Plan Review Stops For Permit 05120152 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-02-06 |
Time |
17:13 |
Rev Time |
1.00 |
Received By |
mjacobs |
Date |
2006-02-06 |
Time |
16:18 |
Sent To |
PC |
|
Notes |
2006-02-06 00:00:00 | BUILDING PROVISO: | | TO BE IN PLACE AT C.O.: | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | ASTM D5034 100 LB TENSILE STRNGTH | | ASTM D3787 150 LB BALL BURST | | STRENGTH | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-01-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-01-06 |
Time |
08:23 |
Rev Time |
1.15 |
Received By |
mjacobs |
Date |
2006-01-06 |
Time |
07:09 |
Sent To |
PC |
|
Notes |
2006-01-06 00:00:00 | 1) PLEASE SEE COMMENTS FROM | | ZONING/PLUMBING AND ELCETRICAL. THESE | | COMMENTS SHOULD BE ADDRESSED BEFORE I | | CAN FINISH MY REVIEW. | | | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-22 |
Time |
15:19 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-02-22 |
Time |
15:15 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-03 |
Time |
17:27 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-02-03 |
Time |
17:18 |
Sent To |
P |
|
Notes |
2006-02-03 00:00:00 | | | SUBMIT A LOAD CALCULATION FOR THE | | SERVICE INCLUDING THE NEW EQUIPMENT. | | INDICATE THE SIZE OF THE EXISTING | | SERVICE. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-23 |
Time |
15:53 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-12-23 |
Time |
15:48 |
Sent To |
P |
|
Notes |
2005-12-23 00:00:00 | | | PLEASE SUBMIT DETAILS FOR THE PANEL | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | SERVICE. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2005-12-29 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2005-12-29 |
Time |
11:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-02-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-19 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-19 |
Time |
12:23 |
Sent To |
E |
|
Notes |
2006-02-19 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-02 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-02 |
Time |
16:41 |
Sent To |
E |
|
Notes |
2006-02-02 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-26 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-26 |
Time |
09:38 |
Sent To |
Z |
|
Notes |
2006-01-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-22 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-22 |
Time |
08:59 |
Sent To |
E |
|
Notes |
2005-12-22 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-01-06 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-07 |
Time |
11:05 |
Sent To |
|
|
Notes |
2005-12-07 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-22 |
Time |
15:59 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-02-22 |
Time |
15:58 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-06 |
Time |
10:33 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-02-06 |
Time |
10:33 |
Sent To |
B |
|
Notes |
2006-02-06 00:00:00 | DENIED 2ND TIME | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | 1) FBC-2004 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (NOTE:STILL NEED | | MANUFACTURE SHEETS WITH THIRD PARTY | | LISTING THE INFORMATION YOU HAVE | | SUBMITTED ARE SPEC SHEETS) | | 2) FBC-2004 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF.(NOTE: STILL NEED MANUFACTURE CUT | | SHEET SUBMITTAL IF ONE CANNOT BE FOUND | | AN EXTERNAL HARTFORD LOOP SHALL BE | | PROVIDED AND SHOWN ON PIPING SCHEMATIC.) | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561)805-6730 | | FAX (561)805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561)805-6721 | | | | . |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2005-12-29 |
Time |
11:39 |
Rev Time |
1.25 |
Received By |
mperson |
Date |
2005-12-29 |
Time |
11:39 |
Sent To |
B |
|
Notes |
2005-12-29 00:00:00 | DENIED | | | | REFERENCE: FBC-2004424.2 SWIMMING | | POOLS. | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR POOL PLUMBING PERMIT: | | 1) THE PIPING SCHEMATIC SHOWS ONLY ONE | | MAIN DRAIN TO THE POOL WITH A 1" VENT. | | THERE SHOULD ALSO BE A MAIN DRAIN SHOWN | | FOR THE SPA WITH A 1-1/2" VENT.PLEASE | | CORRECT THE PIPING SCHEMATIC DRAWING TO | | SHOW BOTH MAIN DRAINS ON SCHEMATIC. | | 2) COMPLY WITH FBC-2004 SEC 424.2 | | PRIVATE SWIMMING POOLS.(ADD TO NOTES) | | 3) FBC-2004 424.2.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | SHEETS REQUIRED. (SUBMITTAL) | | 4) FBC-2004 424.2.14.2 WATER RETENTION, | | PROVIDE A POSITIVE MEANS OF RETAINING | | WATER IN THE HEATER WHEN PUMP IS SHUT | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-31 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-31 |
Time |
17:46 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-12-20 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-12-20 |
Time |
16:05 |
Sent To |
I |
|
Notes |
2005-12-20 00:00:00 | DENIED, | | 1. SPA MUST BE 5FT ON THE SIDE (FROM | | WATER'S EDGE TO PROPERTY LINE). | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|