Plan Review Details - Permit 05120236
Plan Review Stops For Permit 05120236 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-12-21 |
Time |
13:00 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2005-12-21 |
Time |
13:00 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2005-12-16 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2005-12-16 |
Time |
10:52 |
Sent To |
|
|
Notes |
2005-12-18 00:00:00 | IF THERE ARE EXAM ROOMS IN SPACE THEY | | SHALL COMPLT WITH 517 OF THE NECJL |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-12-20 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-12-20 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-12-20 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-12-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-28 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-28 |
Time |
11:12 |
Sent To |
|
|
Notes |
2005-12-28 00:00:00 | TO "BOB"#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2005-12-21 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2005-12-10 |
Time |
14:38 |
Sent To |
|
|
Notes |
2005-12-10 00:00:00 | TO "BOB"#4 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-01-03 |
Time |
12:01 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2006-01-03 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-12-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-16 |
Time |
11:23 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-12-16 |
Time |
11:23 |
Sent To |
E |
|
Notes |
2005-12-16 00:00:00 | *** DENIED *** | | 1) NO RETURN AIR GRILLS SHOWING ON | | PLANS, PLEASE COMPLY WITH 2004 FBC/M | | 601.4 . | | | | 2) PLEASE SHOW DUCT SIZE (FLEX) FOR ALL | | NEW SUPPLY AIR GRILLS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | 2005-12-15 00:00:00 | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-01-03 |
Time |
13:19 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2006-01-03 |
Time |
13:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-15 |
Time |
08:13 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2005-12-15 |
Time |
08:13 |
Sent To |
|
|
Notes |
2005-12-15 00:00:00 | DENIED; | | 1.PLEASE SHOW A DETAIL OF A SINK IN A | | CABINET. DETAIL SHOWN IS FOR A WALL HUNG | | SINK. SHOW COMPLIANCE TO FBC-2004 | | CHAPTER 11 SEC. 11-4.24.1 THRU | | 11-4.24.7. SHOW 30" OPENING UNDER SINK | | AND HIGHT OF 34" TO TOP OF SINK. | | 2.WATER RISER DIAGRAM, CHANGE AIR | | CHAMBER TO WATER HAMMER ARRESTOR PER. | | SEC. 604.9 AND INSTALLED PER | | MANUFACTURE'S RECOMMENDATIONS, AS CLOSE | | TO SOURCE AS POSIBLE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
|