2006-02-08 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 05120367 |
| ADD: 314 10TH ST |
| CONT: KENNEDY CONTRACTORS |
| TEL: (561)307-1461 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| |
| 1) PROVIDE NOC RECORDED WITH THE CLERK |
| OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| NOTE ONCE NOC IS RECORDED AT THE CLERK |
| OF THE COURT, WORK MUST START WITHIN 90 |
| DAYS OF RECORDING OTHERWISE NOC MUST BE |
| RE-RECORDED. FL SS 71.13(2) |
| |
| 2A) SCOPE OF WORK IS LOW, WE WILL |
| RE-EVALUATEUSING MARSHALL & SWIFT IF |
| THE VALUE IS NOT INCREASED. |
| |
| 2B) THE PERMIT APPLICATION DESCRIPTION |
| INDICATES CHANGE OF USE, IT APPEARS THAT |
| AN ADDITION 918 SQ FT IS ALSO BEING |
| ADDED. |
| |
| 2C) NOTHING IN THIS PERMIT INDICATES |
| THAT THE REAR BUILDING IS UNDER GOING A |
| CHANGE OF OCCUPANCY? |
| |
| 3) IT APPEARS THAT THE OWNER/ CONTRACTOR |
| HAS DRAWN UP THE PLANS, FL S S |
| 481.229(1)(C) WHEN THE SCOPE OF WORK IS |
| UNDER $25,000.00 AN ARCHITECT IS NOT |
| REQUIRED TO DRAW PLANS, OTHERWISE A |
| DESIGN PROFESSIONAL WILL BE REQUIRED.SEE |
| FL S S |
| 489.229 EXCEPTIONS, EXEMPTIONS FROM |
| LICENSURE. |
| |
| 4) 2004 EXISTING BUILDINGS CHAPTER 8, |
| CHANE IN OCCUPANCIES 801.3A CERTIFICATE |
| OF OCCUPANCY SHALL BE ISSUED WHERE A |
| CHANGE OF OCCUPANCY OCCURS THAT RESULTS |
| IN BEING CLASSIFIED AS A DIFFERENT |
| OCCUPANCY CLASSIFICATION AS DETERMINED |
| BY THE FLORIDA BUILDING CODE, BUILDING. |
| |
| PLANS ARE TO COMPLY WITH THE PROVISIONS |
| OF CHAPTER 8 OF EXISTING BUILDING 2004 |
| CHAPTER 9 FOR ADDITIONS AND THE 2004 |
| BUILDING CODE FOR COMMERCIAL AS WELL AS |
| CHAPTER 11 OF THE 2004 FBC. |
| |
| 5)2004 EXISTING BUILDING 806.1, |
| ACCESSIBILITY IN PORTIONS OF BUILDINGS |
| UNDER GOING A CHANGE OF OCCUPANCY |
| CLASSIFICATION SHALL COMPLY WITH CHAPTER |
| 11 OF THE FLORIDA BUILDING CODE. |
| |
| 5A) AN ACCESSIBLE ROUTE TO THE RIGHT OF |
| |
| WAY. |
| |
| 5B) 11-4.6.1 PARKING AND PASSENGER |
| LOADING ZONES. |
| |
| 5C) ACCESSIBLE RAMPS: |
| 11-4.8.2 SLOPE & RISE. THE LEAST |
| POSSIBLE SLOPE SHALL BE USED FOR ANY |
| RAMP. THE MAXIMUM SLOPE FOR A RAMP IN |
| NEW CONSTRUCTION SHALL BE 1 TO 12. THE |
| MAXIMUM RISE FOR RUN SHALL BE 30" (SEE |
| FIGURE 16). |
| 11-4.8.3. CLEAR WIDTH. THE MINIMUM |
| CLEAR WIDTH OF A RAMP SHALL BE 36". |
| EXCEPTION: RAMPS THAT ARE PART OF A |
| REQUIRED MEANS OF EGRESS SHALL NOT BE |
| LESS THAN 44 INCHES WIDE. |
| 11-4.8.4.(2) LANDINGS. ALL LANDINGS |
| ON RAMPS SHALL NOT BE LESS THAN 60" |
| CLEAR, & THE BOTTOM OF EACH RAMP SHALL |
| HAVE NOT LESS THAN 72" OF STRAIGHT & |
| LEVEL CLEARENCE. |
| 11-4.8.4(3) IF RAMPS CHANGE DIREC- |
| TION AT LANDINGS, THE MINIMUM LANDING |
| SIZE SHALL BE 60" X 60". |
| 11.4.8.5. HANDRAILS: IF A RAMP HAS |
| A RISE GREATER THAN 6" OR A HORIZONTAL |
| PROJECTION GREATER THAN 72", THEN IT |
| SHALL HAVE HANDRAILS ON BOTH SIDES. |
| |
| 5D)11-4.21.1 GENERAL. |
| ACCESSIBLE SHOWER STALLS SHALL COMPLY |
| WITH SECTION 11-4.21 . |
| 11-4.21.2 SIZE AND CLEARANCES. |
| EXCEPT AS SPECIFIED IN SECTION 11-9.1.2 |
| , SHOWER STALL SIZE AND CLEAR FLOOR |
| SPACE SHALL COMPLY WITH FIGURE 11-35 (A) |
| OR FIGURE 11-35 (B). THE SHOWER STALL IN |
| FIGURE 11-35 (A) SHALL BE 36 INCHES BY |
| 36 INCHES (915 MM BY 915 MM). SHOWER |
| STALLS REQUIRED BY SECTION 11-9.1.2 |
| SHALL COMPLY WITH FIGURE 11-57 (A) OR |
| FIGURE 11-57 (B). THE SHOWER STALL IN |
| FIGURE 11-35 (B) WILL FIT INTO THE SPACE |
| REQUIRED FOR A BATHTUB. |
| |
| 11-4.21.3 SEAT. |
| A SEAT SHALL BE PROVIDED IN SHOWER |
| STALLS 36 INCHES BY 36 INCHES (915 MM BY |
| 915 MM) AND SHALL BE AS SHOWN IN FIGURE |
| 11-36 . THE SEAT SHALL BE MOUNTED 17 |
| INCHES TO 19 INCHES (430 MM TO 485 MM) |
| FROM THE BATHROOM FLOOR AND SHALL EXTEND |
| THE FULL DEPTH OF THE STALL. IN A |
| 36-INCH BY 36-INCH (915 MM BY 915 MM) |
| SHOWER STALL, THE SEAT SHALL BE ON THE |
| WALL OPPOSITE THE CONTROLS. WHERE A |
| FIXED SEAT IS PROVIDED IN A 30-INCH BY |
| 60-INCH MINIMUM (760 MM BY 1525 MM) |
| SHOWER STALL, IT SHALL BE A FOLDING TYPE |
| AND SHALL BE MOUNTED ON THE WALL |
| ADJACENT TO THE CONTROLS AS SHOWN IN |
| FIGURE 11-57 . THE STRUCTURAL STRENGTH |
| OF SEATS AND THEIR ATTACHMENTS SHALL |
| COMPLY WITH SECTION 11-4.26.3 . |
| 11-4.21.4 GRAB BARS. |
| GRAB BARS COMPLYING WITH SECTION 11-4.26 |
| SHALL BE PROVIDED AS SHOWN IN FIGURE |
| 11-37 . |
| 11-4.21.5 CONTROLS. |
| FAUCETS AND OTHER CONTROLS COMPLYING |
| WITH SECTION 11-4.27.4 SHALL BE LOCATED |
| AS SHOWN IN FIGURE 11-37 . IN SHOWER |
| STALLS 36 INCHES BY 36 INCHES (915 MM BY |
| 915 MM), ALL CONTROLS, FAUCETS, AND THE |
| SHOWER UNIT SHALL BE MOUNTED ON THE SIDE |
| WALL OPPOSITE THE SEAT. |
| 11-4.21.6 SHOWER UNIT. |
| A SHOWER SPRAY UNIT WITH A HOSE AT LEAST |
| 60 INCHES (1525 MM) LONG THAT CAN BE |
| USED BOTH AS A FIXED SHOWER HEAD AND AS |
| A HAND-HELD SHOWER SHALL BE PROVIDED. |
| EXCEPTION: IN UNMONITORED FACILITIES |
| WHERE VANDALISM IS A CONSIDERATION, A |
| FIXED SHOWER HEAD MOUNTED AT 48 INCHES |
| (1220 MM) ABOVE THE SHOWER FLOOR MAY BE |
| USED IN LIEU OF A HAND-HELD SHOWER HEAD. |
| |
| 11-4.21.7 CURBS. |
| IF PROVIDED, CURBS IN SHOWER STALLS 36 |
| INCHES BY 36 INCHES (915 MM BY 915 MM) |
| SHALL BE NO HIGHER THAN ? INCH (13 MM). |
| SHOWER STALLS THAT ARE 30 INCHES BY 60 |
| INCHES (760 MM BY 1525 MM) MINIMUM SHALL |
| NOT HAVE CURBS. |
| |
| 5D) 11-4.24.2 SINKS, HEIGHT. SINKS SHALL |
| BE MOUNTED WITH THE COUNTER NO HIGHER |
| THAN 34" ABOVE THE FINISH FLOOR. |
| 11-4.24.3 KNEE CLEARENCE THAT IS AT |
| LEAST 27" HIGH 30" WIDE, AND 19" DEEP |
| SHALL BE PROVIDED UNDERNEATH SINKS. |
| |
| 6) 2004 ENERGY CODE 13-101.3.2 BUILDINGS |
| HAVING A CHANGE OF OCCUPANCY THAT WERE |
| PERMITTED AFTER MARCH 15, 1979, SHALL |
| COMPLY WITH THE REQUIREMENTS OF |
| SUBCHAPTER 13-4 FOR COMMERCIAL |
| APPLICATIONS AND MULTIPLE-FAMILY |
| RESIDENTIAL BUILDINGS GREATER THAN THREE |
| STORIES OR SUBCHAPTER 13-6 FOR |
| RESIDENTIAL APPLICATIONS OF THREE |
| STORIES OR LESS. WHERE THE EFFICIENCY OF |
| A BUILDING COMPONENT IS UNKNOWN, IT |
| SHALL BE DETERMINED IN ACCORDANCE WITH |
| THE CRITERIA SPECIFIED IN SECTION |
| 101.4.2.1 . |
| |
| 7) 110.2* W. P. B. ADMINISTRATIVE CODE, |
| INFORMATION THAT IS REQUIRED FOR RECORD |
| KEEPING & FOR CERTIFICATE OF OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| |
| 8) 2004 EXISTING BUILDING CHANGE OF |
| OCCUPANCY 812.1 COMPLIANCE WITH CHAPTER |
| 7 THE OCCUPANCY CLASSIFICATION OF AN |
| EXISTING BUILDING MAY BE CHANGED, |
| PROVIDED THAT THE BUILDING MEETS ALL THE |
| REQUIREMENTS OF CHAPTER7 APPLIED |
| THROUGHOUT THE BUILDING FOR THE NEW |
| OCCUPANCY GROUP AND COMPLIES WITH THE |
| REQUIREMENT S OF SECTION 802 THROUGH |
| 812.SEE : |
| 705 MEANS OF EGRESS / FLORIDA BUILDING |
| CODE |
| 706 ACCESSIBILITY CHAPTER 11 2004 FBC |
| 707 STRUCTURAL: |
| 707.5.1 EVALUATION &ANALYSIS FBC |
| BUILDING FOR WIND LOADING |
| 1609.1.4.1 BUILDING WITH OPENINGS. |
| 1609.1.4.WHERE GLAZING IS ASSUMED TO BE |
| AN OPENING IN ACCORDANCE WITH SECTION |
| 1609.1.4 , THE BUILDING SHALL BE |
| EVALUATED TO DETERMINE IF THE OPENINGS |
| ARE OF SUFFICIENT AREA TO CONSTITUTE AN |
| OPEN OR PARTIALLY ENCLOSED BUILDING AS |
| DEFINED IN SECTION 1609.2 . OPEN AND |
| PARTIALLY ENCLOSED BUILDINGS SHALL BE |
| DESIGNED IN ACCORDANCE WITH THE |
| APPLICABLE PROVISIONS OF ASCE 7. |
| |
| 1609.1.4 PROTECTION OF OPENINGS. |
| IN WIND-BORNE DEBRIS REGIONS, EXTERIOR |
| GLAZING THAT RECEIVES POSITIVE PRESSURE |
| IN THE LOWER 60 FEET (18.3 M) IN |
| BUILDINGS SHALL BE ASSUMED TO BE |
| OPENINGS AND THE BALANCE OF GLAZED |
| OPENINGS IN THE REST OF THE BUILDING |
| SHALL BE ASSUMED TO BE ZERO UNLESS SUCH |
| GLAZING THAT RECEIVES POSITIVE PRESSURE |
| IS IMPACT RESISTANT OR PROTECTED WITH AN |
| IMPACT RESISTANT COVERING MEETING THE |
| REQUIREMENTS OF SSTD 12, ASTM E 1886 AND |
| ASTM E 1996, OR MIAMI-DADE TAS 201, 202 |
| AND 203 REFERENCED THEREIN AS FOLLOWS: |
| 1.GLAZED OPENINGS LOCATED WITHIN 30 |
| FEET (9.1 M) OF GRADE SHALL MEET THE |
| REQUIREMENTS OF THE LARGE MISSILE TEST. |
| |
| 1609.1.3 ANCHORAGE AGAINST OVERTURNING, |
| UPLIFT AND SLIDING. |
| STRUCTURAL MEMBERS AND SYSTEMS AND |
| COMPONENTS AND CLADDING IN A BUILDING OR |
| STRUCTURE SHALL BE ANCHORED TO RESIST |
| WIND-INDUCED OVERTURNING, UPLIFT AND |
| SLIDING AND TO PROVIDE CONTINUOUS LOAD |
| PATHS FOR THESE FORCES TO THE |
| FOUNDATION. WHERE A PORTION OF THE |
| RESISTANCE TO THESE FORCES IS PROVIDED |
| BY DEAD LOAD, THE DEAD LOAD, INCLUDING |
| THE WEIGHT OF SOILS AND FOUNDATIONS, |
| SHALL BE TAKEN AS THE MINIMUM DEAD LOAD |
| LIKELY TO BE IN PLACE DURING A DESIGN |
| WIND EVENT. WHERE THE ALTERNATE BASIC |
| LOAD COMBINATIONS OF SECTION 1605.3.2 |
| ARE USED, ONLY TWO-THIRDS OF THE MINIMUM |
| DEAD LOAD LIKELY TO BE IN PLACE DURING A |
| DESIGN WIND EVENT SHALL BE USED. |
| FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) WINDOWS, |
| B) DOORS |
| C) MULLIONS |
| D) LINTELS |
| E) ROOFING ASSEMBLIES |
| |
| 9) 106.3.3* PRODUCT APPROVALS- 2004 |
| THOSE PRODUCTS THAT ARE RGULATED BY DCA |
| RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITTING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| 10)2004 EXISTING BUILD,707.6 GRAVITY |
| LOADS IS INCREASED ON THE ROOF OR FLOOR |
| OF A BUILDING ALL STRUCTURAL MEMBERS |
| AFFECTED BY SUCH INCREASE SHALL MEET THE |
| GRAVITY LOAD REQUIREMENTS OF THE 2004 |
| FBC, BUILDING. |
| |
| 11)FL. BLD CODE 1603.1.4 THE FOLLOWING |
| INFORMATION RELATED TO WIND SHALL BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| 12) SHEET S-2: |
| |
| 12A) PLANS DO NOT IDENTIFY THE STEEL C |
| JOIST AS PER KNOWN MEMBER DEPTH, TYPE OF |
| SECTION,( 4 ALPHA CHARACTERS ARE USED |
| ACCORDING TO SHAPE), FLANGE WIDTH & |
| MATERIAL THICKNESS. |
| 1604.3.3 STEEL. |
| PROVIDE THE ALLOWABLE DEFLECTION LIMITS |
| AS INDICATED IN FBC BUILDINGTABLE 1604.3 |
| |
| THE DEFLECTION OF STEEL STRUCTURAL |
| MEMBERS SHALL NOT EXCEED THAT PERMITTED |
| BY AISC LRFD, AISC HSS, AISC 335, AISI |
| -NASPEC, AISI-GENERAL, AISI-TRUSS, ASCE |
| 3, ASCE 8-SSD-LRFD/ASD, AND THE STANDARD |
| SPECIFICATIONS OF SJI STANDARD |
| SPECIFICATIONS, LOAD TABLES AND WEIGHT |
| TABLES FOR STEEL JOISTS AND JOIST |
| GIRDERS AS APPLICABLE. |
| |
| 12B) 1603.4 OCCUPANCY PERMITS FOR |
| CHANGED LOADS. CONSTRUCTION DOCUMENTS |
| FOR OTHER THAN RESIDENTIAL BUILDINGS |
| FILED WITH THE BUILDING OFFICIAL WITH |
| APPLICATIONS FOR PERMITS SHALL SHOW ON |
| EACH DRAWING THE LIVE LOADS PER SQUARE |
| FOOT (M 2 ) OF AREA COVERED FOR WHICH |
| THE BUILDING IS DESIGNED. OCCUPANCY |
| PERMITS FOR BUILDINGS HEREAFTER ERECTED |
| SHALL NOT BE ISSUED UNTIL THE FLOOR LOAD |
| SIGNS, REQUIRED BY SECTION 1603.3 , HAVE |
| BEEN INSTALLED. |
| |
| 12C) STATE DEAD AND LIVE LOADS TO BE |
| IMPOSED ON BOTH THE FLOOR JOIST AND ROOF |
| |
| JOIST WITH ATTACHED CEILING. |
| |
| 12D) PLANS INDICATE A DROPED CEILING |
| ATTACHED TO SELF SURRING HI-HAT CHANNEL |
| BUT NO INFORMATION AS TO WHAT THE HI-HAT |
| IS TO BE HUNG FROM, BLCK IRON AND |
| HANGING WIRE? IS THE HI-HAT TO BE TIED |
| WITH WIRE OR SCREWED/ |
| |
| 12E) BOTH THE FLOOR & CEILING JOIST SHOW |
| A ANGLE ANCHORED TO THE BLOCK WALL, NO |
| INFORMATION AS TO HOW THE ANGLE IS TO BE |
| |
| ANCHORED? |
| |
| 12F) NO INFORMATION ON THE ANGLE, STEEL |
| OR ALUM? SIZE NOR WEIGHT PER FT? PLANS |
| ALSO MISS THE CONNECTION BETWEEN THE |
| ANGLE AND STEEL JOIST, NO BOLT |
| INFORMATION IF WASHERS WILL BE REQUIRED? |
| PLANS DO NOT IDENTIFY LOADS TO BE |
| RESISTED, UPLIFT, GRAVITY, NOR |
| HORIZONTAL LOADS OR COMBINATION OF |
| LOADS. |
| |
| 12G) PLANS DO NOT PROVIDE A PROFILE OF |
| WINDOWS BUCKS, NOR ATTACHMENT? |
| 1714.5.4.2 MASONRY, CONCRETE OR OTHER |
| STRUCTURAL SUBSTRATE. |
| WHERE THE WOOD SHIM OR BUCK THICKNESS IS |
| LESS THAN 1 1 / 2 INCHES (38 MM), WINDOW |
| AND DOOR ASSEMBLIES SHALL BE ANCHORED |
| THROUGH THE MAIN FRAME OR BY JAMB CLIP |
| OR SUBFRAME SYSTEM, IN ACCORDANCE WITH |
| THE MANUFACTURER?S PUBLISHED |
| INSTALLATION INSTRUCTIONS. ANCHORS SHALL |
| BE SECURELY FASTENED DIRECTLY INTO THE |
| MASONRY, CONCRETE OR OTHER STRUCTURAL |
| SUBSTRATE MATERIAL. UNLESS OTHERWISE |
| TESTED, BUCKS SHALL EXTEND BEYOND THE |
| INTERIOR FACE OF THE WINDOW OR DOOR |
| FRAME SUCH THAT FULL SUPPORT OF THE |
| FRAME IS PROVIDED. SHIMS SHALL BE MADE |
| FROM MATERIALS CAPABLE OF SUSTAINING |
| APPLICABLE LOADS, LOCATED AND APPLIED IN |
| A THICKNESS CAPABLE OF SUSTAINING |
| APPLICABLE LOADS. ANCHORS SHALL BE |
| PROVIDED TO TRANSFER LOAD FROM THE |
| WINDOW OR DOOR FRAME TO THE ROUGH |
| OPENING SUBSTRATE. |
| WHERE THE WOOD BUCK THICKNESS IS 1 1 / 2 |
| INCHES (38 MM) OR GREATER, THE BUCK |
| SHALL BE SECURELY FASTENED TO TRANSFER |
| LOAD TO THE MASONRY, CONCRETE OR OTHER |
| STRUCTURAL SUBTRATE AND THE BUCK SHALL |
| EXTEND BEYOND THE INTERIOR FACE OF THE |
| WINDOW OR DOOR FRAME. WINDOW AND DOOR |
| ASSEMBLIES SHALL BE ANCHORED THROUGH THE |
| MAIN FRAME OR BY JAMB CLIP OR SUBFRAME |
| SYSTEM OR THROUGH THE FLANGE TO THE |
| SECURED WOOD BUCK IN ACCORDANCE WITH THE |
| MANUFACTURER?S PUBLISHED INSTALLATION |
| INSTRUCTIONS. UNLESS OTHERWISE TESTED, |
| BUCKS SHALL EXTEND BEYOND THE INTERIOR |
| FACE OF THE WINDOW OR DOOR FRAME SUCH |
| THAT FULL SUPPORT OF THE FRAME IS |
| PROVIDED. SHIMS SHALL BE MADE FROM |
| MATERIALS CAPABLE OF SUSTAINING |
| APPLICABLE LOADS, LOCATED AND APPLIED IN |
| A THICKNESS CAPABLE OF SUSTAINING |
| APPLICABLE LOADS. ANCHORS SHALL BE |
| PROVIDED TO TRANSFER LOAD FROM THE |
| WINDOW OR DOOR FRAME ASSEMBLY TO THE |
| SECURED WOOD BUCK. |
| |
| 13)BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |