Plan Review Stops For Permit 05110804 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-14 |
Time |
13:51 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2005-12-14 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-03-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-03-03 |
Time |
07:18 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-03-03 |
Time |
06:45 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-09 |
Time |
10:40 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-12-09 |
Time |
10:20 |
Sent To |
M |
|
Notes |
2005-12-09 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE CITY OF WEST PALM BEACH HAS | | ADOPTED A POLICY FOR GENERATORS THAT IS | | ATTACHED. THE LOAD CALCULATION MUST BE | | DERIVED FROM 220.31. | | | | 2} PLEASE SUBMIT A SITE PLAN SHOWING THE | | LOCATION OF ALL SERVICE AND GENERATOR | | EQUIPMENT SO THAT COMPLIANCE WITH | | 225.31-39 CAN BE DETERMINED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-03-03 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-03-03 |
Time |
13:01 |
Sent To |
B |
|
Notes |
2006-03-03 00:00:00 | PLEASE SEE PLAN REVIEW NOTES ON GAS | | PERMIT # 06020371 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-14 |
Time |
13:22 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-12-14 |
Time |
13:22 |
Sent To |
B |
|
Notes |
2005-12-14 00:00:00 | GAS PERMIT REQUIRED. GAS CONTRACTOR TO | | SUBMIT PLANS WITH PERMITAPPLICATION. ALL | | GAS INSPECTIONS TO BE COMPLETE BEFORE | | FINAL RES-GEN INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-08-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-26 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-26 |
Time |
16:19 |
Sent To |
Z |
|
Notes |
2006-08-26 00:00:00 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-02-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-19 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-19 |
Time |
11:52 |
Sent To |
E |
|
Notes |
2006-02-19 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-07 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-07 |
Time |
10:18 |
Sent To |
E |
|
Notes |
2005-12-07 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-14 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-11-28 |
Time |
08:34 |
Sent To |
|
|
Notes |
2005-11-28 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-12-12 |
Time |
16:41 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2005-12-12 |
Time |
16:41 |
Sent To |
P |
|
Notes |
2005-12-12 00:00:00 | *** PROVISO *** | | 1) GENERATOR EXHUST MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | TEN FEET AWAY FROM ADJECENT BUILDING | | OPENS. | | 2) DETAILED MANUFACTURE'S | | SPECIFICATION'S AND INSTALLATION | | INSTRUCTIONS MUST BE ON JOB SITE. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-03-03 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2006-03-03 00:00:00 | NO PLUMBING THIS PERMIT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-14 |
Time |
13:22 |
Rev Time |
|
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-09-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-02 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-09-02 |
Time |
09:33 |
Sent To |
|
|
Notes |
2006-09-02 00:00:00 | REVISION - CHANGE OF LOCATION | | (GENERATOR) |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-12-06 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-12-06 |
Time |
15:44 |
Sent To |
I |
|
Notes |
2005-12-06 00:00:00 | NOTE: GENERATOR CAN ONLY ENCROACH 4FT | | INTO A SETBACK. |
|
|