Plan Review Details - Permit 05090899
Plan Review Stops For Permit 05090899
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-17 Cont ID  
Sent By alange Date 2005-10-17 Time 07:30 Rev Time 2.66
Received By alange Date 2005-10-17 Time 07:25 Sent To  
Notes
2005-10-17 00:00:00DENIED
  
 1.SHOW SIZE AND TYPE OF BEDROOM WINDOW
 INCLUDING SILL HEIGHT FROM FLOOR.FBC
 1005.4
  
 2.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR LINTELS.ALL PRODUCT
 APROVALS REQUIRE THE FOLLOWING STATE
 PRODUCT APPROVAL.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.PERSON RESPONSIBLE FOR THE PLAN
 DESIGN SHALL HAVE PRINTED NAME AND
 SIGNATURE ON PLANS. FBC 104.2.1
  
 ANY QUESTIONS CALL ME
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-10-08 Cont ID  
Sent By dpalmer Date 2005-10-08 Time 15:34 Rev Time 0.50
Received By dpalmer Date 2005-10-08 Time 15:29 Sent To P
Notes
2005-10-08 00:00:00******** UNSAT **********
  
 1)NOTE: PLEASE SEE TWO INDIVIDUAL TH
 UNITS ARE BEING CONVERTED INTO ONE.
 PLEASE SEE ELECTRICAL SERVICE SHALL
 CONTAIN ONLY ONE MAIN AND ONE SERVICE.
 PLEASE SUBMIT RISER DIAGRAM WITH REVISED
 ELECTRICAL FOR NEW WORK TO BE DONE.
 230.2.
  
  
 2)NOTE: PLEASE SEE RECEPTS AT KITCHEN
 COUNTERSPACE, BATH RM AND GARAGE ARE ALL
 TO BE GFI / GFI PROTECTED.
 210.8A6,210.8A1, 210.8A2
  
 3)NOTE: PLEASE PROVIDE A REVISED PANEL
 SCHEDULE FOR NEW ELECTRICAL WORK.
 WASHER, DRYER, DEDICATED BRANCH CIRCUITS
 REQUIRED UNDER 210.52D, 210.52B1,
 210.11C1,C3 ETC.
 215.5
  
 4)NOTE: PLEASE PROVIDE ALL ROOM/AREA
 DESIGNATIONS ON PLANS.
 PLEASE ALSO IDENTIFY FLRS.
 215.5
  
 5)NOTE: PLEASE SEE WATER HEATER SHOWN
 MAY NOT BE LOCATED IN A CLOSET
 CONTAINING COMBUSTIBLES. 422.17
  
 6)NOTE: PLANS SHALL CONTAIN THE PRINTED
 NAME AND THE SIGNATURE OF THE PERSON
 RESPONSIBLE FOR PLANS/DESIGN.
 FBC 104.2.1, CITY WIDE ADMINISTRATIVE
 CODE.
  
 7)NOTE: PLEASE SEE SWITCHES CONTROLING
 LITGHTING ETC FROM TWO OR MORE LOCATIONS
 ARE 3-WAY SWITCHES. PLEASE SEE MISPRINT
 ON PLANS WHICH INDICATE A SWITCH WITH 2?
 AND LISTED ON SYMBOL SCHEDULE AS 2-WAY?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 13:22 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 13:22 Sent To E
Notes
2005-09-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-23 Cont ID  
Sent By adarroug Date 2005-09-23 Time 13:49 Rev Time 0.00
Received By adarroug Date 2005-09-23 Time 13:49 Sent To B
Notes
2005-09-23 00:00:00TO "LMARTINEZ" DESK/SUBMITTAL
 RECORDED UNITY OF TITLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-10-17 Cont ID  
Sent By alange Date 2005-10-17 Time 07:31 Rev Time 0.00
Received By alange Date 2005-09-21 Time 16:06 Sent To  
Notes
2005-09-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-10-13 Cont ID  
Sent By tgordon Date 2005-10-13 Time 08:13 Rev Time 0.15
Received By tgordon Date 2005-10-13 Time 08:13 Sent To B
Notes
2005-10-13 00:00:00NO MECH. PLANS OR MECH. CONTRACTOR
 SUBMITTED AT THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-10-12 Cont ID  
Sent By jleech Date 2005-10-12 Time 14:40 Rev Time 0.50
Received By jleech Date 2005-10-12 Time 14:40 Sent To M
Notes
2005-10-12 00:00:00DENIED;
 SANITARY RISER DIAGRAMREQUIRED. SHOW HOW
 FIXTURES BEING MOVED ARE CONNECTED TO
 THE PLUMBING SYSTEM. SHOW HOW DELETED
 PIPING IS DISCONNECTED, MUST COMPLY WITH
 FBC-2001 PLUMBING SEC. 704.5, NO DEAD
 ENDS LONGER THAN 2'.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-09-26 Cont ID  
Sent By jroach Date 2005-09-26 Time 14:33 Rev Time 0.00
Received By jroach Date 2005-09-26 Time 14:33 Sent To  
Notes
***NONE***