07-17 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2006-07-17 |
Time |
14:05 |
Sent To |
|
|
Notes |
2006-07-17 00:00:00 | 1. LIFE SAFETY PLAN FOR THE FIRST LEVEL | | AND THE ELECTRICAL PLANS FOR THE FIRST | | LEVEL DO NOT CORRESPOND WITH EACH OTHER. | | | | DOOR ALSO APPEARS TO BE MISSING FROM | | STAIR # 3 ON THE ELECTRICAL FIRST FLOOR | | LEVEL. | | | | 2. DOOR SWING IS INCORRECT ON PAGE | | A2.02. | | | | 3. SEVERAL N/A RESPONSES ARE PRESENT ON | | THE COMMENT SHEET FROM KAMM CONSULTING. | | PLEASE PROVIDE MORE DETAILS TO FIRE | | RESCUE COMMENTS. | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | OFFICER | | 804-4709 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-03-10 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-03-10 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-03-10 |
Time |
13:39 |
Sent To |
|
|
Notes |
2006-03-10 00:00:00 | ******DENIED****** | | | | 1) KNOX BOX LOCKING CAPS ARE REQUIRED | | FOR FIRE DEPARTMENT CONNECTION. | | | | 2) FIRE DEPARTMENT CONNECTION TO BE | | LOCATED NO FURTHER THAN 150' FROM A FIRE | | HYDRANT. | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM SYSTEMS. | | | | 4) 2A-10B,C RATED FIRE EXTINGUISHERS TO | | BE MOUNTED AT DISTANCE NOT TO EXCEED | | 75'. | | | | 5) PARKING GARAGE TO COMPLY WITH | | APPLICABLE BUILDING CODES AND NFPA 88A. | | | | 6) WILL PROPOSED TENANT SPACE MEET | | SEPARATION REQUIREMENTS? | | | | 7) PLEASE PROVIDE CLARIFICATION ON HOW | | AND WHERE PERSONS WILL BE EXITING THE | | BUILDING. | | | | 8) THE STAIRWELL DOOR SWINGS ON UPPER | | FLOORS APPEAR TO SWING AGAINST DIRECTION | | OF TRAVEL. | | | | 9) PANIC DOORS ARE MENTIONED ON SHT | | A-400, HOWEVER THIS IS NOT ILLUSTRATED | | IN THE DOOR SCHEDULE. | | | | 10) THE COOLING TOWER TO COMPLY WITH | | NFPA 214. | | | | 11) FIRE ALARM SYSTEM SHALL BE UL LISTED | | FOR CENTRAL STATION SERVICE. | | | | 12) NO FIRE SPRINKLER LAY OUT HAS BEEN | | SUBMITTED WITH DRAWINGS. | | | | 13) DUCT SMOKE DETECTOR SHALL INITIATE A | | GENERAL FIRE ALARM IN ACCORDANCE WITH | | LOCAL REQUIREMENTS. | | | | 14) ARE SMOKE DETECTORS PLANNED FOR | | ELEVATOR RECALL? | | | | 15) IT WOULD APPEAR THAT MORE | | AUDIBLE/VISUAL DEVICES ARE NEEDED ON | | UPPER FLOORS. | | | | 16) EXIT LIGHTS TO BE MOUNTED AT | | DISTANCES NOT TO EXCEED 100'. | | | | 17) PLEASE EXPLAIN WHY EXIT SIGNS DIRECT | | PERSONS INTO STAIWELLS ON FLOOR #1. | | | | 18) PLEASE PROVIDE MANUFACTURER SPEC | | SHEETS FOR GENERATOR. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLANS REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
18 |
Status |
N |
Date |
2007-06-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-24 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-24 |
Time |
16:35 |
Sent To |
E |
|
Notes |
2007-06-24 16:35:25 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
17 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-04 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-04 |
Time |
08:44 |
Sent To |
|
|
Notes |
2007-06-14 20:30:29 | | | | | SENT TO R. MCDOUGAL FOR REVIEW.MAY NOT NEED FIRE | | REVIEW. | 2007-06-04 08:44:27 | WAITING FOR "COMM" BD-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
16 |
Status |
N |
Date |
2007-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-01 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-01 |
Time |
16:56 |
Sent To |
|
|
Notes |
2007-05-10 08:50:40 | TO "COMM" BD#36 | 2007-05-01 16:57:13 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
15 |
Status |
N |
Date |
2007-04-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-18 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-18 |
Time |
13:33 |
Sent To |
|
|
Notes |
2007-04-18 13:34:04 | TO "COMM" BD#47 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-29 |
Time |
09:05 |
Sent To |
B |
|
Notes |
2007-03-29 09:05:41 | TO RMCD'S DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
13:23 |
Sent To |
B |
|
Notes |
2007-03-06 13:23:31 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-28 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-28 |
Time |
10:22 |
Sent To |
B |
|
Notes |
2007-02-28 10:23:00 | TO "RMCDOUGAL" DESK/3 SUBMITTALS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-27 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-27 |
Time |
18:04 |
Sent To |
B |
|
Notes |
2007-02-27 18:05:10 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-20 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-20 |
Time |
15:14 |
Sent To |
B |
|
Notes |
2007-02-20 15:14:46 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-12 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-12 |
Time |
15:26 |
Sent To |
B |
|
Notes |
2007-02-12 15:26:55 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-08 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-08 |
Time |
12:19 |
Sent To |
Z |
|
Notes |
2007-02-08 12:19:37 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-08 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-08 |
Time |
11:49 |
Sent To |
P |
|
Notes |
2007-02-08 11:49:35 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-09 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-09 |
Time |
17:46 |
Sent To |
P |
|
Notes |
2007-01-09 17:46:43 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-10-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-31 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-31 |
Time |
11:37 |
Sent To |
ENG |
|
Notes |
2006-10-31 11:37:28 | TO "RCHOKSHI" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-21 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-21 |
Time |
11:05 |
Sent To |
|
|
Notes |
2006-10-05 00:00:00 | TO "COMM" BD#19/PLANS ON RACK | 2006-09-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-26 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-26 |
Time |
17:03 |
Sent To |
|
|
Notes |
2006-06-15 00:00:00 | ON COMM BOARD #14, 3-SETS OF PLANS ON | | COMM RACK. | 2006-05-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-05-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-19 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-19 |
Time |
15:12 |
Sent To |
B |
|
Notes |
2006-05-19 00:00:00 | TO "RMCDOUGAL DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-04-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-04-18 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-12-22 |
Time |
16:29 |
Sent To |
|
|
Notes |
2006-01-31 00:00:00 | TO "COMM" BD#39 | 2005-12-22 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-10-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-10-13 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-10-13 |
Time |
14:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-07-28 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-07-28 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-07-28 |
Time |
14:39 |
Sent To |
|
|
Notes |
2006-07-28 00:00:00 | DENIED:2004 FMC | | RESPONSE TO COMMENTS DATED 2-21-06: | | | | COMMENT 1:OK | | COMMENT 2:OK | | | | 3.RESPONSE INDICATES ELEVATION HAS | | BEEN PROVIDED FOR ALL INTAKE & RELIEF | | LOUVERS.PLEASE NOTE, COMMENT REQUESTED | | THE ELEVATION BE PROVIDED FOR THE | | TERMINATION OF EF-1.TERMINATION TO | | EF-1 IS TO THE INTERIOR OF THE PARKING | | GARAGE & APPEARS TO BE DISCHARGING ONTO | | WALKWAY.SHOW COMPLIANCE WITH 2004 FMC | | 401.5.2 & 501.2. | | | | COMMENT 4:OK | | | | ***************NEW COMMENT************* | | | | 5.PLEASE INDICATE WHAT WILL BE IN | | STORAGE AREA.PLEASE NOTE THE | | TERMINATION OF EXHAUST FROM EF-2, 3, 4, | | 5, & 6 ALL TEMRINATE WITHIN 10 FT OF THE | | DOOR.PLEASE CLARIFY. | | | | PLEASE PROVIDE ADDITIONAL INFORMAITON | | FOR THE EMERGENCY GENERATOR. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-02-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-02-21 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-02-21 |
Time |
15:04 |
Sent To |
|
|
Notes |
2006-02-21 00:00:00 | DENIED:2004 FLORIDA BUILDING CODE | | | | 1.PER CITY AMENDMENTS TO THE 2004 | | FLORIDA BUILDING CODE 106.1.3, BUILDING | | PLANS SHALL BE DRAWN TO A MINIMUM OF 1/8 | | INCH SCALE.PLANS INDICATE 3/32. | | | | 2.PLAN SHEET M2.1 INDICATES EXHAUST | | FROM THE ELEVATOR EQUIPMENT ROOM BUT | | DOES NOT INDICATE MAKE-UP AIR.PLEASE | | SHOW COMPLIANCE WITH 2004 FMC 403.1. | | | | 3.PLEASE PROVIDE ELEVATION OF THE | | DISCHARGE FROM EF-1.PLEASE NOTE, | | EXHAUST SHALL TERMINATE AS TO NOT CREATE | | A NUISANCE. | | | | 4.PLEASE INDICATE MEANS OF VENTILATION | | INTO ALL THE MECHANICAL ROOM AREAS. | | SHOW COMPLIANCE WITH 2004 FMC 401.2 & | | 401.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2007-03-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-05 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-05 |
Time |
14:37 |
Sent To |
|
|
Notes |
2007-03-05 14:38:49 | REVISION OK - SHEETS P0.1, P2.4, P2.5, P2.6, & P5.2. | | --ADDED TRENCH DRAINS AT STAIRS AND RELATED STORM | | PIPING. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-22 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-22 |
Time |
15:57 |
Sent To |
|
|
Notes |
2007-01-22 15:58:31 | REVISION OK - SHTS P3.4 & P6.2 DELETED HOSE BIBBS & | | WATER LINE SUPPLY FOR HOSE BIBBS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-10-26 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-10-26 |
Time |
13:33 |
Sent To |
|
|
Notes |
2006-10-26 13:34:40 | RE-SUB | | NOTES FROM 7-8-06 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-07-08 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-07-08 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-07-08 |
Time |
09:27 |
Sent To |
|
|
Notes |
2006-07-08 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC 2004 PLUMBING CODE PLAN REVIEW | | FBC2004 FUEL GAS CODEPLAN REVIEW | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | DENIED | | 1) SHT P6.2 WATER RISER HOSE BIBBS | | SEC 606.2 LOCATION OF SHUTOFF VALVES. | | SHUTOFF VALVES SHALL BE INSTALLED IN THE | | FOLLOWING LOCATIONS: | | 2. ON THE WATER SUPPLY PIPE TO EACH | | SILLCOCK IN OTHER THAN ONE- AND | | TWO-FAMILY RESIDENTIAL OCCUPANCIES. | | | | 2) SHT P6.2 SEC 608.15.4.2 | | HOSE CONNECTIONS. | | SILLCOCKS, HOSE BIBBS, WALL HYDRANTS AND | | OTHER OPENINGS WITH A HOSE CONNECTION | | SHALL BE PROTECTED BY AN | | ATMOSPHERIC-TYPE OR PRESSURE-TYPE VACUUM | | BREAKER OR A PERMANENTLY ATTACHED HOSE | | CONNECTION VACUUM BREAER. | | | | 3)PLUMBING RESPONSE:DATED MAY 19, 2006 | | REFERENCE TO SHEET P7.2 DEPICTS A | | CISTERN PIPING DIAGRAM. | | NOT INCLUDE WITH THIS SET OF PLANS. | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT PLUMBING | | PLANS. | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-03-04 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-03-04 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-03-04 |
Time |
14:46 |
Sent To |
|
|
Notes |
2006-03-04 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC 2004 PLUMBING CODE PLAN REVIEW | | FBC2004 FUEL GAS CODEPLAN REVIEW | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | FBC FLORIDA BUILDING CODE 2001 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2001 | | | | DENIED | | 1) DISCRIPTION OF WORK ON PERMIT | | APPLICATION, MULTI STORY PARKING GARAGE. | | SHT. P2.4,P3.4, P6.2,P7.2PLEASE SHOW | | CLEARLY HOW THIS IS RELATED TO THE | | PARKING GARAGE CONSTRUCTION. | | 106.1.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE | | MATERIAL. ELECTRONIC MEDIA DOUCMENTS ARE | | PERMITTED TO BE SUBMITTED WHEN APPROVED | | BY THE BUILDING OFFICAL. CONSTRUCTION | | DOUCMENTS SHALL BE OF SUFFICENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN | | DETAIL THAT ITWILL CONFORM TOTHE | | PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS | | AS DETERMINED BY THE BUILDING OFFICAL ( | | SEE ALSO SECTION 106.3.5) | | | | 2) SHT L-1 REFERENCES IRRIGATION. | | PLEASE PROVIDE IRRIGATIONS PLANS. | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT PLUMBING | | PLANS. | | END OF COMMENTS, QUESTIONS 561-805-6692 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
8 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-06-22 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-06-22 |
Time |
08:08 |
Sent To |
B |
|
Notes |
2007-06-22 08:10:05 | ***PROVISO*** | | | | ALL SPACES LABELED AS COMPACT ON THE PLANS SHALL BE | | SIGNED AS SUCH IN THE FIELD. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-05-15 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-05-15 |
Time |
08:08 |
Sent To |
|
|
Notes |
2007-05-15 11:30:25 | ***FAILED*** | | | | IT APPEARS THAT REVISIONS WERE MADE TO THE PARKING | | STRIPING AND CONFIGURATION SINCE LAST APPROVED BY | | ZONING.THE SPACE IN THE FAR SOUTHEAST CORNER OF THE | | MID AND UPPER LEVELS SHOULD BE DESIGNATED COMPACT AS IT | | IS LESS THAN 8 FEET 6 INCHES WIDE.IN ORDER TO VERIFY | | THAT THE PARKING COUNTS ARE STILL ACCURATE, DESPITE | | THESE CHANGES, PLEASE PROVIDE A COPY OF THE SHEET THAT | | ACCURATELY SHOWS THE PARKING DISTRIBUTION (REQUIRED VS. | | PROVIDED, HANDICAP REQUIRED VS. PROVIDED, COMPACT | | PROVIDED, ETC.). | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-04-30 |
Time |
23:16 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-04-30 |
Time |
23:16 |
Sent To |
|
|
Notes |
2007-04-30 23:19:18 | ***FAILED*** | | | | IT APPEARS THAT REVISIONS WERE MADE TO THE PARKING | | STRIPING AND CONFIGURATION SINCE LAST APPROVED BY | | ZONING.THE SPACE IN THE FAR SOUTHEAST CORNER OF THE | | MID AND UPPER LEVELS SHOULD BE DESIGNATED COMPACT AS IT | | IS LESS THAN 8 FEET 6 INCHES WIDE.IN ORDER TO VERIFY | | THAT THE PARKING COUNTS ARE STILL ACCURATE, DESPITE | | THESE CHANGES, PLEASE PROVIDE A COPY OF THE SHEET THAT | | ACCURATELY SHOWS THE PARKING DISTRIBUTION (REQUIRED VS. | | PROVIDED, HANDICAP REQUIRED VS. PROVIDED, COMPACT | | PROVIDED, ETC.). | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2007-02-15 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-02-15 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-02-15 |
Time |
13:33 |
Sent To |
|
|
Notes |
2007-02-15 13:33:46 | ***LANDSCAPE REVISION PASSED*** |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-10-31 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-10-31 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2006-10-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-10-25 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-10-25 |
Time |
10:46 |
Sent To |
|
|
Notes |
2006-10-25 11:00:31 | ***FAILED*** | | | | 1)DETAIL 2 ON SHEET A1.1.0 FOR THE SCREEN WALL SHOWS | | 8 FEET IN HEIGHT.THE SITE PLANS ON SHEETS A1.1.0 AND | | A1.1.1 INDICATE 6 FEET.PLEASE MAKE CONSISTENT. | | | | 2) NUMBER OF PARKING SPACES INDICATED IS INCORRECT. | | THE FOLLOWING WAS DRAWN ON THE FLOOR PLANS...PLEASE | | ADJUST ALL PARKING COUNTS ACCORDINGLY: | | | | 1ST LEVEL - 91 (TOTAL) - 44 (REGULAR) - 43 (COMPACT) - | | 4 (ACCESSIBLE)***2 SPACES ON THE NORTH END ARE SHOWN | | AS REGULAR SPACES, HOWEVER, NEED TO BE DESIGNATED AS | | COMPACT*** | | | | 2ND THRU 4TH LEVEL - 107 (TOTAL) - 64 (REGULAR) - 41 | | (COMPACT) - 2 (ACCESSIBLE)***2 SPACES ON THE NORTH | | END ARE SHOWN AS REGULAR SPACES, HOWEVER, NEED TO BE | | DESIGNATED AS COMPACT*** | | | | 5TH LEVEL - 88 (TOTAL) - 56 (REGULAR) - 30 (COMPACT) - | | 2 (ACCESSIBLE)***5 SPACES ON THE NORTH END ARE SHOWN | | AS REGULAR SPACES, HOWEVER, NEED TO BE DESIGNATED AS | | COMPACT*** | | | | 3)XERISCAPE TABLE, WITH A MINIMUM OF 30 POINTS, SHALL | | BE PROVIDED ON THE LANDSCAPE PLANS...IT WAS REMOVED | | UPON SUBMISSION OF REVISED PLANS. | | | | 4) SIGNAGE SHALL BE PROVIDED AT EACH COMPACT SPACE | | INDICATING SUCH.PLEASE MAKE A NOTE AND/OR ADD A | | DETAIL. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-07-09 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-07-09 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-07-09 |
Time |
14:46 |
Sent To |
|
|
Notes |
2006-07-09 00:00:00 | 7/9/06 ***FAILED*** | | | | 1) THE NORTH WALL ON THE SITE PLANS | | APPEARS TO BE IN THE INCORRECT | | LOCATION...IT IMPEDES WITH THE WALKING | | PATH, NORTHWEST STAIRS, ETC. | | | | 2) PROVIDE DETAILS REGARDING THE | | CHILLER/COOLING TOWERS.WHY ARE THESE | | NOW BEING PLACED AT GRADE?DETAILS, | | SUCH AS HEIGHT, NEED TO BE PROVIDED AS | | WELL AS SUFFICIENT SCREENING (I.E. SOLID | | WALL OF ADEQUATE HEIGHT WITH | | SHRUBS/HEDGES). | | | | 3) PROVIDE DETAILS REGARDING THE | | PROPOSED GENERATOR, SUCH AS THE HEIGHT, | | TO ENSURE THAT THE PROPOSED 6 FOOT | | SCREEN WALL IS SUFFICIENT. | | | | 4) THE NUMBER OF PARKING SPACES | | INDICATED ON THE SITE PLAN DATA TABLE | | DOES NOT CORRESPOND WITH WHAT IS DRAWN | | ON THE FLOOR PLANS.THERE APPEARED TO | | BE 491 SPACES ON THE FLOOR PLANS (300 | | REGULAR, 179 COMPACT, AND 12 | | ACCESSIBLE). | | | | 5) PROVIDE AN ENLARGEMENT OF THE DOUBLE | | STRIPING FOR THE PARKING SPACES.THE | | DETAIL PROVIDED APPEARS INCORRECT. | | THERE SHOULD BE 1 FOOT 4 INCHES FROM THE | | CL OF THE STRIPE TO THE CL OF THE STRIPE | | WITH 12 INCHES FROM INSIDE OF THE STRIPE | | TO INSIDE OF THE STRIPE.REFER TO | | SECTION 94-485 OF THE CITY OF WEST PALM | | BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS FOR AN EXAMPLE.THE | | HANDICAP STRIPING IS INCORRECT IN REGARD | | TO THIS AS WELL. | | | | 6) PROVIDE A STRIPING DETAIL THAT SHOWS | | HOW THE SUPPORT COLUMNS RELATE TO THE | | PROPOSED STRIPING.WHAT ARE THE | | DIMENSIONS OF THE COLUMNS?WHERE DO | | THEY FALL IN THE STRIPING?ETC. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | SENIOR PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-02-21 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-02-21 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-02-21 |
Time |
09:11 |
Sent To |
|
|
Notes |
2006-02-21 00:00:00 | 2/21/2006 ***FAILED*** | | | | 1) ON THE SITE PLANS, PLEASE INDICATE | | THE LIMITS OF SITE IMPROVEMENTS | | ASSOCIATED WITH THIS PERMIT. | | | | 2) MORE DETAIL SHALL BE PROVIDED | | REGARDING THE COLUMNS THAT ARE LOCATED | | BETWEEN COMPACT SPACES ON THE FIRST | | FLOOR.PLEASE PROVIDE A DETAIL SHOWING | | HOW THE COLUMN RELATES TO THE STRIPING, | | ETC.IF THE COLUMN FALLS COMPLETELY | | WITHIN THE DOUBLE-STRIPE, THE SPACE MAY | | REMAIN.IF IT INTERFERES IN ANY WAY | | WITH THE STALL, THE SPACE SHALL BE | | REMOVED. | | | | 3) IF THE GENERATORS ARE NOT A PART OF | | THE PERMIT APPLICATION, REMOVE THEM FROM | | THE PLANS OR MAKE NOTE THAT THEY WILL BE | | SUBMITTED UNDER SEPARATE PERMIT.IF | | THEY ARE A PART OF THE PERMIT PACKAGE, | | APPROPRIATE SCREENING SHALL BE PROVIDED | | (WALL, HEDGE, ETC.). | | | | 4) LANDSCAPE PLANS SHALL BE SEALED WITH | | AN ORIGINAL SIGNATURE, NOT A COPY. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH | | AT (561) 822-1435. | | | | LANDSCAPE COMMENTS: | | | | 1) REFER TO SET #1, SHEET L-4 FOR | | COMMENTS REGARDING PLANTING | | DETAILS/DIAGRAMS. | | | | QUESTIONS/COMMENTS, CONTACT ALAN | | BARATTA, LANDSCAPE PLANNER AT (561) | | 822-1435. | | |
|
|