Plan Review Details - Permit 05091397
Plan Review Stops For Permit 05091397
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-14 Cont ID  
Sent By mjacobs Date 2005-10-14 Time 09:34 Rev Time 2.00
Received By mjacobs Date 2005-10-14 Time 07:39 Sent To PC
Notes
2005-10-14 00:00:00 
  
  
 1)FBC.104.1.1 WHEN REQUIRED. ANY OWNER,
 AUTHORIZED AGENT, OR CONTRACTOR WHO
 DESIRES TO CONSTRUCT, ENLARGE, ALTER,
 REPAIR, MOVE, DEMOLISH, OR CHANGE THE
 OCCUPANCY OR OCCUPANT CONTENT OF A
 BUILDING OR STRUCTURE, SHALL FIRST MAKE
 APPLICATION TO THE BUILDING OFFICIAL AND
 OBTAIN THE REQUIRED PERMIT FOR THE WORK.
  
 2) SUBMIT DRAWINGS OF THE PREVIOUS
 OCCUPANCY ALONG WITH THE PROPOSED
 DRAWINGS, STATING THE USE OF EACH ROOM
 OR AREA. DRAWINGS SHALL INCLUDE
 PLUMBING/MECHANICAL/ELECTRICAL/GAS/AND
 BUILDING DETAILS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 (561)659-8026
 [email protected].

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-10-14 Cont ID  
Sent By dpalmer Date 2005-10-14 Time 11:48 Rev Time 2.00
Received By dpalmer Date 2005-10-14 Time 11:48 Sent To  
Notes
2005-10-14 00:00:00*** UNSAT ***
 PLEASE SEE THE PASSED REDLINE DPLANS
 AHVE NOW BEEN VOIDED.
  
 1)NOTE: PLEASE SEE BLDG REVIEW WITH
 RESPECT TO PERMIT REQUIRED BY A GC ETC
 TO BE PULLED FOR CHANGE IN OCCUPANCY AND
 DEMOLITION WORK DONE WITH OUT PERMITS.
 PLEASE BE SURE PLANS INDICATE ALL
 EXISTING CONDITIONS BEFORE WORK WAS
 DONE. PLEASE KNOW, ORIGINAL PLANS WERE
 PULLED AND VIEWED FOR ALL EXSITING WHICH
 IS NOT INDICATED ON PLANS.
  
 PLEASE KNOW, PERMIT FOR DEMO OF ALL
 PLUMB, MECH, GAS ETC WILL BE REQUIRED IN
 ORDER BE SURE ALL EXISTING EQUIPMENT WAS
 REMOVED, CAPPED OF PROPERLY FOR CODE
 COMPLIANCE.
 PLEASE KNOW, PLUMB REVIEW COMMENTSMAY
 AFFETC DEMO, OF GREASE TRP ETC.
 PLEASE CALL CHEIF PLUMBING INSPECTOR FOR
 WHAT MAY BE NEEDED FOR THIS.
 PLEASE BE SURE TO INDICATE ALL EXISTING,
 WHICH WAS ON PREVIOUS PLANS ON RECORD.
  
 2)NOTE: PLEASE SEE PLANS CAME IN WITH
 ADDRESS OF 541 , WHEN PCNSHOWS 535
 CLEMATIS.
  
 3)NOTE: PLEASE SEE VALUATION IS TO BE
 BASED ON ALL LABOR AND MATERIALS FOR ALL
 WORK IN SCOPE.
 FBC 104.6.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-10-08 Cont ID  
Sent By dpalmer Date 2005-10-08 Time 16:47 Rev Time 0.70
Received By dpalmer Date 2005-10-08 Time 16:46 Sent To  
Notes
2005-10-08 00:00:00****** NOTES REDLINED ***
  
 PASSED PENDING BLDG REVIEW, REVIEW SCOPE
 OF WORK WITH INSPECTORS WHO ISSUED
 "REDTAG"AND POSSIBLE PERMIT REQUIRED
 BY A GC FOR "CHANGE IN OCCUPANCY" FROM
 RESTAURANT TO MERCHANTILE.
 PLEASE KNOW, ALL ELECTRICAL WORK ALREADY
 DONE SHALL BE INSPECTED, THIS INCLUDES
 FLOOR BOXES ETC.
  
 COMPLETE REMODEL DONE WITH OUT PERMITS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date 2005-10-05 Cont ID  
Sent By nmccray Date 2005-10-05 Time 08:56 Rev Time 0.00
Received By nmccray Date 2005-10-05 Time 08:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-29 Cont ID  
Sent By adarroug Date 2005-09-29 Time 10:42 Rev Time 0.00
Received By adarroug Date 2005-09-29 Time 10:42 Sent To  
Notes
2005-09-29 00:00:00TO "BOB"#2