Plan Review Stops For Permit 05091331 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-04-10 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-04-10 |
Time |
13:44 |
Sent To |
|
|
Notes |
2006-04-10 00:00:00 | REV OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-12-14 |
Time |
12:38 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2005-12-14 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-11-21 |
Time |
14:05 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2005-11-21 |
Time |
14:00 |
Sent To |
|
|
Notes |
2005-11-21 00:00:00 | DENIED | | | | 1.SUBMIT PRODUCT APPROVALS FOR | | LINTELS.PRODUCT APPROVALS SUBMITTED | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | APPROVAL ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 3.FBC2305.2.1 DRAFTSTOPPING SHALL BE | | PROVIDED IN WOOD FRAME CONSTRUCTION IN | | FLOOR/CEILING ASSEMBLIES. | | SINGLE FAMILY DWELLINGS.IN | | FLOOR/CEILING ASSEMBLIES SEPARATING | | USEABLE SPACES INTO TWO OR MORE | | APPROXIMATE AREAS WITH NO AREA | | GREATER THAN 500 SQ FT.DRAFTSTOPPING | | SHALL BE PROVIDED PARALLEL TO THE MAIN | | FRAMING MEMBERS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-10-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2005-10-17 |
Time |
08:11 |
Rev Time |
3.25 |
Received By |
alange |
Date |
2005-10-14 |
Time |
10:34 |
Sent To |
|
|
Notes |
2005-10-17 00:00:00 | DENIED | | | | 1.SUBMIT PRODUCT APPROVALS FOR | | LINTELS.PRODUCT APPROVALS SUBMITTED | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | APPROVAL ATTACHED. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 3.FBC2305.2.1 DRAFTSTOPPING SHALL BE | | PROVIDED IN WOOD FRAME CONSTRUCTION IN | | FLOOR/CEILING ASSEMBLIES. | | SINGLE FAMILY DWELLINGS.IN | | FLOOR/CEILING ASSEMBLIES SEPARATING | | USEABLE SPACES INTO TWO OR MORE | | APPROXIMATE AREAS WITH NO AREA | | GREATER THAN 500 SQ FT.DRAFTSTOPPING | | SHALL BE PROVIDED PARALLEL TO THE MAIN | | FRAMING MEMBERS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2006-11-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-11-04 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-11-04 |
Time |
15:22 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2006-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-22 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-22 |
Time |
16:55 |
Sent To |
PC |
|
Notes |
2006-10-22 17:06:59 | **** UNSAT **** | | | | 1) NOTE: PLEASE SEE AHU KW RATING HEAT LOAD HAS BEEN | | INCREASED HOWEVER LOAD CALCUALITONS HAVE NOT BEEN | | UPDATED?? | | PLEASE SEE 220.31. | | PANEL"B". | | | | 2) NOTE: PLEASE SEE A PART OF A PANEL SCHEDULE IS BEING | | SHOWN JUST TO THE RIGHT OF THE LOAD CALCULATIONS, | | HOWEVER ARE NOT ON ANY PARTICULAR PANEL SCHEDULE. | | PLEASE REVISED AND ADJUST PLANS. | | 240.4, 310.16, 408.4. | | | | PLEASE SUBMIT THE ABOVE FOR CORRECTIONS. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER. | | EELCTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-04-04 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-04-04 |
Time |
12:51 |
Sent To |
M |
|
Notes |
2006-04-04 00:00:00 | ********* NOTE **************** | | | | | | PLEASE SEE REDLINED NOTES FROM PREVIOUS | | REVIEW STILL HAVE NOT BEEN CORRECTED. | | PLEASE SEE THESE NOTES WERE REDLINED | | ONCE AGAIN AND IF PLANS GO BACK, PLEASE | | REVISE AT THIS TIME. | | THESE REVISIONS ARE NEED TO BE DONE | | BEFORE ROUGH. | | | | IF ANY OTHER REVISION COME IN WITHOUT | | THESE REDLINES CORRECTED. THE REV'S WILL | | BE "UNSAT". | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-03-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-13 |
Time |
21:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-13 |
Time |
20:46 |
Sent To |
PC |
|
Notes |
2006-03-13 00:00:00 | REDLINED: | | | | CORRELATE POOL PANEL LOAD W/ LOAD SHOWN | | ON PANEL "A". | | | | CORRELATE PANEL CIRCUIT #'S, RISER SHOWS | | 40, PANELS SHOW 42. | | | | THESE ARE TO BE REVISED W/ OTHER | | REVISIONS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-12-07 |
Time |
20:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-12-07 |
Time |
19:27 |
Sent To |
B |
|
Notes |
2005-12-07 00:00:00 | *********** PROVISO/REVISION ********** | | | | PLEASE SEE COMMENTS FROM FIRST TWO | | REVIEWS AND NEW NOTES DUE TO CHANGES IN | | LOADS FOR POOL PANEL. | | | | 1)NOTE: PLEASE CORRELATE A/C LOADS. | | PLEASE SEE PANEL "B", WHICH INDICATES A | | 10KW HEAT STRIP, HOWEVER LOAD | | CALCULATIONS INDICATE 65% LOAD AT | | 9750VA?? | | 9750VA IS NOT 65% OF 10KW. | | 215.5 | | | | 2)NOTE: PLEASE SEE LOAD CALCUALTIONS FOR | | POOL PANEL NOW HAVE BEEN CHANGED AND | | CONTINUOUS LOAD FACTOR OF 125% HAS BEEN | | REMOVED?? | | PLEASE SEE 215.3,230.42 ETC, AND PLEASE | | ADJUST LOAD CALCULATIONS TO INCLUDE ALL | | CONTINUOUS LOADS AT 125%. | | PLEASE ALSO SEE TOTAL KVA LOAD SHOWN ON | | PANEL "B" DOES NOT CORRELATE WITH POOL | | PANEL. | | ONE SHOWS 13,270 AND THE OTHER 14,670? | | | | ** PLEASE MAKE THE ABOVE CORRECTIONS | | ALONG WITH ANY OTHER REVISIONS BEFORE | | ROUGH ELECTRICAL INSPECTION. | | PLANS MUST BE SUBMITTED FOR REVIEW, | | STAMPING AND ON JOBSITE FOR ROUGH. | | | | ONCE AGAIN, IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-17 |
Time |
20:42 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2005-11-17 |
Time |
20:13 |
Sent To |
B |
|
Notes |
2005-11-17 00:00:00 | ******** UNSAT 2ND REVIEW ******* | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW STILL NEED TO BE ADDRESSED AND | | PLEASE SEE NEW NOTES DUE TO CHANGES | | MADE. | | | | 1)NOTE: NOTE #1 OK. | | | | 2)NOTE: NOTE #2 OK, WATER HEATER | | REMOVED, GAS. | | | | 3)NOTE: NOTE #3 NO,PLEASE SEE MIN OCP | | REQUIRED FOR POOL HEAT PUMP TO BE 125%. | | 680.9 | | THIS HAS NOT BEEN CHANGED | | | | 4)NOTE: NOTE #4 NO, PLEASE INDICATE ALL | | CONTINUOUS LOADS AT 125%. (POOL PUMP, | | HEAT PUMP). | | PLEASE SEE 215.3,230.42 ETC. | | PLEASE SEE THE FINAL LOAD CALCULATION | | WAS REVISED HOWEVER NOT OCP, AND LOADS | | FOR INDIVIDUAL UNITS WERE NOT NOTED OR | | CHANGED. | | PLEASE SEE POOL PANEL HAD ALREADY SHOWN | | A LOAD AT 59.45A'S AND NOW LOAD EXCEEDS | | FEED FOR PANEL. | | THIS WAS MENTIONED ON PREVIOUS NOTES TO | | UPDATE FEEDER AND OCP, HOWEVER OCP STILL | | SHOWS A 60A FEED. | | CONDUCTORS WERE CHANGED. | | | | 5)NOTE: NOTE #5 NO, PLEASE SEE LOAD | | SHOWN FOR A/C LOADS ON PANEL "B" LOAD | | CALCUALTIONS STILL DO NOT CORRELATE. | | PLEASE SEE KVA HAS NOW CHANGED TO 10KW | | PLEASE CORRELATE AHU LOADS, | | PLEASE SEE NEW NOTE DUE TO INCREASE IN | | KW RATING. | | | | 6)NOTE: NOTE #6 NO. PLEASE LIST ALL THE | | REQUIRED ARC FAULT PROTECTED CIRCUITS AS | | REQUIRED UNDER THE 2002 NEC. 210.12. | | SD'S,LTS, RECEPTS, FANS ETC ARE ALL | | REQUIRED TO HAVE ARC FAULT PROTECTION. | | | | 7)NOTE: NOTE #7 OK. | | | | 8)NOTE: NOTE #8 OK. | | | | 9)NOTE:NOTE #9 NO, PLEASE SEE 410.8 | | FOR MINCLEARENCE REQUIRED FOR LT IN | | PANTRY. | | PLEASE KNOW, PANTRIES ARE LIKELY TO | | CONTAIN COMBUSTIBLES. | | PLEASE KNOW, IT IS NOTED THAT A NOTE ON | | PLANS NOW MENTIONS LT ABOVE ON CEILING, | | HOWEVER THIS DOES NOT CHANGE THE MIN | | CLEARENCE REQUIREMENTS FOR TYPE OF | | FIXTURE SHOWN. | | CLEARENCES FROM 410.8 GO ALL THE WAY TO | | THE CEILING. | | | | 10)NOTE:NOTE #10 OK. | | | | 11)NOTE: NOTE #11 OK. | | | | NEW NOTES: | | | | 1)NOTE: PLEASE SEE424.3B , NOW THAT KW | | RATING FOR AHU HAS NOW INCREASED TO | | 10KW, THE MIN OCP SHALL BE SIZED @125%. | | PLEASE ALSO ADJUST MIN AWG ONCE OCP HAS | | BEEN INCREASED. | | | | 2)NOTE: PLEASE SEE A NOTICE IS NOW GIVEN | | WITH RESPECT TO THE DESIGN PROFESSIONAL | | AND REPEAT COMMENTS. | | PLEASE SEE COPY OF FS 553.80(2)(B) | | ATTACHED. | | THIS IS ONLY A NOTE GIVEN AT THIS TIME. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | AND ONLY INSERT NEW REVISED SHEETS INTO | | TWO COMPLETE SETS FOR REVIEW AND | | STAMPING. | | ONE COPY OF ANY OLD/VOIDED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | ** PLEASE SEE MOST OF THE ITEMS ABOVE | | HAVE BEEN REDLINED ON ONE SET OF PLANS | | FOR AREAS OF COMMENTS. | | | | ** PLEASE BE SURE TO REMOVE ALL | | OLD/VOIDED SHEETS FROM SETS AND AND ONLY | | INSERT NEW REVISED SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-10-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-06 |
Time |
14:08 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2005-10-06 |
Time |
14:08 |
Sent To |
M |
|
Notes |
2005-10-06 00:00:00 | *********** UNSAT ************ | | | | 1)NOTE: PLEASE MOVESMOKE DETECTOR IN | | MASTER BEDROOM AREA TO BE LOCATED WITH | | THE HIGHEST POINT OF THE CEILING. THIS | | IS REQUIRED TO BE WITH 12" OF THE | | HIGHEST POINT OF A FLAT CEILING. | | NFPA-72 11.8.3.5 | | | | 2)NOTE: PLEASE SEE WATER HEATER #2 AS | | LISTED ON PANEL SCHEDULE "A" COULD NOT | | BE LCOATED ON PLANS. PLEASE SHOW. | | | | 3)NOTE: PLEASE SEE MIN OCP REQUIRED FOR | | POOL HEAT PUMP TO BE 125%. | | 680.9 | | | | 4)NOTE: PLEASE INDICATE ALL CONTINUOUS | | LOADS AT 125%. (POOL PUMP, HEAT PUMP). | | PLEASE SEE 215.3,230.42 ETC. | | PLEASE SEE POOL PANEL ALREADY SHOWS LOAD | | AT 59.45A'S. | | THIS PANEL, FEEDER, OCP ETC WILL BE | | REQUIRED TO BE INCREASED. PLEASE SEE | | PANEL MUST ALSO CONTAIN SPACE FOR FTURE | | LOAD. 90.8 | | PLEASE FOLLOW THROUGH WITH LOAD | | CALCULATIONSON PANEL "B". | | | | 5)NOTE: PLEASE CORRELATE AHU LOADS, | | PLEASE SEE LOAD CALCS FOR PANEL "B" | | SHOWS 6750 @65%?, YET PANEL SHOWS | | 7500VA? | | | | 6)NOTE: PLEASE LIST ALL THE REQUIRED ARC | | FAULT PROTECTED CIRCUITS AS REQUIRED | | UNDER THE 2002 NEC. 210.12. | | SD'S,LTS, RECEPTS, FANS ETC ARE ALL | | REQUIRED TO HAVE ARC FAULT PROTECTION. | | | | 7)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTORS FROM MAINS TO SUB | | PANELS. | | 250.110,250.122 ETC. | | | | 8)NOTE: PLEASE CORRELATE THE NUMBER OF | | RECESSED LT FIXTURES ON PLANS WITH THE | | NUMBER OF FIXTURES INDICATED IN LOAD | | CALCULATIONS. | | 215.5 | | | | 9)NOTE: PLEASE SEE 410.8 FOR MIN | | CLEARENCE REQUIRED FOR LT IN PANTRY. | | PLEASE KNOW, PANTRIES ARE LIKELY TO | | CONTAIN COMBUSTIBLES. | | | | 10)NOTE: PLEASE SEE PLANS APPEAR TO HAVE | | A GFI RECEPT MISSING ALONG KITCHEN | | COUNTERSPACE. | | PLEASE SEE 210.52C1 | | | | 11)NOTE: PLEASE SEE GDO'S ARE SHOWN ON | | PANEL SCHEDULES, HOWEVER THESE RECEPTS | | COULD NOT BE LOCATED ON PLANS. | | | | ** PLEASE SEE MOST OF THE ITEMS ABOVE | | HAVE BEEN REDLINED ON ONE SET OF PLANS | | FOR AREAS OF COMMENTS. | | | | ** PLEASE BE SURE TO REMOVE ALL | | OLD/VOIDED SHEETS FROM SETS AND AND ONLY | | INSERT NEW REVISED SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-06 |
Time |
10:50 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-04-06 |
Time |
10:50 |
Sent To |
B |
|
Notes |
2006-04-06 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT | | APPLICATION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-20 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-20 |
Time |
15:44 |
Sent To |
E |
|
Notes |
2006-10-20 15:45:12 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-03 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-03 |
Time |
16:16 |
Sent To |
E |
|
Notes |
2006-04-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-03-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-29 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-29 |
Time |
12:22 |
Sent To |
Z |
|
Notes |
2006-03-29 00:00:00 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-10 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-10 |
Time |
14:49 |
Sent To |
E |
|
Notes |
2006-03-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-05 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-05 |
Time |
11:21 |
Sent To |
E |
|
Notes |
2005-12-05 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-15 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-15 |
Time |
13:30 |
Sent To |
E |
|
Notes |
2005-11-15 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-05 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-05 |
Time |
17:00 |
Sent To |
E |
|
Notes |
2005-10-05 00:00:00 | TO "SFR" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-29 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-29 |
Time |
10:22 |
Sent To |
Z |
|
Notes |
2005-09-29 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-04-04 |
Time |
13:37 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-04-04 |
Time |
13:36 |
Sent To |
P |
|
Notes |
2006-04-04 00:00:00 | ADDED GAS GRILL WITH HOOD TO BACK | | COVERED PATIO. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2005-10-12 |
Time |
14:41 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2005-10-12 |
Time |
14:41 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-06 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-04-06 |
Time |
10:49 |
Sent To |
B |
|
Notes |
2006-04-06 00:00:00 | NO PLUMBING |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2005-10-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-10-08 |
Time |
13:15 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-10-08 |
Time |
13:15 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-04-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-02 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-02 |
Time |
15:45 |
Sent To |
I |
|
Notes |
2006-04-02 00:00:00 | REVISION TO ADD A SUMMER KITCHEN | | (OUTSIDE PATIO WITHIN THE SETBACK - NO | | STOVE) |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-10-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-10-04 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-10-04 |
Time |
17:03 |
Sent To |
I |
|
Notes |
2005-10-04 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | POOL/SPA/DECK. |
|
|