Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-10-16 Cont ID  
Sent By lmartine Date 2006-10-16 Time 17:11 Rev Time 0.00
Received By lmartine Date 2006-10-16 Time 17:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-17 Cont ID  
Sent By shill Date 2006-03-17 Time 09:22 Rev Time 0.00
Received By shill Date 2006-03-17 Time 09:22 Sent To  
Notes
2006-03-17 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
  
 1.)THIS IS A PLAN CHECK ONLY.PLANS
 APPEAR CODE COMPLIANT.SUBMIT FOR
 PERMIT.WHEN SUBMITTING, PLEASE PROVIDE
 BOTH STAMPED COPIES.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-11-23 Cont ID  
Sent By shill Date 2005-11-23 Time 10:05 Rev Time 3.00
Received By shill Date 2005-11-21 Time 12:00 Sent To PC
Notes
2005-11-23 00:00:00****CORRECTIONS****
 ****PLAN REVIEW ONLY***
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 1.)SIGNED, SEALED, AND DATED ORIGINALS
 REQUIRED.
  
 2.)THE PRINTED NAME AND LICENSE NUMBER
 OF THE PERSON SEALING THE DOCUMENT IS TO
 BE ON THE PLAN, FAC61G15-23.002.
  
 3.)US ARMY CORP OF ENGINEERS PERMIT
 REQUIRED.561-472-3500.IF THE WORK IS
 TO BE DONE UNDER A NATIONWIDE 3 PERMIT,
 SHOW COMPLIANCE WITH ALL REQUIREMENTS ON
 THE PLAN.IF THE WORK DOES NOT COMPLY
 WITH THE REQUIREMENTS OF NATIONWIDE 3,
 PROVIDE US ARMY CORP APPROVAL FOR THIS
 PROJECT.
  
 HTTP://WWW.SAJ.USACE.ARMY.MIL/PERMIT/
 PERMITTING/NWP/NW_NCA/NW-TABLE.HTML
  
 4.)INDICATE GOVERNING CODE (FBC2004).
  
 5.)THE OPENING SPACE OF 6"
 BETWEEN CABLES DOES NOT COMPLY WITH THE
 4" REQUIREMENT OF FBC1012.SEE
 FBC407.3.3 EXISTING BUILDING CODE AND
 SHOW COMPLIANCE ON THE
 PLAN.
  
 6.)THE GUARDRAIL IS TO COMPLY WITH
 FBC1607.7.1; PROVIDE DESIGN CRITERIA ON
 THE PLAN.
  
 7.)THE RAMP IS TO BE ACCESSIBLE.
 PROVIDE THE RAMP SLOPE AND A DETAIL FOR
 COMPLIANT HANDRAILS IF REQUIRED,
 FBC11-4.26.
  
 8.)PROVIDE INFORMATION IN REGARDS TO
 THE RAMP AND PIER SURFACE,
 FBC11-4.1.2(4), FBC11-4.5.
  
 9.)SPECIFY LIVE LOAD DESIGN,
 FBC1603.1.1.
  
 10.)PROVIDE WIND DESIGN DATA,
 FBC1603.1.4.
  
 11.)PROVIDE TOTAL FISHING PIER LENGTH.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-10 Cont ID  
Sent By rbrown Date 2006-02-10 Time 14:35 Rev Time 0.00
Received By rbrown Date 2006-02-10 Time 14:35 Sent To  
Notes
2006-02-10 00:00:00TO SAMANTHA HILL DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-11-21 Cont ID  
Sent By shill Date 2005-11-21 Time 17:14 Rev Time 0.00
Received By shill Date 2005-11-18 Time 08:19 Sent To  
Notes
2005-11-18 00:00:00TO "SHILL" DESK