Plan Review Stops For Permit 05100075 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2005-12-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-25 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-08-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-08-11 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-08-11 |
Time |
10:02 |
Sent To |
|
|
Notes |
2006-08-11 00:00:00 | REVISED A0, A1 DATED 7/17/06 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-06-06 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-06-05 |
Time |
12:51 |
Sent To |
Z |
|
Notes |
2006-06-06 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)PROVIDE PARKING INFORMATION (TOTAL | | NUMBER OF SPACES, NUMBER OF ACCESSIBLE | | SPACES.) | | | | 2.)ACCESSIBLE PARKING REQUIRED IN THE | | REAR OF THE BUILDING.SEE | | FBC11-4.1.6(1)(B), FBC11-4.1.2(5)(A) | | REFERS TO "EACH SUCH PARKING AREA". | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-03-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-03-27 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-03-27 |
Time |
09:32 |
Sent To |
|
|
Notes |
2006-03-27 00:00:00 | FIRE SPRINKLERS SEPARATE PERMIT | | #05100075 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-02-14 |
Time |
09:15 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2006-02-13 |
Time |
15:16 |
Sent To |
|
|
Notes |
2006-02-14 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | FROM PREVIOUS LIST | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2.)SEE PREVIOUS LIST, ITEMS 1 AND 2. | | THEY WERE TO BE CORRECTED ON THE | | UNNUMBERED SHEET WITH BUILDING DATA. | | THIS SHEET WAS NOT REVISED AND | | RESUBMITTED.THIS SHEET PROVIDES | | INFORMATION REQUIRED TO SHOW CODE | | COMPLIANCE.SEE THE VOIDED SET. | | | | PLEASE REVISE OCCUPANT LOAD TO 97. | | | | 3.)SEE PREVIOUS LIST, ITEM #3.REVISE | | APPLICATION TO REFLECT CORRECT SCOPE OF | | WORK, INCLUDING EXTERIOR STAIR AND | | WHEELCHAIR LIFT. | | | | THIRD REQUEST; PLEASE COMPLY BEFORE | | PERMIT ISSUANCE. | | | | 4.)ADDRESSED. | | | | 5.)ADDRESSED. | | | | 5.)ADDRESSED. | | | | 7.)SEE PREVIOUS LIST, ITEM #9.THE | | STAIR HANDRAIL EXTENSIONS ARE TO COMPLY | | WITH FBC11-4.8.5(6), FIGURE 19.AS | | DESIGNED THEY POSE A HAZARD. THEY ARE TO | | BE ROUNDED OR RETURN TO THE FLOOR.NOT | | ADDRESSED. | | | | THIS WAS ADDRESSED BUT A PREVIOUS | | REQUEST FOR THE DIMENSION OF THE RAIL | | LENGTH AT THE TOP OF THE STAIR WAS NOT | | ADDRESSED.PLEASE PROVIDE THAT | | DIMENSION. | | | | 8.)ADDRESSED. | | | | 9.)SEE PREVIOUS LIST, ITEM 12. | | PROVIDE EITHER AN APPROVED ASSEMBLY OR | | CALCULATED FIRE RESISTANCE FOR THE 1 | | HOUR WALL, FBC7. | | | | THE UL ASSEMBLY PROVIDED IS NOT VALID. | | NOTE THAT YOU HAVE SPECIFIED D419; THIS | | SHOULD BE A U ASSEMBLY. | | | | 10.)PROVIDE A FIRE SPRINKLER PLAN | | FBC*106.3.5.1.1(5). | | | | THIS IS REQUIRED BY FLORIDA STATUE PRIOR | | TO PERMIT ISSUANCE WHEN SPRINKLERS ARE | | REQUIRED FOR CODE COMPLIANCE.PROVIDE A | | SPRINKLER LAYOUT PLAN AS REQUESTED.IT | | IS UNDERSTOOD THAT SPRINKLER DRAWINGS ON | | A SEPARATE PERMIT WILL BE PROVIDED, BUT | | A SPRINKLER PLAN IS REQUIRED AT THIS | | TIME FOR THE RENOVATION PERMIT. | | | | 10.)SEE ATTACHED FS553.80(2)(B).A 4X | | PLAN REVIEW FEE WILL BE CHARGED IF THE | | ABOVE ITEMS ARE NOT ADDRESSED IN THE | | THIRD REVIEW. | | | | A 4X FEE WAS CHARGED BY ELECTRIC.THERE | | ARE ALSO BUILDING COMMENTS WHICH WERE | | NOT ADDRESSED 3X.PLEASE NOTE THAT THE | | FEE WILL BE CHARGED AGAIN IF THE | | COMMENTS ARE NOT ADDRESSED A 4TH TIME. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-12-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-25 |
Time |
16:07 |
Rev Time |
2.00 |
Received By |
shill |
Date |
2005-12-25 |
Time |
16:00 |
Sent To |
|
|
Notes |
2005-12-25 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2.)SEE PREVIOUS LIST, ITEMS 1 AND 2. | | THEY WERE TO BE CORRECTED ON THE | | UNNUMBERED SHEET WITH BUILDING DATA. | | THIS SHEET WAS NOT REVISED AND | | RESUBMITTED.THIS SHEET PROVIDES | | INFORMATION REQUIRED TO SHOW CODE | | COMPLIANCE.SEE THE VOIDED SET. | | | | 3.)SEE PREVIOUS LIST, ITEM #3.REVISE | | APPLICATION TO REFLECT CORRECT SCOPE OF | | WORK, INCLUDING EXTERIOR STAIR AND | | WHEELCHAIR LIFT. | | | | 4.)REVISIONS WERE MADE TO SHEET A1 AND | | NOT CLOUDED.OTHER SHEETS MAY BE | | AFFECTED AS WELL.WITHOUT A RESPONSE | | LETTER (OPTIONAL BUT HELPFUL) AND | | CLOUDED CHANGES (REQUIRED) IT MAKES IT | | DIFFICULT TO LOCATE THE ADDRESSED ITEMS. | | PLEASE CLOUD ALL CHANGES. | | | | 5.)SEE PREVIOUS LIST, ITEM 4, NOT | | ADDRESSED.THE WHEELCHAIR LIFT IS TO | | COMPLY WITH ASME A17.1, FBC3001.2. | | | | 5.)SEE PREVIOUS LIST, ITEM 5, NOT | | ADDRESSED.SHOW COMPLIANCE WITH | | FBC11-4.11.2, FBC11-4.2.4 FOR THE LIFT. | | INDICATE THAT THE SURFACE IS LEVEL.OR, | | PROVIDE OTHER INFORMATION AND SHOW | | COMPLIANCE WITH FBC CHAPTER 11.NOT | | ADDRESSED. | | | | 7.)SEE PREVIOUS LIST, ITEM #9.THE | | STAIR HANDRAIL EXTENSIONS ARE TO COMPLY | | WITH FBC11-4.8.5(6), FIGURE 19.AS | | DESIGNED THEY POSE A HAZARD. THEY ARE TO | | BE ROUNDED OR RETURN TO THE FLOOR.NOT | | ADDRESSED. | | | | 8.)SEE PREVIOUS LIST, ITEM 11.SHOW | | LANDING AND DOOR DIMENSIONS, FBC1009.4, | | EXCEPTION 2.NOT ADDRESSED. | | | | 9.)SEE PREVIOUS LIST, ITEM 12. | | PROVIDE EITHER AN APPROVED ASSEMBLY OR | | CALCULATED FIRE RESISTANCE FOR THE 1 | | HOUR WALL, FBC7. | | | | 10.)SEE ATTACHED FS553.80(2)(B).A 4X | | PLAN REVIEW FEE WILL BE CHARGED IF THE | | ABOVE ITEMS ARE NOT ADDRESSED IN THE | | THIRD REVIEW. | | | | | | 10.)PROVIDE A FIRE SPRINKLER PLAN | | FBC*106.3.5.1.1(5). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-11-21 |
Time |
18:02 |
Rev Time |
1.00 |
Received By |
shill |
Date |
2005-11-21 |
Time |
17:58 |
Sent To |
|
|
Notes |
2005-11-21 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | TO THE FBC2004 | | | | 1.)GOVERNING CODE IS FBC2004 EFFECTIVE | | 10/1/2005. | | | | 2.)BUILDING DATA (UNNUMBERED SHEET) | | PROVIDES INCORRECT TABLE FOR INTERIOR | | FINISH CLASSIFICATION, FBC TABLE 803.5. | | | | 3.)THE APPLICATION STATES THAT THIS IS | | A TENANT IMPROVEMENT.PLANS SHOW A NEW | | EXTERIOR STAIR AND WHEELCHAIR LIFT. | | REVISE THE PERMIT APPLICATION. | | | | 4.)THE WHEELCHAIR LIFT IS TO COMPLY | | WITH ASME A17.1, FBC3001.2. | | | | 5.)SHOW COMPLIANCE WITH FBC11-4.11.2, | | FBC11-4.2.4 FOR THE LIFT.INDICATE THAT | | THE SURFACE IS LEVEL. | | | | 6.)SHOW COMPLIANCE WITH ALL | | REQUIREMENTS OF FBC11-4.27. | | | | 7.)PROVIDE A DETAIL FOR THE BREAKROOM | | SINK, FBC11-24.PLEASE NOTE THE | | REQUIREMENT FOR KNEE CLEARANCE, | | FBC11-24.3. | | | | 8.)SHOW MANEUVERING CLEARANCE FOR DOOR | | 106, PUSH SIDE, FBC11 FIGURE 25. | | | | 9.)THE STAIR HANDRAIL AT THE BOTTOM OF | | THE STAIR IS TO COMPLY WITH | | FBC11-4.8.5(6), FIGURE 11-19. | | | | 10.)SHOW THE DIMENSION OF THE HANDRAIL | | EXTENSION AT THE TOP OF THE STAIR, | | FBC1009.11.5. | | | | 11.)SHOW LANDING AND DOOR DIMENSIONS, | | FBC1009.4, EXCEPTION 2. | | | | 12.)PROVIDE EITHER AN APPROVED | | ASSEMBLY OR CALCULATED FIRE RESISTANCE | | FOR THE 1 HOUR WALL, FBC7. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2006-07-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-28 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-28 |
Time |
19:42 |
Sent To |
|
|
Notes |
2006-07-28 00:00:00 | REV'S OK, STAMPED PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-02 |
Time |
06:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-02 |
Time |
06:47 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | **** UNSAT ***** | | | | 1) NOTE: PLEASE SEE PREVIOUS PLANS WERE | | REDLINED FOR FBC CHAPTER 13, HOWEVER | | COMPLIANCE FOR THIS NOT YET FULLY | | IMPLEMENTED ON PLANS. | | PLEASE SEE 13-415.1.ABC.1.1 , .2,.3 | | PLEASE ADJUST PLANS AND SUBMIT. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-03-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-27 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-24 |
Time |
21:56 |
Sent To |
|
|
Notes |
2006-03-27 00:00:00 | PLANS ARE REDLINED FOR FBC 2004, | | 13-415.1.ABC.1.1&.2 | | | | | | PASSED PENDING SUBMITTALS FOR UPS TO BE | | BROUGHT IN FOR REVIEW. | | CALLED ARCHITECT'S OFFICE AND LEFT | | MESSAGE 7:10AM 3/27. | | | | | | | | | | *** PLEASE KNOW, ALL REVISIONS/OPTIONS | | MUST BE SUBMITTED FOR REVIEW BEFORE | | ROUGH ELECTRICLA INSPECTION. | 2006-03-24 00:00:00 | IN ELEC FOR REVIEW, ELECTRICALREVIEW | | TO BE COMPLETED ON 3/27/06 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
21:34 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-02-08 |
Time |
21:09 |
Sent To |
|
|
Notes |
2006-02-08 00:00:00 | ******** UNSAT 3RD REVIEW ********** | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | TWO REVIEWS ARE NOT ADDRESSED. | | PLEASE SEE NEW NOTE FOR CHANGE IN PLANS. | | PLEASE SEE NOTES BELOW WHICH ARE | | DIRECTLY TAKEN FROM PREVIOUS REVIEW. | | | | *** UNSAT 2ND REVIEW *** | | | | PLEASE SEES SOME NOTES FROM PREVIOUS | | REVEW STILL NEED TO BE ADDRESSED. | | PLEASE SEE BELOW NOTES ARE TAKEN | | DIRECTLY FROM THOSE NOTES. | | | | 1)NOTE: OK | | | | 2)NOTE: OK | | | | 3)NOTE:NO. PLEASE SEE PANEL SCHEDULES | | OR LOAD CALCUALTIONS DO NOT INDICATE ANY | | CONTINUOUS OR LARGEST MOTOR LOADS?? | | | | ** NOTE #3 NO, PLEASE SEE THAT ALL | | CONTINUOUS LOADS AND LARGEST MOTOR LOADS | | ARE SHOWN AT 125%. | | 215.3,230.42 ETC. | | | | 4)NOTE: OK | | | | 5)NOTE: OK | | | | 6)NOTE: NOTE #6 NO, PLEASE SUBMIT AIC | | RATINGS FOR ALL NEW SERVICE EQUIPMENT | | BEING INSTALLED. MAINS/BRKRS AND PANELS | | ARE ALL TO BE RATED FOR THE AVAILABLE | | FAULT CURRENT.PER 110.9/215.5 | | ** IT IS NOTED THAT THE AIC RATINGS WERE | | SHOWN FOR PANELS , HOWEVER SHOW NEW MAIN | | DISCONNECT RATING ALSO. | | | | NEW NOTE: | | 7)NOTE:NO, PLEASE SEE THE FEE AS | | REQUIRED UNDER FLORIDA STATUE HAS NOW | | BEEN ACCESSED AND IS REQUIRED TO BE PAID | | BEFORE PLANS CAN BE RESUBMITTED. | | A FEE OF $4,293.60 IS NOW OWED. | | PLEASE SEE ONE SET OF PLANS ARE NOW | | BEING RETAINED FOR FILE. | | IT IS STRONGLY RECOMMEDED A MEETING BE | | HELD BEFORE RESUBMITTING PLANS TO | | ALLEAVIATE ANY FURTHER DELAYS OR FINES. | | PLEASE SEE COPY OF FS | | 553.80(2)(B) WITH RESPECT TO THE DESIGN | | PROFESSIONAL AND REPEAT COMMENTS. THIS | | IS ONLY A NOTICE GIVEN AT THIS TIME. | | | | ******* NEW NOTE ******** | | | | 1)NOTE: PLEASE SEE RISER NOW INDICATES A | | NEW UPS SYSTEM BEING INSTALLED HOWEVE NO | | INFORMATION HAS BEEN SUBMITTED FOR THIS | | SYSTEM. PLEASE ALSO BE SURE VALUE FOR | | THIS SCOPE OF WORK IS ADJUSTED EVEN IF | | OWNER SUPPLIED. FBC 108.3 ADMINISTRATIVE | | SECTION OF THE LOCAL ADMINISTRATIVE | | CODE. | | UNABLE TO REVIEW AS NOT ENOUGH | | INFORMATION IS SUBMITTED. | | PLEASE ALSO SEE ROOM IS NOW BEING LABLED | | AS A "NETWORK ROOM"?? PLEASE CLARIFY USE | | AS IF THIS ROOM IS AN IT ROOM, | | REQUIREMENTS OF 645 AND NFPA-75 MAY | | APPLY. | | THIS MAY ALSO AFFECT MECHANICAL, AND | | BLDG SHEETS. | | | | 2)NOTE: PLEASE SEE FBC CHAPTER 13, | | 13-415.1ABC.1.1,.2 | | PLEASE KNOW, THIS WAS NOT ON PREVIOUS | | REVIEW, HOWEVER IS REQUIRED UNDER THE | | 2004 FBC WHICH PLANS ARE NOW SHOWN TO BE | | DESIGNED UNDER. | | | | | | ** ONE COPY OF ALL OLD VOIDED SHEETS | | WERE NOT SUBMITTED AS REQUESTED. | | | | ** PLEASE REMOVE ANY OLD/VOIDED SHEETS | | AND ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | ONLY ONE COPY OF THE OLD VOIDED SHEETS | | NEED TO BE SUBMITTED FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THEREARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-23 |
Time |
07:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-23 |
Time |
06:33 |
Sent To |
|
|
Notes |
2005-12-23 00:00:00 | *** UNSAT 2ND REVIEW *** | | | | PLEASE SEES SOME NOTES FROM PREVIOUS | | REVEW STILL NEED TO BE ADDRESSED. | | PLEASE SEE BELOW NOTES ARE TAKEN | | DIRECTLY FROM THOSE NOTES. | | | | 1)NOTE: NOTE #1 NO, PLEASE KNOW THAT ALL | | DESIGNS/PLANS SUBMITTED FOR PERMIT AFTER | | OCT 1ST, 2005 SHALL FALLUNDER THE 2004 | | FBC. | | PLEASE ADJUST ALL SHEETS CONTAINING | | REFERENCE TO THE 2001 FBC. PLEASE ALSO | | SEE ALL MEP'S ,PLEASE SEE NOTES ON THESE | | SHEETS WITH REFERENCE TO THE 2001. | | PLEASE SEE SOME SHEETS HAD THESE CHANGES | | MADE. PLEASE SEE ELECTRICAL SHEET NOW | | HAS MISSING NOTES, PLEASE BE SURE TO | | SPECIFY THE NEC CURRENTLY IN | | EFFECT.(2002), NFPA-101 2003, NFPA-72, | | 2002 | | | | 2)NOTE: NOTE #2 NO/YES,PLEASE SEE | | MISSSING CONDUCTORS FROM GUTTER TO | | METER. PLEASE SEE OTHER TO PANEL FROM | | TENANT DISCONNECT WERE ADDED. | | 215.5, 310.16,240.4 ETC. | | | | 3)NOTE:NOTE #3 NO, PLEASE SEE THAT ALL | | CONTINUOUS LOADS AND LARGEST MOTOR LOADS | | ARE SHOWN AT 125%. | | 215.3,230.42 ETC. | | | | 4)NOTE: NOTE #4 NO, PLEASE INDICATE | | ATTACHMENT LOCATION FOR TRANSFORMER PER | | 250.30 | | PLEASE SEE THIS IS REQUIRED TO BE SHOWN | | BACK TO THE EXISTING GROUNDING ELECTRODE | | SYSTEM.(NOTES, ONE LINE) ETC | | | | 5)NOTE: NOTE #5 NO, PLEASE SEE MAIN IS | | LABLED 1OF 1, HOWEVER RISER SHOWS TWO | | MAINS. THE OTHER IS SHOWN 2 OF 2. , THE | | OTHER SHOULD BE LABLED 1 OF 2. | | | | 6)NOTE: NOTE #6 NO, PLEASE SUBMIT AIC | | RATINGS FOR ALL NEW SERVICE EQUIPMENT | | BEING INSTALLED. MAINS/BRKRS AND PANELS | | ARE ALL TO BE RATED FOR THE AVAILABLE | | FAULT CURRENT.PER 110.9/215.5 | | ** IT IS NOTED THAT THE AIC RATINGS WERE | | SHOWN FOR PANELS , HOWEVER SHOW NEW MAIN | | DISCONNECT RATING ALSO. | | | | NEW NOTE: | | 7)NOTE: PLEASE SEE COPY OF FS | | 553.80(2)(B) WITH RESPECT TO THE DESIGN | | PROFESSIONAL AND REPEAT COMMENTS. THIS | | IS ONLY A NOTICE GIVEN AT THIS TIME. | | | | ** PLEASE REMOVE ANY OLD/VOIDED SHEETS | | AND ONLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | ONLY ONE COPY OF THE OLD VOIDED SHEETS | | NEED TO BE SUBMITTED FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THEREARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-15 |
Time |
13:53 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-11-15 |
Time |
12:31 |
Sent To |
|
|
Notes |
2005-11-15 00:00:00 | ********* UNSAT *********** | | | | 1)NOTE: PLEASE KNOW THAT ALL | | DESIGNS/PLANS SUBMITTED FOR PERMIT AFTER | | OCT 1ST, 2005 SAHLL FALLUNDER THE 2004 | | FBC. | | PLEASE ADJUST ALL SHEETS CONTAINGIN | | REFERENCE TO THE 2001 FBC. PLEASE ALSO | | SEE ALL MEP'S ,A-SHEETS WITH RESPECT TO | | REFERENCED CODES, TABLES ETC. | | | | 2)NOTE: PLEASE SEE MISSSING CONDUCTORS | | ON RISER DIAGRAM FROM GUTTER TO METER, | | METER TO MAIN AND TO SUB PANEL. | | 215.5, 310.16,240.4 ETC. | | | | 3)NOTE: PLEASE SEE THAT ALL CONTINUOUS | | LOADS AND LARGEST MOTOR LOADS ARE SHOWN | | AT 125%. | | 215.3,230.42 ETC. | | | | 4)NOTE: PLEASE INDICATE ATTACHMENT | | LOCATION FOR TRANSFORMER PER 250.30 | | | | 5)NOTE: PLEASE SEE MAIN IS LABLED 1OF 1, | | HOWNER RISER SHOWS TWO MAINS. THE OTHER | | IS SHOWN 2 OF 2. , THE OTHER SHOULD BE | | LABLED 1 OF 2. | | | | 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | IT IS NOTED THAT THE AIC RATINGS WERE | | SHOWN FOR PANELS , HOWEVER SHOW NEW MAIN | | DISCONNECT RATING ALSO. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THEREARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-08-31 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-08-31 |
Time |
13:12 |
Sent To |
|
|
Notes |
2006-08-31 00:00:00 | REVISION DATED 7/17/06 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-02 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-02 |
Time |
11:14 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | NEW SHEETS | | | | ALL WORK SHALL COMPLY WITH APPLICABLE | | BUILDING CODES, AND NFPA 101, 2003 | | EDITION, SECTION 7.5.4 (ACCESSIBLE MEANS | | OF EGRESS). | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-03-29 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-03-29 |
Time |
10:15 |
Sent To |
|
|
Notes |
2006-03-29 00:00:00 | PASSED ON 11/10/05 BY M. CARSILLO |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2006-02-15 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2006-02-15 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2006-02-15 |
Time |
17:03 |
Sent To |
|
|
Notes |
2006-02-08 00:00:00 | NEW SHEETS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2005-12-23 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2005-12-23 |
Time |
09:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2005-11-10 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2005-11-10 |
Time |
13:25 |
Sent To |
|
|
Notes |
2005-11-10 00:00:00 | 1. PORTABLE FIRE EXTINGUISHERS ARE | | REQUIRED. THEY ARE TO BE TYPE 2A 10BC | | PORTABLE FIRE EXTINGUISHERS CURRENTLY | | SERVICE TAGGED AND MOUNTED. | | | | 2. AISLES BETWEEN THE WORK STATIONS | | LOCATED IN THE OPEN WORK AREA SHALL BE | | ARRANGED TO PROVIDE FOR THE MINIMUM | | CLEARNCE OF 44 INCHES. THE PLANS SEEM TO | | REFLECT MORE WHICH IS ACCEPTABLE. | | | | 3. CONSTRUCTION, DEMOLITION, AND | | RENOVATION TO COMPLY WITH NFPA 241. | | | | 4. DEBRIS SHALL BE REMOVED DAILY FROM | | THE SITE. | | | | 5. EXISTING HANDRAILS AND GUARDRAILS ARE | | TO MEET THE PRESCRIPTIVE STRENGTH | | REQUIREMENTS OF THE BUILDING AND FIRE | | CODES. | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | OFFICER. | | 804-4709 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2006-09-13 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2006-09-13 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2006-09-13 |
Time |
13:23 |
Sent To |
|
|
Notes |
2006-09-13 00:00:00 | SUBMITTAL/RESTAMP GIVEN DIRECTLY TO | | PATTY KRAUSS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-07-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-28 |
Time |
18:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-28 |
Time |
18:29 |
Sent To |
|
|
Notes |
2006-07-28 00:00:00 | TO COMM BOARD #23 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-14 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-14 |
Time |
15:17 |
Sent To |
|
|
Notes |
2006-07-14 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-14 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-14 |
Time |
13:01 |
Sent To |
B |
|
Notes |
2006-07-14 00:00:00 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-12 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-12 |
Time |
13:53 |
Sent To |
M |
|
Notes |
2006-06-12 00:00:00 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-18 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-05-18 |
Time |
14:37 |
Sent To |
|
|
Notes |
2006-06-02 00:00:00 | 6/2/06-TAKEN FROM "COMM" BD TO BLDG AND | | FIRE. | | GAVE TO MR FOR FIRE REVIEW | | ON SMH DESK | | | 2006-05-26 00:00:00 | TO "COMM" BD#1-REV | 2006-05-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
19:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-23 |
Time |
19:58 |
Sent To |
|
|
Notes |
2006-03-23 00:00:00 | TO COMM BOARD SPACE #, 48, NEEDS B, | | F(FOR FIRE SPRINKLER LAYOUT), E, AND | | M(NEW SHEETS). |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-03-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-02 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-02 |
Time |
16:01 |
Sent To |
|
|
Notes |
2006-03-02 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-17 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-17 |
Time |
18:57 |
Sent To |
|
|
Notes |
2006-02-07 00:00:00 | TO "COMM" BD#11 | 2006-01-17 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-11-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-30 |
Time |
18:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-30 |
Time |
18:57 |
Sent To |
|
|
Notes |
2005-12-22 00:00:00 | TO "COMM" BD#53 | 2005-11-30 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-21 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-04 |
Time |
13:32 |
Sent To |
|
|
Notes |
2005-10-13 00:00:00 | TO "COMM" BD#10 | 2005-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
7 |
Status |
P |
Date |
2006-09-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-09-13 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-09-13 |
Time |
13:25 |
Sent To |
|
|
Notes |
2006-09-13 00:00:00 | RE-STAMP |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-19 |
Time |
16:13 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-06-19 |
Time |
16:13 |
Sent To |
|
|
Notes |
2006-06-19 00:00:00 | REVISION TO MECH. PLANS PAGE M1.1 AND | | M3-1. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-03-29 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-03-29 |
Time |
07:00 |
Sent To |
|
|
Notes |
2006-03-29 00:00:00 | PROVISO FROM 2-8-06 WAS NOT ADDRESSED. | | AIR FROM BATHROOM AREAS SHALL NOT BE | | RECIRCULATED IN ACCORDANCE WITH 2004 FMC | | TABLE 403.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. | 2006-03-22 00:00:00 | NEEDS MECH REVIEW, NEW/ REVISED SHEETS | | IN SETS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2006-02-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-02-08 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-02-08 |
Time |
15:03 |
Sent To |
|
|
Notes |
2006-02-08 00:00:00 | PROVISO: | | PLAN SHEET M1.1, RETURN AIR FROM RTU-2 | | IS INDICATED IN THE RESTROOM AREAS. | | PLEASE NOTE, AIR FROM BATHROOMS SHALL | | NOT BE RECIRCULATED, EXHAUST ONLY IN | | ACCORDANCE WITH 2004 FMC TABLE 403.3. | | PLEASE REMOVE RETURN AIR FROM THE | | BATHROOM AREAS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2006-01-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-01-05 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-01-05 |
Time |
08:57 |
Sent To |
|
|
Notes |
2006-01-05 00:00:00 | DENIED: | | SEE COMMENTS FROM REVIEW DATED 11-15-05 | | (ATTACHED).PLANS ARE OTHERWISE CODE | | COMPLIANT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-11-15 |
Time |
15:23 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2005-11-15 |
Time |
15:23 |
Sent To |
|
|
Notes |
2005-11-15 00:00:00 | DENIED: | | PLEASE REVISE PLANS TO REFERENCE CURRENT | | CODE.2004 FLORIDA BUILDING CODE WENT | | INTO EFFECT 1 OCTOBER 2005. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
prafter |
Date |
2005-10-06 |
Time |
10:11 |
Rev Time |
1.00 |
Received By |
prafter |
Date |
2005-10-06 |
Time |
10:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-02-03 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-02-03 |
Time |
12:40 |
Sent To |
|
|
Notes |
2006-02-03 00:00:00 | PROVISO: VENTS ADDED TO URINALS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-01-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-01-04 |
Time |
13:48 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2006-01-04 |
Time |
13:48 |
Sent To |
|
|
Notes |
2006-01-04 00:00:00 | DENIED; | | 1.SECOND REQUEST; SHOW COMPLIANCE TO | | FBC-2004 PLUMBING TABLE 403.1. SHOW | | OCCUPANCY CLASSIFICATION, NUMBER OF | | EMPLOYEES | | 2.WATER RISER; WATER HAMMER ARRESTORS | | ARE REQUIRED BY MANUFACTOR'S | | INSTALLATION INSTRUCTIONS TO BE AS CLOSE | | TO THE SORCE OF HAMMER. PLEASE INSTALL | | WHA'S AT THE BOTTOM OF DROPS. | | 3.BREAK ROOM SINK DOES NOT COMPLY WITH | | FBC-2004 CHAPTER 11 SEC.11-4.24.3 KNEE | | CLEARANCE; 19" REQUIRED. | | 4.SANITARY RISER DIAGRAM; PLEASE INSTALL | | URINALS USING SANITARY TEE'S (ONE SET OF | | PLANS MARKED IN RED) | | | | DO NOT SHOW TRAPS ON URINALS TRAPS | | BUILT INTO FIXTURE. | | 5.SANITARY RISER DIAGRAM; 3" PIPE | | REQUIRED TO WET VENT BOTH FLOOR DRAINS | | IN BATHROOMS FBC-2004 PLUMBING TABLE | | 909.3 WET VENT SIZE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-06 |
Time |
12:56 |
Rev Time |
1.50 |
Received By |
jleech |
Date |
2005-10-06 |
Time |
12:56 |
Sent To |
|
|
Notes |
2005-10-06 00:00:00 | DENIED; | | 1.PLUMBING NOTES; NOTE #1 CHANGE TO 2004 | | CODE. | | 2.SHOW COMPLIANCE TO FBC-2004 PLUMBING | | TABLE 403.1. SHOW CAULK'S ON PLUMBING | | PAGE. | | 3.WATER RISER; BREAK SINK DROP NOT | | SHOWN. PLEASE SHOW WATER HAMMER | | ARRESTORS AT THE BOTTOM OF DROPS. | | MANUFACTOR INSTALLATION INSTRUCTIONS, TO | | BE INSTALLED AS CLOSE TO THE SOURCE OF | | THE HAMMER. | | 4.BREAK ROOM SINK MUST COMPLY WITH | | FBC-2004 BUILDING CHAPTER 11 SEC. | | 11-4.24.1 THRU 11-4.24.7. (SHOW DETAIL) | | 5.SANITARY ISOMETRIC; BREAK SINK NOT | | VENTED. URINALS ARE "S" TRAPED. USE | | SANITARY TEE'S OFF OF VENT STACK. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-08-08 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-08-08 |
Time |
16:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-07-30 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-07-30 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-07-30 |
Time |
14:14 |
Sent To |
|
|
Notes |
2006-07-30 00:00:00 | 7/30/2006 ***FAILED*** | | | | 1) REVISIONS SUBMITTED DO NOT MATCH THE | | LATEST MINOR AMENDMENT APPROVAL, WHICH | | PROVIDES FOR THE LOCATION OF A HC SPACE | | AT THE REAR OF THE BUILDING. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | SENIOR PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-06-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-06-07 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-06-07 |
Time |
13:54 |
Sent To |
|
|
Notes |
2006-06-07 00:00:00 | 6/7/2006 ***FAILED*** | | | | 1) MODIFICATIONS TO THE PARKING AND | | LANDSCAPING REQUIRE SUBMISSION AND | | APPROVAL OF A MINOR PLANNED DEVELOPMENT | | (PD) AMENDMENT APPLICATION TO THE | | PLANNING AND ZONING DEPARTMENT.THIS | | MUST BE DONE PRIOR TO BUILDING PERMIT. | | | | FOR INFORMATION PERTAINING TO THIS | | REQUIREMENT, PLEASE CONTACT JOHN ROACH, | | SENIOR PLANNER, AT (561) 822-1435. |
|
|