Plan Review Details - Permit 05110338
Plan Review Stops For Permit 05110338 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-15 |
Time |
09:43 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2005-12-15 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-03-02 |
Time |
15:41 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-03-02 |
Time |
15:21 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-09 |
Time |
07:55 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-12-09 |
Time |
07:45 |
Sent To |
M |
|
Notes |
2005-12-09 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE CITY OF WEST PALM BEACH HAS | | ADOPTED A POLICY FOR GENERATORS THAT IS | | ATTACHED. THE LOAD CALCULATION MUST BE | | DERIVED FROM 220.31. | | | | 2} PLEASE SUBMIT A SITE PLAN SHOWING THE | | LOCATION OF ALL SERVICE AND GENERATOR | | EQUIPMENT SO THAT COMPLIANCE WITH | | 225.31-39 CAN BE DETERMINED. | | | | THE PERMIT VALUE MUST INCLUDE THE COST | | OF ALL LABOR AND MATERIAL IF APPLYING | | FOR A GEN RES PERMIT. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-15 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2005-12-15 |
Time |
09:06 |
Sent To |
B |
|
Notes |
2005-12-15 00:00:00 | GAS PERMIT REQUIRED. GAS CONTRACTOR TO | | SUBMIT PLANS WITH PERMIT APPICATION. ALL | | GAS INSPECTIONS TO BE COMPLETE BEFORE | | FINAL RES-GEN. INSPECTON. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-02-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-19 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-19 |
Time |
11:51 |
Sent To |
E |
|
Notes |
2006-02-19 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-12-09 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-12-09 |
Time |
09:27 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2005-12-09 |
Time |
09:27 |
Sent To |
P |
|
Notes |
2005-12-09 00:00:00 | *** PROVISO *** | | 1) GENERATOR EXHUST MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | TEN FEET AWAY FROM ADJECENT BUILDING | | OPENS. | | 2) DETAILED MANUFACTURE'S | | SPECIFICATION'S AND INSTALLATION | | INSTRUCTIONS MUST BE ON JOB SITE. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-15 |
Time |
09:05 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-12-15 |
Time |
09:05 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-12-14 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-12-14 |
Time |
07:17 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-11-21 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-11-21 |
Time |
15:48 |
Sent To |
I |
|
Notes |
2005-11-21 00:00:00 | DENIED, | | 1. MUST PROVIDE A COMPLETE SURVEY | | SHOWING THE FRONT OF THE PROPERTY WITH | | SETBACK. | | 2. MUST MEET THE REQUIRED SETBACK BEYOND | | THE 25FT FRONT SETBACK OF PROPERTY. | | 3. GENERATOR CAN ONLY ENCROACH 4FT INTO | | A SETBACK. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |