Plan Review Stops For Permit 05111146 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-09-01 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-09-01 |
Time |
16:29 |
Sent To |
|
|
Notes |
2006-09-01 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | 1.)THE NEW ANCHOR SCHEDULE SPECIFIES | | TAPCONS, BUT YOU HAVE SPECIFIED AND | | HIGHLIGHTED ANCHORING FOR WEDGE-BOLTS. | | | | 2.)YOU HAVE INDICATED THAT THE | | SHUTTERS WILL BE INSTALLED HORIZONTALLY; | | ACCORDION SHUTTERS ARE INSTALLED | | VERTICALLY. | | | | 3.)THE SPAN ON THE CHART IS CONSISTENT | | WITH THE OPENING WIDTH, INDICATING THAT | | THE SPAN IS HORIZONTAL.PLEASE ALSO | | REVISE OPENING SIZES IF NECESSARY. | | | | 4.)PLEASE CONTACT ME AND ARRANGE A | | MEETING IF YOU NEED ASSISTANCE IN | | UNDERSTANDING WHAT IS REQUIRED TO SHOW | | CODE COMPLIANCE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-08-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-08-05 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-08-05 |
Time |
14:43 |
Sent To |
|
|
Notes |
2006-08-05 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | 1.)THE NEW ANCHOR SCHEDULE SPECIFIES | | PRESSURES OF -57, 12" ANCHOR SPACING. | | YOU HAVE HIGHLIGHTED -60 ON PAGE 10 FOR | | DESIGN PRESSURE BUT ALSO HIGHLIGHTED 12" | | WHICH IS IN THE -40 COLUMN.-60 | | REQUIRES 10" OR CLOSER ANCHOR SPACING, | | DEPENDING ON SHUTTER SPAN, NOT 12". |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-01-20 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-01-20 |
Time |
16:06 |
Sent To |
|
|
Notes |
2006-01-20 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | 1.)HOW HAVE YOU DETERMINED THAT ALL | | OPENINGS ARE IN ZONE 4?THE ANCHOR | | SPACING IS NONCOMPLIANT FOR ZONE 5. | | ADDRESS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-12-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-10 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-10 |
Time |
14:11 |
Sent To |
|
|
Notes |
2005-12-10 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | 1.) OPENING 10 IS A LEXAN PANEL.IMPACT | | PROTECTION IS TO COMPLY WITH | | FBC1609.1.4.EITHER SHOW COMPLIANCE FOR | | THE LEXAN OR REMOVE FROM SCOPE OF WORK | | ON THE PERMIT. | | | | 2.)AN ENGINEERING SHEET WAS ATTACHED | | TO THE BACK OF THE PRODUCT APPROVAL. | | ALL ENGINEERING WHICH IS NOT A PART OF | | THE PRODUCT APPROVAL ON FILE WITH THE | | STATE IS TO BE SIGNED, SEALED ORIGINAL | | IF YOU WANT FOR IT TO BE A PART OF THE | | PERMIT PACKAGE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-14 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-14 |
Time |
11:48 |
Sent To |
B |
|
Notes |
2006-08-14 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-02 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-02 |
Time |
10:42 |
Sent To |
B |
|
Notes |
2006-08-02 00:00:00 | TO 'SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-29 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-29 |
Time |
14:07 |
Sent To |
B |
|
Notes |
2006-06-29 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-17 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-17 |
Time |
15:26 |
Sent To |
B |
|
Notes |
2006-01-17 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-10 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-01 |
Time |
15:40 |
Sent To |
|
|
Notes |
2005-12-01 00:00:00 | TO "MISC" BOX#1 |
|
|