Plan Review Details - Permit 05090826
Plan Review Stops For Permit 05090826
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-03-19 Cont ID  
Sent By jgomez Date 2007-03-19 Time 10:11 Rev Time 2.00
Received By jgomez Date 2007-03-19 Time 07:41 Sent To PC
Notes
2007-03-19 12:37:23BUILDING REVIEW PROVISO:
 1- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS
 UNDER A SEPARATE PERMIT. INCLUDE COMPLETE STORM
 SHUTTERS INSTALLATION SCHEDULE. SEE ATTACHED SAMPLE.
  
 2- PROVIDE PRODUCT APPROVAL FOR 8'-0" WIDE SLIDING
 GLASS DOORS AS SHOWN ON PLANS. TWO COPIES. ARCHITECT TO
 REVIEW PRODUCT APPROVAL PRIOR TO SUBMITTAL.
  
 3- ARCHITECT TO REVIEW AND APPROVE IN WRITING PRODUCT
 APPROVALFOR ROOF SHINGLES AS REQUIRED BY SEC. 108.3
 CITY AMENDMENTS TO FBC 2004.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2007-03-02 Cont ID  
Sent By jgomez Date 2007-03-02 Time 17:16 Rev Time 0.00
Received By jgomez Date 2007-03-02 Time 17:16 Sent To  
Notes
2007-03-02 19:03:50BUILDING REVISION THIRD CHECKLIST:
 1- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS IF
 WORK IS NOT STARTED. NEED RE-RECORDED NOTICE OF
 COMMENCEMENT.
  
 2- BRING DRAWINGS TO PALM BEACH COUNTY FOR IMPACT FEES
 REVISION. BRING BACK STAMPED DRAWINGS AND PAID RECEIPT
 IF ADDITIONAL FEES ARE DUE.
  
 3- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
  
 4- OWES $788.35 FOR UPDATED PERMIT VALUATION AND RADON
 FEES.
 ***NOTE: FEES TO BE PAID AT TIME OF NEXT SUBMITTAL.
 PLAN REVIEW WILL NOT BE DONE UNTILALL FEES ARE PAID.
  
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) IMPACT SLIDING GLASS DOORS AS SPECIFIED ON
 ARCHITECT'S PLANS.
  
 6- ARCHITECT TO PROVIDE THE FIRM LICENSE NUMBER AS
 REQUIRED BY SEC. 61G1-16.004 OF FLORIDA ADMINISTRATIVE
 CODE.
  
 7- CLARIFY WHY IS ARCHITECT APPROVING PRODUCT APPROVAL
 FOR 4", 6" AND 12" CONCRETE LINTELS IF THERE ARE NO
 SUCH TYPE OF LINTELS SPECIFIED ON PLANS.
  
 8- NEED TO ADDRESS ELECTRICAL COMMENTS ALSO. ***NOTE:
 WHEN RE-SUBMITTING MAKE SURE PROPER PLAN REVIEW TRADES
 ARE INDICATED ON THE RE-SUBMITTTAL FORM TO EXPEDITE THE
 REVIEW PROCESS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-01-22 Cont ID  
Sent By jgomez Date 2007-01-22 Time 13:43 Rev Time 0.00
Received By jgomez Date 2007-01-22 Time 07:44 Sent To  
Notes
2007-01-22 14:04:37BUILDING REVISION SECOND CHECKLIST (REVISION DONE UNDER
 FBC 2004 AS SPECIFIED ON PLANS):
 1- TRUSS DRAWINGS WILL BE REQUIRED FOR REVIEW PRIOR TO
 INSTALLATION. SEE SEC. R802.10 FOR REQUIRED
 INFORMATION. DESIGNER OF RECORD TO REVIEW AND APPROVE
 THEM PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 2- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF
 BEING RECORDED IF WORK IS NOT STARTED. SEC. 713.13(2)
 FLORIDA STATUTES. NEED RE-RECORDED NOTICE OF
 COMMENCEMENT.
  
 3- A) REVISE THE ENERGY CALCULATIONS. OVERHANG LENGTH
 AND OVERHANG HEIGHT ARE INCORRECT.
  
 B) COMPLETE ALL INFORMATION ON TOP OF FORM.
  
 4- BRING DRAWINGS TO PALM BEACH COUNTY FOR IMPACT FEES
 REVISION. BRING BACK STAMPED DRAWINGS AND PAID RECEIPT
 IF ADDITIONAL FEES ARE DUE.
  
 5- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS
 UNDER A SEPARATE PERMIT AS AGREED ON AT TIME OF
 ORIGINAL PERMIT APPLICATION APPROVAL.
  
 6- OWES $788.35ADDITIONAL FEES FOR UPDATED BUILDING
 VALUATION,RADON FEES AND REVISION FEES..
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) INSWING ENTRY DOOR AS SHOWN ON PLANS.
 B) IMPACT SLIDING GLASS DOORS AS SPECIFIED ON
 PLANS.
 C) PRECAST CONCRETE LINTELS AS SPECIFIED ON PLANS.
 D) ALL SIMPSON OR USP CONNECTORS SPECIFIED ON
 FRAMING PLANS AND DETAILS. PROVIDE ONLY THE FLORIDA
 PRODUCT APPROVAL COVER PAGE AND THE SPECIFIC PAGE
 SHOWING THE CONNECTOR.
 E) SINGLE HUNG WINDOWS.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITTING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 PRODUCT APPROVAL FOR TIBERLINE SHINGLES IS MISSING THE
 ARCHITECT'S SIGNATURE.
  
 9- ARCHITECT TO PROVIDE ALL HIS INFORMATION AND FIRM'S
 INFORMATION AS REQUIRED BY SEC. 61G1-16.004 OF FLORIDA
 ADMINISTRATIVE CODE. MISSING THE FIRM'S NUMBER.
  
 10- SHEET A-2.1:
 A) FLOOR PLAN CALLS FOR ONE 16'X7' GARAGE DOOR.
 ELEVATION SHOWS 2 SMALL GARAGE DOORS.PRODUCT APPROVAL
 FOR GARAGE DOORS DON'T SHOW DOOR TO LOOK LIKE 2 DOORS
 IN ONE. HOW IS THIS ACHIEVED. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004
  
 11- SHEET S-2:
 A) DETAIL 1/S-2 CALLS FOR (3)2X4 STUDS, WHILE 2ND
 FLOOR FRAMING PLAN CALLS FOR (4)2X4 STUDS.
 CLARIFY/REVISE AS REQUIRED TO MATCH.
  
 19- SHEET S-3:
 A) REVISE PLYWOOD SHEATHING NAILING SCHEDULE FOR
 ROOF SHEATHING AT ZONE 3. SEE TABLE 2304.9.1 FBC 2004
 AND REVISE AS REQUIRED.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-11-16 Cont ID  
Sent By jgomez Date 2006-11-15 Time 17:58 Rev Time 3.50
Received By jgomez Date 2006-11-15 Time 17:52 Sent To  
Notes
2006-11-16 11:34:34BUILDING REVISION CHECKLIST (REVISION DONE UNDER FBC
 2004 AS SPECIFIED ON PLANS):
 1- SHEET A-1.0:
 A) REVISE TYPE OF CONSTRUCTION. SEE SEC. 602 FBC
 2004. TYPE OF CONSTRUCTION SHOWN ON PLANS APPLIES TO
 TYPE IIIB.
 B) ADD 2004 FLORIDA RESIDENTIAL CODE, WHICH IS THE
 ONE THAT APPLIES TO SINGLE FAMILY RESIDENCES.
 C) AREA CALCULATIONS ON SHEET A-1.0 ARE DIFFERENT
 THAN THOSE SHOWN ON SHEET A-1.1. REVISE AS REQUIRED.
  
 2- TRUSS DRAWINGS WILL BE REQUIRED FOR REVIEW PRIOR TO
 INSTALLATION. SEE SEC. R802.10 FOR REQUIRED
 INFORMATION.
  
 3- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF
 BEING RECORDED IF WORK IS NOT STARTED. SEC. 713.13(2)
 FLORIDA STATUTES. NEED RE-RECORDED NOTICE OF
 COMMENCEMENT.
  
 4- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY CHAPTER
 13 FBC 2004.
  
 5- BRING DRAWINGS TO PALM BEACH COUNTY FOR IMPACT FEES
 REVISION. BRING BACK STAMPED DRAWINGS AND PAID RECEIPT
 IF ADDITIONAL FEES ARE DUE.
  
 6- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS
 UNDER A SEPARATE PERMIT AS AGREED ON AT TIME OF
 ORIGINAL PERMIT APPLICATION APPROVAL.
  
 7- OWES ADDITIONAL FEES FOR UPDATED BUILDING VALUATION
 AND RADON FEES. FEES WILL BE CALCULATED WHEN ITEM 1(C)
 ABOVE IS CLARIFIED.
  
 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) INSWING ENTRY DOOR AS SHOWN ON PLANS.
 B) IMPACT SLIDING GLASS DOORS AS SPECIFIED ON
 PLANS.
 C) PRECAST CONCRETE LINTELS AS SPECIFIED ON PLANS.
 D) ALL SIMPSON OR USP CONNECTORS SPECIFIED ON FRAMING
 PLANS AND DETAILS.
 E) GARAGE DOOR. NEED CLEAR AND LEGIBLE DRAWINGS.
 CLARIFY IF USING THE DADE COUNTY NOA OR FLORIDA PRODUCT
 APPROVAL 4861. PROVIDE COMPLETE PACKAGE FOR EITHER ONE,
 BUT DON'T MISMATCH ONE WITH THE OTHER.
 F) ASPHALT SHINGLES. DOWNLOAD DADE COUNTY NOA
 04-0305.03 WHICH IS THE CORRECT NOA THAT WAS SUBMITTED
 TO OBTAIN FLORIDA PRODUCT APPROVAL #FL183-R1. GO TO
 WWW.FLORIDABUILDING.ORG TO DOWNLOAD ALL INFORMATION. G)
 SINGLE HUNG WINDOWS.
  
 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITTING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 10-SPECIFY SAFETY GLASS IN WINDOW LOCATED IN MASTER
 BATH TUB. SEC. R308.4 2004 FLORIDA RESIDENTIAL CODE.
  
 11- 2ND FLOOR ATTIC ACCESS SHALL BE IN HALLWAY OR
 ALREADY ACCESSIBLE LOCATION. REVISE AS REQUIRED. SEC.
 R807.1 2004 FLORIDA RESIDENTIAL CODE.
  
 12- ENGINEER TO PROVIDE ALL HIS INFORMATION AND FIRM'S
 CERTIFICATE OF AUTHORIZATION AS REQUIRED BY SEC.
 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE.
  
 13- ARCHITECT TO PROVIDE ALL HIS INFORMATION AND FIRM'S
 INFORMATION AS REQUIRED BY SEC. 61G1-16.004 OF FLORIDA
 ADMINISTRATIVE CODE.
  
 14- SURVEY TO HAVE ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 472 FLORIDA STATUTES.
  
 15- SHEET A-2.1:
 A) FLOOR PLAN CALLS FOR ONE 16'X7' GARAGE DOOR.
 ELEVATION SHOWS 2 SMALL GARAGE DOORS. CLARIFY/REVISE AS
 REQUIRED TO MATCH.
 B) REVISE ELEVATIONS ORIENTATION. SEE SURVEY FOR
 CORRECT ORIENTATION.
  
 16- SHEET A-3.1:
 A) PORCH SECTION AND TYP. WALL SECTION CALL FOR
 "ASPHALT TILE ROOF". CLARIFY WHAT IS IT?. REVISE AS
 REQUIRED.
 B) CHANGES DONE BY HAND ARE NOT ACCEPTABLE. EG:
 STUCCO THICKNESS. REVISE ORIGINAL DRAWINGS AS
 REQUIRED.
  
 17- SHEET A-4.1:
 A) DETAIL #1 IS FOR WINDOW AND DOOR BUCK DETAIL.
 CLARIFY TITLE SAYS WINDOW, WHILE DETAIL SAYS DOOR
 FRAME.
 B) THERE ARE TWO DIFFERENT SPECS FOR BUCK FASTENING.
 SEE DETAIL 1 AND WINDOW/DOOR BUCK NOTES ON SHEET S-2
 AND REVISE AS REQUIRED.
 C) HURRICANE PANEL DETAIL: EDGE DISTANCE IS
 INCORRECT. STUCCO THICKNESS CAN'T BE CONSIDERED FOR
 EDGE DISTANCE. REVISE AS REQUIRED. SEE ACTUAL STORM
 PANELS PRODUCT APPROVAL.
 ***NOTE: THIS DETAIL IS NOT REQUIRED. IT'S EASIER AND
 WILL AVOID DISCREPANCIES IF ONLY THE PRODUCT APPROVAL
 FOR STORM SHUTTERS IS SUPLLIED WHEN APPROVED BY THE
 DESIGNER OF RECORD.
 D) SECTION AT REAR PORCH: SPECIFY LEDGERS FOR ROOF
 SHEATHING SUPPORT AT MASONRY WALL. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
 C) SPECIFY FIREBLOCKING. SEC. R602.8 2004 FLORIDA
 RESIDENTIAL CODE.
  
 18- SHEET S-2:
 A) REVISE WINDOW NOTES. NEED WINDOWS FOR 140 MPH
 INSTALLATION, NOT 120. REVISE ORIGINAL DRAWING. HAND
 CHANGES ARE NOT ACCEPTABLE.
 B) BEARING WALL CONNECTION TO CBS DETAIL AND DETAIL
 1/S-2: CLARIFYIF USING SIMPSON OR USP CONNECTORS. C)
 DETAIL 1/S-2 CALLS FOR (3)2X4 STUDS, WHILE 2ND FLOOR
 FRAMING PLAN CALLS FOR (4)2X4 STUDS. CLARIFY/REVISE AS
 REQUIRED TO MATCH.
 D) SPECIFY ROOF TRUSS CONNECTORS FOR REAR PORCH
 ROOF.
  
 19- SHEET S-3:
 A) REVISE PLYWOOD SHEATHING NAILING SCHEDULE FOR
 ROOF SHEATHING. SEE TABLE 2304.9.1 FBC 2004 AND REVISE
 AS REQUIRED.
 B) SPECIFICATION GIVENON PLYWOOD SHEATHING NAILING
 SCHEDULE AND OVERHANG DETAIL DON'T MATCH. REVISE AS
 REQUIRED.
 C) CONNECTOR SCHEDULE: REVISE UPLIFT AND FASTENERS
 SPECIFIED FOR SIMPSON HETAL 16 AND SP4. SEE CURRENT
 CATALOGUE AND UPDATE AS REQUIRED. OTHERWISE, PROVIDE
 COMPLETE ENGINEERING ANALYSIS FOR VALUES AND NUMBERS
 THAT ARE DIFFERENT FROM THOSE TESTED AND PUBLISHED BY
 MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
 D) MAXIMUM DESIGN PRESSURES SHOWN ARE LOW COMPARED
 TO TABLE 1609.6B OR TABLES IN ASCE 7-02.PROVIDE
 ACTUAL CALCULATIONS SHOWING HOW THE MAXIMUM POSITIVE
 AND NEGATIVE LOADS ARE DETERMINED. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 10:33 Rev Time 0.00
Received By shill Date 2006-01-09 Time 10:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-03 Cont ID  
Sent By shill Date 2005-10-03 Time 18:49 Rev Time 0.50
Received By shill Date 2005-10-03 Time 18:49 Sent To PC
Notes
2005-10-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)ALL INFORMATION REQUIRED BY
 FAC61G15-23.002 IS TO BE ON THE SOILS
 REPORT (CA NUMBER).
  
 2.)THE SOILS REPORT IS FOR A ONE STORY
 STRUCTURE.
  
 3.)SHEET 3.1 DOES NOT MATCH THE
 MASTER.NOTES WERE ADDED ON THE NEW
 SHEET PREPARED BY WILLIAM GENZ, PE WHICH
 ARE NOT ON THE MASTER, SEE FLOOR FRAMING
 PLAN, ALTHOUGH THE REVISION NUMBER HAS
 REMAINED THE SAME.THE PLANS SUBMITTED
 TO BE ISSUED FROM A MASTER ARE TO
 EXACTLY MATCH THE MASTER.ANY TIME THAT
 REVISIONS ARE MADE TO ANY PLAN, THE
 DESIGNER IS TO CLEARLY INDICATE ALL
 CHANGES.FOR THE ENGINEER TO MAKE
 REVISIONS WHICH ARE NOT MARKED,
 REPRESENTING THEM AS THE SAME REVISION
 NUMBER AS A PREVIOUSLY APPROVED PLAN,
 DELAYS REVIEW TIME.PLEASE NOTE THAT
 DISCREPANCIES SUCH AS THIS ONE WILL
 RESULT IN THE PLANS BEING ROUTED THROUGH
 ALL TRADES TO ENSURE THAT OTHER CHANGES
 WERE NOT MADE.
  
 4.)SHEET 5.1 DOES NOT MATCH THE
 MASTER.THE REVISION NUMBERS AND DATES
 ARE NOT THE SAME AS ON THE MASTER.
  
 5.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 6.)PLANS ISSUED FROM A MASTER ARE
 REQUIRED TO INCLUDE ONLY THE FOLLOWING
 SHEETS:FLOOR PLAN (SHEET 4.1) AND
 ELEVATIONS (6.1).
  
 7.)ADDITIONAL FEES DUE (VALUATION
 ADJUSTMENT), SEE ATTACHED BILL.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-03-13 Cont ID  
Sent By dpalmer Date 2007-03-13 Time 09:58 Rev Time 0.00
Received By dpalmer Date 2007-03-13 Time 09:17 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-02-25 Cont ID  
Sent By dpalmer Date 2007-02-25 Time 14:16 Rev Time 0.00
Received By dpalmer Date 2007-02-25 Time 13:59 Sent To B
Notes
2007-02-25 14:16:31*** UNSAT ***
  
  
  
 1) NOTE: PLEASE CLARIFY WHERE THE AIC RATING FOR
 MAIN/SERVICE EQUIPMENT IS STATED ON PLANS. THIS USED TO
 BE ONE PLANS FROM PREVIOUS PROJECTS?
 110.9
 PLANS MAY NOT ONLY QUOTE THIS REQUIREMENT.
  
 2) NOTE: PLEASE SEE NOTE #1 ON RISER USED TO STATE THE
 CONDUIT FROM METER TO PANEL TO BE IN SLAB, HOWEVER THIS
 PART OF THE NOTE HAS BEEN REMOVED. THIS HAS BEEN
 REDLINED ON OTHER SETS OF PLANS WHEN PLANS WERE OK WITH
 OTHER COMMENTS.
 230.70, 230.71
 MUST BE IN SLAB OR MUST CONTAIN MAIN WITH OCP OUTSIDE.
  
 3) NOTE: PLEASE KNOW THAT A MEETING WAS HELD PREVIOUSLY
 WITH DESIGN TEAM REPRESENTATIVES AND INFORMATION WAS
 GIVEN WITH RESPECT TO THE DIFFERENCES OF SD(SMOKE
 DETECTORS) AND SA(SMOKE ALARMS) AND REQUIRED CHANGES
 WHICH WILL NEEDED ON FUTURE PLANS, HOWEVER THIS
 DESIGNATION HAS NOT BEEN CHANGED ON PLANS.
 *
 PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN
 SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY
 INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS
 ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN
 THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS
 OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE
 ALARMS.
 THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE
 OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED.
 BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE
 DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL
 NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY
 HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF
 SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS
 SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS
 SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS
 FOR OTHER NEW HOMES.
 ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC
 RESIDENTIAL CODE/ FBC AND IN NFPA-72.
 IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE*.
  
 4) NOTE: PLEASE SEE THAT THE FEES OWED PER PREVIOUS
 BUILDING REVIEW COMMENTS HAS NOT BEEN PAID.THIS WAS
 GIVEN AND IS ATTACHED ONCE AGAIN.
  
 ** ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-12-26 Cont ID  
Sent By dpalmer Date 2006-12-26 Time 12:36 Rev Time 0.00
Received By dpalmer Date 2006-12-26 Time 12:31 Sent To M
Notes
2006-12-26 12:37:56** UNSAT **
  
 1) NOTE: PLEASE SEE HAND DRAWN CHANGES MADE TO
 ELECTRICAL PLANS IN RED PENCIL. PLEASE KNOW THESE ARE
 NOT PERMITTED TO SIGNED AND SEALED PLANS.
 PLEASE SEE ALSO IT APPEARS THESE CHANGES ARE INDICATING
 A RELOCATION OF THE ATTIC ACCESS, LTS, AND SA DEVICE.
 PLEASE BE SURE SHEETS CORRELATE
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-08-10 Cont ID  
Sent By dpalmer Date 2006-08-10 Time 07:03 Rev Time 0.00
Received By dpalmer Date 2006-08-10 Time 06:58 Sent To P
Notes
2006-08-10 00:00:00**********UNSAT ***********
  
 1) NOTE: PLEASE CLARIFY UNDERGROUND
 SEC'S TO FPL. IF THESE ARE INSTALLED BY
 FPL , THEN PLEASE DO NOT INDICATE THE
 CONDUCTOR SIZES, AS THESE WILL NOT
 CORRELATE WITH FPL.
 PLEASE ALSO VERIFY THE DOWNSIZING OF THE
 NEURTRAL CONDUCTOR TO A #3.
 PLEASE PROVIDE NEUTRAL LOAD CALCULATION
 OR FULL SIZE NEUTRAL.
 220.22, 310.15B6
  
 2) NOTE: PLEASE SHOW CONDUIT SIZE FOR
 THE UNDERGROUND AND ALSO THE CONDUIT TO
 INSIDE PANEL. UNABLE TO VERIFY AT THIS
 TIME.
 FBC 106.1.2
  
 3) NOTE: PLEASE SEE 210.52 AS THERE ARE
 SOME RECEPTS MISSING . SEE REDLINED
 PLANS.
 PLEASE SEE AREA OF WALL OFF KITCHEN AND
 WHAT APPEARS TO BE THE MASTER BEDRM.
  
 4) NOTE: PLEASE SEE MISSING PENINSULAR
 GFI RECEPT. 210.52C3,210.8A6
  
 5) NOTE: PLEASE PROVIDE ALL ROOM AND
 AREA DESIGNATIONS ON PLANS AND CORRELATE
 WITH THE PANEL SCHEDULE.
 PLEASE SEE THAT ALL CIRCUITS ON PANEL
 SCHEDULE SHALL BE SPECIFIC TO ROOMS AND
 AREAS.
 IE; LIVING RM RECEPTS, BEDRM #2
 LTS/RECEPTS, HALL LTS ETC ETC.
 408.4 FBC 106.1.2
 **IT IS KNOWN THAT CIRCUITING DURING
 CONSTRUCTION WILL CHANGE AND THIS CAN EB
 REVISED AT A LATER DATE.
  
 6) NOTE: PLEASE SEE ONLY TWO CIRCUITS
 ARE BEIGN SHOWNWITH ARC FAULT
 PROTECTION FOR ALL BEDRMS LTS, RECEPTS
 AND SD'S. PLEASE KNOW, THE CODE HAS
 CHANGED FROM PREVIOUSLY SUBMITTED PLANS
 UNDER THIS PROJECT TO REQUIRE ARC FAULT
 PROTECTION FOR ALL OUTLETS IN BEDRMS.
 PLEASE BE SURE TO REVISE AS THE LOAD ON
 THESE ONLY TWO CIRCUITS SEEM TO EXCEED
 RATINGS.
 210.12B(2002) NEC. 210.52,220
  
 7)NOTE: PLEASE SEE MISSING THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S).
 210.11C3, SHALL BE 20A AND #12.
 NO BATH(S) LISTED.
  
 8) NOTE: PLEASE BE SURE HE PLANS PROVIDE
 THE FOLLOWING MINIMUM CODES AS ADOPTED
 FOR DESIGN AND FS/FBC 2004
 2002 NFPA-70, 2002 NFPA-72, 2003
 NFPA-101.
  
 9) NOTE: PLEASE SEE PLANS INDICATE THE
 PANEL LOCATED IN GARAGE, YET PANEL
 MENTIONS THIS IN HALL/UTILITY.
  
 10) NOTE: PLEASE SEE MIN EGRESS LIGHTING
 IS REQUIRED FOR WHAT APPEARS TO BE
 DINGIN AND LIV RM FOR EGRESS. SHOWS ONLY
 A JUNCTION BOX FOR FUTURE FAN. PLEASE
 KNOW, THIS CAN BE EITHER PROVIDED BY THE
 SWITCHING OF A RECEPT OR A LT FIXTURE OF
 SOME TYPE WHICH SHALL BE PROIVIDED.
 210.70, LS101 7.8
  
 11) NOTE: PLEASE SEE PLANS SHOWS A METER
 AND A MAIN DISCONNECT ON THE OUTSIDE. IF
 THIS IS THE CASE, PLEASE REVISE RISER TO
 INCLUDE THIS MAIN AND ALSO INCLUDE
 EQUIPMENT GROUNDING CONDUCTORS AS
 REQUIRED.
 250.24B, 250.122
 106.1.2
  
 12) NOTE: PLEASE SEE SURVEY PROVIDED IN
 PACKAGE IS REQUIRED TO CONTAIN AN
 ORIGINAL SIAGNAURE IN ORDER FOR SURVEY
 TO BE VALID. PLEASE SEE FAC 61G15-17, FS
 472.025
  
 13) NOTE: PLEASE SEE MISSING THE DINING
 ROOM CIRCUITS ON ONE OR MORE OF THE SM
 APPL CIRCUITS. 210.11C1,220.16
  
 14) NOTE: PLEASE SEE 210.4B AS THE
 DISHWASHER/DISPOSAL ARE FROM THE SAME
 RECEPT, HOWEVER THESE ARE ON 1-POLE
 BREAKERS. THIS REQUIRES A 2-POLE BRKR.
  
 15) NOTE: PLEASE SEE COUNTER SPACE IN
 KTICHEN AS IT SEEMS IT IS MISSING GFI
 RECEPT(S). PLEASE SEE 210.52C1 AND
 REDLINED PLANS.
  
 16) NOTE: PLEASE SEE "S" SHEETS AS THESE
 ARE MISSING THE REQUIRED CERTIFICATE OF
 AUTHORIZATION NUMBER FOR ENGINEERING
 FIRM.
 FAC 61G15-23.002, FS 471.023
  
 ** IMPORTANT **
 BEFORE RESUBMITTING PLANS ONCE ALL
 REVIEWS ARE COMPLETED. PLEASE BE SURE TO
 COMPLETELY REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 ONLY ONE COPY OF THE OLD SHEETS SHOULD
 BE SUBMITTED FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By dpalmer Date 2006-02-06 Time 07:33 Rev Time 0.00
Received By dpalmer Date 2006-02-06 Time 07:25 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 10:32 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-02-22 Cont ID  
Sent By adarroug Date 2007-02-22 Time 13:17 Rev Time 0.00
Received By adarroug Date 2007-02-22 Time 13:17 Sent To E
Notes
2007-02-22 13:18:17TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 09:01 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 09:01 Sent To E
Notes
2006-12-26 09:02:07TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-12-15 Cont ID  
Sent By adarroug Date 2006-12-15 Time 11:15 Rev Time 0.00
Received By adarroug Date 2006-12-15 Time 11:15 Sent To Z
Notes
2006-12-15 11:15:17TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-09 Cont ID  
Sent By adarroug Date 2006-08-09 Time 09:21 Rev Time 0.00
Received By adarroug Date 2006-08-09 Time 09:21 Sent To E
Notes
2006-08-09 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 08:50 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 08:50 Sent To Z
Notes
2006-08-01 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 09:08 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 09:08 Sent To E
Notes
2006-01-30 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-06 Cont ID  
Sent By adarroug Date 2006-01-06 Time 08:55 Rev Time 0.00
Received By adarroug Date 2006-01-06 Time 08:55 Sent To B
Notes
2006-01-06 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-27 Cont ID  
Sent By adarroug Date 2005-12-27 Time 16:14 Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 16:14 Sent To Z
Notes
2005-12-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 14:40 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 14:40 Sent To B
Notes
2005-09-27 00:00:00TO "SHILL" DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-03 Cont ID  
Sent By shill Date 2005-10-03 Time 10:32 Rev Time 0.00
Received By shill Date 2005-09-21 Time 14:14 Sent To  
Notes
2005-09-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-08-24 Cont ID  
Sent By tgordon Date 2007-08-24 Time 14:54 Rev Time 0.30
Received By tgordon Date 2007-08-24 Time 14:53 Sent To  
Notes
2007-08-24 14:54:31REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-01-18 Cont ID  
Sent By pkrauss Date 2007-01-18 Time 11:17 Rev Time 0.00
Received By pkrauss Date 2007-01-18 Time 10:20 Sent To B
Notes
2007-01-18 11:22:31PROVISO:
 1.PER 2004 FRC M1602.4, PRESSURE DIFFERENTIALS ACROSS
 CLOSED DOORS WHERE RETURNS ARE CENTRALLY LOCATED SHALL
 BE LIMITEDTO .01 INCH WC (2.5 PASCALS) OR LESS.
  
 2.FOR PROPER SIZING OF RETURN AIR FROM THE MATER
 SUITE, ALL AIR SUPPLY INTO THE MASTER SUITESHALL BE
 INCLUDED FOR TOTAL SUPPLY AIR (INCLUDE SUPPLY AIR TO
 CLOSETS, BATHROOM, ETC) AND SIZE RETURN ACCORDINGLY.
 2004 FRC M1602.4 EXCEPTION 1 AND 3.TEST AND BALANCE
 REQUIRED FOR FINAL INSPECTION.
  
 3.AUXILIARY DRAIN PAN WITH OVERFLOW PROTECTION
 REQUIRED PER 2004 FRC M1411.3.1.
  
 4.A MINIMUM OF 4" CLEARANCE AROUND THE AHU IS
 REQUIRED IN ACCORDANCE WITH 2004 FBC CHAPTER 13
 SUB-CHAPTER 13-610.1.ABC.3.0.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS
 AT (561)805-6719 OR E-MAIL [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2006-11-02 Cont ID  
Sent By pkrauss Date 2006-11-02 Time 08:24 Rev Time 0.00
Received By pkrauss Date 2006-11-02 Time 08:24 Sent To B
Notes
2006-11-02 08:25:06MECHANICAL REVISION REQUIRED.
  
 NO MECHANICAL PLANS SUBMITTED FOR REVIEW.PLANS
 APPROVED UNDER THE MASTER PERMIT 04031090 DO NOT MATCH
 THE REVISED PLANS.
  
 A MECHANICAL REVISION WILL BE REQUIRED PRIOR TO ROUGH
 INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS
 AT (561)805-6719 OR E-MAIL [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 10:33 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-01-17 Cont ID  
Sent By pschmitz Date 2007-01-17 Time 09:41 Rev Time 0.00
Received By pschmitz Date 2007-01-17 Time 09:39 Sent To  
Notes
2007-01-17 09:41:00RE-SUB

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-08-19 Cont ID  
Sent By pschmitz Date 2006-08-19 Time 06:44 Rev Time 0.00
Received By pschmitz Date 2006-08-19 Time 06:44 Sent To M
Notes
2006-08-19 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 UNSAT
  
 SEC 106.3.5.4 RESIDENTAL
 (ONE AND TWO FAMILY)
 (9) PLUMBING.
 SANITARY ISOMETRIC RISER DIAGRAM,
 REUIIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 10:33 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2006-12-19 Cont ID  
Sent By mmclean Date 2006-12-19 Time 14:27 Rev Time 0.00
Received By mmclean Date 2006-12-19 Time 14:27 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2006-08-08 Cont ID  
Sent By mmclean Date 2006-08-07 Time 11:30 Rev Time 0.00
Received By mmclean Date 2006-08-07 Time 11:30 Sent To I
Notes
2006-08-08 00:00:00DENIED,
 1. THE PROPOSED DRIVEWAY NEED TO BE
 REDUCE TO MEET THE ZONING GUIDELINES.
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 2. NEED TO REDUCE THE DRIVEWAY AND
 PROVIDE TWO COPY OF SURVEY WITH
 MEASUREMENTS (WIDTH & LENGTH)
  
 NOTE:
 THE PROPOSED A/C EQUIPMENT SHALL NOT BE
 CLOSER THAN 1FT FROM SIDE PROPERTY LINE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-05 Cont ID  
Sent By mmclean Date 2006-01-05 Time 11:17 Rev Time 0.00
Received By mmclean Date 2006-01-05 Time 11:17 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By mmclean Date 2005-09-26 Time 18:35 Rev Time 0.00
Received By mmclean Date 2005-09-26 Time 18:35 Sent To I
Notes
2005-09-26 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK.
  
 NOTE: MUST MAINTAIN 1000SQ FT FOR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720