Plan Review Details - Permit 05100904
Plan Review Stops For Permit 05100904
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-03-30 Cont ID  
Sent By alange Date 2006-03-30 Time 10:10 Rev Time 1.75
Received By alange Date 2006-03-30 Time 09:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-02-24 Cont ID  
Sent By tgordon Date 2006-03-24 Time 14:47 Rev Time 2.50
Received By alange Date 2006-02-24 Time 13:35 Sent To  
Notes
2006-02-24 00:00:00DENIED
 1. 713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 2.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS.
  
 3.ALL PLANS SUBMITTED AFTER OCTOBER 1,
 2005 SHALL BE DESIGNED TO THE 2004 FBC.
 BUILDING CODE USED IS THE 2004
 RESIDENTIAL CODE AND THE 2004 FBC, CODE
 REFERENCES SHOULD REFLECT THOSE CODES.
  
 4.SUBMIT ENERGY CALCS TO THE 2004 FBC.
  
  
 7.SUBMIT GUARD RAIL DETAILS PER
 R-312.1 NO DETAILS SUBMITTED, ONLY CODE
 SECTIONS.
  
 8.SELECT THE ASSEMBLY USED FOR THE
 BITUMEN ROOF AND INCLUDE ONLY THE PAGES
 REQUIRED FOR THAT ASSEMBLY.
  
 NEW COMMENT:
 THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMMENDMENT TO FBC 106.3.3
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-23 Cont ID  
Sent By alange Date 2005-12-23 Time 09:54 Rev Time 4.00
Received By alange Date 2005-12-23 Time 09:38 Sent To  
Notes
2005-12-23 00:00:00DENIED
 1. 713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 2.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS.
  
 3.ALL PLANS SUBMITTED AFTER OCTOBER 1,
 2005 SHALL BE DESIGNED TO THE 2004 FBC.
  
 4.SUBMIT ENERGY CALCS TO THE 2004 FBC.
  
 5.ENERGY CALCS DO NOT MATCH R- VALUES
 ON PLANS.
  
 6.SUBMIT SPECS FOR HOOD AND GAS BBQ.
 A HOOD IS REQUIRED FOR BUILT IN UNITS.
  
 7.SUBMIT GUARD RAIL DETAILS PER
 R-312.1
  
 8.SUBMIT PRODUCT APPROVAL FOR BITUMEN
 ROOF WITH THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 9.PLEASE CLARIFY... IS THE ULTIMATE
 DOOR TO BE USED IN THE FRONT ENTRY?
 IF IT IS A DIFFERENT DOOR SUBMIT A
 PRODUCT APPROVAL FOR THAT PRODUCT.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-08-15 Cont ID  
Sent By btrobaug Date 2007-08-15 Time 16:49 Rev Time 0.00
Received By btrobaug Date 2007-08-15 Time 16:36 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-08-01 Cont ID  
Sent By btrobaug Date 2007-08-01 Time 11:19 Rev Time 0.00
Received By btrobaug Date 2007-08-01 Time 09:50 Sent To PC
Notes
2007-08-01 11:17:03 
  
 REVISION DENIED/INCOMPLETE INFORMATION
  
  
 1} PROVIDE A PANEL SCHEDULE FOR ADDED PANEL "C".
  
 2} PANEL "C" IS NOT ON THE RISER DIAGRAM, PLEASE ADD
 SAME.
  
 3} THE CONDENSER LABELED AC #3 IS IN BOTH PANEL "A" AND
 "EM", AND THE LOAD IN EACH IS DIFFERENT. PLEASE CORRECT
 TO SHOW ACTUAL CONDITIONS.
  
 4} LOCATE THE DISCONNECT FOR AC #3, 440.14.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-22 Cont ID  
Sent By btrobaug Date 2006-03-22 Time 16:48 Rev Time 0.75
Received By btrobaug Date 2006-03-22 Time 16:15 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-02-21 Cont ID  
Sent By btrobaug Date 2006-02-21 Time 08:44 Rev Time 0.75
Received By btrobaug Date 2006-02-21 Time 07:05 Sent To M
Notes
2006-02-21 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT THE MANUFACTURERS
 SPECIFICATIONS FOR THE GEN SET AND ALL
 RELATED EQUIPMENT. NOTE THE TRANSFER
 SWITCH MUST BE SERVICE RATED PER 225.36.
 ALL ARTICLE 225 APPLIES TO THE
 GENERATOR, AS WELL AS 445, 700 & 702.
 THIS COMMENT WAS MEDE ON THE PREVIOUS
 REVIEW.
  
 2} THE CALCULATION FOR THE "EM" PANEL IS
 NOT PER ANY RECOGNIZED FORMULAS IN THE
 NEC. THERE IS NO CALC FOR 1WATT PER
 SQUARE FOOT. IT WAS INDICATING THAT HEAT
 WOULD NOT BE USED WITH EMERGENCY POWER.
 INDICATE HOW THE A/C WOULD BE EXCLUDED
 (LOCKED OUT) WHEN THE GENERATOR POWERS
 UP. IT WOULD APPEAR THAT WITH AN
 AUTOMATIC TRANSFER SWITCH OPERATION ALL
 BRANCH CIRCUITS IN THE "EM" PANEL WOULD
 BE ENERGIZED. SUGGEST REMOVING ALL LOADS
 FROM THAT PANEL NOT INTENDED TO BE
 ENERGIZED BY THE GEN SET.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-11-10 Cont ID  
Sent By btrobaug Date 2005-11-10 Time 06:46 Rev Time 1.00
Received By btrobaug Date 2005-11-09 Time 17:52 Sent To M
Notes
2005-11-09 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT THE MANUFACTURERS
 SPECIFICATIONS FOR THE GEN SET AND ALL
 RELATED EQUIPMENT. NOTE THE TRANSFER
 SWITCH MUST BE SERVICE RATED PER 225.36.
 ALL ARTICLE 225 APPLIES TO THE
 GENERATOR, AS WELL AS 445, 700 & 702.
  
 2} THE FEEDER FROM THE GENERATOR MUST BE
 115% OF THE NAMEPLATE PER 445.13.
  
 3} THE GROUNDING ELECTRODE SYSTEM MUST
 BE ATTACHED AT THE METER OR THE FIRST
 MEANS OF DISCONNECT, IT MUST BE REMOVED
 FROM THE ATS. THE ATS SHOULD BE BONDED
 WITH THE EQUIPMENT GROUNDING CONDUCTOR,
 UNLESS THE GENERATOR IS A SEPERATLY
 DERIVED SYSTEM.
  
 4} PLEASE PROVIDE A LOAD SUMMARY FOR THE
 EMERGENCY LOAD.
  
 5} THE DINING ROOM RECEPTACLES MUST
 COMPLY WITH 210.52(B)(1 & 2), NO OTHER
 OUTLETS, SEE GALLERY AND FOYER.
  
 6}THE GFI'S IN THE MASTER BATH ARE SHOWN
 ON INCORRECT CIRCUITS. ONE IS SHOWN ON
 "C 17" (NO SUCH PANEL ON THE PLAN), THE
 OTHER ON "EM 7". PLEASE SEE 210.11(C(3).
  
 7} PLEASE SEE THE CIRCUIT FOR THE FAMILY
 ROOMEXTENDS TO A RECEPTACLE IN THE
 BREAKFAST ROOM. 210.52(B).
  
 8} PLEASE SEE BATH GFI IN THE CABANA IS
 INDICATED ON THE POOL PUMP CIRCUIT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2006-03-30 Cont ID  
Sent By alange Date 2006-03-30 Time 10:11 Rev Time 0.00
Received By alange Date 2006-03-30 Time 10:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2006-02-22 Cont ID  
Sent By jleech Date 2006-02-22 Time 08:05 Rev Time 1.00
Received By jleech Date 2006-02-22 Time 08:05 Sent To B
Notes
2006-02-22 00:00:00DENIED;
 1.GAS RISER DIAGRAM DOES NOT SHOW POOL
 HEATER OR GENERATOR.
 2.NO SPECIFICATIONS WERE FOUND FOR
 INSTANT HOT. I COULD NOT FIND TOTLE
 BTU'S FOR STOVE AND DRIER FROM SPEC.
 SHEETS.
 3.BTU'S ON RISER DIAGRAM DO NOT MATCH
 BTU'S ON SPEC. SHEETS. (MARKED IN RED ON
 ONE SET OF PLANS)
 4.PIPE SIZES ARE NOT CORRECT, SEE
 FBC-2004 FUEL GAS TABLE 402.4(2).
 5.OTHER PIPING MATERIAL WILL BE USED BY
 THE GAS CONTRACTOR @ PE FOR UNDER
 GROUND, CSST IN ATTIC. EACH PIPING
 MATERIAL HAS IT'S OWN TABLE.
 IF YOU DELETE THE GAS RISER FROM YOUR
 PLAN THE GAS CONTRACTOR HIRED COULD
 PROVIDE THE REQUIRED DRAWINGS WITH THE
 GAS PERMIT APPLICATION AT A LATER TIME.
 GAS PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2005-11-19 Cont ID  
Sent By jleech Date 2005-11-19 Time 14:39 Rev Time 0.50
Received By jleech Date 2005-11-19 Time 14:39 Sent To B
Notes
2005-11-19 00:00:00GAS PLAN DENIED.
 1.GAS PIPE SIZING IS NOT CORRECT
 FBC-2004 FUEL GAS TABLE 402.4(2)
 2.GALV PIPE UNDER GROUND MUST BE FACTORY
 RAPPED AND CAN NOT HAVE ANY EXPOSED
 AREAS. SEC. 404.8.
 3.PROVIDE MANUFATURE'S CUT SHEETS
 SHOWING BTU'S FOR EACH APPLIANCE.
 GAS PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-08-14 Cont ID  
Sent By adarroug Date 2007-08-14 Time 16:19 Rev Time 0.00
Received By adarroug Date 2007-08-14 Time 16:19 Sent To M
Notes
2007-08-14 16:25:25TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-08-14 Cont ID  
Sent By adarroug Date 2007-08-14 Time 16:15 Rev Time 0.00
Received By adarroug Date 2007-08-14 Time 16:15 Sent To  
Notes
2007-08-14 16:15:59TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-08-02 Cont ID  
Sent By adarroug Date 2007-08-02 Time 10:34 Rev Time 0.00
Received By adarroug Date 2007-08-02 Time 10:34 Sent To M
Notes
2007-08-02 10:35:14TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-07-26 Cont ID  
Sent By adarroug Date 2007-07-26 Time 09:43 Rev Time 0.00
Received By adarroug Date 2007-07-26 Time 09:43 Sent To E
Notes
2007-07-26 09:43:29TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-07-11 Cont ID  
Sent By adarroug Date 2007-07-11 Time 15:18 Rev Time 0.00
Received By adarroug Date 2007-07-11 Time 15:18 Sent To M
Notes
2007-07-11 15:19:17TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-02-01 Cont ID  
Sent By adarroug Date 2007-02-01 Time 11:39 Rev Time 0.00
Received By adarroug Date 2007-02-01 Time 11:39 Sent To B
Notes
2007-02-01 11:40:12TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-17 Cont ID  
Sent By adarroug Date 2006-03-17 Time 14:35 Rev Time 0.00
Received By adarroug Date 2006-03-17 Time 14:35 Sent To E
Notes
2006-03-17 00:00:00TO "BTROBAUG" DESK/RESUB--APPL. STATES
 GAS CONTRACTOR TO REAPPLY LATER.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-19 Cont ID  
Sent By adarroug Date 2006-02-19 Time 10:47 Rev Time 0.00
Received By adarroug Date 2006-02-19 Time 10:47 Sent To E
Notes
2006-02-19 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-13 Cont ID  
Sent By adarroug Date 2006-02-13 Time 18:02 Rev Time 0.00
Received By adarroug Date 2006-02-13 Time 18:02 Sent To Z
Notes
2006-02-13 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-11-09 Cont ID  
Sent By adarroug Date 2005-11-09 Time 10:34 Rev Time 0.00
Received By adarroug Date 2005-11-09 Time 10:34 Sent To E
Notes
2005-11-09 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-23 Cont ID  
Sent By alange Date 2005-12-23 Time 09:54 Rev Time 0.00
Received By alange Date 2005-10-19 Time 09:39 Sent To  
Notes
2005-10-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-08-15 Cont ID  
Sent By tgordon Date 2007-08-15 Time 12:13 Rev Time 0.30
Received By tgordon Date 2007-08-15 Time 12:13 Sent To  
Notes
2007-08-15 12:14:28REVISION TO MECH. PLANS PAGE M-1 AND M-2.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-08-02 Cont ID  
Sent By tgordon Date 2007-08-02 Time 15:23 Rev Time 0.30
Received By tgordon Date 2007-08-02 Time 15:23 Sent To  
Notes
2007-08-02 15:24:25REVISION TO MECHANICAL PLANS PAGE M-1, M-2, AND ENERGY
 CALCULATIONS.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-07-13 Cont ID  
Sent By tgordon Date 2007-07-13 Time 09:35 Rev Time 0.40
Received By tgordon Date 2007-07-13 Time 09:35 Sent To  
Notes
2007-07-13 09:47:27MECHANICAL REVISION
 *** DENIED ***
 1) EDWARD J. KRANZ (ENGINEER) SEALED THE MECHANICAL
 PLANS ON FILE SO HE NEEDS TO SEAL THE REVISION.
  
 2) ENERGY CALCULATIONS ON FILE ARE TAKING CREDIT FOR A
 HEAT RECOVERY UNIT THE REVISED MECHANICAL PLANS HAVE
 THE HEAT RECOVERY UNIT REMOVED, PLEASE CORRECT.
  
 3) SHOW HOW THE RETURN AIR IS GETTING BACK TO AHU 1 AND
 3 , IF LOUVER DOOR PLEASE SHOW ON MECHANICAL PLANS.
  
 4) THE 8X4 SUPPLY AIR GRILL FOR BATHROOM #3 IS LOCATED
 IN BEDROOM #5 NOT IN THE BATHROOM, PLEASE CORRECT.
  
 5) PERMIT #07050292 OR 06110063 ARE FOR THE SAME JOB
 ONE WILL NEED TO BE VOIDED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-03-24 Cont ID  
Sent By tgordon Date 2006-03-23 Time 09:23 Rev Time 1.30
Received By tgordon Date 2006-03-24 Time 14:46 Sent To B
Notes
2006-03-23 00:00:00 

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-02-21 Cont ID  
Sent By tgordon Date 2006-02-21 Time 11:58 Rev Time 1.20
Received By tgordon Date 2006-02-21 Time 11:58 Sent To P
Notes
2006-02-21 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004) PER FBC 13-600.3.A .
  
 2) AHU #1 RETURN AIR GRILL 30X14 IS TO
 SMALL FOR A 5 TON A/C UNIT. NOTE,
 KITCHEN DOOR WILL BLOCKRETURN AIR
 GRILL IF LEFT OPEN.
  
 3) CLOTHES DRYER NEEDS TO TERMINATE AT
 LEAST 4 FEET FROM A/C CONDENSER UNIT.
  
 4) COMBUSTION AIR INLETS TO LAUNDRY ROOM
 CAN NOT HAVE GENERATOR EXHAUST, CLOTHES
 DRYER VENT, A/C CONDENSER FAN WITHIN 10
 FEET, PER 2004 FBC/M 401.5.1 .
  
 5) GENERATOR EXHUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJECENT BUILDING
 OPENS. PER 2004 FBC/M 401.5.1 .
  
 6) DUCT (FLEX) TO BEDROOM #4 IS NOT
 SIZED.
  
 7) RETURN AIR GRILL 24X24 IS TO SMALL
 FOR A 4 TON A/C UNIT.
  
 8) NOTE, RETURN AIR TRANSFER DUCTS.
 BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 8) PLEASE REMOVE ALL OLD PLANS FROM PLAN
 SET.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-11-14 Cont ID  
Sent By tgordon Date 2005-11-14 Time 14:48 Rev Time 0.35
Received By tgordon Date 2005-11-14 Time 14:48 Sent To P
Notes
2005-11-14 00:00:00MECHANICAL PERMIT NOT BEING APPLIED FOR
 AT THIS TIME. PLEASE NOTE THE FOLLOWING
 REGUARDING YOUR MECHANICAL PLANS.
 AHU #1 ( 1ST. FLOOR )
 1) NEED TO SHOW RETURN AIR DUCT SIZE.
 2) TRANSFER DUCT IN STUDY MUST BE 1 1/2
 TIMES LARGER THAN SUPPLY AIR DUCT (8"
 SUPPLY AIR DUCT REQUIRES A 10" RETURN
 AIR TRANSFER DUCT). PER 2004 FBC/R
 M1602.4 .
 3)RAG IN MASTER VESTIBULE IS TO SMALL,
 TRANSFER GRILLS MUST BE 50 SQ. IN. PER
 100 CFM'S (300 SQ. IN.). PER FBC/R
 M1602.4 .
 4) COMBUSTION AIR LOUVERS, PLEASE SEE
 2004 FBC/R M1701.5 .
 5) WILL NEED DETAILED MANUFACTURE'S
 SPECIFICATION'S ON GAS FIREPLACE AND
 COMBUSTION AIR CALCULATIONS.
 6) WILL NEED DETAILED MANUFACTURE'S
 SPECIFICATION'S ON GAS BBQ UNDER COVERED
 LOGGIA, OR AN APPROVED HOOD.
 7) PLANS CALL FOR 109,400 TOTAL BTU'S
 ENERGY CALCULATIONS CALL FOR 68,000
 BTU,S THE TO MUST COINCIDE.
 8) PLEASE ADDRESS GENERATOR EXHUST.
 9) WILL NEED DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS ON GENERATOR.
 AHU #2 (2ND. FLOOR)
 10) RAG IN BEDROOM #5 NOT SIZED.
 11) TRANSFER DUCT IN BEDROOM #3 & 4 NEED
 TO BE 10" .
 12) TRANSFER DUCT IN BEDROOM # 2 NOT
 SIZED.
 13) RETURN AIR DUCT FROM 24X24 RAG TO
 AHU #2 NOT SIZED.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-11-19 Cont ID  
Sent By btrobaug Date 2007-08-01 Time 11:22 Rev Time 0.50
Received By jleech Date 2005-11-19 Time 14:38 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2008-04-16 Cont ID  
Sent By choops Date 2008-04-16 Time 14:59 Rev Time 0.00
Received By choops Date 2008-04-16 Time 14:59 Sent To PC
Notes
2008-04-16 14:59:56***APPROVED - LANDSCAPE PLAN SUBMITTAL, 4/16/08***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-02-17 Cont ID  
Sent By mmclean Date 2006-02-17 Time 18:36 Rev Time 0.00
Received By mmclean Date 2006-02-17 Time 18:36 Sent To I
Notes
2006-02-17 00:00:00NOTE: THE EQUIPMENT CAN ONLY ENCROACH
 4FT INTO A SETBACK (A/C ETC).
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/SPA.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-11-07 Cont ID  
Sent By mmclean Date 2005-11-07 Time 14:17 Rev Time 0.00
Received By mmclean Date 2005-11-07 Time 14:17 Sent To I
Notes
2005-11-07 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK OF PROPERTY.
 2. MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 FRONT PROPERTY IS 1561.5SQ FT AND CAN
 ONLY HAVE 561.5SQ FT OF CONCRETE WITHIN
 THE FIRST 25FT FRONT SETBACK.
  
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy