Plan Review Details - Permit 05120189
Plan Review Stops For Permit 05120189
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-06 Cont ID  
Sent By alange Date 2006-03-06 Time 09:30 Rev Time 0.75
Received By alange Date 2006-03-06 Time 09:30 Sent To  
Notes
2006-03-06 00:00:00DENIED
  
 1.CLEARLY EXPLAIN SCOPE OF WORK ON
 APPLICATION.
  
 2.SHOW EXISTING AREAS AND NEW WORK TO
 BE DONE ON PLANS.
  
 3.THREE DIFFERENT SHEETS OF A-1 PAGES
 SUBMITTED.
  
 4.INSUFFICIENT INFORMATION SUBMITTED
 FOR A COMPLETE PLAN REVIEW.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-04 Cont ID  
Sent By dpalmer Date 2006-01-04 Time 16:16 Rev Time 0.00
Received By dpalmer Date 2006-01-04 Time 16:16 Sent To I
Notes
2006-01-04 00:00:00*** UNSAT ***
  
 1)NOTE: PLEASE SEE NO ELECTRICAL PLANS
 WERE SUBMITTED FOR REVIEW OF NEW
 /REMODELED LAUNDRY ROOM.
  
 PLEASE SUBMIT PLANS FOR SCOPE OF
 PROPOSED WORK.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-01-10 Cont ID  
Sent By mwennerg Date 2006-01-10 Time 15:27 Rev Time 0.00
Received By mwennerg Date 2006-01-10 Time 15:27 Sent To  
Notes
2006-01-10 00:00:00******DENIED******
  
 1) PLEASE NOTE THAT DUE TO LACK OF
 INFORMATION ON PLANS, A COMPLETE FIRE
 PLAN REVIEW CAN'T BE DONE AT THIS TIME.
  
 2) PLANS DON'T SHOW ANY EXISTING OR NEW
 EXIT LIGHTS AND EMERGENCY LIGHTING
 FACILITIES.
  
 3) SEPARATE SHOP DRAWINGS AND PERMITS
 REQUIRED FOR FIRE SPRINKLER AND FIRE
 ALARM REMODEL.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLANS REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-06 Cont ID  
Sent By alange Date 2006-03-06 Time 09:34 Rev Time 0.00
Received By alange Date 2005-12-10 Time 13:20 Sent To  
Notes
2005-12-13 00:00:00TO "COMM" BD#8
2005-12-10 00:00:00WAITING FOR "COMM" BD/ COPY OF CLUBHOUSE
 APPL. SENT TO ADDRESSING.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-10 Cont ID  
Sent By hmoser Date 2006-02-10 Time 14:44 Rev Time 0.00
Received By hmoser Date 2006-02-10 Time 14:44 Sent To  
Notes
2006-02-10 00:00:00NO MECHANICAL PLANS HM.

Review Stop P PLUMBING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pschmitz Date 2006-02-18 Time 10:35 Sent To  
Notes
2006-02-18 00:00:00PLUMBING PLAN REVIEW EXAMINER
 PAUL SCHMITZ 561-805-6692
 [email protected]
 FBC PLUMBING 2004
 FBC FUEL GAS 2004
 FBC BUILDING 2004, CH 11
 DENIED
  
 1) PLEASE NOTE THAT DUE TO LACK OF
 INFORMATION ON PLANS, A PLUMBING
 PLAN REVIEW CAN'T BE DONE AT THIS TIME.
  
 2)SEC 106.3.5.1.3 (4.)
 COMMERICAL BUILDINGS,
 PLUMBING SANITARY DRAINAGE.
 ( DWV ISOMETRIC ) REQUIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692