Plan Review Details - Permit 05111131
Plan Review Stops For Permit 05111131
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-02-01 Cont ID  
Sent By amorse Date 2006-02-01 Time 09:13 Rev Time 0.33
Received By amorse Date 2006-02-01 Time 09:13 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-01 Cont ID  
Sent By amorse Date 2005-12-30 Time 09:12 Rev Time 0.00
Received By amorse Date 2005-12-30 Time 15:15 Sent To  
Notes
2005-12-30 00:00:00 
  
 DENIED
  
 1) SWIMMING POOL AND SPAS
 DESIGN,CONSTRUCTION AND WORKMANSHIP
 SHALL CONFORM WITH AT A MINIMUM
 ANSI/NSPI 3 FOR PERMAMENTLY INSTALLED
 SPAS AND ANSI/NSPI 5 FOR INGROUND POOLS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-31 Cont ID  
Sent By btrobaug Date 2006-01-31 Time 10:27 Rev Time 0.33
Received By btrobaug Date 2006-01-31 Time 09:36 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-15 Cont ID  
Sent By btrobaug Date 2005-12-15 Time 08:01 Rev Time 0.33
Received By btrobaug Date 2005-12-15 Time 07:46 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 13:59 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 13:59 Sent To E
Notes
2006-01-30 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-01-09 Cont ID  
Sent By adarroug Date 2006-01-09 Time 15:52 Rev Time 0.00
Received By adarroug Date 2006-01-09 Time 15:52 Sent To Z
Notes
2006-01-09 00:00:00TO "Z" BOX/RESUB-NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-14 Cont ID  
Sent By adarroug Date 2005-12-14 Time 10:43 Rev Time 0.00
Received By adarroug Date 2005-12-14 Time 10:43 Sent To E
Notes
2005-12-14 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date 2006-02-01 Cont ID  
Sent By amorse Date 2005-12-30 Time 09:13 Rev Time 0.00
Received By amorse Date 2005-11-30 Time 18:18 Sent To  
Notes
2005-11-30 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-01-31 Cont ID  
Sent By mperson Date 2006-01-31 Time 15:13 Rev Time 1.25
Received By mperson Date 2006-01-31 Time 15:13 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By mperson Date 2005-12-20 Time 15:53 Rev Time 1.25
Received By mperson Date 2005-12-20 Time 15:48 Sent To B
Notes
2005-12-20 00:00:00DENIED
 REFERENCE: FBC-2004 424.2 SWIMMING POOLS
  
 1) FBC-2004 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2004 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)
 3) FBC-2004 SEC 424.2.9 WATER SUPPLY,
 LOCAL ORD.#2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4) FBC-2004 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2004 SEC 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21 PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 6) FBC-2004 SEC 424.2.14.2 WATER
 RETENTION PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE CUT SHEETS
 SUBMITTAL)
 7) CITY OF WEST PALM BEACH ADD. TO
 FBC-2004 SEC 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE BUILDING OFFICIAL.
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-27 Cont ID  
Sent By mmclean Date 2006-01-27 Time 18:34 Rev Time 0.00
Received By mmclean Date 2006-01-27 Time 18:34 Sent To I
Notes
2006-01-27 00:00:00RESUB - NEW SHEETS

Review Stop Z ZONING
Rev No 1 Status P Date 2005-12-13 Cont ID  
Sent By mmclean Date 2005-12-13 Time 08:24 Rev Time 0.00
Received By mmclean Date 2005-12-13 Time 08:24 Sent To B
Notes
***NONE***