Plan Review Details - Permit 05120236
Plan Review Stops For Permit 05120236
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-12-21 Cont ID  
Sent By jwitmer Date 2005-12-21 Time 13:00 Rev Time 0.77
Received By jwitmer Date 2005-12-21 Time 13:00 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-16 Cont ID  
Sent By jleahy Date 2005-12-16 Time 10:52 Rev Time 0.00
Received By jleahy Date 2005-12-16 Time 10:52 Sent To  
Notes
2005-12-18 00:00:00IF THERE ARE EXAM ROOMS IN SPACE THEY
 SHALL COMPLT WITH 517 OF THE NECJL

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-12-20 Cont ID  
Sent By mwennerg Date 2005-12-20 Time 13:22 Rev Time 0.00
Received By mwennerg Date 2005-12-20 Time 13:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-28 Cont ID  
Sent By adarroug Date 2005-12-28 Time 11:12 Rev Time 0.00
Received By adarroug Date 2005-12-28 Time 11:12 Sent To  
Notes
2005-12-28 00:00:00TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-21 Cont ID  
Sent By jwitmer Date 2005-12-21 Time 14:21 Rev Time 0.00
Received By jwitmer Date 2005-12-10 Time 14:38 Sent To  
Notes
2005-12-10 00:00:00TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-01-03 Cont ID  
Sent By tgordon Date 2006-01-03 Time 12:01 Rev Time 0.25
Received By tgordon Date 2006-01-03 Time 12:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-16 Cont ID  
Sent By jleech Date 2005-12-16 Time 11:23 Rev Time 0.30
Received By tgordon Date 2005-12-16 Time 11:23 Sent To E
Notes
2005-12-16 00:00:00*** DENIED ***
 1) NO RETURN AIR GRILLS SHOWING ON
 PLANS, PLEASE COMPLY WITH 2004 FBC/M
 601.4 .
  
 2) PLEASE SHOW DUCT SIZE (FLEX) FOR ALL
 NEW SUPPLY AIR GRILLS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
2005-12-15 00:00:00 
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-01-03 Cont ID  
Sent By jleech Date 2006-01-03 Time 13:19 Rev Time 0.50
Received By jleech Date 2006-01-03 Time 13:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-15 Cont ID  
Sent By jleech Date 2005-12-15 Time 08:13 Rev Time 1.00
Received By jleech Date 2005-12-15 Time 08:13 Sent To  
Notes
2005-12-15 00:00:00DENIED;
 1.PLEASE SHOW A DETAIL OF A SINK IN A
 CABINET. DETAIL SHOWN IS FOR A WALL HUNG
 SINK. SHOW COMPLIANCE TO FBC-2004
 CHAPTER 11 SEC. 11-4.24.1 THRU
 11-4.24.7. SHOW 30" OPENING UNDER SINK
 AND HIGHT OF 34" TO TOP OF SINK.
 2.WATER RISER DIAGRAM, CHANGE AIR
 CHAMBER TO WATER HAMMER ARRESTOR PER.
 SEC. 604.9 AND INSTALLED PER
 MANUFACTURE'S RECOMMENDATIONS, AS CLOSE
 TO SOURCE AS POSIBLE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695