Plan Review Details - Permit 05120987
Plan Review Stops For Permit 05120987
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2006-10-20 Cont ID  
Sent By lursu Date 2006-10-20 Time 08:26 Rev Time 0.00
Received By lursu Date 2006-10-20 Time 08:26 Sent To  
Notes
2006-10-20 08:26:53THE SITE ADDRESS FOR THE MULTI-LEVEL PARKING GARAGE IS
 CORRECT TO BE 1621 WORTHINGTON RD

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2006-02-02 Cont ID  
Sent By lursu Date 2006-02-02 Time 13:30 Rev Time 0.00
Received By lursu Date 2006-02-02 Time 13:30 Sent To  
Notes
2006-02-02 00:00:00NEED SITE PLAN & PLAT BEFORE ISSUING THE
 CORRECT ADDRESS LU

Review Stop B BUILDING (STRUCTURAL)
Rev No 16 Status P Date 2007-06-22 Cont ID  
Sent By rmcdouga Date 2007-06-22 Time 14:17 Rev Time 0.00
Received By rmcdouga Date 2007-06-22 Time 14:17 Sent To  
Notes
2007-06-22 14:17:54PROCESSED AS BUILT REVISIONS TO ARCHITECTURAL SHEETS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 15 Status P Date 2007-06-18 Cont ID  
Sent By rmcdouga Date 2007-06-18 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2007-06-18 Time 13:38 Sent To  
Notes
2007-06-18 13:44:06ADDITIONAL CHANGES HAVE BEEN MADE TO THESE PAGES BY THE
 REVISION WHICH WAS SUBMITTED ON 5/31/07. SEE THE NOTES
 FOR REVISION # 14 .

Review Stop B BUILDING (STRUCTURAL)
Rev No 14 Status P Date 2007-06-18 Cont ID  
Sent By rmcdouga Date 2007-06-18 Time 13:03 Rev Time 0.00
Received By rmcdouga Date 2007-06-18 Time 13:03 Sent To Z
Notes
2007-06-18 13:07:28REVISIONS/AS BUILTS TO SHEETS A1.1.0, A2.1.1, A2.1.2,
 A2.1.3, A2.2.1, A2.2.2, A2.3.1, A2.3.2, AND A2.3.3 ARE
 OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 13 Status F Date 2007-05-02 Cont ID  
Sent By rmcdouga Date 2007-05-02 Time 13:01 Rev Time 0.00
Received By rmcdouga Date 2007-05-02 Time 12:05 Sent To  
Notes
2007-05-02 13:00:50AS BUILT REVISIONS DENIED BY BUILDING
  
 1) SUBMIT THREE (3) COMPLETE SETS OF DRAWINGS FOR
 REVIEW.FS 553.71
  
 2) SOME OF THE 8-1/2" X 11" SIGNED AND SEALED DRAWINGS
 FROM THE ENGINEER HAVE COPIED SIGNATURES WHICH IS NOT
 ALLOWED. SEE FAC 61G15-23.002 AND FS471.025
  
 3) SHOW COMPLIANCE WITH FBC 11-4.7.7 DETECTABLE
 WARNINGS.
 A CURB RAMP SHALL HAVE A DETECTABLE WARNING COMPLYING
 WITH SECTION 11-4.29.2 . THE DETECTABLE WARNING SHALL
 EXTEND THE FULL WIDTH AND DEPTH OF THE CURB RAMP.
  
 4) SHOW COMPLIANCE WITH FBC 11-4.5.4 GRATINGS.
 IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEN THEY
 SHALL HAVE SPACES NO GREATER THAN ? INCH (13 MM) WIDE
 IN ONE DIRECTION [SEE FIGURE 11-8 (G)]. IF GRATINGS
 HAVE ELONGATED OPENINGS, THEN THEY SHALL BE PLACED SO
 THAT THE LONG DIMENSION IS PERPENDICULAR TO THE
 DOMINANT DIRECTION OF TRAVEL [SEE FIGURE 11-8 (H)].
  
 5) SHOW COMPLIANCE WITH FBC 11-4.29.5 DETECTABLE
 WARNINGS AT HAZARDOUS VEHICULAR AREAS.
 IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE
 WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS,
 OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND
 VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL
 BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS
 36 INCHES (915 MM) WIDE, COMPLYING WITH SECTION
 11-4.29.2 .
  
 6) SHOW COMPLIANCE WITH FBC 11-4.1.2 FOR REQUIRED
 ACCESSIBLE PARKING SPACES. SEE ZONING COMMENTS.
  
 7) PROVIDE DETAIL OF PIPE RAIL SPECIFIED IN STAIR
 DETAILS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2007-03-30 Cont ID  
Sent By rmcdouga Date 2007-03-30 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2007-03-30 Time 12:44 Sent To  
Notes
2007-03-30 13:25:54SUBMITTAL OF SIGNED AND SEALED LIGHT POLE CALCULATIONS
 IS OK,

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2007-03-06 Cont ID  
Sent By rmcdouga Date 2007-03-06 Time 18:28 Rev Time 0.00
Received By rmcdouga Date 2007-03-06 Time 18:28 Sent To  
Notes
2007-03-06 18:27:48SUBMITTED SHOP DRAWINGS FOR EGRESS STAIRS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status F Date 2007-03-01 Cont ID  
Sent By rmcdouga Date 2007-03-01 Time 07:36 Rev Time 0.00
Received By rmcdouga Date 2007-03-01 Time 07:04 Sent To  
Notes
2007-03-01 07:36:34DENIED BY BUILDING
  
 1) THE EMBEDMENT POLE CALCULATIONS FROM PCSI ARE
 INCORRECT. THE CALCULATIONS THAT WERE USED ARE FROM FBC
 SECTION 1819.7.2.1 WHICH ONLY APPLIES TO THE HIGH
 VELOCITY HURRICANE ZONE. THE PROJECT IS LOCATED IN THE
 CITY OF WEST PALM BEACH, WHICH IS NOT LOCATED IN THE
 HVHZ.
  
 2) THE LATERAL SOIL BEARING PRESSURE THAT WAS USED IN
 THE CALCULATION WAS BASED ON SEDIMENTARY ROCK. THE
 SUBSURFACE SOIL REPORT FOR THE PROJECT FROM ARDAMAN AND
 ASSOCIATES, INC. INDICATES VERY LOOSE TO MODERATELY
 DENSE SANDS UNDERLYING THE SITE.
  
 3) THE EMBEDMENT DEPTH, HEIGHT ABOVE GROUND, MAXIMUM
 EPA, ETCON THE CUT SHEET ARE INCORRECT. SEE
 ATTACHED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2007-03-01 Cont ID  
Sent By rmcdouga Date 2007-03-01 Time 06:35 Rev Time 0.00
Received By rmcdouga Date 2007-03-01 Time 06:21 Sent To  
Notes
2007-03-01 06:35:37DENIED BY BUILDING
  
 1) ACCORDING TO THE TITLE BLOCK, THE SHOP DRAWINGS
 SUBMITTED FOR THE TILT WALL PANELS IS FROM JOEL R.
 MIDDLEBROOKS, THE ENGINEER OF RECORD FOR THE PROJECT
 AND NOT A SPECIALTY ENGINEER. HE SHOULD SIGN AND SEAL
 THE DRAWINGS AS REQUIRED BY FS 471. HE SHOULD NOT BE
 DOING A SHOP DRAWING REVIEW FOR GENERAL CONFORMANCE TO
 DESIGN ON HIS OWN DRAWINGS.
  
 2)THIS IS THE SECOND TIME THESE DRAWINGS HAVE BEEN
 SUBMITTED WITHOUT BEING SIGNED AND SEALED BY THE
 ENGINEER WHO PRODUCED THEM AND WHOSE NAME APPEARS IN
 THE TITLE BLOCK. THIS IS REQUIRED BY FLORIDA STATUTE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-02-28 Cont ID  
Sent By rmcdouga Date 2007-02-28 Time 17:55 Rev Time 0.00
Received By rmcdouga Date 2007-02-28 Time 17:55 Sent To  
Notes
2007-02-28 17:58:26WINDLOAD CALCULATIONS FOR LIGHT POLES ON TOP OF GARAGE
 AND CONCRETE BASE ANCHORING ENGINEERING IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-02-21 Cont ID  
Sent By rmcdouga Date 2007-02-21 Time 16:04 Rev Time 0.00
Received By rmcdouga Date 2007-02-21 Time 16:04 Sent To  
Notes
2007-02-21 16:05:243) THE EMBED SHOP DRAWINGS ARE OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2007-02-21 Cont ID  
Sent By rmcdouga Date 2007-02-21 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2007-02-21 Time 15:52 Sent To  
Notes
2007-02-21 16:04:18DENIED BY BUILDING
  
 1)THE PRECAST COLUMN AND DOUBLE T PLANS ARE DENIED
 BECAUSE ONE OF THE THREE REQUIRED SETS IS NOT SIGNED
 AND SEALED BY THE SPECIALITY ENGINEER WHOSE TITLE BOCK
 APPEARS ON THE DRAWINGS.
  
 2) THE TILT WALL PANEL PLANS ARE DENIED BECAUSE NONE OF
 THE THREE SETS HAVE BEEN SIGNED AND SEALED BY THE
 STRUCTURAL ENGINEER WHOSE TITLE BLOCK APPEARS ON THE
 DRAWINGS. FS 471.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2007-02-12 Cont ID  
Sent By rmcdouga Date 2007-02-12 Time 18:34 Rev Time 0.00
Received By rmcdouga Date 2007-02-12 Time 18:34 Sent To  
Notes
2007-02-12 18:46:38SUBMITTAL OF WIND LOAD CALCULATIONS FOR LIGHT POLES ON
 TOP OF PARKING GARAGE ARE DENIED.
  
 1) THREE SET OF SIGNED AND SEALED DRAWINGS ARE REQUIRED
 FOR THRESHOLD BUILDINGS.
  
 2)THE ENGINEERING IS REQUIRED TO BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE.
  
 3) SUBMIT A DETAIL SPECIFYING HOW THE CONCRETE BASE
 SHOWN IN THE HAPCO DRAWING WITH 36" ANCHOR BOLTS
 EMBEDDED ARE ATTACHED TO THE STRUCTURE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-11-01 Cont ID  
Sent By rmcdouga Date 2006-11-01 Time 15:04 Rev Time 0.00
Received By rmcdouga Date 2006-11-01 Time 15:04 Sent To  
Notes
2006-11-01 16:25:39BUILDING PROVISO
  
 IN ORDER TO ASSURE THAT THE FIRE SEPARATION DISTANCE
 REQUIRED BY FBC TABLE 704.8 FOOTNOTE (C) AND THE 20
 FEET DISTANCE TOOTHER STRUCTURES REQUIRED BY FBC
 903.6.1(2)ARE IN COMPLIANCE, THE AMENDMENT TO THE
 DECLARATION OF CONDOMINIUM, DECLARATION OF UNITY OF
 CONTROL AND DECLARATION OF RESTRICTIVE COVENANT MUST BE
 EXECUTED AND APPROVED BY THE BUILDING OFFICIAL BEFORE
 THE CERTIFICATE OF OCCUPANCY WILL BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-12 Cont ID  
Sent By rmcdouga Date 2006-10-12 Time 16:21 Rev Time 0.00
Received By rmcdouga Date 2006-10-12 Time 16:21 Sent To  
Notes
2006-10-12 16:46:34 
 DENIED BY BUILDING
  
 1)THE SURVEY AND SITE PLANS DO NOT LOCATE THE
 CONDO/PROPERTY LINES 20 FEET FROM THE PARKING STRUCTURE
 AS REQUIRED BY 2004 FBC 903.6.1(2). SEE COMMENT #4 FROM
 PREVIOUS REVIEW.
  
 2)THE LOCATION OF THE CONDO/PROPERTYLINES DO NOT
 APPEAR TO BEGREATER THAN 10 FEET AS REQUIRED BY FBC
 TABLE 708.4 FOOTNOTE (C) SUCH THAT THE AREA OF OPENINGS
 IS NOT LIMITED. SEE COMMENT #2 FROM PREVIOUS REVIEW.
  
 3)THE SQUARE FOOTAGE ANALYSIS ON A2.0.1 STILL LISTS
 BUSINESS AND STORAGE OCCUPANCIES ON THE FIRST FLOOR.
  
 4) SHEETS A3.2.2 AND A4.1.2 SPECIFY 3PLY MODIFIED ROOF
 COVERING. THE PRODUCT APPROVAL THAT WAS SUBMITTED IS
 FOR A BUILT UP ROOF SYSTEM. PLEASE CORRECT.
  
 5) DETAIL 2 ON A1.1.0 SPECIFIES AN 8' HIGH GENERATOR
 SCREEN WALL AND THE SITE PLANS ON A 1.1.0 AND A1.1.1
 SHOW THE WALL AS6'. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By rmcdouga Date 2006-07-05 Time 12:37 Rev Time 0.00
Received By rmcdouga Date 2006-07-05 Time 12:36 Sent To  
Notes
2006-07-05 00:00:00DENIED BY BUILDING
  
 1621 WORTHINGTON ROAD
 5 STORY PARKING GARAGE
 TYPE II-B (SPRINKLERED)(PER PLANS)
 MIXED OCCUPANCY (S-2 STORAGE & BUSINESS)
 FLOOD ZONE A9 BFE 13' (+ 6" CITY REQ.)
 REQUIRED SOIL BEARING PER PLANS 8,000
 PSF.
  
 1) THE STRUCTURE IS LOCATED IN AN A9
 FLOOD ZONE AN ELEVATION CERTIFICATE WILL
 BE REQUIRED. ALL EQUIPMENT MUST ALSO BE
 LOCATED 6" ABOVE BFE.
  
 2) THE PROPERTY LINES HAVE BEEN CHANGED
 BY A DECLARATION OF CONDOMINIUM ON FILE
 WITH THE PROPERTY APPRAISER. THE NEW
 PROPERTY CONTROL NUMBER THAT HAS BEEN
 ASSIGNED IS PCN 74-43-43-29-22-000-0030.
  
 SEE ATTACHMENT. THESE NEW PROPERTY LINES
 ARE THE ONES THAT THE FIRE SEPARATION
 DISTANCES WILL BE BASED ON. PROVIDE A
 SITE PLAN/SURVEY WITH THE DISTANCES FROM
 THE BUILDING TO THE "CONDO" PROPERTY
 LINES SPECIFIED. BASED ON THE LOCATIONS
 OF THE "CONDO" PROPERTY LINES, THE
 STRUCTURE DOES NOT COMPLY WITH FBC 704.8
 FOR ALLOWABLE AREA OF OPENINGS. NOTE:
 FOOTNOTE C TO TABLE 704.8 ALLOWS
 UNLIMITED OPENING AREAS FOR OPEN PARKING
 STRUCTURES WITH A FIRE SEPARATION OF
 GREATER THAN 10 FEET.
  
 3)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
 THE FOUNDATION PLANS SUBMITTED TO THE
 COUNTY DID NOT SPECIFY THE FUTURE 2700
 SQFT TENNANT SPACE FOR A BUSINESS. THERE
 WILL BE FEES DUE FOR THIS AREA.
  
 4) THE FIRE SPRINKLER PLANS THAT WERE
 SUBMITTED SPECIFY THAT THE OPEN GARAGE
 IS NOT REQUIRED TO BE SPRINKLERED AND
 THAT THE TENNANT SPACE AND STORAGE/
 EQUIPMENT ROOMS ARE SPRINKLERED. THIS IS
 NOT CORRECT. PLEASE SEE FBC 903.6.1.
 ANY BUILDING WHICH IS OF THREE STORIES
 OR MORE IN HEIGHT SHALL BE EQUIPPED WITH
 AN APPROVED AUTOMATIC SPRINKLER SYSTEM
 INSTALLED IN ACCORDANCE WITH SECTION
 903.1 .
 EXCEPTIONS:
 2.A STAND-ALONE PARKING GARAGE
 CONSTRUCTED WITH NONCOMBUSTIBLE
 MATERIALS, THE DESIGN OF WHICH IS SUCH
 THAT ALL LEVELS OF THE GARAGE ARE
 UNIFORMLY OPEN TO THE ATMOSPHERE ON ALL
 SIDES WITH THE PERCENTAGES OF OPENINGS
 EQUAL TO OR GREATER THAN THOSE SPECIFIED
 IN SECTION 406.3 . SUCH GARAGES SHALL BE
 SEPARATED FROM ANY OTHER STRUCTURE BY
 NOT LESS THAN 20 FEET (6096 MM). A
 STAND-ALONE PARKING GARAGE IS ONE THAT
 IS SOLELY FOR THE PARKING OF VEHICLES
 AND DOES NOT HAVE ANY OTHER OCCUPANCY
 GROUP IN THE BUILDING.
 THERE IS A BUSINESS OCCUPANCY IN THE
 BUILDING AND THE DISTANCE TO PROPERTY
 LINES IS LESS THAN 20 FEET (ANOTHER
 STRUCTURE COULD BE BUILT WITHIN 20
 FEET).
  
 5) THE BUILDING DATA ON SHEET A2.0.1
 INCORRECTLY REFERENCES TABLE 500. THE
 CORRECT TABLE IS 2004 FBC TABLE 503.
  
 6) THE BUILDING DATA ON SHEET A2.0.1 IS
 INCORRECT. SEE FBC TABLE 503. BUSINESS/
 TYPE II-B IS LIMITED TO 4 STORIES AND
 23,000 SQFT. PER FLOOR.STORAGE S-2/
 TYPE II-B IS ALSO LIMITED TO 4 STORIES
 AND 26,000 SQFT PER FLOOR.
 UNLESS THE BUILDING OCCUPANCY IS
 SEPARATED BY 2 HOUR FIRE BARRIER WALLS
 AND CEILING ASSEMBLY PER FBC 302.3.2 THE
 MOST RESTRICTIVE LIMITS FOR HEIGHT AND
 AREA OF TABLE 503 BASED ON CONSTRUCTION
 TYPE AND OCCUPANCY SHALL BE APPLIED TO
 THE ENTIRE BUILDING.
 NOTE: FBC 504.2 ALLOWS HEIGHT & STORY
 INCREASES FOR A BUILDING EQUIPPED
 THROUGHOUT WITH AN APPROVED SPRINKLER
 SYSTEM IN ACCORDANCE WITH SECTION
 903.3.1.1.
 FBC 406.3.6 ALLOWS OPEN PARKING GARAGES
 OF TYPE II CONSTRUCTION WITH ALL SIDES
 OPEN TO HAVE UNLIMITED AREA WHEN THE
 HEIGTH DOES NOT EXCEED 75 FEET.
  
 7) FBC* (CITY AMENDMENTS)109.3.6.1
 REQUIRES A STRUCTURAL INSPECTION PLAN TO
 BE SUBMITTED PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT FOR THE CONSTRUCTION OF
 A THRESHOLD BUILDING. PLEASE SUBMIT A
 SIGNED AND SEALED STRUCTURAL INSPECTION
 PLAN FROM THE ENGINEER OF RECORD FOR THE
 STRUCTURE.
  
 8) PLEASE REVISE THE REFERENCE TO
 ASCE7-98 IN THE NOTES UNDER THE GROSS
 UPLIFT AND WALL DESIGN TABLES ON S4.O.
 THE CORRECT REFERENCE IS ASCE7-02.
  
 9) ON SHEET A8.1.1 PLEASE REPLACE SBC
 WITH FBC.
  
 10) ON SHEET A9.1.1 PLEASE CORRECT THE
 NOTE UNDER TYPE "C" WALLS TO REFERENCE
 THE FBC AND NOT THE SFBC. ALSO CORRECT
 THE TABLE SPECIFIED.
  
 11) FBC 11-4.6.4 VAN ACCESSIBLE PARKING
 SPACES LOCATED WITHIN A PARKING
 STRUCTURE SHALL HAVE AN ADDITIONAL SIGN
 READING ?VAN ACCESSIBLE? MOUNTED BELOW
 THE SYMBOL OF ACCESSIBILITY. SUCH SIGNS
 SHALL BE LOCATED SO THEY CANNOT BE
 OBSCURED BY A VEHICLE PARKED IN THE
 SPACE.
  
 12) PROVIDE NOTE ON PLANS TO SHOW
 COMPLIANCE WITH FBC 3002.4, WHICH
 REQUIRES AT LEAST ONE PASSENGER ELEVATOR
 TO ACCOMMODATE AN AMBULANCE STRETCHER
 76" LONG AND 26" WIDE IN THE HORIZONTAL
 POSITION.
  
 13) PROVIDE NOTE ON PLANS TO SPECIFY
 THAT ELEVATOR IS TO COMPLY WITH FBC
 11-4.10 FOR ACCESSIBILITY AND ASME
 A17.1-1990 'SAFETY CODE FOR ELEVATORS
 AND ESCALATORS'.
  
 14) FBC 11-4.6.2 INDICATE THE ACCESSIBLE
 ROUTE OF TRAVEL FROM THE PARKING GARAGE
 TO THE ACCESSIBLE ENTRANCE OF THE
 BUILDING IT SERVES.
  
 15) FBC 1008.1.2 REQUIRES EGRESS DOORS
 TO SWING IN THE DIRECTION OF TRAVEL
 WHERE SERVING AN OCCUPANT LOAD OF 50 OR
 MORE PERSONS. THE MIDLEVEL PLANS ON
 SHEETS A2.0.2 AND A2.2.1 SHOW DOOR 201
 WITH THE WRONG SWING.
  
 16) FBC 1008.1.1 REQUIRES EGRESS DOORS
 TO HAVE A MINIMUM CLEAR WIDTH OF NOT
 LESS THAN 32". ON A2.0.1 E7 THRU E10 ARE
 SPECIFIED WITH 30" WIDTHS.
  
 17) ON SHEET A8.1.1 OPENINGS 103 & 104
 ARE SPECIFIED AS WINDOWS W/SIDELITES AND
 AS FUTURE EGRESS DOORS. THESE SHOULD NOT
 BE LISTED AS EGRESS OPENINGS ON SHEET
 A2.0.1. PLEASE CLARIFY.
  
 18) SUBMIT PRODUCT APPROVALS FOR THE
 ROOFING MATERIALS. PLANS SPECIFY 4 PLY
 MODIFIED HOT MOP.
  
 19) THE EXTERIOR BUILDING ELEVATIONS
 ELEVATIONS ON SHEET A3.1.3 APPEAR TO
 SHOW TRANSOM WINDOWS ABOVE THE EXTERIOR
 STAIRWAY DOORS AT THE FIRST LEVEL.
 SPECIFY THIS IN THE DOOR SCHEDULE AND
 SUBMIT PRODUCT APPROVALS FOR THE TRANSOM
 WINDOWS AND THE STRUCTURAL MULLIONS.
  
 20) IF THE PRODUCTS HAVE A STATE PRODUCT
 APPROVAL IN ADDITION TO THE MIAMI DADE
 NOA, PLEASE PRINT A COVER SHEET WITH THE
 FL# FROM THE STATE WEBSITE
 (WWW.FLORIDABUILDING.ORG) AND ATTACH IT
 TO THE NOA.
  
 21) FBC 106.3.3*(CITY AMENDMENTS)
 REQUIRES PRODUCTS REGULATED BY DCA RULE
 9B-72 TO BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD.
 PRODUCT APPROVALS SUBMITTED HAVE NOT
 BEEN APPROVED IN WRITING BY THE DESIGNER
 OF RECORD.
  
 22) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLAN SHEETS IN ORDER
 TO ADDRESS THE COMMENTS, PLEASE REMOVE
 THE OLD SHEETS AND INSERT THE NEW ONES.
 ONE COPY OF THE OLD PLANS SHEETS SHOULD
 BE ATTACHED TO FORM A SET OF 'OLD/VOIDED
 SHEETS' FOR COMPARISON OF REVISIONS WHEN
 REVIEWING THE RESUBMITTED PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-18 Cont ID  
Sent By rmcdouga Date 2006-04-18 Time 14:19 Rev Time 0.00
Received By rmcdouga Date 2006-04-12 Time 07:04 Sent To  
Notes
2006-04-17 00:00:00DENIED BY BUILDING
  
 1621 WORTHINGTON ROAD
 5 STORY PARKING GARAGE
 TYPE II-A (SPRINKLERED)
 MIXED OCCUPANCY (S-2 STORAGE &
 BUSINESS) NOTE: PLUMBING SHEET P3.4
 INDICATES A FUTURE GYM WHICH WOULD BE AN
 ASSEMBLY OCCUPANCY.
 FLOOD ZONE A9 BFE 13' (+6"CITY REQ.)
 REQUIRED SOIL BEARING PER PLANS 2,000
 PSF
  
 1) STRUCTURE IS LOCATED IN AN A9 FLOOD
 ZONE AN ELEVTION CERTIFICATE WILL BE
 REQUIRED. ALL EQUIPMENT MUST ALSO BE
 LOCATED 6" ABOVE REQUIRED BFE.
  
 2) SUBMIT A SIGNED AND SEALED SURVEY.
 INDICATE THE LOCATION OF THE ASSUMED
 PROPERTY LINE BETWEEN THE PROPOSED
 PARKING GARAGE AND THE PROPOSED BUILDING
 TO THE WEST. SEE FIRE SEPARATION
 DISTANCE FBC 702.1 AND 704.3.
  
 3) FBC 1802.2.1AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 4)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 5)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 6) SUBMIT FIRE SPRINKLER DRAWINGS AS
 REQUIRED BY FBC 106.3.5.
  
 7) FBC 13-103.0ENERGY CODE COMPLIANCE
 SHALL BE DEMONSTRATED BY SUBMITTAL OF
 APPROPRIATE CODE COMPLIANCE FORMS.
 FBC 13-101.1.6SHELL BUILDINGS.
 THE WHOLE BUILDING (INCL. FUTURE TENANT
 SPACE) SHALL BE CONSIDERED.SHELL
 BUILDINGS SHALL BE SHOWN TO COMPLY WITH
 METHOD B (SEE SUB-CHAPTER 4).ALL
 ASSUMPTIONS MADE ABOUT SYSTEMS, NOT
 SHOWN ON THE CURRENT PLANS, SHALL BE
 LISTED AND APPENDED TO THE FORM 400B FOR
 SUBMITTAL.THIS WILL BE COMPARED, AT A
 LATER DATE, TO THE ACTUAL SYSTEMS
 PROPOSED BY THE FUTURE TENANT(S).THE
 ASSUMPTIONS LISTED ON THE APPENDIX SHEET
 SHALL BE AT LEAST THE MINIMUM STANDARD
 (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE
 BUILDING TO BE OCCUPIED FOR IT'S
 INTENDED PURPOSE.
  
 8) FBC* 109.3.6.1SPECIAL INSPECTOR.A
 STRUCTURAL INSPECTION PLAN MUST BE
 SUBMITTED PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT FOR THE CONSTRUCTION OF
 A THRESHOLD BUILDING.A THRESHOLD
 BUILDING IS ANY BUILDING WHICH IS
 GREATER THAN THREE STORIES OR 50 FEET IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY
 OCCUPANCY WITH 5,000 SQFT AREA AND
 GREATER THAN 500 OCCUPANTS.THREE
 COPIES OF THE PLANS AND OTHER DOCUMENTS
 WILL BE REQUIRED FOR PERMITTING
 PURPOSES. ALSO, PLEASE ARRANGE WITH
 HAROLD PISKURA (INSPECTION SERVICES
 MANAGER - TEL:561 805 6711), A MEETING
 INVOLVING THE OWNER, THRESHOLD
 INSPECTOR, JOB INSPECTOR, CONTRACTOR AND
 ENGINEER.
  
 9)FBC* 109.3.6.4.4 ALL PLANS FOR THE
 BUILDING WHICH ARE REQUIRED TO BE SIGNED
 AND SEALED BY THE ARCHITECT OR ENGINEER
 OF RECORD CON- TAIN A STATEMENT THAT, TO
 THE BEST OF THE ARCHITECT'S PR
 ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 10) FBC* 106.1.3 QUALITY OF BUILDING
 PLANS. BUILDING PLANS SHALL BE DRAWN TO
 A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER
 ACCEPTABLE MEDIUM.
  
 11) FBC 1603.1.4WIND DESIGN DATA.THE
 PLANS SHALL STATE THE BASIC WIND SPEED,
 WIND IMPORTANCE FACTOR, WIND EXPOSURE
 CATEGORY, INTERNAL PRESSURE COEFFICIENT,
 AND EXTERIOR COMPONENT AND CLADDING
 DESIGN WIND PRESSURES.ADD THIS
 INFORMATION TO THE PLANS. INFORMATION
 LEFT BLANK ON SHEET S4.O.
  
 12) THE EDITION OF ASCE 7 REFERENCED IN
 THE 2004 FBC IS ASCE 7-02. PLEASE REVISE
 THE EDITIONS OF ASCE 7 SPECIFIED ON
 SHEET S4.0.
  
 13) SPECIFY ON THE PLANS IF THE
 STRUCTURE IS DESIGNED AS ENCLOSED,
 PARTIALLY ENCLOSED OR OPEN.
  
 14) SPECIFY THE SCALE OF THE LIFE SAFETY
 PLAN FOR THE EQUIPMENT ROOMS ON SHEET
 A003.
  
 15) SPECIFY THE NEGATIVE AND POSITIVE
 WINDLOAD PRESSURES FOR THE STOREFRONTS
 AT THE TENNANT SPACE, THE EXTERIOR DOOR
 TO THE MECHANICAL ROOMS, AND THE DOORS
 TO THE EGRESS STAIRS. FBC 1609
  
 16) NOTE 2 ON S5.0 IS COVERED BY A
 PRINTING ERROR. PLEASE CORRECT.
  
 17) SUBMIT PRODUCT APPROVALS FOR THE
 DOOR AND WINDOW OPENINGS SUBJECT TO
 WINDLOADING, ROOFING MATERIALS, STORM
 PANELS, ETC.
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE WWW.
 FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX
 (IF YOU FIND THAT THE QUOTED WEB PAGE IS
 NO LONGER AVAILABLE, PLEASE INFORM THE
 PLAN REVIEWER)
 FBC 106.3.3*(CITY AMENDMENTS) REQUIRES
 PRODUCTS REGULATED BY DCA RULE 9B-72 TO
 BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 18) SUBMIT SPECIFICATIONS FOR THE FIRE
 RATED DOORS, DOOR CLOSERS, HARDWARE,
 ETC.
  
 19) PLEASE REVISE OCCUPANCY TYPE FOR
 FUTURE GYMNASIUM TO GROUP A (ASSEMBLY,
 A-3). REVISE OCCUPANT LOAD CALCS.,
 TENANT SEPARATION, ETC. ACCORDINGLY. THE
 PARKING AREA AND STORAGE AREA ARE GROUP
 S-2 STORAGE.
  
 20) ON SHEET S1.0 SOME OF THE SECTION
 MARKERS ARE NOT AT THE PROPER LOCATIONS.
 PLEASE CORRECT.
  
 21) ON SHEET S2.0 THERE ARE TWO
 DIFFERENT SECTION DRAWINGS LABELED
 5/S2.0. SECTION 6/S2.0 SHOULD BE LABELED
 AS 7/S2.0.
  
 22) PROVIDE A COLUMN SCHEDULE. SEE NOTE
 14 ON S1.0.
  
 23) SHEETS S1.1 AND A1.2 HAVE SECTIONS
 MARKED X/X. PLEASE CLARIFY.
  
 24) MARKS 5/S3.0 ON SHEET S1.1 MARK
 6/S3.0 ON SHEET S1.2 ARE NOT AT THE
 CORRECT LOCATIONS. PLEASE CORRECT.
  
 25) PLEASE REVISE NOTE 8.06 ON A000 TO
 COMPLY WITH THE 2004 FLORIDA BUILDING
 CODE. SEE FBC 1609.1.4.
  
 26) THE NUMBERS OF PARKING SPACES LISTED
 FOR THE FIRST FLOOR ON A002 AND A003 DO
 NOT CONCUR.
  
 27) THE ELEVATOR SHALL COMPLY WITH FBC
 11-4.10 FOR ACCESSIBILITY AND WITH ASME
 A17.1-1990, 'SAFETY CODE FOR ELEVATORS
 AND ESCALATORS'.
  
 28) FBC 3002.4STRETCHER ACCESSIBLE
 ELEVATOR.AT LEAST ONE PASSENGER
 ELEVATOR SHALL ACCOMMODATE AN AMBULANCE
 STRETCHER 76" LONG AND 24" WIDE IN THE
 HORIZONTAL POSITION.THIS ELEVATOR
 SHALL BE IDENTIFIED BY SIGNAGE.AMEND
 THE PLANS TO DEMONSTRATE COMPLIANCE.
  
 29) FBC 11-4.1.2(5)(B) REQUIRES ONE IN
 EVERY EIGHT ACCESSIBLE SPACES TO BE VAN
 ACCESSIBLE AND BE DESIGNED AS REQUIRED
 BY SECTION 11-4.6.3. BASED ON THE NUMBER
 OF ACCESSIBLE SPACES, TWO VAN ACCESSIBLE
 SPACES ARE REQUIRED. FBC 11-4.6.4
 REQUIRES VAN ACCESSIBLE SIGNAGE. FBC
 11-4.6.5 REQUIRES 98" MINIMUM VERTICAL
 CLEARANCE AT THE VAN ACCESSIBLE PARKING
 SPACES AND ALONG THE ACCESS ROUTE TO AND
 EXITS FROM SUCH SPACES. NO SPRINKLER
 PIPING, ROOF DRAIN PIPING, ETC. WITHIN
 THE REQUIRED 98" CLEARANCE. SHOW
 COMPLIANCE.
  
 30)FBC 406.2.2 REQUIRES THE CLEAR HEIGHT
 OF EACH FLOOR LEVEL IN VECHICAL AND
 PEDESTRIAN TRAFFIC AREAS TO BE NOT LESS
 THAN 7 FEET.
  
 31) SHOW COMPLIANCE WITH FBC 11-4.6.2
 INDICATE THE ACCESSIBLE ROUTE OF TRAVEL
 FROM THE PARKING GARAGE TO THE
 ACCESSIBLE ENTRANCE OF THE BUILDING IT
 SERVES.ACCESSIBLE PARKING SPACES MUST
 BE LOCATED ON AN ACCESSIBLE ROUTE NO
 LESS THAN 44" WIDE SO THAT USERS WILL
 NOT BE COMPELLED TO WALK OR WHEEL BEHIND
 PARKED VECHILES.
  
 32) ON SHEET A003 UNDER APPLICABLE
 CODES, HIGH VELOCITY HURRICANE ZONES,
 CHAPTERS 15 & 16 DO NOT APPLY TO THIS
 PROJECT. PLEASE REVISE. CITY OF WEST
 PALM BEACH IS NOT LOCATED IN THE HVHZ.
 ALSO ON A003 THE SECTION TITLED
 HURRICANE CRITERIA CHAPTER 15 & 16 NEEDS
 TO BE REVISED. SEE NOTES ON PLANS.
  
 33)FBC 11-4.15.2 SPECIFIES THAT
 ACCESSIBLE DRINKING FOUNTIANS SHALL BE
 NO HIGHER THAN 36" TO THE SPOUT OUTLET.
 REVISE DRINKING FOUNTAIN DRAWING ON
 A006.
  
 34) NOTE 1 ON SHEET A006 FOR FAIR
 HOUSING GUIDELINES DOES NOT APPLY TO
 THIS PROJECT. THIS PARKING GARAGE IS NOT
 ACCESSORY TO A RESIDENTIAL OCCUPANCY.
  
 35) THE FIRE RATING OF THE WALLS IS NOT
 INDICATED ON THE LIFE SAFETY PLANS,
 ALTHOUGH THE LEGEND IS GIVEN ON SHEET
 A003. SPECIFY THE FIRE RATINGS OF THE
 WALLS AND FLOOR/CEILINGS.
  
 36) THE EXIT FROM THE SOUTHEAST EGRESS
 STAIR DOES NOT EXIT TO THE EXTERIOR OF
 THE BUILDING. FBC 406.2.5 DOES NOT ALLOW
 VECHICLE RAMPS TO SERVE AS AN EXIT
 ELEMENT.
  
 37) PROVIDE A STAIR DETAIL SPECIFYING
 THE RISERS, TREADS, VERTICAL RISE
 BETWEEN LANDINGS, HEADROOM, HANDRAILS,
 GUARDS, STAIR WIDTH, ETC. PLEASE USE A
 LARGER SCALE THAN SHOWN ON A2O2 & A203.
 SEE FBC 1009.
  
 38) NOTE: THE COMMON PATH OF TRAVEL IN
 THE FUTURE TENNANT SPACE IS ACCEPTABLE
 FOR A BUSSINESS OCCUPANCY, BUT MAY NOT
 BE FOR AN ASSEMBLY OCCUPANCY. THE COMMON
 PATH OF TRAVEL IS 20' FOR ASSEMBLY WITH
 MORE THAN 50 OCCUPANTS.
  
 39) FBC 1008.1.2 REQUIRES EGRESS DOORS
 TO SWING IN THE DIRRECTION OF TRAVEL
 WHERE SERVING AN OCCUPANT LOAD OF 50 OR
 MORE PERSONS. EGRESS STAIRS DO NOT
 COMPLY.
  
 40) THE EXIT TO THE EXTERIOR IS NOT
 SHOWN FOR THE NORTHWEST EGRESS STAIR.
 THE SITE PLAN ON A001 SHOWS EXTERIOR
 STAIRS AT THIS LOCATION. PROVIDE
 DETAILS.
  
 41) THE DOOR SCHEDULE ON A400 LISTS ALL
 DOORS AS 3-0 X 8-0, THIS APPEARS TO
 DIFFER WITH THE EGRESS WIDTHS PROVIDED
 ON THE LIFE SAFETY PLAN AT THE TENNANT
 SPACE. FBC 1008.1.1 REQUIRES A MINIMUM
 CLEAR WIDTH OF NOT LESS THAN 32".
  
 42) THE EXIT LIGHTS AT THE ELEVATOR AND
 DOOR 115 APPEAR TO BE LOCATED
 INCORRECTLY. THE EXIT LIGHT AT DOOR 116
 IS LOCATED SO THAT IT WILL DIRECT PEOPLE
 BACK INTO THE GARAGE. PLEASE CORRECT.
  
 43) SPECIFY GUARDS AND VECHICLE BARRIERS
 AS REQUIRED BY FBC 406.2.3 AND 406.2.4
 AND DESIGNED IN ACCORDANCE WITH FBC
 1607.7. PROVIDE DETAILS.
  
 44) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-06-25 Cont ID  
Sent By dpalmer Date 2007-06-25 Time 15:39 Rev Time 0.00
Received By dpalmer Date 2007-06-25 Time 14:54 Sent To PC
Notes
2007-06-25 15:39:34ELEC REV OK, STAMPED.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-04-22 Cont ID  
Sent By dpalmer Date 2007-04-22 Time 09:05 Rev Time 0.00
Received By dpalmer Date 2007-04-22 Time 08:44 Sent To  
Notes
2007-04-22 09:06:12** UNSAT **
  
 1) NOTE: PLEASE SEE 620.23, 620.24 FOR REQUIRED
 DEDICATED CIRCUITS. THESE MAY NOT FEED OTHER AREAS
 AND/OR EACH OTHER.
  
 2) NOTE: PLEASE SEE REDLINED NOTES FROM 10/6/06 WHICH
 REQUIRED THE ATTACHMENT LOCATIONS TO BE SHOWN FOR
 TRANSFORMER.
 PLEASE SEE 250.20,250.30, 250.66.
 PLEASE KNOW THIS WAS REDLINED ON PLANS FOR ISSUANCE.
  
 ** PLEASE SEE POSSIBLE BUILDING REVIEW NOTES.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-10-06 Cont ID  
Sent By dpalmer Date 2006-10-06 Time 11:48 Rev Time 0.00
Received By dpalmer Date 2006-10-06 Time 11:48 Sent To  
Notes
2006-10-06 00:00:00REDLINED 250.30, 250.20, AND 250.66
 FOR THE GROUNDING ELECTRODE ATTACHMENT
 FOR THE TRANSFORMER.
  
  
 ALL THREE SETS OF ELECTRICAL PLANS
 STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-18 Cont ID  
Sent By dpalmer Date 2006-06-18 Time 16:03 Rev Time 0.00
Received By dpalmer Date 2006-06-18 Time 13:49 Sent To  
Notes
2006-06-18 00:00:00IN ELEC FOR REVIEW, REVIEW IN PROGRESS.
 ***** UNSAT 2ND REVIEW ****
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW AND SOME NEW DUE TO MANY ITEMS ON
 PLANS BEING COMPLETELY REVISED.
  
 ** PLEASE SEE THAT AN ADDRESS WAS
 ASSIGNED FOR PROJECT AND SHOULD BE
 REFLECTED IN TITLE BLOCKS OF ALL SHEETS.
 (1621 WORTHINGTON RD.)
  
 1) NOTE: PLEASE SUBMIT ALL MANUFACTURE'S
 CUT/SPEC SHEETS FOR THE FOLLOWING.
 FUEL TANK, WP ENCLOSURE FOR GEN.
 THE GEN AND ATS SPCES WERE SUBMITTED AND
 ARE OK.
 PLEASE HOWEVER "HIGHLIGHT" THE GEN AS
 INDICATED ON PLANS ON THE SPEC SHEETS.
  
 ** ON PREVIOUS REVIEW**
  
 2) NOTE: PLEASE SUBMIT PHOTO-METRICS
 UNDER NORMAL AND EM CONDITIONS FOR ALL
 EGRESS AREAS. THE NORMAL WERE SUBMITTED,
 HOWEVER COULD NOT LOCATE EM LEVELS.
 MIN 1FT CANDLE. NFPA -101 7.8.1.3 ,
 7.9.2.2.
  
 ** PREVIOUS REVIEW**
  
 3) NOTE: PLEASE SEE FXTURE TYPES ON E0.1
 DO NOT CORRELATE WIHT MANY FIXTURES IN
 GARAGE AND STAIRS.
 STILL NEED TO VERIFY TYPE OF FIXTURE FOR
 STAIRS.
 215.5
  
 4) NOTE: PLEASE INDICATE THE OCP ON THE
 GENERATOR FOR EACH BREAKER THAT IS BEING
 INDICATED ON RISER.
 PLEASE INDICATE THE INTENDED LOAD(S).
 (IT IS NOTED THAT THE LOAD ON GGDP IS
 BEING SHOWN, HOWEVER RISER ALSO SHOWS
 GEN FEEDING OTHER LOADS?
 215.5,220,702.5 ETC.
  
 ** PREVIOUS REVIEW NOTE**
  
 5) NOTE: PLEASE SEE CALCULATIONS FOR FBC
 CHAPTER 13 ARE NEEDED PER 13-415.1.AB.1,
 13-415.2.ABC.1.
 PLEASE PROVIDE WITH ENERGY CALCS.
 PLEASE SEE ENGERY CALCSMUST BE SIGNED,
 DATED AND SEALED BY THE RESPONSIBLE
 DESIGNER OF RECORD.
 PLEASE SEE CALCS SUBMITTED FOR GYM SPACE
 WERE NOT SIGNED/SEALED.
 ** PLEASE SEE NEW "ST" DEVICES LOCATED
 IN ROOMS DO NOT INDICATE THE MAX TIMED
 FOR "ON".
 PLEASE SEE THIS CAN/SHOULD ALSO BE
 LOCATED ON ELECTRICAL LEGEND.
  
 ** PREVIOUS NOTES**
  
 6) NOTE: PLEASE SEE LOADS WERE SHOWN AS
 "BLANK" ON PREVIOUS PLANS. PLEASE SEE
 LOADS ARE NOW SHOWN, HOWEVER CONTINUOUS
 LOADS WHICH ARE REQUIRED TO BE SHOWN
 @125% DO NOT INDICATE THIS?
 PLEASE ALSO SEE ANY LARGEST MOTORS SHALL
 ALSO INDICATE 125%.
 PLEASE CLARIFY LOADS WHICH ARE BEING
 SHOWN ON "GMDP" FOR "GLH/GL1" AS BOTH
 PANELS ARE SHOWN WITHOUT ANY LOADS.
 WHERE IS THE 20KV COMING FROM?
 215.5, 230.42,215.3 220
  
 7) NOTE: PLEASE SEE "GGDP" SHALL
 INDICATE A SIGN AS EM MAIN.
 PLEASE SEE 702.7 FOR SIGNALS REQUIRED.
 702.8,701.8,701.9, 230.2E
  
 ** FOLLOW NOTES DO NOT APPLY TO KAMM
 CONSULTING ENG'S.
  
 8) NOTE: PLEASE SEE "S" SHEETS ARE BIENG
 SEAL WHICH IS NO LONGER ACCEPTABLE UNDER
 FAC 61G15-23.001.
 PLEASE KNOW, IN FEB 04, A RULING BY THE
 FLORIDA BOARD OF PROFESSIONAL ENGINEER'S
 FOR A CHANGE IN THE WORDING IN THE SEAL.
 PLEASE KNOW, THE WORDING OF
 "CERTIFICATE" COULD NO LONGER BE USED
 AND THE NEW WORDING OF "LICENSE" WAS
 REQUIRED IN SAID SEAL.
 PLEASE KNOW THAT AN EXTENSION WAS
 GRANTED TODEC 31ST, 2005 , HOWEVER ALL
 PLANS AFTER SUCH DATE SHALL CONTAIN THE
 NEW SEAL WITH THE WORDING OF "LICENSE".
 THIS MAY ALSO BE IN BUILDING REVIEW
 COMMENTS.
  
 9) NOTE: PLEASE SEE LANDSCAPE PLANS ARE
 STILL INDICATING ELECTRICAL LIGHTING
 ETC.
 PLEASE KNOW, ALL ELECTRICAL LIGHTING
 SHALL BE REMOVED FROM SAID PLANS, OR
 REVISE ELECTRICAL PLANS TO INCLUDE
 THESE.
 PLEASE ALSO SEE FBC CHAPTER 13 FOR
 OUTSIDE LANDSCAPE LT-ING.
  
 10) NOTE: PLEASE SEE MISSING REQUIRED
 INFORMATION IN TITLE BLOCK FOR LANDSCAPE
 ARCHITECT AND FIRM.
 PLEASE SEE 61G1-16.004, FS 481.219
 MISSING CERTIFICATE OF AUTHORIZATION #.
  
 11) NOTE: PLEASE SEE FS 553.80(2)(B)
 WITH RESPECT TO ANY REPEAT COMMENTS.
 THIS IS ONLY A NOTICE.
  
 ** PLEASE ONLY SUBMIT ONE COPY OF
 OLD/VOIDED SETS FOR REVIEW AND
 REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
 ** NOTE ADDED TO FRONT SCREEN.
 NOTICE OF COMMENCMENT IN PACKAGE HAS
 EXPIRED PER FS 713.13(2).
 WILL NEED A NEW RE-RECORDED NOC BEFORE
 PICKING UP PERMIT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-01 Cont ID  
Sent By dpalmer Date 2006-02-01 Time 18:16 Rev Time 0.00
Received By dpalmer Date 2006-01-31 Time 21:05 Sent To  
Notes
2006-02-10 00:00:00*** PLEASE SEE NOTES UNDER MAIN BLDG
 ALSO FOR ADDRESS.
  
 PLEASE KNOW, THE LEGAL PROPERTY MAY NOT
 CHANGE AS THE ELECTRICAL SERVICEAND
 GENERATORS COME FROM GARAGE BLDG TO MAIN
 BLDG.
 PLEASE SEE ANY LEGAL PROPPERTY PCN
 CHNAGE ETC WILL REQUIRE LEGAL EASEMENTS
 ETC.
2006-02-01 00:00:00********** UNSAT **********
  
 ** PLEASE KNOW, PLANS AND SUBMITTIALS
 ARE NOT COMPLETE AT THIS TIME.
  
  
 1)NOTE: PLEASE SEE ALL CURRENT CODES
 SHALL BE REFERENCED TO THE CURRENT CODES
 IN EFFECT. PLEASE SEE PLANS CALL FOR
 2001 FLORIDA BUILDING CODE. PLEASE KNOW,
 AS OF OCT 1ST, 2005 THE NEW FBC IS THE
 2004 EDITION. PLEASE SEE THE FOLLOWING
 SHALL BE REFERENCED. 2003 NFPA-101, 2002
 NFPA-70, AND 2002 NFPA-72
  
 2)NOTE: PLANS WILL REQUIRED BATTERY BACK
 UP LT FIXTURES IN MAIN ELECTRICAL RM,
 ELEVATOR RMS.
 PLEASE ALSO KNOW BATTERY BACK UP
 FIXTURES WILL BE REQUIRED IN STAIRWAY
 AND EGRESS PATHS TO PROVIDE A MIN OF 1FT
 CANDLE OF LIGHT BY SOME SORT OF BATTEY
 BACK UP FIXTURE. PLEASE SEE NFPA-101
 7.9.2.2, TRIPPING OR SHUTTING OFF ANY
 SINGLE DEVICE OR MEANS OF OVERCURRENT
 PROTECTION SHALL NOT LEAVE ANY ONE
 EGRESS PATH IN TOTAL DARKNESS.
 PLEASE PROVIDE PHOTOMETRICS FOR
 STAIRWAYS, AS THE 2003 LS 101 7.8.1.3
 REQUIRES A MIN OF 10FY CANDLES(108LUX)
 IN STAIRWAYS UNDER NORMAL LIGHTING
 CONDITIONS AND 7.9.2.2 PERMITS THE
 DERATING TO A MIN OF 1FT CANDLE UNDER
 EMERGENCY CONDITIONS.
 700.16.,700.12E ETC
  
 3)NOTE: PLEASE SEE POSSIBLE BLDG
 COMMENTS AS STAIRWAY DOORS SEEM TO SWING
 IN, INSTEAD OF THE DIRECTION OF EGRESS.
 PLEASE SEE ANY POSSIBLE COMMENTS WITH
 RESPECT TO THE "FUTURE" TENANT SPACE.
 (GYM).
  
 4)NOTE: PLEASE SUBMIT ALL MANUFACTURES
 SPECS/CUT SHEETS FOR GENERATOR, ATS,
 ETC. PLEASE PROVIDE SPECS FOR ANY TANKS
 FOR THE PRIME-MOVER OF GEN.
 PLEASE BE SURE ALL SPECS ETC INDICATE
 LISTINGS FROM A NRTL.
 NO REVIEW CAN BE DONE AT THIS TIME.
  
 5)NOTE: PLEASE SEE NO MAIN IS SHOWN ON
 THE LINE-SIDE OF ATS SHOWN. PLEASE SEE
 THE FOLLOWING COMMENT WITH RESPECT TO
 GFP FOR SYSTEMS 277/480V 1000A'[S OR
 MORE.
 230.70,ETC.
  
 6)NOTE: PLEASE SEE ATS MANUFACTUREA S
 GFP IS REQUIED BY THE NEC FOR SERVICE
 AND MAY REQUIRE A 4-POLE ATS FOR GFP TO
 WORK CORRECTLY.
 PLEASE PROVIDE INFORMATION; PLEASE SEE
 GENERATOR IS ALREADY SHOWN AS A
 SEPARATELY DERIVED SYSTEM AS REQUIRED,
 HOWEVER NOT ENOUGH ATS INFORMATION IS
 SUBMITTED FOR CORRELATION OF REVIEW FOR
 CODE COMPLIANCE.
 EXAMPLE, PLEASE SEE TEXT TAKEN FROM
 ASCO:
 "WHERE GROUND FAULTPROTECTION IS
 TRIGGERED BY THE CODE AND AN ALTERNATE
 POWER SUPPLY IS INCLUDED,SWITCHING OF
 THE NEUTRAL BECOMES NECESSARY. THE
 CIRCUIT SHOWN ABOVE ILLUSTRATESSUCH A
 CIRCUMSTANCE. THE SERVICE IS LARGER THAN
 1,000 AMPS. CONSEQUENTLY, GROUNDFAULT
 PROTECTION IS REQUIRED AT THE MAIN
 SERVICE DISCONNECT AT A MINIMUM. IF IT
 IS INSTALLED THERE AND THE GENERATOR
 NEUTRAL GROUNDING WAS THROUGH A SOLID
 CONNECTION TO THE MAIN SERVICE NEUTRAL,
 A GROUND FAULT WHEN THE GENERATOR IS
 FEEDING THE LOAD WILL CAUSE THE MAIN
 SERVICE DISCONNECT TO OPEN. THIS WILL
 NOTDISCONNECT THE ARCING FAULT FROM
 THE GENERATOR. COORDINATION IS THUS
 LOST."
  
 7)NOTE: PLEASE SEE SERVICE MAINS AS
 REQUIRED DO NOT INDICATE ANY GFP PER
 230.95,240.13 ETC.
  
 8)NOTE: PLEASE LABEL ALL MAINS, 1, 2, 3
 ETC, 1OF? 2 OF ? ETC.
  
 9)NOTE: PLEASE PROVIDE ONE LINE
 GROUNDING ELECTRODE DIAGRAM FOR BLDG, TO
 INCLUDE GROUNDING ELECTRODE RISER FOR
 ANY TRANSFORMERS. 250.30,250.58
  
 10)NOTE: PLEASE SEE PANELS , (MDP WHICH
 ARE NOT COMPLETE AT THIS TIME. PLEASE
 SEE SOME AREA OF PANELS WHERE XXX'S ARE
 SHOWN FOR REQUIRED INFORMATION.
 PLEASE SEE "GGP" WHERE BRANCH CIRCUIT
 INFORMATION APPEARS IN THE TITLE BLOCK
 OF SAID PANEL.
 PLEASE SEE OTHER PANELS WHERE ALL
 INFORMATION INDICATED IS SHOWN AS
 "SPARE"? PLEASE SPECIFY "FUTURE" USE AND
 FOR WHAT LOADS THESE WILL FEED.
  
 11)NOTE: PLEASE CORRELATE RISER DIAGRAM
 AND PANELS.
 PLEASE SEE "GLH", "GMDP", GLH", ETC,
 THESE ARE SHOWN BEING FED FROM OTHER
 EQUIPMENT ON RISER THAN LISTED ON PANEL
 SCHEDULES.
 PLEASE ALSO SEE "GDP", "GGP", AND "GLP",
 PLEASE SEE RISER, PLEASE SEE "T1B" AS
 THIS IS FED FROM TWO SEPARATE PANELS,
 AND CORRELATE WIRTH RISER.
 215.5
  
 12)NOTE: PLEASE SEE NOTES FOR
 DISTRIBUTION SYSTEM MENTIONS TO EXTEND
 TO MAIN BLDG, PLEASE SEE NOTES FROM MAIN
 BLDG REVIEW WHEN COMPLETED AS THIS MAY
 AFFECT ELECTRICAL SERVICE OR DESIGN AS
 SHOWN.
  
 13)NOTE: PLEASE COMPLETE ALL SERVICE
 ENTRANCE CONDUCTORS ON RISER ALONG WITH
 ALL FEEDERS.
 PLEASE SEE MISSING SEC'S TO EM SYSTEM,
 ATS OR NEW MAIN DISCONNECT, PLEASE SEE
 MISSING FEEDERS FROPM GEN, PLEASE SEE
 MISSING SEC'S TO GMDP, ATS TO GDP ETC .
 PLEASE COMPLETE RISER.
  
 14)NOTE: PLEASE SEE MISSING OVERCURRENT
 PROTECTION AT GENERATOR. PLEASE ALSO SEE
 MISSING LOAD CALCUALTIONS FOR INTENDED
 LOAD FOR GENERATOR.
 PLEASE ALSO SEE FOLLOWING COMMENT.
  
 15)NOTE: PLEASE COMPLETE AND SUBMIT MIN
 LOAD CALCUALTIONS AS REQUIRED PER
 NEC.220
 PLEASE SEE ALL MAIN DISTRIBUTIION
 SYSTEMS ARE SHOWING "BLANKS" FOR LOADS??
 PLEASE BE SURE TO INDICATE ALL LOADS. NO
 REVIEW OF THESE CAN BE DOINE AT THIS
 TIME.
 215.5
  
 16)NOTE: PLEASE SEE NOTES FOR GENERATORS
 AS INDICATED ON ELECTRICAL PLANS WHICH
 NOTES ALL GENERATOR CONDUITS PROCEEDING
 TO THE MAIN OFFICE BLDG??
 PLEASE INDICATE WHERE GENFOR GARAGE IS
 LOCATED?
 PLEASE ALSO SEE COMMENTS FOR MAIN BLDG
 AS THESE NOTES INDICATE ALL THESE
 FEEDERS SHALL PROCEED TO THE FIRST FLR
 MAIN ELECTRICAL ROOM, HOWEVER THIS DOES
 NOT SEEM TO CORRELATE WITH WHAT IS SHOWN
 ON MAIN BLDG PLANS.
 215.5
  
 17)NOTE: PLEASE SEE FBC 2004 CHAPTER 13,
 13-413.1ABC.1.1, .2 FOR VOLTAGE DROP
 INFORMATION NEEDED.
  
 18)NOTE: PELASE SEE LIGHTING
 REQUIREMENTS UNDER 13-415 FOR AREAS OF
 CONTROL AND TANDEM WIRING.
 PLEASE SPECIFY THIS INFORMATION ON
 PLANS.
  
 19)NOTE: PLEASE SEE LANDSCAPE PLANS
 MENTIONS AND NOTES LIGHTING AND TO SEE
 ELECTRICAL PLANS FOR THESE, HOWEVER
 THESE ITEMS COULD NOT BE LOCATED ON
 ELECTRICAL PLANS.
 PLEASE SUBMIT WIND LOAD CALCUALTIONS FOR
 ALL SITE LIGHTING POLES TO MEET FBC 140
 MPH.
  
 20)NOTE: PLEASE SEE LANDSCAPE PLANS ARE
 SEALED "PHOTO-COPIES" OF ARCHITECT'S
 SIGNATURE. PLEASE SEE FS 481.221 WHICH
 REQUIRES THE SIGNATURE TO BE AN ORIGINAL
 SIGNATURE.
  
 ** PLEASE KNOW, REVIEW FOR MAIN BLDG HAS
 NOT COMMENCED AT THIS TIME.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ** PLEASE REMOVE ALL OLD/VOIDED SHEETS
 AND ON.Y INSERT NEW REVISED SHEETS INTO
 COMPLETED SETS FOR REVIEW AND STAMPING.
 ONLY SUBMIT ONE COPY OF OLD/VOIDED
 SHEETS FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 DPALMER2WPB.ORG
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2006-11-02 Cont ID  
Sent By rchokshi Date 2006-11-02 Time 08:26 Rev Time 0.00
Received By rchokshi Date 2006-11-02 Time 08:26 Sent To  
Notes
2006-11-02 08:26:42PASS

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2006-10-06 Cont ID  
Sent By rchokshi Date 2006-10-06 Time 13:38 Rev Time 0.00
Received By rchokshi Date 2006-10-06 Time 13:12 Sent To  
Notes
2006-10-06 00:00:00 
 FOUND INCONSISTENCY IN LEGEND, FOR
 EXAMPLE, CIVIL SH 2 OF 5,IN LEGEND,
 PROPOSED STORM SEWER & CATCH BASIN HAS
 SQUARE SYMBOL AND ON DRAWING 142 FT 15"
 RCP HAS ROUND SYMBOL ON NORTH END, IS
 THIS AN INLET? ALSO IT SAYS 10.0 N.S. IS
 IT NORTH INVERT ELE? WHY TWO ELEVATIONS,
 10.0 N. S. WE SEE ONLY ONE END OF PIPE.
 PLEASE MAKE CORRECTION IN ALL SHEETS.
  
 YOU NEED TO SHOW DUMPSTER ENCLOSURE
 DETAILS AND DIMENTIONS PER CITY OF WPB
 STANDARDS
  
 PLEASE SHOW DETAILS ON DRAWINGS PER CITY
 OF WPB STANDARDS FOR SIDEWALK,DRIVEWAY,
 APPROACH,PARKINGS,HANDICAP PARKING PER
 ADA, ETC.,
  
 PLEASE RESPOND EACH ITEM SEPARATELY ON
 YOUR RESPONSE TO EXPEDITE THE PERMIT.
  
 RASIK CHOKSHI 805-6723

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2006-07-21 Cont ID  
Sent By rchokshi Date 2006-07-21 Time 16:25 Rev Time 0.00
Received By rchokshi Date 2006-07-21 Time 16:24 Sent To  
Notes
2006-07-21 00:00:00PLEASE PROVIDE DRAINAGE CALCULATIONS, &
 PLAN. HOW CISTERN TANKS ARE CONNECTED TO
 ANY OTHER SYSTEMS? DESIGN PARA FOR THAT
 SYSTEM TOO.
 PLEASE CORRECT THE WORD " TURBIDITY" IN
 POLLUTION PRE. NOTES D.
  
 RASIK, 805-6723

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-02-24 Cont ID  
Sent By mamini Date 2006-02-24 Time 09:23 Rev Time 1.00
Received By mamini Date 2006-02-24 Time 09:23 Sent To  
Notes
2006-02-24 00:00:00FAILED:
  
 1. PLEASE PROVIDE A COPY OF MDIFIED
 SFWMD.
 2. SHEET 2 OF 4, SEWER CONNECTION FOR
 THE PROPOSED BUILDING IS NOT CLEAR.
 3. POLLUTION PREVENTION PLANS MUST BE
 ADDED TO CIVIL PLANS, PLEASE REVISE.
 4. PLEASE SUBMIT CALCULATION FOR
 PERVIOUS, IMPERVIOUS AND BUILDING AREA
 FOR THIS IMPROVEMENT.
 5. SHEET 2 OF 4, CISTERN TANKS, ARE THEY
 CONNECTED TO ANY SYS., AND THE INTEND?
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2007-06-22 Cont ID  
Sent By mawillia Date 2007-06-22 Time 13:13 Rev Time 0.00
Received By mawillia Date 2007-06-22 Time 12:51 Sent To  
Notes
2007-06-22 13:12:24*****REVISION APPROVED*****
  
  
 THE COMMENTS OF 05/25/07 PLAN REVIEW HAVE BEEN
 ADDRESSED;PLAN SHEETSA2.1.1 THRUA2.3.3 WERE
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2007-06-12 Cont ID  
Sent By mwennerg Date 2007-06-12 Time 15:02 Rev Time 0.00
Received By mwennerg Date 2007-06-12 Time 15:02 Sent To  
Notes
2007-06-12 15:03:12BOLLARDS ADDED TO PARKING AREA PER J. SMITH.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2007-05-25 Cont ID  
Sent By mwennerg Date 2007-05-25 Time 10:23 Rev Time 0.00
Received By mwennerg Date 2007-05-25 Time 10:23 Sent To  
Notes
2007-05-25 10:28:46***DENIED***
  
 1) PLEASE SEE BUILDING COMMENTS #1&2 REGARDING
 REQUIREMENTS PER FS AND FAC.
  
 2) PLEASE PROVIDE MORE INFORMATION REGARDING PIPE
 RAILINGS.
  
 3) EXIT DOORS TO MEET THE REQUIREMENTS OF NFPA 101,
 CHAPTER 7.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLANS REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2006-10-23 Cont ID  
Sent By mwennerg Date 2006-10-23 Time 12:56 Rev Time 0.00
Received By mwennerg Date 2006-10-23 Time 12:56 Sent To  
Notes
2006-10-23 13:00:15***APPROVED***
  
 1) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE
 ALARM AND STANDPIPE SYSTEMS.
  
 2) TEMPORARY STANDPIPES REQUIRED WHEN BUILDING REACHES
 (3) STORIES OR (30') IN HEIGHT.
  
 3) FIRE DEPARTMENT VALVES ON STANDPIPES TO BE 2 1/2"- 1
 1/2" REDUCER WITH CHAINS.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-07-17 Cont ID  
Sent By mcarsill Date 2006-07-17 Time 14:36 Rev Time 0.00
Received By mcarsill Date 2006-07-17 Time 14:05 Sent To  
Notes
2006-07-17 00:00:001. LIFE SAFETY PLAN FOR THE FIRST LEVEL
 AND THE ELECTRICAL PLANS FOR THE FIRST
 LEVEL DO NOT CORRESPOND WITH EACH OTHER.
  
 DOOR ALSO APPEARS TO BE MISSING FROM
 STAIR # 3 ON THE ELECTRICAL FIRST FLOOR
 LEVEL.
  
 2. DOOR SWING IS INCORRECT ON PAGE
 A2.02.
  
 3. SEVERAL N/A RESPONSES ARE PRESENT ON
 THE COMMENT SHEET FROM KAMM CONSULTING.
 PLEASE PROVIDE MORE DETAILS TO FIRE
 RESCUE COMMENTS.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-03-10 Cont ID  
Sent By mwennerg Date 2006-03-10 Time 13:39 Rev Time 0.00
Received By mwennerg Date 2006-03-10 Time 13:39 Sent To  
Notes
2006-03-10 00:00:00******DENIED******
  
 1) KNOX BOX LOCKING CAPS ARE REQUIRED
 FOR FIRE DEPARTMENT CONNECTION.
  
 2) FIRE DEPARTMENT CONNECTION TO BE
 LOCATED NO FURTHER THAN 150' FROM A FIRE
 HYDRANT.
  
 3) SEPARATE SHOP DRAWINGS AND PERMITS
 REQUIRED FOR FIRE SPRINKLER AND FIRE
 ALARM SYSTEMS.
  
 4) 2A-10B,C RATED FIRE EXTINGUISHERS TO
 BE MOUNTED AT DISTANCE NOT TO EXCEED
 75'.
  
 5) PARKING GARAGE TO COMPLY WITH
 APPLICABLE BUILDING CODES AND NFPA 88A.
  
 6) WILL PROPOSED TENANT SPACE MEET
 SEPARATION REQUIREMENTS?
  
 7) PLEASE PROVIDE CLARIFICATION ON HOW
 AND WHERE PERSONS WILL BE EXITING THE
 BUILDING.
  
 8) THE STAIRWELL DOOR SWINGS ON UPPER
 FLOORS APPEAR TO SWING AGAINST DIRECTION
 OF TRAVEL.
  
 9) PANIC DOORS ARE MENTIONED ON SHT
 A-400, HOWEVER THIS IS NOT ILLUSTRATED
 IN THE DOOR SCHEDULE.
  
 10) THE COOLING TOWER TO COMPLY WITH
 NFPA 214.
  
 11) FIRE ALARM SYSTEM SHALL BE UL LISTED
 FOR CENTRAL STATION SERVICE.
  
 12) NO FIRE SPRINKLER LAY OUT HAS BEEN
 SUBMITTED WITH DRAWINGS.
  
 13) DUCT SMOKE DETECTOR SHALL INITIATE A
 GENERAL FIRE ALARM IN ACCORDANCE WITH
 LOCAL REQUIREMENTS.
  
 14) ARE SMOKE DETECTORS PLANNED FOR
 ELEVATOR RECALL?
  
 15) IT WOULD APPEAR THAT MORE
 AUDIBLE/VISUAL DEVICES ARE NEEDED ON
 UPPER FLOORS.
  
 16) EXIT LIGHTS TO BE MOUNTED AT
 DISTANCES NOT TO EXCEED 100'.
  
 17) PLEASE EXPLAIN WHY EXIT SIGNS DIRECT
 PERSONS INTO STAIWELLS ON FLOOR #1.
  
 18) PLEASE PROVIDE MANUFACTURER SPEC
 SHEETS FOR GENERATOR.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLANS REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2007-06-24 Cont ID  
Sent By adarroug Date 2007-06-24 Time 16:35 Rev Time 0.00
Received By adarroug Date 2007-06-24 Time 16:35 Sent To E
Notes
2007-06-24 16:35:25TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-06-04 Cont ID  
Sent By adarroug Date 2007-06-04 Time 08:44 Rev Time 0.00
Received By adarroug Date 2007-06-04 Time 08:44 Sent To  
Notes
2007-06-14 20:30:29 
  
 SENT TO R. MCDOUGAL FOR REVIEW.MAY NOT NEED FIRE
 REVIEW.
2007-06-04 08:44:27WAITING FOR "COMM" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-05-01 Cont ID  
Sent By adarroug Date 2007-05-01 Time 16:57 Rev Time 0.00
Received By adarroug Date 2007-05-01 Time 16:56 Sent To  
Notes
2007-05-10 08:50:40TO "COMM" BD#36
2007-05-01 16:57:13WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-04-18 Cont ID  
Sent By adarroug Date 2007-04-18 Time 13:33 Rev Time 0.00
Received By adarroug Date 2007-04-18 Time 13:33 Sent To  
Notes
2007-04-18 13:34:04TO "COMM" BD#47

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-03-29 Cont ID  
Sent By dpalmer Date 2007-03-29 Time 09:05 Rev Time 0.00
Received By dpalmer Date 2007-03-29 Time 09:05 Sent To B
Notes
2007-03-29 09:05:41TO RMCD'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-03-06 Cont ID  
Sent By adarroug Date 2007-03-06 Time 13:24 Rev Time 0.00
Received By adarroug Date 2007-03-06 Time 13:23 Sent To B
Notes
2007-03-06 13:23:31TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-02-28 Cont ID  
Sent By adarroug Date 2007-02-28 Time 10:22 Rev Time 0.00
Received By adarroug Date 2007-02-28 Time 10:22 Sent To B
Notes
2007-02-28 10:23:00TO "RMCDOUGAL" DESK/3 SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-02-27 Cont ID  
Sent By adarroug Date 2007-02-27 Time 18:04 Rev Time 0.00
Received By adarroug Date 2007-02-27 Time 18:04 Sent To B
Notes
2007-02-27 18:05:10TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-02-20 Cont ID  
Sent By adarroug Date 2007-02-20 Time 15:14 Rev Time 0.00
Received By adarroug Date 2007-02-20 Time 15:14 Sent To B
Notes
2007-02-20 15:14:46TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-02-12 Cont ID  
Sent By adarroug Date 2007-02-12 Time 15:26 Rev Time 0.00
Received By adarroug Date 2007-02-12 Time 15:26 Sent To B
Notes
2007-02-12 15:26:55TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-02-08 Cont ID  
Sent By adarroug Date 2007-02-08 Time 12:19 Rev Time 0.00
Received By adarroug Date 2007-02-08 Time 12:19 Sent To Z
Notes
2007-02-08 12:19:37TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-02-08 Cont ID  
Sent By adarroug Date 2007-02-08 Time 11:49 Rev Time 0.00
Received By adarroug Date 2007-02-08 Time 11:49 Sent To P
Notes
2007-02-08 11:49:35TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-01-09 Cont ID  
Sent By adarroug Date 2007-01-09 Time 17:46 Rev Time 0.00
Received By adarroug Date 2007-01-09 Time 17:46 Sent To P
Notes
2007-01-09 17:46:43TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-31 Cont ID  
Sent By adarroug Date 2006-10-31 Time 11:37 Rev Time 0.00
Received By adarroug Date 2006-10-31 Time 11:37 Sent To ENG
Notes
2006-10-31 11:37:28TO "RCHOKSHI" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-21 Cont ID  
Sent By adarroug Date 2006-09-21 Time 11:05 Rev Time 0.00
Received By adarroug Date 2006-09-21 Time 11:05 Sent To  
Notes
2006-10-05 00:00:00TO "COMM" BD#19/PLANS ON RACK
2006-09-21 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 17:03 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 17:03 Sent To  
Notes
2006-06-15 00:00:00ON COMM BOARD #14, 3-SETS OF PLANS ON
 COMM RACK.
2006-05-26 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-19 Cont ID  
Sent By adarroug Date 2006-05-19 Time 15:12 Rev Time 0.00
Received By adarroug Date 2006-05-19 Time 15:12 Sent To B
Notes
2006-05-19 00:00:00TO "RMCDOUGAL DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-18 Cont ID  
Sent By rmcdouga Date 2006-04-18 Time 14:19 Rev Time 0.00
Received By rmcdouga Date 2005-12-22 Time 16:29 Sent To  
Notes
2006-01-31 00:00:00TO "COMM" BD#39
2005-12-22 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-10-13 Cont ID  
Sent By pkrauss Date 2006-10-13 Time 14:27 Rev Time 0.00
Received By pkrauss Date 2006-10-13 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-28 Cont ID  
Sent By pkrauss Date 2006-07-28 Time 14:57 Rev Time 0.00
Received By pkrauss Date 2006-07-28 Time 14:39 Sent To  
Notes
2006-07-28 00:00:00DENIED:2004 FMC
 RESPONSE TO COMMENTS DATED 2-21-06:
  
 COMMENT 1:OK
 COMMENT 2:OK
  
 3.RESPONSE INDICATES ELEVATION HAS
 BEEN PROVIDED FOR ALL INTAKE & RELIEF
 LOUVERS.PLEASE NOTE, COMMENT REQUESTED
 THE ELEVATION BE PROVIDED FOR THE
 TERMINATION OF EF-1.TERMINATION TO
 EF-1 IS TO THE INTERIOR OF THE PARKING
 GARAGE & APPEARS TO BE DISCHARGING ONTO
 WALKWAY.SHOW COMPLIANCE WITH 2004 FMC
 401.5.2 & 501.2.
  
 COMMENT 4:OK
  
 ***************NEW COMMENT*************
  
 5.PLEASE INDICATE WHAT WILL BE IN
 STORAGE AREA.PLEASE NOTE THE
 TERMINATION OF EXHAUST FROM EF-2, 3, 4,
 5, & 6 ALL TEMRINATE WITHIN 10 FT OF THE
 DOOR.PLEASE CLARIFY.
  
 PLEASE PROVIDE ADDITIONAL INFORMAITON
 FOR THE EMERGENCY GENERATOR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By pkrauss Date 2006-02-21 Time 15:04 Rev Time 0.00
Received By pkrauss Date 2006-02-21 Time 15:04 Sent To  
Notes
2006-02-21 00:00:00DENIED:2004 FLORIDA BUILDING CODE
  
 1.PER CITY AMENDMENTS TO THE 2004
 FLORIDA BUILDING CODE 106.1.3, BUILDING
 PLANS SHALL BE DRAWN TO A MINIMUM OF 1/8
 INCH SCALE.PLANS INDICATE 3/32.
  
 2.PLAN SHEET M2.1 INDICATES EXHAUST
 FROM THE ELEVATOR EQUIPMENT ROOM BUT
 DOES NOT INDICATE MAKE-UP AIR.PLEASE
 SHOW COMPLIANCE WITH 2004 FMC 403.1.
  
 3.PLEASE PROVIDE ELEVATION OF THE
 DISCHARGE FROM EF-1.PLEASE NOTE,
 EXHAUST SHALL TERMINATE AS TO NOT CREATE
 A NUISANCE.
  
 4.PLEASE INDICATE MEANS OF VENTILATION
 INTO ALL THE MECHANICAL ROOM AREAS.
 SHOW COMPLIANCE WITH 2004 FMC 401.2 &
 401.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-03-05 Cont ID  
Sent By kstevens Date 2007-03-05 Time 14:37 Rev Time 0.00
Received By kstevens Date 2007-03-05 Time 14:37 Sent To  
Notes
2007-03-05 14:38:49REVISION OK - SHEETS P0.1, P2.4, P2.5, P2.6, & P5.2.
 --ADDED TRENCH DRAINS AT STAIRS AND RELATED STORM
 PIPING.

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-01-22 Cont ID  
Sent By kstevens Date 2007-01-22 Time 15:57 Rev Time 0.00
Received By kstevens Date 2007-01-22 Time 15:57 Sent To  
Notes
2007-01-22 15:58:31REVISION OK - SHTS P3.4 & P6.2 DELETED HOSE BIBBS &
 WATER LINE SUPPLY FOR HOSE BIBBS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-10-26 Cont ID  
Sent By pschmitz Date 2006-10-26 Time 13:33 Rev Time 0.00
Received By pschmitz Date 2006-10-26 Time 13:33 Sent To  
Notes
2006-10-26 13:34:40RE-SUB
 NOTES FROM 7-8-06

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-08 Cont ID  
Sent By pschmitz Date 2006-07-08 Time 09:27 Rev Time 0.00
Received By pschmitz Date 2006-07-08 Time 09:27 Sent To  
Notes
2006-07-08 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 DENIED
 1) SHT P6.2 WATER RISER HOSE BIBBS
 SEC 606.2 LOCATION OF SHUTOFF VALVES.
 SHUTOFF VALVES SHALL BE INSTALLED IN THE
 FOLLOWING LOCATIONS:
 2. ON THE WATER SUPPLY PIPE TO EACH
 SILLCOCK IN OTHER THAN ONE- AND
 TWO-FAMILY RESIDENTIAL OCCUPANCIES.
  
 2) SHT P6.2 SEC 608.15.4.2
 HOSE CONNECTIONS.
 SILLCOCKS, HOSE BIBBS, WALL HYDRANTS AND
 OTHER OPENINGS WITH A HOSE CONNECTION
 SHALL BE PROTECTED BY AN
 ATMOSPHERIC-TYPE OR PRESSURE-TYPE VACUUM
 BREAKER OR A PERMANENTLY ATTACHED HOSE
 CONNECTION VACUUM BREAER.
  
 3)PLUMBING RESPONSE:DATED MAY 19, 2006
 REFERENCE TO SHEET P7.2 DEPICTS A
 CISTERN PIPING DIAGRAM.
 NOT INCLUDE WITH THIS SET OF PLANS.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-04 Cont ID  
Sent By pschmitz Date 2006-03-04 Time 15:18 Rev Time 0.00
Received By pschmitz Date 2006-03-04 Time 14:46 Sent To  
Notes
2006-03-04 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 DENIED
 1) DISCRIPTION OF WORK ON PERMIT
 APPLICATION, MULTI STORY PARKING GARAGE.
 SHT. P2.4,P3.4, P6.2,P7.2PLEASE SHOW
 CLEARLY HOW THIS IS RELATED TO THE
 PARKING GARAGE CONSTRUCTION.
 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL. ELECTRONIC MEDIA DOUCMENTS ARE
 PERMITTED TO BE SUBMITTED WHEN APPROVED
 BY THE BUILDING OFFICAL. CONSTRUCTION
 DOUCMENTS SHALL BE OF SUFFICENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT ITWILL CONFORM TOTHE
 PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS
 AS DETERMINED BY THE BUILDING OFFICAL (
 SEE ALSO SECTION 106.3.5)
  
 2) SHT L-1 REFERENCES IRRIGATION.
 PLEASE PROVIDE IRRIGATIONS PLANS.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
 END OF COMMENTS, QUESTIONS 561-805-6692
  

Review Stop Z ZONING
Rev No 8 Status P Date 2007-06-22 Cont ID  
Sent By jroach Date 2007-06-22 Time 08:08 Rev Time 0.00
Received By jroach Date 2007-06-22 Time 08:08 Sent To B
Notes
2007-06-22 08:10:05***PROVISO***
  
 ALL SPACES LABELED AS COMPACT ON THE PLANS SHALL BE
 SIGNED AS SUCH IN THE FIELD.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 7 Status F Date 2007-05-15 Cont ID  
Sent By jroach Date 2007-05-15 Time 11:30 Rev Time 0.00
Received By jroach Date 2007-05-15 Time 08:08 Sent To  
Notes
2007-05-15 11:30:25***FAILED***
  
 IT APPEARS THAT REVISIONS WERE MADE TO THE PARKING
 STRIPING AND CONFIGURATION SINCE LAST APPROVED BY
 ZONING.THE SPACE IN THE FAR SOUTHEAST CORNER OF THE
 MID AND UPPER LEVELS SHOULD BE DESIGNATED COMPACT AS IT
 IS LESS THAN 8 FEET 6 INCHES WIDE.IN ORDER TO VERIFY
 THAT THE PARKING COUNTS ARE STILL ACCURATE, DESPITE
 THESE CHANGES, PLEASE PROVIDE A COPY OF THE SHEET THAT
 ACCURATELY SHOWS THE PARKING DISTRIBUTION (REQUIRED VS.
 PROVIDED, HANDICAP REQUIRED VS. PROVIDED, COMPACT
 PROVIDED, ETC.).
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 6 Status F Date 2007-04-30 Cont ID  
Sent By jroach Date 2007-04-30 Time 23:16 Rev Time 0.00
Received By jroach Date 2007-04-30 Time 23:16 Sent To  
Notes
2007-04-30 23:19:18***FAILED***
  
 IT APPEARS THAT REVISIONS WERE MADE TO THE PARKING
 STRIPING AND CONFIGURATION SINCE LAST APPROVED BY
 ZONING.THE SPACE IN THE FAR SOUTHEAST CORNER OF THE
 MID AND UPPER LEVELS SHOULD BE DESIGNATED COMPACT AS IT
 IS LESS THAN 8 FEET 6 INCHES WIDE.IN ORDER TO VERIFY
 THAT THE PARKING COUNTS ARE STILL ACCURATE, DESPITE
 THESE CHANGES, PLEASE PROVIDE A COPY OF THE SHEET THAT
 ACCURATELY SHOWS THE PARKING DISTRIBUTION (REQUIRED VS.
 PROVIDED, HANDICAP REQUIRED VS. PROVIDED, COMPACT
 PROVIDED, ETC.).
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 5 Status P Date 2007-02-15 Cont ID  
Sent By jroach Date 2007-02-15 Time 13:33 Rev Time 0.00
Received By jroach Date 2007-02-15 Time 13:33 Sent To  
Notes
2007-02-15 13:33:46***LANDSCAPE REVISION PASSED***

Review Stop Z ZONING
Rev No 4 Status P Date 2006-10-31 Cont ID  
Sent By jroach Date 2006-10-31 Time 14:33 Rev Time 0.00
Received By jroach Date 2006-10-31 Time 14:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2006-10-25 Cont ID  
Sent By jroach Date 2006-10-25 Time 10:46 Rev Time 0.00
Received By jroach Date 2006-10-25 Time 10:46 Sent To  
Notes
2006-10-25 11:00:31***FAILED***
  
 1)DETAIL 2 ON SHEET A1.1.0 FOR THE SCREEN WALL SHOWS
 8 FEET IN HEIGHT.THE SITE PLANS ON SHEETS A1.1.0 AND
 A1.1.1 INDICATE 6 FEET.PLEASE MAKE CONSISTENT.
  
 2) NUMBER OF PARKING SPACES INDICATED IS INCORRECT.
 THE FOLLOWING WAS DRAWN ON THE FLOOR PLANS...PLEASE
 ADJUST ALL PARKING COUNTS ACCORDINGLY:
  
 1ST LEVEL - 91 (TOTAL) - 44 (REGULAR) - 43 (COMPACT) -
 4 (ACCESSIBLE)***2 SPACES ON THE NORTH END ARE SHOWN
 AS REGULAR SPACES, HOWEVER, NEED TO BE DESIGNATED AS
 COMPACT***
  
 2ND THRU 4TH LEVEL - 107 (TOTAL) - 64 (REGULAR) - 41
 (COMPACT) - 2 (ACCESSIBLE)***2 SPACES ON THE NORTH
 END ARE SHOWN AS REGULAR SPACES, HOWEVER, NEED TO BE
 DESIGNATED AS COMPACT***
  
 5TH LEVEL - 88 (TOTAL) - 56 (REGULAR) - 30 (COMPACT) -
 2 (ACCESSIBLE)***5 SPACES ON THE NORTH END ARE SHOWN
 AS REGULAR SPACES, HOWEVER, NEED TO BE DESIGNATED AS
 COMPACT***
  
 3)XERISCAPE TABLE, WITH A MINIMUM OF 30 POINTS, SHALL
 BE PROVIDED ON THE LANDSCAPE PLANS...IT WAS REMOVED
 UPON SUBMISSION OF REVISED PLANS.
  
 4) SIGNAGE SHALL BE PROVIDED AT EACH COMPACT SPACE
 INDICATING SUCH.PLEASE MAKE A NOTE AND/OR ADD A
 DETAIL.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR
 PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-09 Cont ID  
Sent By jroach Date 2006-07-09 Time 14:46 Rev Time 0.00
Received By jroach Date 2006-07-09 Time 14:46 Sent To  
Notes
2006-07-09 00:00:007/9/06 ***FAILED***
  
 1) THE NORTH WALL ON THE SITE PLANS
 APPEARS TO BE IN THE INCORRECT
 LOCATION...IT IMPEDES WITH THE WALKING
 PATH, NORTHWEST STAIRS, ETC.
  
 2) PROVIDE DETAILS REGARDING THE
 CHILLER/COOLING TOWERS.WHY ARE THESE
 NOW BEING PLACED AT GRADE?DETAILS,
 SUCH AS HEIGHT, NEED TO BE PROVIDED AS
 WELL AS SUFFICIENT SCREENING (I.E. SOLID
 WALL OF ADEQUATE HEIGHT WITH
 SHRUBS/HEDGES).
  
 3) PROVIDE DETAILS REGARDING THE
 PROPOSED GENERATOR, SUCH AS THE HEIGHT,
 TO ENSURE THAT THE PROPOSED 6 FOOT
 SCREEN WALL IS SUFFICIENT.
  
 4) THE NUMBER OF PARKING SPACES
 INDICATED ON THE SITE PLAN DATA TABLE
 DOES NOT CORRESPOND WITH WHAT IS DRAWN
 ON THE FLOOR PLANS.THERE APPEARED TO
 BE 491 SPACES ON THE FLOOR PLANS (300
 REGULAR, 179 COMPACT, AND 12
 ACCESSIBLE).
  
 5) PROVIDE AN ENLARGEMENT OF THE DOUBLE
 STRIPING FOR THE PARKING SPACES.THE
 DETAIL PROVIDED APPEARS INCORRECT.
 THERE SHOULD BE 1 FOOT 4 INCHES FROM THE
 CL OF THE STRIPE TO THE CL OF THE STRIPE
 WITH 12 INCHES FROM INSIDE OF THE STRIPE
 TO INSIDE OF THE STRIPE.REFER TO
 SECTION 94-485 OF THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS FOR AN EXAMPLE.THE
 HANDICAP STRIPING IS INCORRECT IN REGARD
 TO THIS AS WELL.
  
 6) PROVIDE A STRIPING DETAIL THAT SHOWS
 HOW THE SUPPORT COLUMNS RELATE TO THE
 PROPOSED STRIPING.WHAT ARE THE
 DIMENSIONS OF THE COLUMNS?WHERE DO
 THEY FALL IN THE STRIPING?ETC.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By jroach Date 2006-02-21 Time 09:11 Rev Time 0.00
Received By jroach Date 2006-02-21 Time 09:11 Sent To  
Notes
2006-02-21 00:00:002/21/2006 ***FAILED***
  
 1) ON THE SITE PLANS, PLEASE INDICATE
 THE LIMITS OF SITE IMPROVEMENTS
 ASSOCIATED WITH THIS PERMIT.
  
 2) MORE DETAIL SHALL BE PROVIDED
 REGARDING THE COLUMNS THAT ARE LOCATED
 BETWEEN COMPACT SPACES ON THE FIRST
 FLOOR.PLEASE PROVIDE A DETAIL SHOWING
 HOW THE COLUMN RELATES TO THE STRIPING,
 ETC.IF THE COLUMN FALLS COMPLETELY
 WITHIN THE DOUBLE-STRIPE, THE SPACE MAY
 REMAIN.IF IT INTERFERES IN ANY WAY
 WITH THE STALL, THE SPACE SHALL BE
 REMOVED.
  
 3) IF THE GENERATORS ARE NOT A PART OF
 THE PERMIT APPLICATION, REMOVE THEM FROM
 THE PLANS OR MAKE NOTE THAT THEY WILL BE
 SUBMITTED UNDER SEPARATE PERMIT.IF
 THEY ARE A PART OF THE PERMIT PACKAGE,
 APPROPRIATE SCREENING SHALL BE PROVIDED
 (WALL, HEDGE, ETC.).
  
 4) LANDSCAPE PLANS SHALL BE SEALED WITH
 AN ORIGINAL SIGNATURE, NOT A COPY.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH
 AT (561) 822-1435.
  
 LANDSCAPE COMMENTS:
  
 1) REFER TO SET #1, SHEET L-4 FOR
 COMMENTS REGARDING PLANTING
 DETAILS/DIAGRAMS.
  
 QUESTIONS/COMMENTS, CONTACT ALAN
 BARATTA, LANDSCAPE PLANNER AT (561)
 822-1435.
  