Plan Review Details - Permit 05090863
Plan Review Stops For Permit 05090863
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2005-09-21 Cont ID  
Sent By jhiggins Date 2005-09-21 Time 10:09 Rev Time 0.00
Received By jhiggins Date 2005-09-21 Time 10:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-01-02 Cont ID  
Sent By shill Date 2007-01-02 Time 10:29 Rev Time 0.00
Received By shill Date 2007-01-02 Time 10:29 Sent To Z
Notes
2007-01-02 10:30:09PROVISO - SUBMIT WINDOW PRODUCT APPROVALS REVIEWED BY
 DESIGNER OF RECORD

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-12-04 Cont ID  
Sent By shill Date 2006-12-04 Time 15:16 Rev Time 0.00
Received By shill Date 2006-12-04 Time 15:16 Sent To  
Notes
2006-12-04 15:26:02****CORRECTIONS****
 ****NOTE - CODE CHANGED FROM FBC2001 TO FBC2004****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB
 FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 FROM PREVIOUS LIST:
  
 2.)THE GARAGE ELEVATIONS ARE LABELED AS FRONT, BACK,
 LEFT, RIGHT AND DO NOT MATCH THE SITE PLAN (THE FRONT
 SHOWN ON THE ELEVATION IS A SHORT SIDE, ON THE SITE
 PLAN IS A LONG SIDE).THIS CHANGE MAY BE DONE IN INK
 ON THIS SHEET BY THE ARCHITECT; MUST BE INITIALLED AND
 DATED (NEW SHEETS NOT REQUIRED).
  
 3.)SHOW THE DIMENSION BETWEEN THE HOUSE AND THE
 GARAGE; SEE NEXT COMMENT.
  
 4.)ZONING HAS PROVISO'D THAT THE PROPOSED PORCH IS 6'
 FROM THE PROPOSED GARAGE.ON THE SURVEY, IT IS LESS
 THAN 6'.PLEASE ADDRESS.
  
 NEW COMMENT:
  
 5.)NEW ENERGY CALCS REQUIRED AS THE OLD ENERGY CALCS
 ARE FOR FBC2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-11-15 Cont ID  
Sent By shill Date 2006-11-15 Time 15:13 Rev Time 0.00
Received By shill Date 2006-11-15 Time 12:23 Sent To  
Notes
2006-11-15 15:16:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2001
  
 1.)THE PROPOSED GARAGE IS 5' FROM THE PROPERTY LINE,
 NO OPENINGS ALLOWED FBC TABLE 600.
  
 2.)THE GARAGE ELEVATIONS ARE LABELED AS FRONT, BACK,
 LEFT, RIGHT AND DO NOT MATCH THE SITE PLAN (THE FRONT
 SHOWN ON THE ELEVATION IS A SHORT SIDE, ON THE SITE
 PLAN IS A LONG SIDE).
  
 3.)SHOW THE DIMENSION BETWEEN THE HOUSE AND THE
 GARAGE SO THAT COMPLIANCE WITH FBC TABLE 600 CAN BE
 DETERMINED.
  
 4.)ZONING HAS PROVISO'D THAT THE PROPOSED PORCH IS 6'
 FROM THE PROPOSED GARAGE.ON THE SURVEY, IT IS LESS
 THAN 6'.PLEASE ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-09-01 Cont ID  
Sent By shill Date 2006-09-01 Time 10:24 Rev Time 0.00
Received By shill Date 2006-09-01 Time 10:24 Sent To  
Notes
2006-09-01 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)THE REVISION STATES THAT THIS IS TO
 ADD A CARPORT AND GARAGE, BUT OTHER
 SHEETS SUBMITTED.NOTHING CLOUDED
 EXCEPT FOR THE DETAIL LABEL.CLEARLY
 INDICATE ALL CHANGES.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 12:21 Rev Time 0.00
Received By shill Date 2006-01-09 Time 12:21 Sent To  
Notes
2006-01-09 00:00:00SEE MASTER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-04 Cont ID  
Sent By shill Date 2005-10-04 Time 11:24 Rev Time 0.50
Received By shill Date 2005-10-04 Time 11:24 Sent To PC
Notes
2005-10-04 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)ALL INFORMATION REQUIRED BY
 FAC61G15-23.002 IS TO BE ON THE SOILS
 REPORT (CA NUMBER).
  
 2.)THE SOILS REPORT IS FOR A ONE STORY
 STRUCTURE.
  
 3.)SHEET 3.1 DOES NOT MATCH THE
 MASTER.NOTES WERE ADDED ON THE NEW
 SHEET PREPARED BY WILLIAM GENZ, PE WHICH
 ARE NOT ON THE MASTER, SEE FLOOR FRAMING
 PLAN, ALTHOUGH THE REVISION NUMBER HAS
 REMAINED THE SAME.THE PLANS SUBMITTED
 TO BE ISSUED FROM A MASTER ARE TO
 EXACTLY MATCH THE MASTER.ANY TIME THAT
 REVISIONS ARE MADE TO ANY PLAN, THE
 DESIGNER IS TO CLEARLY INDICATE ALL
 CHANGES.FOR THE ENGINEER TO MAKE
 REVISIONS WHICH ARE NOT MARKED,
 REPRESENTING THEM AS THE SAME REVISION
 NUMBER AS A PREVIOUSLY APPROVED PLAN,
 DELAYS REVIEW TIME.PLEASE NOTE THAT
 DISCREPANCIES SUCH AS THIS ONE WILL
 RESULT IN THE PLANS BEING ROUTED THROUGH
 ALL TRADES TO ENSURE THAT OTHER CHANGES
 WERE NOT MADE.
  
 4.)SHEET 5.1 DOES NOT MATCH THE
 MASTER.THE REVISION NUMBERS AND DATES
 ARE NOT THE SAME AS ON THE MASTER.
  
 5.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 6.)PLANS ISSUED FROM A MASTER ARE
 REQUIRED TO INCLUDE ONLY THE FOLLOWING
 SHEETS:FLOOR PLAN (SHEET 4.1) AND
 ELEVATIONS (6.1).
  
 7.)ADDITIONAL FEES DUE (VALUATION
 ADJUSTMENT), SEE ATTACHED BILL.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-30 Cont ID  
Sent By dpalmer Date 2006-11-30 Time 11:55 Rev Time 0.00
Received By dpalmer Date 2006-11-30 Time 11:55 Sent To M
Notes
2006-11-30 11:56:54REDLINED, THIS MODEL DOES NOT GET A GDO.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-10-29 Cont ID  
Sent By dpalmer Date 2006-10-29 Time 09:23 Rev Time 0.00
Received By dpalmer Date 2006-10-29 Time 09:21 Sent To M
Notes
2006-10-29 09:27:57 
  
 ***UNSAT ***
  
 1) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO THE
 DETACHED GARAGE, DISCONNECTING MEANS, GROUNDING
 ELECTRODE SYSTEM, CIRCUITS ON PANEL SCHEDULE ETC.
 225.31, 250.32 ETC,
 408.4, 310.16 ETC.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 11:12 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 11:11 Sent To M
Notes
2006-08-05 00:00:00**********UNSAT ***********
  
 1) NOTE: PLEASE CLARIFY UNDERGROUND
 SEC'S TO FPL. IF THESE ARE INSTALLED BY
 FPL , THEN PLEASE DO NOT INDICATE THE
 CONDUCTOR SIZES, AS THESE WILL NOT
 CORRELATE WITH FPL.
 PLEASE ALSO VERIFY THE DOWNSIZING OF THE
 NEURTRAL CONDUCTOR TO A #3.
 PLEASE PROVIDE NEUTRAL LOAD CALCULATION
 OR FULL SIZE NEUTRAL.
 220.22, 310.15B6
  
 2) NOTE: PLEASE SHOW CONDUIT SIZE FOR
 THE UNDERGROUND AND ALSO THE CONDUIT TO
 INSIDE PANEL. UNABLE TO VERIFY AT THIS
 TIME.
 FBC 106.1.2
  
 3) NOTE: PLEASE SEE 210.52C1AS THERE
 ARE SOME RECEPTS MISSING . SEE REDLINED
 PLANS.
 PLEASE SEE AREAS OF COUNTER SPACE,
 PLEASE SEE LOCATED NEXT TO STOVE ETC.
  
 4) NOTE: PLEASE SEE MISSING ISLAND
 GFI RECEPT. 210.52C1-5,210.8A6
  
 5) NOTE: PLEASE SEE THAT ALL ROOM AND
 AREA DESIGNATIONS ON PLANS CORRELATE
 WITH THE PANEL SCHEDULE.
 PLEASE SEE THAT ALL CIRCUITS ON PANEL
 SCHEDULE SHALL BE SPECIFIC TO ROOMS AND
 AREAS.
 IE; LIVING RM RECEPTS, BEDRM #2
 LTS/RECEPTS, HALL LTS ETC ETC.
 408.4 FBC 106.1.2
 **IT IS KNOWN THAT CIRCUITING DURING
 CONSTRUCTION WILL CHANGE AND THIS CAN EB
 REVISED AT A LATER DATE.
  
 6) NOTE: PLEASE SEE ONLY TWO CIRCUITS
 ARE BEIGN SHOWNWITH ARC FAULT
 PROTECTION FOR ALL BEDRMS LTS, RECEPTS
 AND SD'S. PLEASE KNOW, THE CODE HAS
 CHANGED FROM PREVIOUSLY SUBMITTED PLANS
 UNDER THIS PROJECT TO REQUIRE ARC FAULT
 PROTECTION FOR ALL OUTLETS IN BEDRMS.
 PLEASE BE SURE TO REVISE AS THE LOAD ON
 THESE ONLY TWO CIRCUITS SEEM TO EXCEED
 RATINGS.
 210.12B(2002) NEC. 210.52,220
  
 7)NOTE: PLEASE SEE MISSING THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S).
 210.11C3, SHALL BE 20A AND #12.
 NO BATH(S) LISTED.
  
 8) NOTE: PLEASE BE SURE HE PLANS PROVIDE
 THE FOLLOWING MINIMUM CODES AS ADOPTED
 FOR DESIGN AND FS/FBC 2004
 2002 NFPA-70, 2002 NFPA-72, 2003
 NFPA-101.
  
 9) NOTE: PLEASE SEE PLANS INDICATE THE
 PANEL LOCATED INHALL ON PLANS AND
 PANEL SCHEDULE SAY HALL/UTILITY.??
 PLEASE SEE ELECTRICAL PLANS DO NOT SHOW
 THE SAME WALL AS SHOWN ON BUILDING
 PLANS.
 PLEASE ALSO CLARIFY THE MISSING CONTROL
 FOR LT(S) IN THE UTILITY RM. 210.70
  
 10) NOTE: PLEASE SEE "J-BOXES" SHOWN ON
 PLANS NEED TO BE NOTED FOR "FUTURE FAN
 BOXES' IF INDEED FOR FANS. PLEASE SEE
 314.47D
  
 11) NOTE: PLEASE SEE PLANS DO NOT SHOWN
 LOCATION OF SERVICE ON THE OUTSIDE OF
 HOUSE.
 106.1.2
  
 12) NOTE: PLEASE SEE SURVEY PROVIDED IN
 PACKAGE IS REQUIRED TO CONTAIN AN
 ORIGINAL SIAGNAURE IN ORDER FOR SURVEY
 TO BE VALID. PLEASE SEE FAC 61G15-17, FS
 472.025
  
 13) NOTE: PLEASE SEE MISSING THE DINING
 ROOM CIRCUITS ON ONE OR MORE OF THE SM
 APPL CIRCUITS. 210.11C1,220.16
  
 14) NOTE: PLEASE SEE DISHWASHER AND
 DISPOSAL SEEM TO BE SHARED TO THE SAME
 RECEPT, HOWEVER PLEASE SEE PANEL DOES
 NOT INDICATE A 2-POLE BREAKER. PLEASE
 SEE 210.4B
  
 15) NOTE: PLEASE SEE MISSING DISCONNECT
 AND GROUNDING AT THE DETACHED BLDG.
 PLEASE SHOW ON ELECTRICAL PLANS.
 PLEASE REVISE PANEL SCHEDULES AND LOAD
 CALCS.
 PLEASE SEE 225.31-225.39, 250.32
  
 ** IMPORTANT **
 BEFORE RESUBMITTING PLANS ONCE ALL
 REVIEWS ARE COMPLETED. PLEASE BE SURE TO
 COMPLETELY REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 ONLY ONE COPY OF THE OLD SHEETS SHOULD
 BE SUBMITTED FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By dpalmer Date 2006-02-06 Time 07:38 Rev Time 0.00
Received By dpalmer Date 2006-02-06 Time 07:34 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 12:20 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 10:12 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 10:12 Sent To P
Notes
2007-08-03 10:12:44TO "JLEECH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-01-02 Cont ID  
Sent By shill Date 2007-01-02 Time 09:57 Rev Time 0.00
Received By shill Date 2007-01-02 Time 09:57 Sent To Z
Notes
2007-01-02 09:57:51TO ZONING IN BOX
 SITE PLAN CHANGED

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-12-15 Cont ID  
Sent By adarroug Date 2006-12-15 Time 11:40 Rev Time 0.00
Received By adarroug Date 2006-12-15 Time 11:40 Sent To B
Notes
2006-12-15 11:40:28TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-11-29 Cont ID  
Sent By spalmer Date 2006-11-29 Time 19:10 Rev Time 0.00
Received By spalmer Date 2006-11-29 Time 19:10 Sent To E
Notes
2006-11-29 19:11:04REV/TO DPALMER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-10-28 Cont ID  
Sent By adarroug Date 2006-10-28 Time 15:03 Rev Time 0.00
Received By adarroug Date 2006-10-28 Time 15:03 Sent To E
Notes
2006-10-28 15:04:14TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-10-23 Cont ID  
Sent By adarroug Date 2006-10-23 Time 14:15 Rev Time 0.00
Received By adarroug Date 2006-10-23 Time 14:15 Sent To Z
Notes
2006-10-23 14:15:31TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 11:22 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 11:22 Sent To E
Notes
2006-08-05 00:00:00TO DP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 09:52 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 09:52 Sent To Z
Notes
2006-08-01 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 09:09 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 09:09 Sent To E
Notes
2006-01-30 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-06 Cont ID  
Sent By adarroug Date 2006-01-06 Time 08:57 Rev Time 0.00
Received By adarroug Date 2006-01-06 Time 08:57 Sent To B
Notes
2006-01-06 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-27 Cont ID  
Sent By adarroug Date 2005-12-27 Time 16:12 Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 16:12 Sent To Z
Notes
2005-12-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 14:26 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 14:25 Sent To B
Notes
2005-09-27 00:00:00TO "SHILL" DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-04 Cont ID  
Sent By shill Date 2005-10-04 Time 12:21 Rev Time 0.00
Received By shill Date 2005-09-21 Time 14:07 Sent To  
Notes
2005-09-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-12-01 Cont ID  
Sent By tgordon Date 2006-12-01 Time 08:17 Rev Time 0.35
Received By tgordon Date 2006-12-01 Time 08:17 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-10-30 Cont ID  
Sent By tgordon Date 2006-10-30 Time 11:46 Rev Time 0.20
Received By tgordon Date 2006-10-30 Time 11:46 Sent To P
Notes
2006-10-30 11:47:03*** DENIED ***
 1) 8"RETURN AIR TRANSFER DUCT TO BEDROOM #1 IS TO
 SMALL, SEE NOTE #3 (A).
  
 2) 9"RETURN AIR TRANSFER DUCT TO MASTER SUITE IS TO
 SMALL, SEE NOTE #3 (A) AND (C) EXCEPT.
  
 3) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-08-07 Cont ID  
Sent By tgordon Date 2006-08-07 Time 10:51 Rev Time 0.50
Received By tgordon Date 2006-08-07 Time 10:51 Sent To P
Notes
2006-08-07 00:00:00*** DENIED ***
 1) JOB ADDRESS MUST APPEAR ON ALL PAGES
 OF PLANS.
  
 2) MECHANICAL PLANS EQUIPMENT LIST SHOWS
 AHU IS A 10 SEER AND CONDENSER UNIT IS A
 12 SEER, PLEASE SHOW THE SEER OF THE
 SYSTEM ONLY. AND SHOW THE TOTAL BTU'S.
 AND SENSIBLE BTU'S. OF THE A/C SYSTEM.
  
 3) PLEASE SHOW ON MECH. PLANS THE SIZE
 OF THE RETURN AIR GRILL TO THE AIR
 HANDLER.
  
 4) RETURN AIR TRANSFER DUCTS TO
 BEDROOMS, THE GRILLS ARE TO SMALL FOR
 THE DUCTS.
  
 5) SUPPLY AIR DUCT TO SECOND FLOOR
 CLOSET #2 NEEDS TO BE SIZED.
  
 6) PLEASE EXPLAIN WHY A 7" SUPPLY AIR
 DUCT IS GOING TO THE SMALL CLOSET IN THE
 HALL.
  
 7) PLEASE SUBMIT MANUAL D CALCULATIONS
 FOR RESIDENTIAL DUCT DESIGN, PER 2004
 FBC/R M1601.1 AND FBC 13-610.1.ABC.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 12:20 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-08-07 Cont ID  
Sent By jleech Date 2007-08-07 Time 08:04 Rev Time 0.00
Received By jleech Date 2007-08-07 Time 08:04 Sent To  
Notes
2007-08-07 08:04:36REVISED RISER DIAGRAM OK

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-11-06 Cont ID  
Sent By jleech Date 2006-11-06 Time 11:37 Rev Time 0.00
Received By jleech Date 2006-11-06 Time 11:37 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-08-18 Cont ID  
Sent By jleech Date 2006-08-18 Time 07:40 Rev Time 0.00
Received By jleech Date 2006-08-18 Time 07:40 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 12:20 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 2007-01-11 Cont ID  
Sent By mmclean Date 2007-01-11 Time 14:16 Rev Time 0.00
Received By mmclean Date 2007-01-11 Time 14:16 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2006-10-27 Cont ID  
Sent By mmclean Date 2006-10-27 Time 17:28 Rev Time 0.00
Received By mmclean Date 2006-10-27 Time 17:28 Sent To I
Notes
2006-10-27 17:28:47PROVISO: THE PROPOSED DETACHED GARAGE MUST BE 6FT FROM
 THE PROPOSED COVERED REAR PORCH.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-08-03 Cont ID  
Sent By mmclean Date 2006-08-03 Time 15:30 Rev Time 0.00
Received By mmclean Date 2006-08-03 Time 15:30 Sent To I
Notes
2006-08-03 00:00:00REVISION - ADD DETACHED ONE CAR GARAGE
 AND COVERED.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-05 Cont ID  
Sent By mmclean Date 2006-01-05 Time 11:29 Rev Time 0.00
Received By mmclean Date 2006-01-05 Time 11:29 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By mmclean Date 2005-09-26 Time 18:43 Rev Time 0.00
Received By mmclean Date 2005-09-26 Time 18:43 Sent To I
Notes
2005-09-26 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK.
  
 NOTE: MUST MAINTAIN 1000SQ FT FOR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
 2. MUST PROVIDE THE SETBACK OF THE
 PROPOSED STRUCTURE (FRONT/SIDE/REAR)
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved