Plan Review Details - Permit 05110873
Plan Review Stops For Permit 05110873
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2007-04-16 Cont ID  
Sent By lursu Date 2007-04-16 Time 15:24 Rev Time 0.00
Received By lursu Date 2007-04-16 Time 15:24 Sent To  
Notes
2007-04-16 15:31:13 
 THE INFORMATION RECEIVED FROM THE PLANING DEPARTMENT
 REGARDING THE PORTION OF THE LAND EAST OF N FLAGLER DR
 VALIDATES THAT BELONGS TO THE ROSARIAN ACADEMY.THE
 PARCEL CONTROL NUMBER = 74 43 43 15 21 004 0010 WITH
 807 N FLAGLER DR WAS CORRECT APPLIED TO THIS PERMIT.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-04-16 Cont ID  
Sent By lursu Date 2007-03-29 Time 15:24 Rev Time 0.00
Received By lursu Date 2007-03-08 Time 11:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-01 Cont ID  
Sent By jwitmer Date 2007-08-01 Time 08:42 Rev Time 1.22
Received By jwitmer Date 2007-08-01 Time 08:14 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-13 Cont ID  
Sent By jwitmer Date 2007-06-13 Time 13:10 Rev Time 2.22
Received By jwitmer Date 2007-06-13 Time 13:09 Sent To PC
Notes
2007-06-13 13:17:29BUILDING PLAN REVIEW
 PERMIT: 05110873
 ADD: 807 N FLAGLER DR
 CONT: ANDERSON MOORE
 TEL: (561)662-1819
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) COMMENT # 3 FROM THE PREVIOUS REVIEW DEALS WITH THE
 WIND LOAD INFORMATION REGARDING THE LIGHT POLES. THE
 RESPONSE INDICATES THEY WERE ORDERED FROM THE
 MANUFACTUERER?
 PLEASE PROVIDE THE WIND LOAD CALCULATIONS THAT ARE
 SIGNED AND SEALED BY A FLORIDA LICENSED ENGINEER. IT
 APPEARS THAT THE MANUFACTURER MAY BE ACTING AS AN
 ENGINEER?
  
 3) SEE ELECTRICAL COMMENTS IN REGARDS TO EITHER
 LICENSINFG REQUIREMENTS FOR ARCHITECTS OR ENGINEERS.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-13 Cont ID  
Sent By jwitmer Date 2007-03-13 Time 08:33 Rev Time 2.22
Received By jwitmer Date 2007-03-13 Time 08:33 Sent To  
Notes
2007-03-13 08:49:05BUILDING PLAN REVIEW
 PERMIT: 05110873
 ADD: 807 N FLAGLER DR
 CONT: ANDERSON-MOORE
 TEL: (561)753-7400
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) PLEASE PROVIDE DOCUMENTATION OF OWNERSHIP TO THE
 LAND EAST OF N. FLAGLER DR.
 SEE ATTACHMENT THIS LAND DOESN,T SHOW AS A LOT.106.1.2*
 ADDITIONAL INFORMATION REQUIRED.
  
 3) PLANS SHOW THE INSTALLATION OF NEW LIGHT POLES ON
 THE EAST SIDE OF FLAGLER DR AGAIN NO INFORMATION WHERE
 THE POLES AND OR FIXTURES MEET WIND LOADS.NOTE THE
 CLOSENESS TO THE INTERCOASTAL, ASCE 7-02. 106.1.2*
 ADDITIONAL INFORMATION REQUIRED.
  
 4)THE ORIGINAL PERMIT THAT WAS PERMITTED WAS FOR THE
 EAST SIDE OF FLAGLER, NO TRADE REVIEW, NOW A REVISION
 INDICATES A REMOVAL OF A SITE WALL WEST OF FLAGLER AND
 A NEW
 SITE WALL AND OR FENCE BUT NO INFORMATION AS TO
 FOOTING, STEEL NOR COLUMN HEIGHT, NOR TO WHAT WIND ZONE
 THIS STRUCTURE WAS DESIGNED TO, NOTE THE CLOSENESS TO
 THE INTERCOASTAL AND ASCE 7-02!!! SITE WALL AND OR
 FENCE PERMITS REQUIRE A SEPERATE PERMIT AND OR REVIEW.
 106.1.2* ADDITIONAL INFORMATION REQUIRED.
  
 5)ADDITIONAL COMMENTS MAY APPEAR FROM VARIOUS TRADES
 ONCE THE FULL SCOPE OF WORK IS DISCLOSED.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-07-17 Cont ID  
Sent By dpalmer Date 2007-07-17 Time 11:12 Rev Time 0.00
Received By dpalmer Date 2007-07-17 Time 11:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-07-03 Cont ID  
Sent By dpalmer Date 2007-07-03 Time 20:14 Rev Time 0.00
Received By dpalmer Date 2007-07-03 Time 19:10 Sent To I
Notes
2007-07-03 20:15:182007-07-03 20:15:18
 ** UNSAT 3RD REVIEW**
  
  
 ** PLEASE KNOW THE E- SHEETS ARE OK, HOWEVER AS THE
 LANDSCAPE PLANS WHICH CONTAIN ELECTRICAL INFORMATION
 CAN NOT BE STAMPED AT THIS TIME.
  
 1) NOTE: PLEASE SEE THE TITLE BLOCK FOR THE LANDSCAPE
 ARCHITECT FIRM IS STILL IN NEED OF SOME CORRECTIONS AND
 INFORMATION.
 PLEASE SEE THE PLANS ARE MISSING THE PRINTED LICENSE #
 OF ARCHITECT.
 PLEASE COORDINATE. PLEASE SEE THE PLANS ARE MISSING THE
 ADDRESS OF PROJECT STILL. (807 N. FLAGLER)
  
  
 2) NOTE: PLEASE SEE THE SEAL IN NOT VALID. FAC
 61G1-16.002
 THIS WAS NOT SEEN ON PREVIOUS REVIEW HOWEVER THIS
 RULING FROM THE FLORIDA ADMINISTRATIVE CODE IS NOT
 NEW.
  
 PLEASE KNOW IF THE ARCHITECT OF RECORD ALREADY HAS NEW
 SEAL OR OBTAINS NEW SEAL THEN A TIME CAN BE SET UP FOR
 THE DESIGNER TO COME INTO THIS OFFICE TO AFFIX NEW
 SEAL, SIGN, DATED AND PLACE INFORMATION ON TITLE
 BLOCKS.
 ** PLEASE SEE MOST OF THE ABOVE COULD EVEN BE HAND
 PRINTED ON PLANS BY THE ARCHITECT. AS THE OFFICE IS
 LOCAL AND CLOSE TO THIS OFFICE, PLEASE CALL TO GO OVER
 THIS IF DESIRED.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2007-07-03 19:11:292007-07-03 19:11:29
 PLANS REMOVED FROM INCOMING, WILL RETURN TO INCOMING
 WAITING FOR COMM BOARD ONCE ELECTRICAL REVIEW IS DONE.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-04-14 Cont ID  
Sent By dpalmer Date 2007-04-14 Time 12:41 Rev Time 0.00
Received By dpalmer Date 2007-04-14 Time 12:06 Sent To  
Notes
2007-04-14 12:41:54** UNSAT **
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH NEW COMMENTS DUE TO
 CHANGES IN PLANS AND NEW RISER NOW SHOWN WHICH WAS NOT
 ON PREVIOUS PLANS.
  
 1) NOTE: PLEASE SEE MISSING COMPLETED INFORMATION ON
 TITLE BLOCKS FOR THE FOLLOWING AS REQUIRED UNDER FAC
 61G1-16.004,FAC 61G15-23.002 -FS 481.219, FS 481.319,
 471.023.
 THESE ITEMS ARE REQUIRED WHETHER OR NOT SHEETS WERE
 STAMPED BY OTHER REVIEWERS OR OTHER TRADES OR COMMENTS
 WERE MADE BY OTHER TRADES OR REVIEWER(S).
 A) PLEASE SEE MISSING INFORMATION FOR ICON DESIGN
 GROUP, WHICH IS MISSING THE PRINTED NAME, PRINTED
 LICENSE NUMBER OF THE DESIGNER OF RECORD. PLEASE ALSO
 SEE THE MISSING LICENSE NUMBERS FOR THE FIRM FOR
 PRACTICING ARCHITECTURAL AND ENGINEERING SERVICE.
 SEE SECTIONS ABOVE OR CONTACT THE STATE OF FLORIDA
 LEGAL COUNSEL TO THE BOARD OF ARCHITECTS AND THE
 FLORIDA BOARD OF ENGINEERS FOR ANY OTHER QUESTIONS.
 B) PLEASE SEE THE SHEETS FOR ENVIRONMENTAL DESIGN GROUP
 WHICH IS MISSING THE FIRM LICENSE NUMBER WHICH IS
 REQUIRED TO BE PRINTED ON THE TITLE BLOCKS. THE SHEETS
 WHICH CONTAINED STAMPS HAVE SINCE BEEN *VOIDED* AS
 THESE SHEETS WILL BE REQUIRED TO BE REVISED TO
 COORDINATE WITH ELECTRICAL PLANS, SEE OTHER COMMENTS.
  
 2) NOTE: PLEASE SEE THE WIND LOAD CALCULATIONS WHICH
 WERE SUBMITTED ARE NOT SIGNED, DATED, SEALED OR
 CONTAINS ANY DESIGNER OF RECORD OR ENGINEERING TITLE
 BLOCK INFORMATION AS REQUIRED.
 PLEASE SEE BUILDING REVIEW COMMENTS FOR THIS ALSO.
 FBC 106.1.2
 FS 471.025, 471.023, FAC 61G15-23.002
  
 3) NOTE: PLEASE CORRELATE RISER AND PANEL SCHEDULE.
 PLEASE SEE PANEL SCHEDULE SHOW THE PANEL AS A 125AMP
 MLO, WHERE RISER INDICATES A 60MCB PANEL?
 PLEASE KNOW IF THIS BREAKER IS GOING TO BE A *BACK-FED*
 DEVICE, THEN THE PANEL SCHEDULE WILL INDICATE WHICH
 SPACE THIS WILL BE LOCATED AND SHALL ALSO INDICATE THE
 REQUIRED REJECTION TYPE DEVICE REQUIRED.
 PLEASE BE SURE TO VERIFY THE AIC RATING FOR
 BACK-FEEDING A BRANCH BREAKER AND DISTANCE FROM FPL.
 110.9, 230,
 FBC 106.1.2
  
 4) NOTE: PLEASE SEE THE PANEL INDICATES LOCATION TO BE
 AT *MARINA* WHICH IS ACTUALLY NOT PART OF THIS LEGAL
 PROPERTY. PLEASE CLARIFY.
 PLEASE ALSO SEE THE SHEETS 1/2 AND 2/2 WHICH ARE DONE
 BY ENVIRONMENTAL DESIGN GROUP NEED TO BE COORDINATED
 WITH THE ELECTRICAL SHEETS INDICATE ALL EQUIPMENT,
 LIGHTING ETC.
  
 ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.
 PLEASE SEE COMMENTS FROM OTHER TRADES WHICH MAY AFFECT
 ANY OTHER SHEETS OR PLANS.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-05 Cont ID  
Sent By dpalmer Date 2007-03-05 Time 11:55 Rev Time 0.00
Received By dpalmer Date 2007-03-05 Time 11:55 Sent To  
Notes
2007-03-05 11:55:46*** UNSAT ***
  
 1) NOTE: PLEASE PROVIDE MORE INFORMATION ON HOW AND
 WHERE THE ELECTRICAL IS BEING FED FROM.
 PLEASE SHOW MORE INFORMATION ON WIRING, OVER CURRENT
 PROTECTION, GROUNDING ETC.
 PLEASE SUBMIT INFORMATION ON WIND LOADS FOR LIGHT POLES
 WHICH ARE REQUIRED TO SHOW THE LOADS ON POLES WITH THE
 EPA OF THE FIXTURES TO MEET THE FBC 140 MPH.*WIND LOADS
 WILL BE REVIEWED BY THE STRUCTURAL REVIEWER.
 FBC 106.1.2, 106.3.5.1.2
 NEC 240.4, 310.16, 220, 215.5 ETC.
  
 2) NOTE: PLEASE SEE THAT PLANS MENTIONS THAT THE LIGHTS
 ARE A CONTINUATION OF THE PALM BEACH YACHT CLUB,
 HOWEVER THIS IS BEING SHOWN AS A SEPARATE LEGAL
 PROPERTY. PLEASE KNOW THAT THE ELECTRICAL MAY NOT BED
 FED FROM THE OTHER LEGAL PROPERTY AND CROSS PROPERTY
 LINES AS SUBMITTED AND SHOWN.
 PLEASE CLARIFY THIS AND SEE NOTE #1.
  
 3) NOTE: PLEASE KNOW THE PERMIT TYPE WILL CHANGE AS
 THIS IS NOT A DRIVEWAY PERMIT.
  
 4) NOTE: PLEASE SUBMIT A RECORDED NOTICE OF
 COMMENCEMENTS FOR PROJECT. THIS WAS NOT ON FILE AND WAS
 NOT ON RECORD AS EVER BEING SUBMITTED.
 FS 713.13
  
 5) NOTE: PLEASE KNOW THAT A HOLD HAS BEEN PLACED ON
 PERMIT FOR INSPECTIONS AS SCOPE, ADDITIONAL FEES,
 REVIEWS AND PLANS NEED TO BE ADDRESSED.
  
 6) NOTE: PLEASE KNOW THAT ALL PLANS/SHEETS AND
 DOCUMENTS SHALL CONTAIN A TITLE BLOCK FOR THE DESIGNER
 OF RECORD WHICH HAS SIGNED AND SEALED PLANS.
 FAC 61G15-23.002, FAC 61G1-16.004
 FS 481.219, AND FS 471.023
  
 7) NOTE: PLEASE SEE SHEETS SIGNED AND SEALED BY THE
 LANDSCAPE ARCHITECT SHALL ALSO BE DATED BY THE
 ARCHITECT AT THE TIME WHEN SIGNING PLANS.
 FS 481.221.
  
 8) NOTE: PLEASE SEE THAT THE SCOPE OF WORK ON THE
 SCHOOL SIDE OF THE STREET MAY BE REQUIRED TO BE UNDER A
 SEPARATE PERMIT. THIS HAS YET TO BE CONFIRMED.
  
 ** PLEASE KNOW THAT AS OF THIS TIME DUE TO THE
 ELECTRICAL PLANS SUBSTANTIALLY CHANGING THERE MAY BE
 NEW COMMENTS ON THE NEXT REVIEW.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2007-07-27 Cont ID  
Sent By rchokshi Date 2007-07-27 Time 08:02 Rev Time 0.00
Received By rchokshi Date 2007-07-27 Time 08:02 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2007-05-25 Cont ID  
Sent By rchokshi Date 2007-05-25 Time 11:17 Rev Time 0.00
Received By rchokshi Date 2007-05-25 Time 11:13 Sent To  
Notes
2007-05-25 11:17:35 
 FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE ON DRAWING TOTAL SITE AREA,PERVIOUS
 AREA,IMPERVIOUS AREA.ETC.
 2. PLEASE SHOW ON DRAWING POLLUTION PREVENTION
 DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT
 FENCE AROUND THE SITE
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2007-03-08 Cont ID  
Sent By rchokshi Date 2007-03-08 Time 14:53 Rev Time 0.00
Received By rchokshi Date 2007-03-08 Time 14:37 Sent To  
Notes
2007-03-08 14:53:02PLEASE PROVIDE FOLLOWING INFO:
  
 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON
 DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY,
 PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,,
 MUST MEET PER ADA,,ETC.,ALL CITY STANDARDSNOTES
 AVAILABLE IN C.D. AT 1000 45TH STREET, ENG DEPT.
 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD ,
 SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW
 ON THE DRAWINGS.
 4. PLEASE PROVIDE A COPY OF GEO-TECH REPORT,
 5.IN YOUR STORM WATER CALCULATIONS, WHY YOU DO NOT TAKE
 TOTAL 0.49 ACRE?, AND WHY NOT TAKE 0.04 ACRE-FT TO
 CALCULATE LENGTH OF EXFILTRATION TRENCH INSTEAD OF 0.02
 AC-FT? LOOKS LIKE YOU NEED MUCH LONGER EXFILTRATION
 TRENCH THAN YOU CALCULATED..
 6. PLEASE PROVIDE IN DETAILFOR TOTAL SITE
 AREA,PERVIOUS AREA,IMPERVIOUS AREA.ETC.
 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR
 SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES
 AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO
 CONNECT WITH THE STORM WATERFROM ALL OTHER STORM
 WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL
 STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ?
 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT
 ETC., PLANS SHOWING SILT FENCE AROUND THE SITE
 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH
 STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED
 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN.
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2007-06-01 Cont ID  
Sent By mawillia Date 2007-06-01 Time 11:20 Rev Time 0.00
Received By mawillia Date 2007-06-01 Time 11:18 Sent To  
Notes
2007-06-01 11:20:36PLEASE SEE COMMENT FROM 1ST FIRE REVIEW DATED
 03/30/2007

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2007-03-30 Cont ID  
Sent By mwennerg Date 2007-03-30 Time 14:59 Rev Time 0.00
Received By mwennerg Date 2007-03-30 Time 14:59 Sent To  
Notes
2007-03-30 15:01:19INFORMATION SUBMITTED WOULD NOT APPEAR TO REQUIRE A
 FIRE PLAN REVIEW AT THIS TIME.

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-02-28 Cont ID  
Sent By adarroug Date 2008-02-28 Time 08:28 Rev Time 0.00
Received By adarroug Date 2008-02-28 Time 08:28 Sent To Z
Notes
2008-02-28 08:28:26TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-06-24 Cont ID  
Sent By adarroug Date 2007-06-24 Time 12:49 Rev Time 0.00
Received By adarroug Date 2007-06-24 Time 12:49 Sent To  
Notes
2007-07-09 14:50:17TO "COMM" BD#32
2007-06-24 12:49:59WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-04-09 Cont ID  
Sent By adarroug Date 2007-04-09 Time 14:43 Rev Time 0.00
Received By adarroug Date 2007-04-09 Time 14:43 Sent To  
Notes
2007-04-09 14:45:17TO "COMM" BD#20

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-03-05 Cont ID  
Sent By dpalmer Date 2007-03-05 Time 11:56 Rev Time 0.00
Received By dpalmer Date 2007-03-05 Time 11:56 Sent To  
Notes
2007-03-05 11:56:17TO COMM BOARD #58

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-02-21 Cont ID  
Sent By adarroug Date 2007-02-21 Time 10:07 Rev Time 0.00
Received By adarroug Date 2007-02-21 Time 10:07 Sent To Z
Notes
2007-02-21 10:07:36TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-23 Cont ID  
Sent By adarroug Date 2006-09-23 Time 17:41 Rev Time 0.00
Received By adarroug Date 2006-09-23 Time 17:41 Sent To Z
Notes
2006-09-23 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-09 Cont ID  
Sent By adarroug Date 2006-02-09 Time 15:20 Rev Time 0.00
Received By adarroug Date 2006-02-09 Time 15:19 Sent To Z
Notes
2006-02-09 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-22 Cont ID  
Sent By adarroug Date 2005-12-22 Time 11:51 Rev Time 0.00
Received By astelly Date 2006-01-09 Time 09:51 Sent To Z
Notes
2005-12-22 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-22 Cont ID  
Sent By adarroug Date 2005-12-08 Time 11:51 Rev Time 0.00
Received By adarroug Date 2005-11-29 Time 13:22 Sent To  
Notes
2005-11-29 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status N Date 2007-05-29 Cont ID  
Sent By kstevens Date 2007-05-29 Time 12:41 Rev Time 0.00
Received By kstevens Date 2007-05-29 Time 12:41 Sent To  
Notes
2007-05-29 12:42:12 
 REFERENCE: FBC-2004 CHAPTER 1
  
 1. SEPARATE PLANS/PERMIT REQUIRED FOR THE IRRIGATION.
 SECTION 105.1. PLANS SHALL SHOW ALL PIPING, THE
 LOCATION OF THE METER, THE BACKFLOW, (PLUMBING PERMIT
 REQUIRED TO TIE INTO THE POTABLE WATER), THE
 CONTROLLER, AND A RAIN SENSOR.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-05-09 Cont ID  
Sent By kstevens Date 2007-03-21 Time 16:13 Rev Time 0.00
Received By kstevens Date 2007-03-21 Time 16:13 Sent To  
Notes
2007-03-21 16:36:31DENIED
 REFERENCE: FBC-2004 CHAPTER 1
  
 1. SEPARATE PLANS/PERMIT REQUIRED FOR THE IRRIGATION.
 SECTION 105.1. PLANS SHALL SHOW ALL PIPING, THE
 LOCATION OF THE METER, THE BACKFLOW, (PLUMBING PERMIT
 REQUIRED TO TIE INTO THE POTABLE WATER), THE
 CONTROLLER, AND A RAIN SENSOR.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 7 Status P Date 2008-03-04 Cont ID  
Sent By astelly Date 2008-03-04 Time 16:32 Rev Time 0.00
Received By astelly Date 2008-03-04 Time 16:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 6 Status F Date 2007-07-23 Cont ID  
Sent By astelly Date 2007-07-23 Time 16:44 Rev Time 0.00
Received By astelly Date 2007-07-23 Time 16:43 Sent To  
Notes
2007-07-23 17:02:08AMY STELLY
 URBAN DESIGN
 822-1440
  
 PLEASE REVISE THE CURRENT DRAWINGS AND PROVIDE
 ADDITIONAL DRAWINGS AS NECESSARY TO REFLECT THE
 FOLLOWING COMMENTS FROM BRIAN COLLINS:
  
 1.NEED ADVANCE CROSSING SIGNAGE - S1-1 PLUS W16-9P
 (FYG - RETROREFLECTIVE) BOTH NORTH AND SOUTH
 2.SHOW CROSSING SIGNAGE ON NB FLAGLER
 3.SHOW DETAILS FOR ALL SIGNS
 4.STAMPED CONCRETE OR PAVER BRICKS SHOULD BE USED TO
 FILL MEDIAN.
 5.EUROPEAN CROSSWALK DETAIL SHOULD REFLECT FLAGLER
 CROSS SECTION, MEDIAN, AND YIELD LINE NOT STOP BAR.
 6.CROSSWALK ON PLANS DOES NOT SHOW IN-GROUND LIGHTS
 7.BLOW -UP OF CROSSWALK DETAIL AND IN-GROUND LIGHTS
 SHOULD BE PROVIDED
 8.SINCE THERE IS ADDITIONAL LANE WIDTH DUE TO REMOVAL
 OF LTL LANE AT 1 WATERMARK, EXTEND MEDIAN 30 FT. TO
 SOUTH.THIS WOULD HELP DETER ILLEGAL LEFTS FROM THE
 NEW PARKING AREA ON THE EAST SIDE OF FLAGLER.
 9.MEDIAN NORTH OF CROSSWALK MAY BE REDUCED FROM 35 TO
 20FT.TO ALLOW ACCESS TO YACHT CLUB AND PARKING AREA.
 10.TRAFFIC SEPARATORS DETAILS ARE A LITTLE TOUGH TO
 READ.
 11.ADD NO U-TURN SIGNAGE (R3-4) AT NORTH AND SOUTH
 ENDS OF ISLAND.
 12.TEMPORARY PAVEMENT MARKINGS SHALL BE INSTALLED
 AFTER THE FINAL LIFT OF ASPHALT IS COMPLETED UNTIL THE
 PERMANENT (THERMOPLASTIC) MARKINGS ARE INSTALLED.
  

Review Stop Z ZONING
Rev No 5 Status P Date 2007-03-01 Cont ID  
Sent By astelly Date 2007-03-01 Time 10:15 Rev Time 0.00
Received By astelly Date 2007-03-01 Time 10:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2006-09-27 Cont ID  
Sent By astelly Date 2006-09-27 Time 16:50 Rev Time 0.00
Received By astelly Date 2006-09-27 Time 16:50 Sent To  
Notes
2006-09-27 00:00:00PLEASE SUBMIT SITE AND LANDSCAPE PLANS
 FOR REVIEW WITH REVISED ELECTRICAL.
 REVISED ELECTRICAL MUST INCLUDE PLANS
 AND SPECIFICATIONS FOR THE PEDESTRIAN
 CROSSWALK LIGHTING. THIS IS A STANDING
 CONDITION OF THE DAC APPROVAL.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-02-22 Cont ID  
Sent By astelly Date 2006-02-22 Time 17:46 Rev Time 0.00
Received By astelly Date 2006-02-22 Time 17:46 Sent To  
Notes
2006-02-22 00:00:00PROVISO: ENGINEERING DRAWINGS FOR
 RIGHT-OF-WAY IMPROVEMENTS MUST MEET THE
 SPECIFICATIONS AND APPROVAL OF THE CITY
 TRAFFIC ENGINEER. SEE ITEMS 19, 20,
 21,23, 24, 25 ON THE APPROVED SITE AND
 HARDSCAPE PLAN.
  
 DRAWINGS FOR THE DESIGN OF THE SIGN,
 ITEM 18 ON THE APPROVED SITE AND
 HARDSCAPE PLAN, MUST BE MUST BE
 SUBMITTED FOR PERMITTING PRIOR TO
 INSTALLATION.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-01-09 Cont ID  
Sent By astelly Date 2006-01-09 Time 09:52 Rev Time 0.00
Received By astelly Date 2006-02-22 Time 17:45 Sent To  
Notes
2006-01-09 00:00:00PLEASE RESUBMIT WITH CROSSWALK SAFETY
 DETAILS.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-08 Cont ID  
Sent By astelly Date 2005-12-08 Time 16:52 Rev Time 0.00
Received By astelly Date 2005-12-08 Time 16:52 Sent To  
Notes
2005-12-08 00:00:00NEED TO RESUBMIT UPDATED PLANS AS PER
 DAC REVIEW


Account Summary | Usage Policy | Privacy Policy