Plan Review Details - Permit 05100446
Plan Review Stops For Permit 05100446 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-11-29 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-11-29 |
Time |
11:21 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2005-11-29 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-02-09 |
Time |
15:23 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2006-02-09 |
Time |
13:47 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-11-21 |
Time |
16:44 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-11-21 |
Time |
15:51 |
Sent To |
M |
|
Notes |
2005-11-21 00:00:00 | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE GROUND WIRE SHOWN FROM THE METER | | TO THE ATS' PARALLELS THE NEUTRAL AND | | CANNOT BE INSTALLED. ALSO NOTE THAT THE | | ATS' BECOME THE FIRST MEANS OF | | DISCONNECT AND THE NEUTRAL MUST BE | | ISOLATED AT THAT POINT. | | | | 2} INDICATE THE TYPE OF FUEL, NATURAL OR | | LP GAS. THIS CAN BE HIGHLIGHTED ON THE | | SPEC SHEET. | | | | 3} PLEASE SHOW THE LOCATION OF ALL THE | | SERVICE EQUIPMENT ON THE SITE PLAN. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-02-06 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-02-06 |
Time |
16:22 |
Sent To |
E |
|
Notes |
2006-02-06 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-11-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-10 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-10 |
Time |
11:21 |
Sent To |
E |
|
Notes |
2005-11-10 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-10-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-13 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-13 |
Time |
16:20 |
Sent To |
Z |
|
Notes |
2005-10-13 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2005-11-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-11-22 |
Time |
09:32 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2005-11-22 |
Time |
09:32 |
Sent To |
B |
|
Notes |
2005-11-22 00:00:00 | *** PROVISO *** | | 1) GENERATOR EXHUST MUST BE TEN FEET | | AWAY FROM ANY BUILDING OPENINGS | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | TEN FEET AWAY FROM ADJECENT BUILDING | | OPENS. | | 2) DETAILED MANUFACTURE'S | | SPECIFICATION'S AND INSTALLATION | | INSTRUCTIONS MUST BE ON JOB SITE. | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | TOM GORDON 805-6729 OR PATTY KRAUSS | | 805-6719. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-11-01 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-11-01 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-11-01 |
Time |
12:07 |
Sent To |
I |
|
Notes |
2005-11-01 00:00:00 | GENERATOR CAN ONLY ENCROACH 4FT INTO | | SETBACK. |
|
|
|