Plan Review Stops For Permit 05120232 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-07-11 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-07-11 |
Time |
10:01 |
Sent To |
PC |
|
Notes |
2008-07-11 10:01:42 | REVISION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-02-04 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-02-04 |
Time |
12:55 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-11-30 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-11-30 |
Time |
06:02 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-07-25 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-25 |
Time |
08:40 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2006-07-25 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-06-06 |
Time |
08:16 |
Rev Time |
1.33 |
Received By |
alange |
Date |
2006-06-06 |
Time |
08:06 |
Sent To |
|
|
Notes |
2006-06-06 00:00:00 | DENIED | | | | | | 5.BASED ON ICC BUILDING VALUATION DATA | | THE PERMIT VALUATION IS TOO LOW. | | THE ROOM ADDITION ALONE IS $143,481.00 | | PLUS THE ENCLOSED CARPORT AND ANY OTHER | | ADDIONAL ITEMS. | | REVISE THE PERMIT VALUE AND PAY THE | | ADDITIONAL PERMIT FEES. | | | | 6."R" VALUES ON ENERGY CALCS DO NOT | | MATCH THOSE ON PLANS. | | | | A.SUBMIT TWO SETS OF TRUSS DRAWINGS | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | B. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | | | | | | | NOTE:SINCE MUCH OF THIS WORK HAS BEEN | | COMPLETED WITH OUT INSPECTIONS | | ADDITIONAL ENGINNERING REPORTS MAY BE | | NEEDED AFTER THE PERMIT HAS BEEN ISSUED | | AND YOU ARE READY TO START INSPECTIONS. | | CONTACT KEN CONRAD CHIEF BUILDING | | INSPECTOR ONCE A PERMIT HAS BEEN ISSUED | | TO ARRANGE AN INSPECTION OF THE SITE TO | | DETERMINE WHAT ADDITIONAL ENGINEERING | | REPORTS THAT MAY BE NEEDED. | | | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-14 |
Time |
15:56 |
Rev Time |
2.25 |
Received By |
alange |
Date |
2006-02-14 |
Time |
15:08 |
Sent To |
|
|
Notes |
2006-02-14 00:00:00 | DENIED | | | | 1.ALL PLANS SUBMITTED AFTER OCTOBER, | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | FLORIDA BUILDING CODE. | | | | 2.A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304, AND 305 OF THIS CODE. | | 2004 EXISTING BUILDING CODE 301.5. | | | | 3.PICTURES SHOW A LARGE SLIDING GLASS | | DOOR, YET PLANS SPEC OUT A SMALLER | | FRENCH DOOR.PLEASE CLARIFY. | | | | 4.SHOW SQUARE FOOTAGE ON PLANS OF | | EXISTING AREAS AND NEW ROOM ADDITION AND | | GARAGE AREAS. | | | | 5.BASED ON ICC BUILDING VALUATION DATA | | THE PERMIT VALUATION IS TOO LOW. | | THE ROOM ADDITION ALONE IS $143,481.00 | | PLUS THE ENCLOSED CARPORT AND ANY OTHER | | ADDIONAL ITEMS. | | REVISE THE PERMIT VALUE AND PAY THE | | ADDITIONAL PERMIT FEES. | | | | 6.SUBMIT TWO COPIES OF ENERGY CALCS. | | TO THE 2004 FBC. | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMMENDMENT TO FBC 106.3.3 | | | | NOTE:SINCE MUCH OF THIS WORK HAS BEEN | | COMPLETED WITH OUT INSPECTIONS | | ADDITIONAL ENGINNERING REPORTS MAY BE | | NEEDED AFTER THE PERMIT HAS BEEN ISSUED | | AND YOU ARE READY TO START INSPECTIONS. | | CONTACT KEN CONRAD CHIEF BUILDING | | INSPECTOR ONCE A PERMIT HAS BEEN ISSUE | | TO ARRANGE AN INSPECTION OF THE SITE TO | | DETERMINE WHAT ADDITIONAL ENGINEERING | | REPORTS THAT MAY BE NEEDED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-02-04 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-02-04 |
Time |
10:54 |
Sent To |
M |
|
Notes |
2008-02-04 10:54:54 | ELEC ON ARCH SHEETS NOW UPDATED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2007-11-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-11-30 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-11-01 |
Time |
08:30 |
Sent To |
M |
|
Notes |
2007-11-01 08:52:17 | | | ** DENIED REVISION** | | | | | | 1) NOTE: PLEASE CLARIFY WHERE REVISION #8 IS LOCATED AS | | LISTED ON REVISION TITLE BLOCK. | | FBC 106.1.2 FOR COORDINATION AND ADDITIONAL | | INFORMATION. | | | | 2) NOTE: PLEASE SEE RECEPTACLE ALONG KITCHEN WALL | | WITHIN 6FT OF DOOR IS STILL MISSING PER 210.52. | | REDLINED ON PREVIOUS PLANS. | | | | 3) NOTE: PLEASE SEE KITCHEN WALL RECEPTACLES STILL | | SHOWN ON LIVING ROOM CIRCUIT WHICH IS NOT PERMITTED PER | | 210.52B1. | | | | 4) NOTE: PLEASE SEE BATHS 1 AND 2 ARE BOTH SHOWN | | CIRCUITED TOGETHER WHICH IS NOT PERMITTED PER 210.11C3. | | MAY ONLY CIRCUIT THE RECEPTACLES TOGETHER OR IF | | LIGHTING ETC IS ON WITH THE RECEPTACLE THEN NO OTHER | | AREAS OR ELECTRICAL IS PERMITTED TO BE FED. MAY NOT | | CIRCUIT AS SHOWN. | | | | 5) NOTE: PLEASE SEE SHEET A-2 AS THIS SHOWS PANEL AS | | 150AMPS. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-05-02 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-05-02 |
Time |
12:18 |
Sent To |
PC |
|
Notes |
2007-05-02 15:40:58 | REDLINED MISSING RECEPT PER 210.52, REDLINED KITCHEN | | RECEPT SHOWN ON LIV RM CIRCUIT WHICH IS NOT PERMITTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-04-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-05 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-05 |
Time |
11:22 |
Sent To |
PC |
|
Notes |
2007-04-05 13:26:59 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE RISER DIAGRAM AND PLANS DO NOT | | MATCH. PLEASE SEE THAT THE PANEL *B* STILL DOES NOT | | INCLUDE ANY BREAKER OR OCP FEEDING PANEL *A*.. | | 215.5, 240.4, 310.16 | | | | 2) NOTE: PLEASE SEE THAT NEW SMOKE ALARM CIRCUIT | | REQUIRES ARC FAULT PROTECTION PER 210.12. | | PLEASE SEE THAT ALL CIRCUITS IN SLEEPING ROOMS FOR LTS, | | SA?S , RECEPTS AND FANS ARE AFCI. | | | | 3) NOTE: PLEASE SEE MISSING DISCONNECTS FOR AHU?S #1 | | AND #2. | | 440.11 | | | | 3) NOTE: PLEASE SEE DISHWASHER AND DISPOSAL BOTH SEEM | | TO SHOWN TO THE SAME DEVICE/YOKE. PLEASE SEE 210.4 AS | | IF THIS IS INDEED AS SHOWN THEN THIS WOULD REQUIRE THE | | BOTH OF THESE ON A 2-POLE BREAKER. | | | | 4) NOTE: PLEASE SEE JACUZZI TUB, PLEASE VERIFY THE | | BREAKER AND CONDUCTOR SIZE. THE SIZE OF THE CONDUCTORS | | WAS CHANGED TO #12 AWG, YET THE BREAKER WAS LEFT AT | | 15AMPS? | | PLEASE VERIFY THIS AS IT IS NOT A CODE VIOLATION ONLY A | | COMMENT. | | | | 5) NOTE: PLEASE SEE THAT NO HAND-DRAWN CHANGES ARE TO | | BE MADE TO PLANS. PLEASE SEE SEVERAL AREAS WHICH | | HAND-WRITTEN ITEMS WERE CHANGED. | | PLEASE REVISE THESE WHEN MAKING CORRECTIONS TO OTHER | | COMMENTS. | | FBC 106.1.2 | | | | 6) NOTE: PLEASE SEE THE PLANS ARE NOW CALLING FOR THE | | CODES TO BE LISTED UNDER THE 2005 NEC WHEN IN FACT THIS | | PROJECT WAS PERMITTED UNDER THE 2002 NEC. | | PLEASE LIST THE FOLLOWING CODES. | | 2002 NFPA-70 | | 2002 NFPA-72 | | | | 7) NOTE: PLEASE SEE RECEPTACLES IN KITCHEN, DINING, | | BREAKFAST AREAS ARE TO BE ON ONE OR MORE OF THE SMALL | | APPLIANCE CIRCUITS. PLEASE SEE 210.52B1, 210.11C1, | | 220.16. | | PLEASE SEE SOME SHOWN ON THE LIGHTING CIRCUITS, THIS IS | | NOT PERMITTED. | | | | 8) NOTE: PLEASE SEE THE PANEL SCHEDULE SHALL BE | | COMPLETE WITH ALL CIRCUITS TO ROOMS AND AREAS IN WHICH | | THEY FEED. THE USE OF *GENERAL LIGHTING * OR GEN | | RECEPTS* IS NOT PERMITTED. | | PLEASE SEE THE FOLLOWING TEXT WHICH IS TAKEN DIRECTLY | | FROM THE CODE IN 408.4 | | * | | CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* | | 408.4, 310.16, 240.4 ETC | | FBC 106.3.5.4 | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-09 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-09 |
Time |
12:33 |
Sent To |
PC |
|
Notes |
2007-02-09 12:48:39 | ***** UNSAT ***** | | | | | | 1) NOTE: PLEASE CORRELATE THE RISER DIAGRAM WITH ALL | | ELECTRICAL SERVICE EQUIPMENT AND PANEL SCHEDULES. | | PLEASE SEE THERE ARE SEVERAL ITEMS WHICH DO NOT MATCH. | | PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS FROM METER | | TO PANEL *B* ARE NOT LARGE ENOUGH. | | PLEASE REMOVE ANY EQUIPMENT GROUNDING CONDUCTORS BEFORE | | THE FIRST MEANS OF DISCONNECT. (CONFUSING AS THE RISER | | AND PLANS DO NOT MATCH). | | PLEASE SEE MISSING EQUIPMENT GROUNDING AFTER THE FIRST | | MEANS OF DISCONNECT. | | PLEASE SEE 250A MAIN ON 125A PANEL. | | PLEASE SEE LOAD ON PANEL EXCEEDS RATING. | | PLEASE SEE PLANS WHICH DO NOT MATCH WITH RISER. | | PLEASE SUBMIT THE PANEL SCHEDULE FOR THE METER/MAIN | | COMBO WHICH IS MENTIONED, IF THERE IS ONE. | | PLEASE COMPLETE AND CORRELATE LOADS ON EACH PANEL AND | | SERVICE. | | ETC. | | PLEASE SEE 310.16, 310.15B6, 240.4, 240.24, 408, | | 230.70, 230.79, 230.76 ETC. | | | | *THERE ARE SEVERAL ITEMS WHICH NEED TO BE CORRECTED. | | | | 2) NOTE: PLEASE SUBMIT A PANEL SCHEDULE WHICH REFLECTS | | ROOM AND AREAS IN WHICH THEY FEED. | | PLEASE SEE THE FOLLOWING TEXT WHICH WILL HELP EXPLAIN. | | THIS REQUIRES THAT THE IDENTIFICATION FOR EVERY | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION. | | | | 3) NOTE: PLEASE KNOW THAT A MEETING WAS HELD AT THE | | SOUTHERN SECTION MEETING IN OCT 06 WHERE WE WERE | | DIRECTLY INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE | | DETECTORS ON PLANS FOR RESIDENTIAL HOMES IS NOT | | ACCEPTABLE WHEN THESE DEVICES ANY ACTUALLY FALL UNDER | | THE DEFINITIONS OF SMOKE ALARMS WHICH WOULD BE SHOWN AS | | SA/SMOKE ALARMS. | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | FOR OTHER NEW HOMES. | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | 4) NOTE: PLEASE SEE THAT THERE ARE ELECTRICAL | | APPLIANCES AND EQUIPMENT ON PLANS WHICH ARE NOT ON | | PANEL SCHEDULES OR IN LOAD CALCULATIONS. | | 240.4,310.16,220,408.4 ETC. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-24 |
Time |
13:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-05-24 |
Time |
12:06 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-29 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-27 |
Time |
06:20 |
Sent To |
|
|
Notes |
2005-12-29 00:00:00 | ************ UNSAT ************ | | | | *** PLEASE SEE SOME OF THE SAME NOTES | | ARE FOR THE REVIEWS DONE UNDER OLD | | "REMODEL" PERMIT OF 04120970. | | | | ** PLEASE SEE A 4X FEE WAS ADDED AS PER | | "HOLD" WHICH WAS IN COMPUTER AT TIME OF | | APPLICATION, HOWEVER WAS NOT ASSESSED. | | PLEASE KNOW THIS PROPERTY HAD A | | "STOPWORK" ORDER GIVEN IN 2003 FOR THE | | REAR ADDITION WHICH IS IN FULL EFFECT. | | FEES OWED. | | | | *************************************** | | PLEASE SEE NUMEROUS LOCATIONS ON PLANS | | IN WHICH PLANS ARE REFERENCING THE 2001 | | FBC, PLEASE KNOW THE FBC IS NOW THE 2004 | | EDITION WHICH WENT INTO EFFECT ON OCT. | | 1ST, 2005 | | | | 1)NOTE: PLEASE SEE PLANS STILL DO NOT | | CONTAIN THE PRINTED NAME AND SIGNATURE | | OF THE PERSON TAKING RESPONSIBILITY OF | | SAID PLANS /DESIGN. | | PLEASE SEE FBC ADMINISTRATIVE SECTION, | | 106.3.4.3 | | | | 2)NOTE: PLEASE CLARIFY SERVICE ONCE | | AGAIN, PLEASE SEE SERVICE EQUIPMENT OF | | SOME SORT IS BEING SHOWN AS 250A'S? BUT | | IS UNCLEAR IF THIS IS METER/MAIN OR A | | 250A MB PANEL WITH SUB BRANCH BRKRS? NO | | SCHEDULE SUBMITTED? | | PLEASE INDICATE THE SIZE OF THE NEW | | METERCAN(ASBUILT). | | 215.5 | | | | 3)NOTE: PLEASE SEE #14 AWG STILL BEING | | SHOWN WITH 20A OCP. | | 240.4, 310.16 | | | | 4)NOTE: PLEASE SEE MISSING SD'S AS | | REQUIRED UNDER 2002 NFPA-72 11.5.1.1 | | SD'S INSIDE AND OUTSIDEALL SLEEPING | | RMS. SEE 2ND FLR. | | | | 5)NOTE: PLEASE SEE MISSING RECEPT W/IN | | 6' OF DOOR WAY. 210.52 | | | | 6)NOTE: PLEASE SEE PLANS ARE STILL | | SHOWING THE AHU OUTSIDE??? | | PLEASE SHOW ALL A/C EQUIPMENT ON PLANS | | ALONG WITH THE REQUIRED DISCONNECTS PER | | 440.11 | | | | 7)NOTE: PLEASE SEE COPY OF FS | | 553.80(2)(B)ATTACHED. PLEASE SEE IS | | PLANS COME BACK IN WITHOUT COMMENTS | | BEING FULLY ADDRESSED, PLANS SHALL BE | | TURNED INTO THE STATE FOR PEIR REVIEW BY | | THE FLORIDA BOARD OF ENGINEER'S. | | | | | | | | ** PLEASE SEE BLDG NOTES, AS PLANS SHOW | | DOORS AS BEING "FRENCH DOORS", HOWEVER | | SLIDING DOORS ARE INSTALLED. | | | | ** PLEASE SEE ANY OTHER COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | 2005-12-27 00:00:00 | IN ELEC FOR REVIEW, ON HOLD UNTIL4X | | FEE AS SHOWN IN COMPUTER IS CLEARED OR | | FEES ACCESSED. | | SHOULD HAVE BEEN ASSESSED WHEN SUBMITTED | | OR SIGNED OFF BY A BLDG DEPT MANG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2008-07-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-01 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-01 |
Time |
15:41 |
Sent To |
B |
|
Notes |
2008-07-01 15:42:34 | TO "MJACOBS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2008-02-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-01 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-01 |
Time |
11:29 |
Sent To |
|
|
Notes |
2008-02-01 11:37:24 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-30 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-30 |
Time |
10:18 |
Sent To |
Z |
|
Notes |
2007-10-30 10:18:58 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-01 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-01 |
Time |
16:43 |
Sent To |
E |
|
Notes |
2007-05-01 16:44:09 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-02 |
Time |
18:14 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-02 |
Time |
18:14 |
Sent To |
M |
|
Notes |
2007-04-02 18:15:18 | MECH REV TO TOM GORDON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-02 |
Time |
18:14 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-02 |
Time |
18:14 |
Sent To |
E |
|
Notes |
2007-04-02 18:14:44 | ELEC REV TO DEWEY PALMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-12 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-12 |
Time |
16:50 |
Sent To |
M |
|
Notes |
2007-02-12 16:50:46 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-08 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-08 |
Time |
08:55 |
Sent To |
E |
|
Notes |
2007-02-08 09:00:48 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-07-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-22 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-22 |
Time |
15:37 |
Sent To |
B |
|
Notes |
2006-07-22 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-22 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-22 |
Time |
11:36 |
Sent To |
E |
|
Notes |
2006-05-22 00:00:00 | TO "E" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-02 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-02 |
Time |
11:53 |
Sent To |
Z |
|
Notes |
2006-05-02 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-22 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-22 |
Time |
08:56 |
Sent To |
E |
|
Notes |
2005-12-22 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-14 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-12-06 |
Time |
13:59 |
Sent To |
|
|
Notes |
2005-12-06 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-02-04 |
Time |
11:43 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-02-04 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2008-02-04 11:48:37 | *** PROVISO *** | | 1) BATHROOM EXHAUST FANS SHALL BE INSTALLED WHERE | | REQUIRED BY 2004 FBC/R R303.3 EXCEPTION. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2007-11-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-11-01 |
Time |
16:44 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-11-01 |
Time |
16:44 |
Sent To |
P |
|
Notes |
2007-11-01 16:45:30 | REVISION TO MECH. PLAN PAGE M-1. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-07-26 |
Time |
13:43 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-07-26 |
Time |
13:43 |
Sent To |
|
|
Notes |
2007-07-26 13:43:56 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-03 |
Time |
09:11 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-04-03 |
Time |
09:11 |
Sent To |
|
|
Notes |
2007-04-03 09:12:26 | REVISION TO MECH. PLANS PAGE M-1 AND E-CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-15 |
Time |
08:52 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-02-15 |
Time |
08:52 |
Sent To |
|
|
Notes |
2007-02-15 09:07:09 | MECHANICAL REVISION | | *** DENIED *** | | 1) SEE NOTES: ON PLANS A/C WILL BE ACCORDING TO S.B.C. | | 2001, THE BUILDING CODES BEING USED BY THE CITY OF WEST | | PALM BEACH IS THE 2004 F.B.C., PLEASE CORRECT. | | | | 2) 12'X13" RETURN AIR DUCT FROM THE 2ND. FLOOR TO THE | | 1ST. FLOOR IS TO SMALL FOR 1535 CFM'S., PLEASE CORRECT, | | PER 2004 FBC/R M1602.4. | | | | 3) 10" RETURN AIR DUCT (FLEX) IN EXISTING FAMILY ROOM | | IS TO SMALL FOR 1125 CFM'S. AND 12'X12' GRILL, PLEASE | | CORRECT, PER 2004 FBC/R M1602.4. | | | | 4) YELLOW HIGH LIGHTED RETURN AIR TRANSFER DUCT TO | | EXISTING BEDROOM NEEDS TO BE SIZED. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-24 |
Time |
16:37 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-05-24 |
Time |
16:37 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-12-29 |
Time |
10:14 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2005-12-29 |
Time |
10:14 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | *** DENIED *** | | 1) NEED TO SUBMIT ENERGY CALCULATIONS. | | ENERGY CALCULATIONS NEED TO BE ON FORM | | 600A-04 (2004) PER FBC 13-600.3.A . | | | | 2) ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | FBC 104.2.1 . | | | | 3) NEED TO SHOW THE SIZE OF THE SUPPLY | | AND RETURN AIR DUCTS GOING DOWN TO THE | | FIRST FLOOR. | | | | 4) SUPPLY AIR DUCT IN MASTER SUITE WIC | | IS NOT SIZED. | | | | 5) ALL RETURN AIR DUCTS ARE TO SMALL SEE | | NOTE #6. | | | | 6) BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-11-07 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-11-07 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-07 |
Time |
08:56 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-06-06 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-06-06 |
Time |
07:53 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-29 |
Time |
08:45 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-12-29 |
Time |
08:45 |
Sent To |
M |
|
Notes |
2005-12-29 00:00:00 | DENIED; | | 1.RISER DIAGRAM NOT SHOWN FOR MASTER | | BATHROOM ON 2ND FLOOR. PLEASE SUBMIT SO | | A PLUMBING PLAN REVIEW CAN BE DONE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-10-31 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-31 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-31 |
Time |
09:50 |
Sent To |
E |
|
Notes |
2007-10-31 10:02:42 | ***APPROVED - REVISION - CHANGE WOOD FRAME WALLS TO | | CONCRETE BLOCK.*** | | | | SENT TO "E" - DP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-05-18 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-05-18 |
Time |
15:50 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-12-20 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-12-20 |
Time |
16:54 |
Sent To |
I |
|
Notes |
2005-12-20 00:00:00 | DENIED, | | 1. MUST SHOW THE WORK (ADDITION) ON THE | | TWO COPY OF SURVEY WITH SETBACKS. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|