Plan Review Stops For Permit 05100903 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-01 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-01 |
Time |
17:04 |
Sent To |
|
|
Notes |
2007-02-01 17:04:54 | GARAGE DOOR PRODUCT APPROVALS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-17 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-08-17 |
Time |
09:19 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | WINDOWS ADDED, REVISED S PAGES |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-01 |
Time |
15:45 |
Rev Time |
0.75 |
Received By |
alange |
Date |
2006-08-01 |
Time |
15:45 |
Sent To |
|
|
Notes |
2006-08-01 00:00:00 | DENIED | | | | 1.ALL OF THE PRODUCT APPROVALS | | SUBMITTED SHALL HAVE THE FOLLOWING STATE | | PRODUCT APPROVAL INFORMATION ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 2.REVISE PERMIT VALUATION TO INCLUDE | | ALL NEW WINDOWS AND DOORS ADDED. | | | | 3.SHOW SIZE OF BEDROOMM WINDOWS SO | | THAT EMERGENCY ESCAPE RESCUE OPENING | | SIZES CAN BE CHECKED.R-310 | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-10 |
Time |
08:06 |
Rev Time |
0.75 |
Received By |
alange |
Date |
2006-07-10 |
Time |
08:06 |
Sent To |
|
|
Notes |
2006-07-10 00:00:00 | TRUSS DRAWINGS REVIEWED AND APPROVED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-02-28 |
Time |
13:16 |
Rev Time |
1.75 |
Received By |
alange |
Date |
2006-02-28 |
Time |
11:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-15 |
Time |
07:15 |
Rev Time |
2.25 |
Received By |
alange |
Date |
2005-12-15 |
Time |
07:15 |
Sent To |
|
|
Notes |
2005-12-15 00:00:00 | DENIED | | | | 1.SUBMIT TWO ORIGONAL SIGN AND SEALED | | SURVEYS.FS 472.025 | | | | 2.SUBMIT TWO COMPLETE SETS OF PRODUCT | | APPROVALS. | | | | ANY QUESTIONS CALL ME. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-04 |
Time |
17:55 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-10-03 |
Time |
07:56 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-03-22 |
Time |
07:38 |
Rev Time |
1.33 |
Received By |
btrobaug |
Date |
2006-03-22 |
Time |
06:20 |
Sent To |
PC |
|
Notes |
2006-03-22 00:00:00 | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | PREVIOUS COMMENT: | | | | 1} "IF THE SUBPANEL SHOWN ON THE RISER | | IS FOR A SEPARATE STRUCTURE INDICATE | | COMPLIANCE WITH 250.32 AND 225.32." | | CLEARLY THERE IS A GUEST COTTAGE ON THE | | PROPERTY. THIS BUILDING MUST HAVE A | | DISCONNECTING MEANS AND A GROUNDING | | SYSTEM INSTALLED PER THE ABOVE NOTED | | ARTICLES. PLEASE INDICATE SAME ON THE | | PLAN. SHOW THE LOCATIION OF ALL SERVICE | | EQUIPMENT , INCLUDING THE PANELS AND | | SUBPANELS, ON THE PLAN. DESIGNATE THEM | | FOR CLARITY. | | | | 2} THE GROUNDING ELECTRODE SYSTEM MUST | | ALSO BE BONDED TO BUILDING STEEL SINCE | | IT IS AVAILABLE ON THE PREMISES PER | | 250.52(A)(3). PLEASE INDICATE COMPLIANCE | | ON THE RISER. | | | | | | REGARDING THE ARCHITECT OF RECORD. THE | | TITLE BLOCK MUST COMPLY WITH | | 61G1-16.004, FAC. A COPY OF THE | | CERTIFICATION IS NOTED, BUT THE FAC | | STTES THAT THE AA NUMBER MUST APPEAR IN | | THE TITLE BLOCK. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-22 |
Time |
13:20 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-02-22 |
Time |
12:29 |
Sent To |
M |
|
Notes |
2006-02-22 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PROVIDE THE AIC RATING OF THE SERVICE | | EQUIPMENT PER 110.9. | | | | 2} PLEASE INDICATE THE OCP AND CONDUCTOR | | SIZES ON THE PANEL SCHEDULES SO THAT | | BRANCH CIRCUIT COMPLIANCE MAY BE | | REVIEWED. | | | | 3} IF THE SUBPANEL SHOWN ON THE RISER IS | | FOR A SEPARATE STRUCTURE INDICATE | | COMPLIANCE WITH 250.32 AND 225.32. | | | | 4} A RECEPTACLE IS REQUIRED IN THE | | FAMILY ROOM PER 210.52(A)(2). SEE | | REVIEWED PLAN FOR LOCATION. | | | | 5} THERE ARE TWO PANEL #1'S ON THE | | RISER. | | | | REGARDING THE ARCHITECT OF RECORD. THE | | TITLE BLOCK MUST COMPLY WITH | | 61G1-16.004, FAC. WHAT IS "DESIGN | | METHODS" ? | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-06 |
Time |
14:41 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-12-06 |
Time |
07:43 |
Sent To |
M |
|
Notes |
2005-12-06 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE GROUNDING ELECTRODE CONDUCTOR | | MUST COMPLY WITH 250.66, 1/0 MINIMUM FOR | | 400MCM. | | | | 2} A RECEPTACLE PER 210.52(E) IS | | REQUIRED IN THE FRONT AND REAR OUTSIDE, | | AND PER 210.63 FOR THE CONDENSERS, BUT | | ONE IN THE REAR (WITHIN 25'),WILL | | SUFFICE. | | | | 3} THE FANS IN THE LIVING ROOM MUST HAVE | | A LIGHT KIT OR A RECEPTACLE SWITCHED. | | 210.70(A)(1). | | | | 4} THE TITLE BLOCK MUST CONTAIN THE | | CORPORATE NUMBER OF THE FIRM PER | | 61G1-16.003 FAC. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-28 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-02-28 |
Time |
07:27 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2005-12-10 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-12-10 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-12-10 |
Time |
13:30 |
Sent To |
P |
|
Notes |
2005-12-10 00:00:00 | PAUL SCHMITZ | | FBC 2004 FUEL GAS CODE, PLAN REVIEW | | DENIED | | 1. SHT P-1 GAS RISER | | SHOW LOCATION OF GAS WATER HEATER. | | 2.KITCHEN STOVE,PROVIDE MANFACTURE | | INFORMATION FOR RESIDENTAL USE. | | 3. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | 4. TYPE OF GAS, (LP OR NATURAL) | | 5. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2001 | | FUEL GAS CODE. | | 5. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES (A)(3). | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-21 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-21 |
Time |
08:20 |
Sent To |
E |
|
Notes |
2006-09-21 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-21 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-21 |
Time |
08:17 |
Sent To |
M |
|
Notes |
2006-09-21 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-08-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-12 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-12 |
Time |
14:59 |
Sent To |
B |
|
Notes |
2006-08-12 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-31 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-31 |
Time |
11:40 |
Sent To |
B |
|
Notes |
2006-07-31 00:00:00 | TO "ALANGE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-06 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-06 |
Time |
11:55 |
Sent To |
B |
|
Notes |
2006-07-06 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-03-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-17 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-17 |
Time |
14:30 |
Sent To |
E |
|
Notes |
2006-03-17 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-22 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-22 |
Time |
11:18 |
Sent To |
E |
|
Notes |
2006-02-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-13 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-13 |
Time |
18:07 |
Sent To |
Z |
|
Notes |
2006-02-13 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-05 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-05 |
Time |
11:02 |
Sent To |
E |
|
Notes |
2005-12-05 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-11-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-10 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-10 |
Time |
11:17 |
Sent To |
B |
|
Notes |
2005-11-10 00:00:00 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-15 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2005-10-19 |
Time |
09:38 |
Sent To |
|
|
Notes |
2005-10-19 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-28 |
Time |
15:39 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-09-28 |
Time |
15:39 |
Sent To |
|
|
Notes |
2006-09-28 00:00:00 | *** PROVISO *** | | 1) DUCTS IN THE GARAGE AND DUCTS | | PENETRATING THE WALLS OR CEILINGS | | SEPARATING THE DWELLING FROM THE GARAGE | | SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 | | GAGE SHEET STEEL OR OTHER APPROVED | | MATERIAL AND SHALL HAVE NO OPENINGS INTO | | THE GARAGE. PER 2004 FBC/R 309.1.1 . | | 2) PROVIDE COMBUSTION AIR FOR GAS WATER | | HEATER, PER 2004 FBC/R M1701.1 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-02-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-02-22 |
Time |
15:43 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-02-22 |
Time |
15:43 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-12-07 |
Time |
09:39 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-12-07 |
Time |
09:39 |
Sent To |
P |
|
Notes |
2005-12-07 00:00:00 | *** DENIED *** | | 1) NEED ENERGY CALCULATIONS ON THE | | ENTIRE HOUSE NOT JUST THE ADDITION ONLY. | | 2) PLEASE CHECK THE SIZE OF THE RETURN | | AIR GRILL ON THE FIRST FLOOR, TWO 18X12 | | GRILLS APPEAR TO BE A 148 SQUARE INCHES | | TO SMALL. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-02-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-02-28 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-02-28 |
Time |
07:26 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-10 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2005-12-10 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2005-12-10 |
Time |
13:51 |
Sent To |
B |
|
Notes |
2005-12-10 00:00:00 | PAUL SCHMITZ | | FBC 2001 PLUMBING CODEPLAN REVIEW | | DENIED | | 1.TAB 403.1 MINIMUM PLUMBING FIXTURES. | | ONE AUTOMATIC CLOTHES WASHER CONNECTONN | | REQUIRED. | | 2.SHT E-1 SERVICE CALCULATION, SHOWS AN | | ELECTRRIC WATER. PLEASE CLARIFY IF THERE | | ARE TWO WATER HEATERS, ONE ELECTRIC & | | ONE GAS WATER HEATER, AND THEY LOCATION | | OF EACH ONE | | END OF COMMENTS, QUESTIONS 561-805-6692 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-02-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-02-21 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-02-21 |
Time |
10:18 |
Sent To |
I |
|
Notes |
2006-02-21 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | FENCE/WALL/COLUMNS/GATE WITH EASMENT | | APPROVAL FROM THE CITY OF WEST PALM | | BEACH UTILITY DEPT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-11-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-11-01 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-11-01 |
Time |
14:05 |
Sent To |
I |
|
Notes |
2005-11-01 00:00:00 | DENIED, | | 1. NEED TO PROVIDE TWO COPY OF COMPLETE | | SITEPLANS, SHOWING THE ADDRESS OF THE | | PROPERTY | | 2. MUST PROVIDE THE SETBACKS OF THE | | EXISTING AND NEW STRUCTURE (SIDE/FRONT | | REAR SETBACK) | | 3. MUST PROVIDE THE DISTANCE OF THE | | PROPOSED ADDITION FROM THE EXISTING ONE | | STORY GUEST HOUSE. | | | | **************************************** | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | CMU RETAINING WALL WITH EASEMENT | | APPROVAL FROM THE CITY OF WEST PALM | | BEACH UTILITY DEPT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|