Plan Review Details - Permit 05091147
Plan Review Stops For Permit 05091147
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-10-21 Cont ID  
Sent By rmcdouga Date 2005-10-21 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2005-10-21 Time 06:45 Sent To  
Notes
2005-10-21 00:00:00BUILDING PROVISO
  
 ALL NEW DOORS SHALL COMPLY WITH FBC
 11-4.13.5 AND 11-4.13.9 FOR
 ACCESSIBILITY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By rmcdouga Date 2005-09-26 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2005-09-26 Time 11:28 Sent To  
Notes
2005-09-26 00:00:00DENIED
  
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC 104.2.1ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN. DRAWINGS SHALL BE DRAWN
 TO SCALE WITH SUFFICIENT CLARITY AND
 DETAIL TO INDICATE THE NATURE AND
 CHARACTER OF THE WORK.PLEASE COMPLY.
  
 3) FBC 104.2.1.3 PLANS ARE REQUIRED TO
 BE DRAWN TO A MINIMUM 1/8" SCALE UPON
 SUBSTANTIAL PAPER OR OTHER ACCEPTABLE
 MEDIUM.
  
 4) FBC 104.2.1.2 PLEASE SPECIFY THE
 FOLLOWING ADDITIONAL DATA ON THE PLANS.
 TYPE OF OCCUPANCY, SPRINKLERED OR
 NON-SPRINKLERED BUILDING, NUMBER OF
 STORIES, LOCATION OF ELEVATORS, LOCATION
 AND RATING OF FIRE AND SMOKE WALLS,
 EXITS, (1004)TRAVEL DISTANCE TO EXITS,
 COMMON PATH OF TRAVEL, TRAVEL DISTANCE
 LIMITATION FOR TWO MEANS OF EGRESS,
 (803.3) MINIMUM INTERIOR CLASSIFICATIONS
 FOR ALL AREAS EFFECTED BY THE NEW
 CONSTRUCTION.
  
 5) PROVIDE INTERIOR WALL SECTIONS FOR
 ALL NEW WALL TYPES.
  
 6) SPECIFY NEW OPENING AND DOOR SIZES
 WHICH MUST COMPLY WITH FLORIDA
 ACCESSIBILITY CODE FBC CHAPTER 11.
  
 7) PROVIDE ELEVATIONS OF THE NEW SERVICE
 COUNTERS WHICH MUST COMPLY WITH
 ACCESSIBILITY. SEE FBC CHAPTER 11.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-11-17 Cont ID  
Sent By dpalmer Date 2005-11-17 Time 12:54 Rev Time 0.30
Received By dpalmer Date 2005-11-17 Time 12:54 Sent To  
Notes
2005-11-17 00:00:00ARCHITECT REMOVEDPA ,
 ONLY AS AN INDIVIDUAL.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-11-09 Cont ID  
Sent By dpalmer Date 2005-11-09 Time 11:48 Rev Time 0.00
Received By dpalmer Date 2005-11-09 Time 11:47 Sent To  
Notes
2005-11-09 00:00:00******** UNSAT ********
  
 1)NOTE: PLEASE SEE PLANS SUBMITTED BY AN
 ARCHITECT.
 PLEASE SEE FS 481.219, FAC 61G1-16.004
 WHICH REQUIRES A CERTIFICATE OF
 AUTHORIZATION # ON TITLE BLOCK.
 STATE ALSO SHOWS P.A.,HOWEVER DBPR
 (DEPARTMENT OF BUSINESS AND PROFESSIONAL
 REGULATION DOES NOT INDICATE A CA #.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-10-03 Cont ID  
Sent By dpalmer Date 2005-10-03 Time 08:06 Rev Time 0.00
Received By dpalmer Date 2005-10-03 Time 08:06 Sent To  
Notes
2005-10-03 00:00:00********* UNSAT *********
  
 1)NOTE: PLEASE INDICATE AND SHOW ANY
 ELECTRICAL IN NEW PROPOSED WALLS AND/OR
 DELETION OF ELECTRICAL IN SCOPE OF WORK.
  
 2)NOTE: PLEASE SHOW CIRCUITING ON PLANS
 AND CORRELATE WITH A PANEL SCHEDULE(S)
 TO BE SUBMITTED. SCOPE OF WORK WILL
 DETERMINE WEATHER OR NOT THIS WILL BE
 NEEDED.
 215.5
  
 3)NOTE: PLEASE SEE FIRE REVIEW COMMENTS,
 FOR EM/EXT LTS. PLEASE SEE 700.12E FOR
 CIRCUITING OF EM/EXT LTS.
  
 4)NOTE: PLEASE SEE FBC 104.2.1 WHICH
 REQUIRES THE PRINTED NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR PLANS/
 DESIGN.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-11-09 Cont ID  
Sent By mwennerg Date 2005-11-09 Time 15:26 Rev Time 0.00
Received By mwennerg Date 2005-11-09 Time 15:26 Sent To  
Notes
2005-11-09 00:00:00******PROVISO******
  
 PLANS SHOW EXIT SIGNS, BUT NOT EXISTING
 EMERGENCY LIGHTING. PLEASE SHOW
 LOCATIONS WHERE REQUIRED PRIOR TO FIRE
 FINAL INSPECTION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By mcarsill Date 2005-09-26 Time 12:32 Rev Time 0.00
Received By mcarsill Date 2005-09-26 Time 12:32 Sent To  
Notes
2005-09-26 00:00:001. PLANS DO NOT INDICATE EXISTING
 EXIT SIGNS OR EMERGENCY LIGHTS.
  
 2. NO WALL DETAILS ILLUSTRATED FOR
 THE DRAWINGS.
  
 3. NO PORTABLE FIRE EXTINGUISHERS SHOWN.
  
 4. PLANS LACK SUFFICIENT DETAIL TO
 PERFORM PROPER REVIEW.
  
 5. SEVERAL NEW DOORS SHOWN BUT NO SIZES
 OR HARDWARE INFORMATION PROVIDED.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
  
 804-4709 PHONE
 804-4774 FAX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-11-17 Cont ID  
Sent By adarroug Date 2005-11-17 Time 10:50 Rev Time 0.00
Received By adarroug Date 2005-11-17 Time 10:50 Sent To  
Notes
2005-11-17 00:00:00TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-10-19 Cont ID  
Sent By adarroug Date 2005-10-19 Time 11:06 Rev Time 0.00
Received By adarroug Date 2005-10-19 Time 11:06 Sent To  
Notes
2005-10-19 00:00:00TO "BOB"#9

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2005-10-03 Time   Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 18:45 Sent To  
Notes
2005-09-23 00:00:00TO "BOB"#16