Plan Review Details - Permit 05090812
Plan Review Stops For Permit 05090812
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-11-21 Cont ID  
Sent By shill Date 2006-11-21 Time 17:10 Rev Time 0.00
Received By shill Date 2006-11-21 Time 17:10 Sent To  
Notes
2006-11-21 17:38:23REVISION, ALL SHEETS, CHANGED TO FBC2004

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2006-11-21 Cont ID  
Sent By shill Date 2006-11-21 Time 12:02 Rev Time 0.00
Received By shill Date 2006-11-21 Time 12:02 Sent To  
Notes
2006-11-21 12:17:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC EB
 FLORIDA BUILDING CODE 2004 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)THE DESIGNER HAS ELECTED TO SUBMIT NEW PLANS IN
 ACCORDANCE WITH FBC2004.THE ENERGY CALCS PREVIOUSLY
 REVIEWED WERE FBC2001 FORMS.NEW ENERGY CALCS
 REQUIRED, FBC 13.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-11-06 Cont ID  
Sent By shill Date 2006-11-06 Time 09:55 Rev Time 0.00
Received By shill Date 2006-11-06 Time 09:55 Sent To  
Notes
2006-11-06 09:58:23****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)THIS PERMIT WAS APPLIED FOR UNDER THE 2001 CODE.
 REVISION STATES 2004.BASED ON APPLICATION DATE,
 EITHER CODE COULD BE USED BUT YOU HAVE TO PICK ONE.IF
 YOU WISH TO USE THE 2004 CODE, SUBMIT NEW PLANS FOR THE
 HOUSE IN COMPLIANCE WITH FBC2004.PLANS OTHERWISE
 APPEAR CODE COMPLIANT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-08-07 Cont ID  
Sent By shill Date 2006-08-07 Time 10:21 Rev Time 0.00
Received By shill Date 2006-08-07 Time 10:21 Sent To Z
Notes
2006-08-07 00:00:00PORCH, DETACHED GARAGE
 REVISED 2.1 (TWO DIFFERENT SHEETS), 3.1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 14:18 Rev Time 0.00
Received By shill Date 2006-01-09 Time 14:18 Sent To  
Notes
2006-01-09 00:00:00SEE MASTER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-10-04 Cont ID  
Sent By shill Date 2005-10-04 Time 07:48 Rev Time 0.50
Received By shill Date 2005-10-04 Time 07:48 Sent To PC
Notes
2005-10-04 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)ALL INFORMATION REQUIRED BY
 FAC61G15-23.002 IS TO BE ON THE SOILS
 REPORT (CA NUMBER).
  
 2.)THE SOILS REPORT IS FOR A ONE STORY
 STRUCTURE.
  
 3.)SHEET 3.1 DOES NOT MATCH THE
 MASTER.NOTES WERE ADDED ON THE NEW
 SHEET PREPARED BY WILLIAM GENZ, PE WHICH
 ARE NOT ON THE MASTER, SEE FLOOR FRAMING
 PLAN, ALTHOUGH THE REVISION NUMBER HAS
 REMAINED THE SAME.THE PLANS SUBMITTED
 TO BE ISSUED FROM A MASTER ARE TO
 EXACTLY MATCH THE MASTER.ANY TIME THAT
 REVISIONS ARE MADE TO ANY PLAN, THE
 DESIGNER IS TO CLEARLY INDICATE ALL
 CHANGES.FOR THE ENGINEER TO MAKE
 REVISIONS WHICH ARE NOT MARKED,
 REPRESENTING THEM AS THE SAME REVISION
 NUMBER AS A PREVIOUSLY APPROVED PLAN,
 DELAYS REVIEW TIME.PLEASE NOTE THAT
 DISCREPANCIES SUCH AS THIS ONE WILL
 RESULT IN THE PLANS BEING ROUTED THROUGH
 ALL TRADES TO ENSURE THAT OTHER CHANGES
 WERE NOT MADE.
  
 4.)SHEET 5.1 DOES NOT MATCH THE
 MASTER.THE REVISION NUMBERS AND DATES
 ARE NOT THE SAME AS ON THE MASTER.
  
 5.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 6.)PLANS ISSUED FROM A MASTER ARE
 REQUIRED TO INCLUDE ONLY THE FOLLOWING
 SHEETS:FLOOR PLAN (SHEET 4.1) AND
 ELEVATIONS (6.1).
  
 7.)ADDITIONAL FEES DUE (VALUATION
 ADJUSTMENT), SEE ATTACHED BILL.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-30 Cont ID  
Sent By dpalmer Date 2006-11-30 Time 12:50 Rev Time 0.00
Received By dpalmer Date 2006-11-30 Time 12:46 Sent To M
Notes
2006-11-30 12:51:18REDLINED CIRCUITS ADDED FOR GARAGE ON PANEL SCHEDULE OK
 AS REDLINED ON ALL MODELS.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-10-29 Cont ID  
Sent By dpalmer Date 2006-10-29 Time 09:32 Rev Time 0.00
Received By dpalmer Date 2006-10-29 Time 09:31 Sent To M
Notes
2006-10-29 09:33:33***UNSAT ***
  
 1) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO THE
 DETACHED GARAGE, DISCONNECTING MEANS, GROUNDING
 ELECTRODE SYSTEM, CIRCUITS ON PANEL SCHEDULE ETC.
 225.31, 250.32 ETC,
 408.4, 310.16 ETC.
 THIS MODEL ACTUALLYDOES LIST THE GDO ON PANEL
 SCHEDULE.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-08-05 Cont ID  
Sent By dpalmer Date 2006-08-05 Time 09:11 Rev Time 0.00
Received By dpalmer Date 2006-08-05 Time 09:10 Sent To B
Notes
2006-08-05 00:00:00************ UNSAT ************
  
 1) NOTE: PLEASE SEE 225.31-225.39, FOR
 FEEDS GOING TO GARAGE.
 PLEASE ALSO REVISE MAIN HOUSE PLANS
 SHOWING GARAGE AS ORIG PLANS DID NOT
 INCLUDE CIRUITING ON PANEL SCHEDULE, OR
 DISCONNECTS ETC ON RISER.
  
 2) NOTE: PLEASE SEE 250.32 FOR GROUNDING
 ELECTRODE SYSTEM REQUIRED AT THE
 DETACHED GARAGE.
  
  
 3) NOTE: PLEASE ALSO SEE THAT THE PLANS
 SHALL INCLUDE ALL OTHER EXISTING
 ELECTRICAL WHICH IS ACTUALLY NEW AS THE
 HOUSE IS UNDER CONSTRUCTION.
  
 4) NOTE: PLEASE BE SURE THE DESIGNER OF
 RECORD SIGNS, DATES AND SEALS THE
 ELECTRICAL REVISIONS AS THE DESIGNER OF
 RECORD WHICH IS ALREADY ON FILE.
 PLEASE SEE FS 481.025
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By dpalmer Date 2006-02-06 Time 07:46 Rev Time 0.00
Received By dpalmer Date 2006-02-06 Time 07:39 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 14:18 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 09:49 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 09:49 Sent To P
Notes
2007-08-03 09:49:38TO "JLEECH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-07-18 Cont ID  
Sent By adarroug Date 2007-07-18 Time 09:31 Rev Time 0.00
Received By adarroug Date 2007-07-18 Time 09:31 Sent To P
Notes
2007-07-18 09:31:32TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-11-30 Cont ID  
Sent By dpalmer Date 2006-11-30 Time 12:46 Rev Time 0.00
Received By dpalmer Date 2006-11-30 Time 12:46 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-10-28 Cont ID  
Sent By adarroug Date 2006-10-28 Time 13:22 Rev Time 0.00
Received By adarroug Date 2006-10-28 Time 13:22 Sent To E
Notes
2006-10-28 13:23:14TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-10-23 Cont ID  
Sent By adarroug Date 2006-10-23 Time 15:11 Rev Time 0.00
Received By adarroug Date 2006-10-23 Time 15:11 Sent To Z
Notes
2006-10-23 15:11:51TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-31 Cont ID  
Sent By adarroug Date 2006-07-31 Time 14:50 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 14:50 Sent To E
Notes
2006-07-31 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 09:13 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 09:13 Sent To E
Notes
2006-01-30 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-09 Cont ID  
Sent By adarroug Date 2006-01-09 Time 10:15 Rev Time 0.00
Received By adarroug Date 2006-01-09 Time 10:15 Sent To B
Notes
2006-01-09 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-27 Cont ID  
Sent By adarroug Date 2005-12-27 Time 16:09 Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 16:09 Sent To Z
Notes
2005-12-27 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 14:43 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 14:43 Sent To B
Notes
2005-09-27 00:00:00TO "SHILL" DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-10-04 Cont ID  
Sent By shill Date 2005-10-04 Time 14:19 Rev Time 0.00
Received By shill Date 2005-09-21 Time 14:13 Sent To  
Notes
2005-09-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-12-01 Cont ID  
Sent By tgordon Date 2006-12-01 Time 09:02 Rev Time 0.25
Received By tgordon Date 2006-12-01 Time 09:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-10-30 Cont ID  
Sent By tgordon Date 2006-10-30 Time 11:41 Rev Time 0.20
Received By tgordon Date 2006-10-30 Time 11:41 Sent To P
Notes
2006-10-30 11:42:06*** DENIED ***
 1) 8"RETURN AIR TRANSFER DUCT TO BEDROOM #1 IS TO
 SMALL, SEE NOTE #3 (A).
  
 2) 9"RETURN AIR TRANSFER DUCT TO MASTER SUITE IS TO
 SMALL, SEE NOTE #3 (A) AND (C) EXCEPT.
  
 3) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 14:19 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-08-06 Cont ID  
Sent By jleech Date 2007-08-06 Time 10:23 Rev Time 0.00
Received By jleech Date 2007-08-06 Time 10:23 Sent To  
Notes
2007-08-06 10:24:03PLUMBING RISER REVISED OK

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-07-30 Cont ID  
Sent By jleech Date 2007-07-30 Time 09:44 Rev Time 0.00
Received By jleech Date 2007-07-30 Time 09:44 Sent To  
Notes
2007-07-30 09:46:12ALL REVISIONS MUST BE APPROVED BY DESIGN PROFESSIONAL.
 SEALED SIGNED AND DATED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-11-17 Cont ID  
Sent By jleech Date 2006-11-17 Time 13:28 Rev Time 0.00
Received By jleech Date 2006-11-17 Time 13:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-01-09 Cont ID  
Sent By shill Date 2006-01-09 Time 14:19 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2006-10-27 Cont ID  
Sent By mmclean Date 2006-10-27 Time 16:25 Rev Time 0.00
Received By mmclean Date 2006-10-27 Time 16:25 Sent To I
Notes
2006-10-27 16:25:42PROPOSED DETACHED GARAGE.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-08-08 Cont ID  
Sent By mmclean Date 2006-08-08 Time 09:01 Rev Time 0.00
Received By mmclean Date 2006-08-08 Time 09:00 Sent To  
Notes
2006-08-08 00:00:00REV - ADD A DETACHED GARAGE AND COVERED
 PORCH

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-06 Cont ID  
Sent By mmclean Date 2006-01-06 Time 11:03 Rev Time 0.00
Received By mmclean Date 2006-01-06 Time 11:03 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-09-26 Cont ID  
Sent By mmclean Date 2005-09-26 Time 18:27 Rev Time 0.00
Received By mmclean Date 2005-09-26 Time 18:27 Sent To I
Notes
2005-09-26 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK.
  
 NOTE: MUST MAINTAIN 1000SQ FT FOR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720