Plan Review Stops For Permit 05100471 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2005-10-13 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2005-10-13 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-10-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-10-13 |
Time |
08:59 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2005-10-13 |
Time |
08:59 |
Sent To |
|
|
Notes |
2005-10-13 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- DADE COUNTY NOA SUBMITTED FOR FLAT | | ROOF IS FOR A ROOF SYSTEM OVER STEEL | | DECKS. THIS HOUSE DOESN'T HAVEA STEEL | | DECK. NEED PRODUCT APPROVAL FOR FLAT | | ROOF SYSTEM OVER WOOD DECKS. | | | | 2- PROVIDE COMPLETE DADE COUNTY NOA | | REPORT FOR FLAT ROOF SYSTEM. FROM ALL | | THE APPROVED ASSEMBLIES SHOWN ON THE | | DADE COUNTY NOA SUBMITT ONLY THE SYSTEM | | THAT IS GOING TO BE INSTALLED IN THIS | | HOUSE. | | **NOTE: MAKE SURE THAT SELECTED SYSTEM | | IS NO LIMITED BY GENERAL LIMITATION #9, | | WHICH DOESN'T ALLOW FOR ADDITIONAL NAIL | | ENHANCING TO INCREASE THE UPLIFT DESIGN | | PRESSURES. SEE GENERAL LIMITATION AT THE | | END OF THE NOA REPORT. | | | | 3- SPECIFY ROOF PITCH, MEAN ROOF HEIGHT, | | SQUARE FOOTAGE FOR FLAT AND PITCH ROOF | | AND ALL THE INFORMATION REQUIRED BY THE | | CITY POLICY FOR ROOFING/REROOFING | | PERMITS. SEE ATTACHED COPY. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712. | | |
|
|
|