Plan Review Details - Permit 05110768
Plan Review Stops For Permit 05110768
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-07-18 Cont ID  
Sent By amorse Date 2006-07-18 Time 09:57 Rev Time 0.50
Received By amorse Date 2006-07-18 Time 09:57 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-08 Cont ID  
Sent By amorse Date 2006-06-08 Time 11:29 Rev Time 0.50
Received By amorse Date 2006-06-08 Time 11:29 Sent To  
Notes
2006-06-08 00:00:00 
  
 DENIED
  
 1) WINDOW PRODUCT APPROVALS ARE FOR NON-
 IMPACT AND WILL REQUIRE IMPACT
 PROTECTION DEVICES. PLEASE SUBMIT
 PRODUCT APPROVALS FOR STORM SHUTTERS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-08 Cont ID  
Sent By amorse Date 2006-04-05 Time 11:27 Rev Time 0.50
Received By amorse Date 2006-04-05 Time 11:26 Sent To  
Notes
2006-06-08 00:00:00 
  
  
 DENIED
  
 1) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
  
 2) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION
  
 3) AWNINGS SHALL BE SUBMITTED UNDER A
 SEPERATE PERMIT APPLICATION
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-19 Cont ID  
Sent By amorse Date 2005-12-19 Time 14:40 Rev Time 1.00
Received By amorse Date 2005-12-19 Time 14:40 Sent To PC
Notes
2005-12-19 00:00:00 
  
 DENIED
  
 1) THE NEW FRONT ENCLOSURE IS AN
 ADDITION AND AS SUCH SHALL COMPLY WITH
 THE PROVSIONS OF THE 2004 FL BLDG CODE
 REMOVE GENERAL NOTE THAT SPEC'S UBC
  
 2) WINDOWS SHALL BE IMPACT RESISTANT OR
 MUST BE PROTECTED WITH APPROVED IMPACT
 RESISTANT COVERINGS AS PER 1609.1.4 2004
 FBC
  
 3) SUBMIT FRAMING DETAILS THAT SHOW
 BACKING FOR STORM PANELS
  
 4) SUBMIT DOOR AND WINDOW SIZES
  
 5) SUBMIT DETAILS OF THE ROOF AND WALL
 FRAMING ATTACHMENT TO EXISTING
  
 6) SUBMIT DETAILS ON ALL FRAMING
 CONNECTORS FOR STRAPPING/ANCHORING
  
 7) SUBMIT AN ANCHOR SCHEDULE IN LIEU OF
 PRODUCT APPROVALS FOR EACH CONNECTOR
 BEING USED. SHOW THE APPROVED
 MANUFACTURER,TYPE,SIZE,ETC. OF EACH
 CONNECTOR
  
 8) ROOFS WITH A PITCH FROM 2/12 TO 4/12
 REQUIRE DOUBLE UNDERLAYMENT PER 905.2.7
 2004 FBC RES.
  
 9) SUBMIT 2 COPIES OF THE PRODUCT
 APPROVALS COMPLETE WITH THE FLORIDA
 STATE APPROVAL COVER SHEETS AND PRODUCT
 NOA'S. ROOFING AND STORM PANELS ALSO
 REQUIRE PRODUCT APPROVAL
  
 10) SUBMIT FOUNDATION PLAN, SHOW IF THE
 FOUNDATION IS NEW OR EXISTING
  
 11) FRONT DOOR AWNING SHALL COMPLY WITH
 3105. 2004 FBC AND 2 COPIES OF PRODUCT
 APPROVAL SHALL BE SUBMITTED
  
 12) SUBMIT 2 COPIES OFF ALL REQUIRED
 DRAWINGS SIGNED BY THE PARTY RESPONSIBLE
 FOR THE DRAWINGS THAT INDICATE
 COMPLIANCE WITH THE 2004 FL BLDG CODE
  
 13) NOTE THAT IF A FLOOR PLAN WITH
 ELECTRICAL IS NOT SUBMITTED AN
 ADDITIONAL PERMIT WILL BE REQUIRED
  
 14) SUBMIT A RECORDED NOTICE OF
 COMMENCEMENT PRIOR TO A PERMIT BEING
 ISSUED
  
 15) PALM BEACH COUNTY IMPACT FEES ARE
 REQUIRED, THE 2 SETS OF PLANS SHALL BE
 STAMPED BY THEM AND A COPY OF THE
 RECEIPT SUBMITTED TO WPB CONSTRUCTION
 SERVICES
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-06-08 Cont ID  
Sent By btrobaug Date 2006-06-08 Time 14:05 Rev Time 0.50
Received By btrobaug Date 2006-06-08 Time 14:05 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-08 Cont ID  
Sent By btrobaug Date 2006-03-20 Time 14:04 Rev Time 0.50
Received By btrobaug Date 2006-03-20 Time 14:02 Sent To  
Notes
2006-06-08 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} 210.52(A) GENERAL PROVISIONS. IN
 EVERY KITCHEN, FAMILY ROOM, DINING ROOM,
 LIVING ROOM, PARLOR, LIBRARY, DEN,
 SUNROOM, BEDROOM, RECREATION ROOM, OR
 SIMILAR ROOM OR AREA OF DWELLING UNITS,
 RECEPTACLE OUTLETS SHALL BE INSTALLED IN
 ACCORDANCE WITH THE GENERAL PROVISIONS
 SPECIFIED IN 210.52(A)(1) THROUGH
 (A)(3).
 (1) SPACING. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED
 HORIZONTALLY ALONG THE FLOOR LINE IN ANY
 WALL SPACE IS MORE THAN 1.8 M (6 FT)
 FROM A RECEPTACLE OUTLET.
  
 PLEASE HAVE THE PERSON RESPONSIBLE FOR
 DRAWING THE PLAN PRINT AND SIGN THEIR
 NAME TO SAME.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-06 Cont ID  
Sent By adarroug Date 2006-06-06 Time 12:05 Rev Time 0.00
Received By adarroug Date 2006-06-06 Time 12:05 Sent To B
Notes
2006-06-06 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-27 Cont ID  
Sent By adarroug Date 2006-05-27 Time 13:06 Rev Time 0.00
Received By adarroug Date 2006-05-27 Time 13:06 Sent To Z
Notes
2006-05-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-07 Cont ID  
Sent By adarroug Date 2005-12-07 Time 10:03 Rev Time 0.00
Received By adarroug Date 2005-12-07 Time 10:03 Sent To B
Notes
2005-12-07 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-27 Cont ID  
Sent By adarroug Date 2005-12-19 Time 13:05 Rev Time 0.00
Received By adarroug Date 2005-11-28 Time 09:58 Sent To  
Notes
2005-11-28 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-04 Cont ID  
Sent By mmclean Date 2006-06-04 Time 10:14 Rev Time 0.00
Received By mmclean Date 2006-06-04 Time 10:14 Sent To I
Notes
2006-06-04 00:00:00THE PROPOSED ENCLOSED PORCH SITS BEYOND
 THE 25FT FRONT SETBACK AND SIDE SETBACK
 IS MORE THAT 5FT.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-06 Cont ID  
Sent By mmclean Date 2005-12-06 Time 17:39 Rev Time 0.00
Received By mmclean Date 2005-12-06 Time 17:39 Sent To I
Notes
2005-12-06 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF PLANS
 SHOWING THE SURVEY/SITEPLANS/ELEVATION
 PLANS ETC. (BOTHS SETS TO BE STAMPED AND
 A COPY ATTACH WITH APPLICATION FOR FILE
 WITH THE DEPT (CONSTRUCTION SERVICES).
 ONLY 1 SET WAS SUBMITTED.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720