Plan Review Stops For Permit 05091147 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-10-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-10-21 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-10-21 |
Time |
06:45 |
Sent To |
|
|
Notes |
2005-10-21 00:00:00 | BUILDING PROVISO | | | | ALL NEW DOORS SHALL COMPLY WITH FBC | | 11-4.13.5 AND 11-4.13.9 FOR | | ACCESSIBILITY. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2005-09-26 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2005-09-26 |
Time |
11:28 |
Sent To |
|
|
Notes |
2005-09-26 00:00:00 | DENIED | | | | 1)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) FBC 104.2.1ALL INFORMATION, | | DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME | | AND SIGNATURE OF THE PERSON RESPONSIBLE | | FOR THE DESIGN. DRAWINGS SHALL BE DRAWN | | TO SCALE WITH SUFFICIENT CLARITY AND | | DETAIL TO INDICATE THE NATURE AND | | CHARACTER OF THE WORK.PLEASE COMPLY. | | | | 3) FBC 104.2.1.3 PLANS ARE REQUIRED TO | | BE DRAWN TO A MINIMUM 1/8" SCALE UPON | | SUBSTANTIAL PAPER OR OTHER ACCEPTABLE | | MEDIUM. | | | | 4) FBC 104.2.1.2 PLEASE SPECIFY THE | | FOLLOWING ADDITIONAL DATA ON THE PLANS. | | TYPE OF OCCUPANCY, SPRINKLERED OR | | NON-SPRINKLERED BUILDING, NUMBER OF | | STORIES, LOCATION OF ELEVATORS, LOCATION | | AND RATING OF FIRE AND SMOKE WALLS, | | EXITS, (1004)TRAVEL DISTANCE TO EXITS, | | COMMON PATH OF TRAVEL, TRAVEL DISTANCE | | LIMITATION FOR TWO MEANS OF EGRESS, | | (803.3) MINIMUM INTERIOR CLASSIFICATIONS | | FOR ALL AREAS EFFECTED BY THE NEW | | CONSTRUCTION. | | | | 5) PROVIDE INTERIOR WALL SECTIONS FOR | | ALL NEW WALL TYPES. | | | | 6) SPECIFY NEW OPENING AND DOOR SIZES | | WHICH MUST COMPLY WITH FLORIDA | | ACCESSIBILITY CODE FBC CHAPTER 11. | | | | 7) PROVIDE ELEVATIONS OF THE NEW SERVICE | | COUNTERS WHICH MUST COMPLY WITH | | ACCESSIBILITY. SEE FBC CHAPTER 11. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-17 |
Time |
12:54 |
Rev Time |
0.30 |
Received By |
dpalmer |
Date |
2005-11-17 |
Time |
12:54 |
Sent To |
|
|
Notes |
2005-11-17 00:00:00 | ARCHITECT REMOVEDPA , | | ONLY AS AN INDIVIDUAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-09 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-11-09 |
Time |
11:47 |
Sent To |
|
|
Notes |
2005-11-09 00:00:00 | ******** UNSAT ******** | | | | 1)NOTE: PLEASE SEE PLANS SUBMITTED BY AN | | ARCHITECT. | | PLEASE SEE FS 481.219, FAC 61G1-16.004 | | WHICH REQUIRES A CERTIFICATE OF | | AUTHORIZATION # ON TITLE BLOCK. | | STATE ALSO SHOWS P.A.,HOWEVER DBPR | | (DEPARTMENT OF BUSINESS AND PROFESSIONAL | | REGULATION DOES NOT INDICATE A CA #. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-10-03 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2005-10-03 |
Time |
08:06 |
Sent To |
|
|
Notes |
2005-10-03 00:00:00 | ********* UNSAT ********* | | | | 1)NOTE: PLEASE INDICATE AND SHOW ANY | | ELECTRICAL IN NEW PROPOSED WALLS AND/OR | | DELETION OF ELECTRICAL IN SCOPE OF WORK. | | | | 2)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | AND CORRELATE WITH A PANEL SCHEDULE(S) | | TO BE SUBMITTED. SCOPE OF WORK WILL | | DETERMINE WEATHER OR NOT THIS WILL BE | | NEEDED. | | 215.5 | | | | 3)NOTE: PLEASE SEE FIRE REVIEW COMMENTS, | | FOR EM/EXT LTS. PLEASE SEE 700.12E FOR | | CIRCUITING OF EM/EXT LTS. | | | | 4)NOTE: PLEASE SEE FBC 104.2.1 WHICH | | REQUIRES THE PRINTED NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR PLANS/ | | DESIGN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-11-09 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-11-09 |
Time |
15:26 |
Sent To |
|
|
Notes |
2005-11-09 00:00:00 | ******PROVISO****** | | | | PLANS SHOW EXIT SIGNS, BUT NOT EXISTING | | EMERGENCY LIGHTING. PLEASE SHOW | | LOCATIONS WHERE REQUIRED PRIOR TO FIRE | | FINAL INSPECTION. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-09-26 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2005-09-26 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2005-09-26 |
Time |
12:32 |
Sent To |
|
|
Notes |
2005-09-26 00:00:00 | 1. PLANS DO NOT INDICATE EXISTING | | EXIT SIGNS OR EMERGENCY LIGHTS. | | | | 2. NO WALL DETAILS ILLUSTRATED FOR | | THE DRAWINGS. | | | | 3. NO PORTABLE FIRE EXTINGUISHERS SHOWN. | | | | 4. PLANS LACK SUFFICIENT DETAIL TO | | PERFORM PROPER REVIEW. | | | | 5. SEVERAL NEW DOORS SHOWN BUT NO SIZES | | OR HARDWARE INFORMATION PROVIDED. | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | OFFICER | | | | 804-4709 PHONE | | 804-4774 FAX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-17 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-17 |
Time |
10:50 |
Sent To |
|
|
Notes |
2005-11-17 00:00:00 | TO "BOB"#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-10-19 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-10-19 |
Time |
11:06 |
Sent To |
|
|
Notes |
2005-10-19 00:00:00 | TO "BOB"#9 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2005-10-03 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-23 |
Time |
18:45 |
Sent To |
|
|
Notes |
2005-09-23 00:00:00 | TO "BOB"#16 |
|
|