Plan Review Details - Permit 05091714
Plan Review Stops For Permit 05091714
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-13 Cont ID  
Sent By alange Date 2006-07-13 Time 15:40 Rev Time 0.00
Received By alange Date 2006-07-13 Time 15:40 Sent To  
Notes
2006-07-13 00:00:00PLAN REVIEW DENIED
  
 ITEMS NEEDED TO BE INCLUDED WITH PLANS
 FOR BEFORE PERMITTING.
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 4.PLANS SHALL BE SIGNED, SEALED AND
 DATED BY THE ARCHITECT AND ENGINEERS OF
 RECORD.FS 481.221 AND 471.025SEE
 ELECTRICAL REVIEW REGARDING THIS AND
 TITLE BLOCK ISSSUES.
  
 7.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THE FOLLOWING, FLAT
 ROOFING AND SELECT THE ASSEMBLY USED
 ALL EXTERIOR EQUIPTMENT DOORS, STRAPS
 AND TIE-DOWNS.
  
 8.SUBMIT THE FOLLOWING STATE PRODUCT
 AND ATTACHE TO THE PRODUCT APPROVALS
 USED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 14.SHOW A SPRINKLER SYSTEM COMPLYING
 WITH TABLE 500 NOTE "D".
  
 15.SUBMIT TWO ORIGONALS OF A SOILS
 REPORT SHOWING FOUNDATION AND FOOTING
 RECOMMENDATIONS.
  
 17.ROOF SHEATHING SHALL COMPLY WITH
 FBC 2322.2.5 AND WEST PALM BEACH
 AMMENDMENTS TABLE 2306.1.SHOW ROOF
 FASTENING ZONES ON PLANS.
  
 18.THE 2 HOUR RATED WALL BETWEEN
 GARAGE AND LIVING SPACE SHALL HAVE A
 DOOR RATED IN COMPLIANCE WITH FBC TABLE
 705.1.2.
  
 NEW COMMENTS:
 A.HAND DRAWN CHANGES NOT PERMITTED TO
 PLANS.FBC 2001 WPB AMMENDMENTS
 104.2.1.3
  
 B.PLANS SPEC THAT THEY ARE DESIGNED TO
 THE 2001 FBC YET PAGE SD1.O STILL
 REFLECTS THE 2004 FBC.
  
 IMPORTANT:
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-13 Cont ID  
Sent By alange Date 2006-07-13 Time 15:41 Rev Time 0.00
Received By alange Date 2006-07-13 Time 15:41 Sent To  
Notes
2006-07-13 00:00:00PLAN REVIEW DENIED
  
 ITEMS NEEDED TO BE INCLUDED WITH PLANS
 FOR BEFORE PERMITTING.
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SHOW BUILDING TYPE ON PLANS PER
 2004 FBC 602.
  
 4.PLANS SHALL BE SIGNED, SEALED AND
 DATED BY THE ARCHITECT AND ENGINEERS OF
 RECORD.FS 481.221 AND 471.025
  
 5.PLEASE CLEARIFY IF THE UNITS WILL BE
 FEE SIMPLE OF LEASEHOLD TITLE.
 SHOW WEATHER UNITS WILL BE TOWNHOUSE OR
 CONDO.
  
 6.W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 7.SUBMIT TWO COMPLETE SETS OF PRODUCT
 APPROVALS FOR THE FOLLOWING, ROOFING,
 FLAT AND TILE, ALL EXTERIOR DOORS
 INCLUDING EQUIPTMENT DOORS, STRAPS AND
 TIE-DOWNS, LINTELS AND OVERHEAD GARAGE
 DOORS.
  
 8.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 9.PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2004 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 10.2004 FBC11-4.8.2 SLOPE & RISE.
 THE LEAST POSSIBLE SLOPE SHALL BE USED
 FOR ANY RAMP. THE MAXIMUM SLOPE FOR A
 RAMP IN NEW CONSTRUCTION SHALL BE 1 TO
 12. THE MAXIMUM RISE FOR RUN SHALL BE
 30" (SEE FIGURE 16).SHOW DETAILS FOR
 RAMPS USED.
  
 11. 2004 FBC 1607.7.1.1 THE GUARDRAIL
 SYSTEM SHALL BE DESIGNED AND CONSTRUCTED
 TO RESIST A 200 LB CONCENTRATED
 HORIZONTAL LOAD APPLIED ON A 1 SQ FT
 AREA AT ANY POINT IN THE SYSTEM
 INCLUDING INTERMEDIATE RAILS OR OTHER
 ELEMENTS SERVING THIS PURPOSE.SHOW
 DETAILS ON PLANS.
  
 12.ONCE CONSTRUCTION TYPE IS SELECTED
 THE BUILDING VALUATION WILL BE REVISED
 ACCORDING TO ICC BUILDING VALUATION
 DATA.REVISE PERMIT VALUATION TO
 REFLECT THIS TABLE AND PAY ADDITIONAL
 PERMIT FEES.
  
 13.PRODUCT APPROVAL SUBMITTED IS FOR
 AN OUT SWING FRENCH DOOR. SHOW LOCATION
 ON SCHEDULE.
  
 14.SHOW A SPRINKLER SYSTEM COMPLYING
 WITH FBC 903.3.1.1
  
 15.SUBMIT TWO ORIGONALS OF A SOILS
 REPORT SHOWING FOUNDATION AND FOOTING
 RECOMMENDATIONS.
  
 16. A23 A NOTE: *" CMU WALL WITH 3/4"
 PAINTED FINISH? PLEASE SUBMIT MORE
 INFORMATION.
  
 17.ROOF SHEATHING SHALL COMPLY WITH
 FBC 2304.9.1 #31
  
 18.THE 2 HOUR RATED WALL BETWEEN
 GARAGE AND LIVING SPACE SHALL HAVE A
 DOOR RATED IN COMPLIANCE WITH FBC 715.3
  
 19.INSUFFICIENT INFORMATION SUBMITTED
 FOR CLUB HOUSE REVIEW.SUBMIT PLANS TO
 A MINIMUM OF 1/8" SCALE WITH ALL THE
 REQUIRED STRUCTURAL DETAILS FOR REVIEW.
 FBC 106.1.3 AND 106.1.2, 106.3.5 WPB
 AMMENDMENTS TO THE 2004 FBC.
  
 20.SUBMIT BBQ SPECS AND HOOD DETAILS
 FOR CLUB HOUSE.
  
 21.POOL AND FENCING TO BE UNDER A
 SEPERATE PERMIT.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-11 Cont ID  
Sent By dpalmer Date 2006-06-11 Time 19:36 Rev Time 0.00
Received By dpalmer Date 2006-06-11 Time 17:24 Sent To  
Notes
2006-06-11 00:00:00IN ELEC
 ** UNSAT ***
  
 1) NOTE: PLEASE KNOW, THE ELECTRICAL
 LAYOUT, RISER ETC IS OK FOR CLUBHOUSE,
 HOWEVER CAN NOT STAMP AS SEPARATE PLANS,
 AND INFORMATION ON SAID TITLE BLOCKS ARE
 IN NEED OF CORRECTING.
 SEE REVIEWS UNDER 05091965
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-25 Cont ID  
Sent By dpalmer Date 2005-12-25 Time 09:15 Rev Time 0.00
Received By dpalmer Date 2005-12-24 Time 18:21 Sent To  
Notes
2005-12-25 00:00:00********** UNSAT **********
  
 DIXIE MEWS/ AQUA TERRACE
  
 CLUBHOUSE.
  
 1)NOTE: PLEASE KNOW, NO REVIEW WAS DONE
 FOR CLUBHOUSE, AS ELECTRICAL PLANS COULD
 NOT BE LOCATED.
  
 PLEASE SUBMIT.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
2005-12-24 00:00:00IN ELEC FOR REVIEW

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2005-10-14 Cont ID  
Sent By mamini Date 2005-10-14 Time 15:31 Rev Time 0.50
Received By mamini Date 2005-10-14 Time 15:31 Sent To  
Notes
2005-10-14 00:00:00FAILED:
  
 1. CIVIL PLANS MUST BE REVIEWED AND
 APPROVED FOR ALL THE CONNECTIONS TO THE
 CITY' SERVICES, 494-1085 ATT; MANNY
 GONZALEZ.
 2. PLEASE SUBMIT STORM WATER
 CALCULATIONS FOR OUR REVIEW AND
 APPROVAL.NOTE THAT SITE MUST BE
 DESIGNED PER CITY' REQUIREMENTS AND
 CRITERIA.CALC. MUST BE SIGNED AND
 SEALED BY THE C.E.O.R
 3. POLLUTION PREVENTION PLANS MUST BE
 INCLUDED IN CIVIL PLANS, SILT FENCE,
 TURBIDITY BARRIER, ECT..
 4.PLEASE SUBMIT A COPY OF THE SFWMD
 PERMIT, FOR OUR RECORD.
 5. PLEASE REFER TO ARCHITECTURAL PLANS
 FOR DUMPSTER ENCLOSURE'S DIMENSIONS.
 NOTE THAT, THEY MUST BE SIZED PER CITY
 REQUIREMENTS IF CITY PICK-UP.
 6. STREETSCAPING AND SIDEWALKS, ETC.
 MUST BE COORDINATED WITH LATEST FDOT
 PLANS FOR RECONSTRUCTION OF DIXIE AND
 GREGORY RD.
 7. CIVIL PLANS MUST BE INCLUDED IN ALL
 THREE SETS, ONLY ONE SET HAS THE CIVIL.
 8. NOTE THAT CITY'S STANDARDS AND
 DETAILS CAN BE OBTAINED FROM PUBLIC
 UTILITIES AND ENGINEERING , 494-1085.
 9.FIRE HYD. MUST BE PROVIDED
 THROUGHOUT THE PROPOSED SITE.
 10. DOMESTIC WATER SYS. AS PROPOSED;
 METERS AND DDCV LOCATIONS ECT. MUST BE
 VERIFIED WITH PUBLIC UTILITIES AND
 ENGINEERING.
 11. ALL VERTICAL CLEARANCES FOR
 UNDERGROUND UTILITIES MUST BE SHOWN.
 12. A SEPARATE R.O.W PERMIT FOR ALL THE
 WORKS WITHIN PUBLIC R.O.W IS REQUIRED;
 CONTACT PUBLIC UTILITIES AND ENGINEERING
 AT MIN. 48HR PRIOR TO ANY WORK BEGINS,
 494-1086, WINDEL PALMER. NOTE TO G.C
 13. ACCESS RAMP PER INDEX 304 FDOT TO
 THE SITE MUST BE PROVIDED.
 14. DETAILS FOR THE STOP AND HANDICAP
 SIGNS SHOULD BE INCLUDED IN CIVIL, AND
 NOTE THAT PARKING STALLS MUST BE PAINTED
 WITH DOUBLE 4" WIDE, DETAILS SHOULD BE
 SHOWN.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-07-18 Cont ID  
Sent By mwennerg Date 2006-07-18 Time 15:26 Rev Time 0.00
Received By mwennerg Date 2006-07-18 Time 15:26 Sent To  
Notes
2006-07-18 00:00:00***DENIED***
  
 PLEASE NOTE THAT A RESPONSE LETTER
 ADDRESSING THE FIRE REVIEW WAS NOT FOUND
 WITH THIS SUBMITTAL. PLEASE BE ADVISED
 THAT THIS WILL HELP EXPEDITE THE PLAN
 REVIEW PROCESS.
  
 1) COMPLETE CIVIL DRAWINGS ARE TO BE
 SUBITTED ILLUSTRATING FIRE HYDRANTS AND
 WATER AND FIRE MAIN SIZES. ALL BACK FLOW
 PREVENTION DEVICES ARE TO BE SHOWN.
  
 2) FIRE HYDRANT SPACING IS NOT TO EXCEED
 300-500' APART.
  
 3) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
  
 4) SUITABLE ROADS ARE TO BE PROVIDED
 DURING CONSTRUCTION FOR EMERGENCY
 EQUIPMENT.
  
 5) BUILDING ADDRESSES ARE REQUIRED. A
 MINIMUM OF AT LEAST 6" HIGH NUMBERS ARE
 REQUIRED.
  
 6) ALL FIRE HYDRANTS ARE TO BE PROVIDED
 WITH PROPER CLEARANCES TO THE FRONT AND
 SIDES OF THEM.
  
 7) ALL HANDRAILS AND GUARDS ARE TO MEET
 PRESCIPTIVE STRENGTH REQUIREMENTS PER
 THE FLORIDA BUILDING CODE AND THE
 FLORIDA FIRE PREVENTION CODE.
  
 8) PLEASE EXPLAIN STORAGE AREAS NEAR
 EXIT STAIRS LOCATED ON THE SECOND FLOOR,
 CENTER CORE.
  
 9) A COMPLETE AUTOMATIC SUPERVISED FIRE
 SPRINKLER SYSTEM IS REQUIRED IN ALL (3)
 STORY BUILDINGS. PLEASE COMPLETE PLANS
 AND PERMITS AS REQUIRED.
  
 10) THE FIRE ALARM SYSTEM IS TO BE
 MONITORED BY A LICENSED UL LISTED
 CENTRAL STATION APPROVED FOR CENTRAL
 STATION SERVICE. COMPLETE PLANS AND
 PERMITS REQUIRED PRIOR TO INSTALLATION.
  
 11) FIRE LINE BACKFLOW DEVICE SHALL BE
 EQUIPPED WITH TAMPER SWITCHES, CHAIN AND
 LOCK.
  
 12) A REVIEW OF THE CIVIL DRAWINGS
 INDICATE THAT ADDITIONAL FIRE HYDRANTS
 ARE NEEDED. FIRE DEPARTMENT SPRINKLER
 CONNECTIONS SHALL BE LOCATED NO FURTHER
 THAN 150' FROM A FIRE HYDRANT.
  
 13) THERE APPEARS TO BE NO FIRE HYDRANTS
 LOCATED ON THE APPROACH OR INTO THE
 COMPLEX.
  
 14) ALL SMOKE DETECTORS ARE TO BE
 INSTALLED A MINIMUM OF (3)' FROM HVAC
 DIFFUSERS.
  
 15) FIRE ALARM VISIBLE SIGNALS SHALL BE
 PROVIDED IN ROOMS DESIGNED FOR THE
 HEARING IMPAIRED.
  
 16)PLEASE INDICATE THE MINIMUM INTERIOR
 FINISH CLASSIFICATION FOR WALLS AND
 CEILINGS.
  
 17) ALL RESIDENTIAL BUILDINGS ARE TO
 COMPLY WITH CHAPTER 30, NFPA 101, 2003
 EDITION.
  
 18) ALL COMMON BUILDING STAIRS ARE TO BE
 PROVIDED WITH EMERGENCY LIGHTING
 EQUIPMENT.
  
 19) PLEASE EXPLAIN EXIT DISCHARGE FROM
 COMMON STAIRS. IT APPEARS THAT BOTH
 EMPTY INTO THE BUILDING. PLEASE EXPLAIN
 WHAT ALLOWS THIS TO OCCUR.
  
 20) EMERGENCY INSTRUCTIONS FOR RESIDENTS
 OR GUESTS ARE REQUIRED.
  
 21) KNOX BOXES WILL BE REQUIRED FOR THE
 COMMON ELEMENTS OF THE BUILDING.
  
 22) PORTABLE FIRE EXTINGUISHERS WITH BE
 REQUIRED.
  
 23) ARE THE GARAGE DOORS PROPERLY RATED?
 IT APPEARS THAT THE DOOR SCHEDULE
 DISPLAYS 45 MINUTES BUT THE GARAGE WALL
 IS OF GREATER VALUE.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-01 Cont ID  
Sent By adarroug Date 2006-05-01 Time 16:39 Rev Time 0.00
Received By adarroug Date 2006-05-01 Time 16:38 Sent To  
Notes
2006-05-01 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-01 Cont ID  
Sent By adarroug Date 2006-02-03 Time 16:38 Rev Time 0.00
Received By adarroug Date 2005-10-05 Time 11:48 Sent To  
Notes
2005-10-05 00:00:00TO "COMM" BD#23/PLANS ON RACK/1 ROLL

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-06 Cont ID  
Sent By pkrauss Date 2006-07-06 Time 07:04 Rev Time 0.00
Received By pkrauss Date 2006-07-05 Time 15:03 Sent To  
Notes
2006-07-06 00:00:00DENIED:2001 FBC/CLUBHOUSE
  
 PLAN SHEET M-9, PLEASE NOTE, EF-2 IS
 WITHIN 10 FT OF THE O/A INTAKE LOUVER.
 PER 2001 FMC 501.3, MECHANICAL EXHAUST
 SHALL TERMINATE OUTDOORS AT A POINT
 WHERE IT WILL NOT CAUSE A NUISANCE AND
 FROM WHICH IT CANNOT BE READILY DRAWN IN
 BY VENTILATING SYSTEM.
  
 EXHAUST SHALL NOT TERMINATE ONTO
 WALKWAYS PER 2001 FMC 401.5.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-01-13 Cont ID  
Sent By pkrauss Date 2006-01-13 Time 14:12 Rev Time 0.00
Received By pkrauss Date 2006-01-13 Time 13:36 Sent To  
Notes
2006-01-13 00:00:00DENIED:CLUBHOUSE
  
 COULD NOT FIND PLANS FOR THE CLUBHOUSE
 IN THIS SUBMITTAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pschmitz Date 2006-07-16 Time 11:22 Sent To  
Notes
2006-07-16 00:00:00PAUL SCHMITZ
 [email protected]
 FBC2001 FUEL GAS CODEPLAN REVIEW
 FBC 2001 PLUMBING CODEPLAN REVIEW
 FBC 2001 FL ACESSIBILITY CODE PLAN
 REVIEW
  
 UNSAT
  
 PREVIOUS COMMENTS NOT ADDRESSED.
 DATED 01-26-06 BY KEN STEVENS
  
  
 1. AS REQUIRED BY 104.3.1.1 OF THE CODE,
 TWO OR MORE COPIES OF SPECIFICATIONS,
 AND OF DRAWINGS DRAWN TO SCALE WITH
 SUFFICIENT CLARITY AND DETAIL TO
 INDICATE THE NATURE AND CHARACTER OF THE
 WORK, SHALL ACCOMPANY THE APPLICATION
 FOR A PERMIT. NO PLANS FOR THE CLUBHOUSE
 HAVE BEEN SUBMITTED. NO REVIEW FOR
 CLUBHOUSE. SECTION 104.2.1.
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-01-26 Cont ID  
Sent By kstevens Date 2006-01-26 Time 08:09 Rev Time 0.00
Received By kstevens Date 2006-01-26 Time 08:09 Sent To  
Notes
2006-01-26 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 1. AS REQUIRED BY 104.3.1.1 OF THE CODE,
 TWO OR MORE COPIES OF SPECIFICATIONS,
 AND OF DRAWINGS DRAWN TO SCALE WITH
 SUFFICIENT CLARITY AND DETAIL TO
 INDICATE THE NATURE AND CHARACTER OF THE
 WORK, SHALL ACCOMPANY THE APPLICATION
 FOR A PERMIT. NO PLANS FOR THE CLUBHOUSE
 HAVE BEEN SUBMITTED. NO REVIEW FOR
 CLUBHOUSE. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-20 Cont ID  
Sent By eschneid Date 2006-07-20 Time 19:37 Rev Time 0.00
Received By eschneid Date 2006-07-20 Time 19:37 Sent To  
Notes
2006-07-20 00:00:001) THE CLUBHOUSE SIZE ON THE ENGINEERING
 PLAN DOES NOT MATCH THE CLUBHOUSE SIZE
 ON THE SITE AND LANDSCAPE PLANS. REPEAT
 COMMENT.
  
 2) SHOW DIMENSION LINES FOR ALL DRIVE
 AISLES AND DRIVEWAYS ON THE ENGINEERING
 PLANS.THE GREGORY ROAD ENTRY SCALES AT
 24 FEET WIDE ON THE ENGINEERING PLANS
 AND IS DIMENSIONED AT 22 FEET ON THE
 SITE PLAN. REPEAT COMMENT.
  
 3) PLEASE NOTE THAT WHEEL STOPS SHALL BE
 24 INCHES FROM THE ENDS OF THE PARKING
 SPACE.DISABLED LOGO SHALL BE 24 INCHES
 FROM THE PARKING SPACE ENTRANCE.
  
 4) PLEASE SHOW ELEVATION MARK FOR THE
 BUILDINGS ON ALL OF THE ELEVATION
 SHEETS.THE ADDITIONAL ELEVATION MARKS
 SHALL SHOW THE HIGHEST RIDGE HEIGHT AND
 THE HEIGHT TO THE TOP OF THE ROOFTOP
 MECHANICAL ROOM. REPEAT COMMENT.
  
 5) PLEASE NOTE THAT A RECORDED BOUNDARY
 PLAT IS REQUIRED PRIOR TO THE ISSUANCE
 OF A BUILDING PERMIT. REPEAT COMMENT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-03 Cont ID  
Sent By eschneid Date 2006-02-03 Time 16:07 Rev Time 0.00
Received By eschneid Date 2006-02-03 Time 16:06 Sent To  
Notes
2006-02-03 00:00:001) THE CLUBHOUSE SIZE ON THE ENGINEERING
 PLAN DOES NOT MATCH THE CLUBHOUSE SIZE
 ON THE SITE AND LANDSCAPE PLANS.
  
 2) SHOW DIMENSION LINES FOR ALL DRIVE
 AISLES AND DRIVEWAYS ON THE ENGINEERING
 PLANS.THE GREGORY ROAD ENTRY SCALES AT
 24 FEET WIDE ON THE ENGINEERING PLANS
 AND IS DIMENSIONED AT 22 FEET ON THE
 SITE PLAN.
  
 3) THE APPROVED ELEVATIONS REQUIRE A
 SINGLE GARAGE DOOR FOR EACH INTERIOR
 PARKING SPACE.THE PLANS SUBMITTED FOR
 PLAN REVIEW SHOW DOUBLE GARAGE DOORS.
 THIS NEEDS TO BE CORRECTED.
  
 4) PLEASE SHOW ELEVATION MARK FOR THE
 BUILDINGS ON ALL OF THE ELEVATION
 SHEETS.THE ADDITIONAL ELEVATION MARKS
 SHALL SHOW THE HIGHEST RIDGE HEIGHT AND
 THE HEIGHT TO THE TOP OF THE ROOFTOP
 MECHANICAL ROOM.
  
 5) PLEASE NOTE THAT A RECORDED BOUNDARY
 PLAT IS REQUIRED PRIOR TO THE ISSUANCE
 OF A BUILDING PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.