Plan Review Details - Permit 05120146
Plan Review Stops For Permit 05120146 |
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-01-17 |
Time |
10:58 |
Rev Time |
1.00 |
Received By |
mperson |
Date |
2006-01-17 |
Time |
10:58 |
Sent To |
PC |
|
Notes |
2006-01-17 00:00:00 | DENIED 2ND TIME | | | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS STILL | | REQUIRED FOR GAS PERMIT: | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE.I HAVE INCLOSED AN EXAMPLE | | OF AN ISOMETRIC DRAWING OF WHICH I THINK | | YOU ARE TRYING TO CONVEY WITH OUT THE | | MEASUREMENTS.IF THIS IS WHAT YOU ARE | | TRYING TO CONVEY FILL IN THE | | MEASUREMENTS ,SIGN, AND PRINT NAME OF | | PERSON WHO DID DRAWING AND RESUBMIT. | | NOTE, 2 COPIES REQUIRED | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | 3. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561)805-6730 | | FAX (561)805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561)805-6721 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2005-12-29 |
Time |
08:09 |
Rev Time |
1.25 |
Received By |
mperson |
Date |
2005-12-29 |
Time |
08:09 |
Sent To |
|
|
Notes |
2005-12-29 00:00:00 | DENIED | | | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR A GAS PERMIT: | | 1.SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS. | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | 3. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | 4.PLEASE NOTE ON YOUR SUBMITTED DRAWING | | THAT WITH THE TOTAL AMOUNT OF BTU LOAD | | ON SYSTEM WITH THE LONGEST LENGTH METHOD | | THAT THE PIPE TO THE GENERATOR NEEDS TO | | BE 1-1/4" AND THE PIPE FROM THE METER TO | | THE GENERATOR BRANCH TEE NEEDS TO BE | | 1-1/2". REFERENCE: FBC-2004 FUEL GAS | | TABLE 402.4(2) AND TABLE 402.4(20) | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-30 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-30 |
Time |
16:06 |
Sent To |
G |
|
Notes |
2005-12-30 00:00:00 | TO "G" BOX/RESUB |
|
|
|