Plan Review Stops For Permit 05100266 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-12-27 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2005-12-27 |
Time |
11:17 |
Rev Time |
0.50 |
Received By |
amorse |
Date |
2005-12-27 |
Time |
11:17 |
Sent To |
PC |
|
Notes |
2005-12-30 00:00:00 | | | | | ?PROVISO? | | | | POOL BARRIER REQUIREMENTS PER 424.2.17 & | | R4101.17 | | SHALL BE IN PLACE AT POOL FINAL | | INSPECTION PER | | R4101.19 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-01-17 |
Time |
06:12 |
Rev Time |
0.30 |
Received By |
jleahy |
Date |
2006-01-17 |
Time |
06:12 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2005-10-11 |
Time |
07:16 |
Rev Time |
0.30 |
Received By |
jleahy |
Date |
2005-10-11 |
Time |
07:16 |
Sent To |
P |
|
Notes |
2005-10-11 00:00:00 | NEED LOAD CALCULATION FOR SERVICE. | | | | SHOW BRANCH CIRCUIT SIZES. | | | | NEED PANEL SCHEDULE. | | | | | | JAKE LEAHY644-7291 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-06 |
Time |
10:06 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2005-12-06 |
Time |
10:06 |
Sent To |
P |
|
Notes |
2005-12-06 00:00:00 | GAS CONTRACTOR TO SUBMIT APPLICATION | | WITH PLAN FOR POOL HEATER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-13 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-13 |
Time |
11:35 |
Sent To |
E |
|
Notes |
2006-01-13 00:00:00 | TO "JLEAHY" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-30 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-30 |
Time |
10:51 |
Sent To |
Z |
|
Notes |
2005-12-30 00:00:00 | TO "Z" BOX/RESUB-NEW SHEETS! |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-09 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-09 |
Time |
14:58 |
Sent To |
P |
|
Notes |
2005-11-09 00:00:00 | TO "P" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-27 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2005-10-14 |
Time |
15:30 |
Sent To |
Z |
|
Notes |
2005-10-14 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-01-20 |
Time |
15:26 |
Rev Time |
2.00 |
Received By |
mperson |
Date |
2006-01-20 |
Time |
15:26 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-12-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2005-12-13 |
Time |
09:44 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-12-06 |
Time |
10:09 |
Sent To |
B |
|
Notes |
2005-12-06 00:00:00 | DENIED; | | 1) COMPLY WITH FBC-2004 SEC 424.2 | | PRIVATE SWIMMING POOLS. | | 2) FBC-2004 SEC 424.2.6.1 ENGINEERING | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | ANSI/NSPI-5. (ADD TO NOTES) | | 3) FBC-2004 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 4)FBC-2004 424.2.9 WATER SUPPLY, LOCAL | | 0RD. #2853-95,BACKFLOW REQUIRED ON WATER | | SERVICE. (ADD TO NOTES) | | 5.FBC-2004 424.2.13.2 JOINTS AND | | CONNECTIONS, PLUMBING SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | NOTES) | | 6.FBC 2004 424. 2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. (ADD TO NOTES) | | 7) FBC-2004424.2.6.6.2 SHOW COMPLIANCE | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | NUMBER AND MANUF INFO FOR VAC LOCK. | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | 8) FBC-2004424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. PLEASE SHOW LOCATION ON | | PAGE 1 | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2006-01-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-01-12 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-01-12 |
Time |
11:30 |
Sent To |
I |
|
Notes |
2006-01-12 00:00:00 | ZONING ALREADY APPROVED 10/31/05, | | NOTHING CHANGED WITH SETBACKS.SEE PLAN | | WITH APPROVAL. | | | | MICHELLE MCLEAN | | ZONING TECHICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-10-31 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-10-31 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-10-31 |
Time |
15:01 |
Sent To |
I |
|
Notes |
|
|