Plan Review Stops For Permit 05090679 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-12-13 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2005-12-13 |
Time |
12:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2005-10-14 |
Time |
08:19 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2005-10-14 |
Time |
08:19 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-12-02 |
Time |
18:04 |
Rev Time |
0.25 |
Received By |
btrobaug |
Date |
2005-12-02 |
Time |
17:57 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-11-22 |
Time |
11:16 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2005-11-22 |
Time |
10:58 |
Sent To |
P |
|
Notes |
2005-11-22 00:00:00 | | | THE COMMENTS FOR THIS REVIEW ARE THE | | SAME AS THE LAST REVIEW. | | | | THE ENGINEER OF RECORD NEEDS TO INDICATE | | IF THE "PANEL" SHOWN ON SHEET 2 OF 3 | | ELECTRICAL SCHEMATIC IS NEW OR EXISTING. | | IF IT IS NEW PLEASE SUBMIT DETAILS FOR | | THE PANEL SHOWN ON THE SCHEMATIC, FEEDER | | AND CONDUIT SIZE AND TYPE, PANEL RATING | | AND OCP, PANEL SCHEDULE AND COMPUTED | | LOAD. | | | | MR KOVNER NEEDS TO CALL ME REGARDING | | THIS MATTER IF THERE ARE ANY QUESTIONS. | | | | ALSO THE ELECTRICAL CONTRACTOR | | SUBMITTING THE PANEL SCHEDULE HAS AN | | INCORRECT ADDRESS. THE PANEL SCHEDULE | | ALONE DOES NOT RESPOND TO ALL OF THE | | COMMENT. FEEDER CONDUIT AND CONDUCTOR | | SIZES ARE NOT ADDRESSED, AND MAY NOT | | NEED TO BE IF THE PANEL ON THE SCHEMATIC | | IS EXISTING, ONE OF THE ISSUES THE | | ENGINEER OF RECORD HAS NOT CORRECTED. | | | | DO NOT RESUBMIT WITHOUT A CORRECTED | | WIRING SCHEMATIC. SEE FLORIDA STATUTE | | 553.80, ATTACHED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-09-23 |
Time |
16:08 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2005-09-23 |
Time |
15:27 |
Sent To |
P |
|
Notes |
2005-09-23 00:00:00 | | | THE ENGINEER OF RECORD NEEDS TO INDICATE | | IF THE "PANEL" SHOWN ON SHEET 2 OF 3 | | ELECTRICAL SCHEMATIC IS NEW OR EXISTING. | | IF IT IS NEW PLEASE SUBMIT DETAILS FOR | | THE PANEL SHOWN ON THE SCHEMATIC, FEEDER | | AND CONDUIT SIZE AND TYPE, PANEL RATING | | AND OCP, PANEL SCHEDULE AND COMPUTED | | LOAD. | | | | MR KOVNER NEEDS TO CALL ME REGARDING | | THIS MATTER IF THERE ARE ANY QUESTIONS. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | FAX/:561/659-8026 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-13 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2005-12-13 |
Time |
08:28 |
Sent To |
P |
|
Notes |
2005-12-13 00:00:00 | POOL HEATER BY GAS CONTRACTOR PLANS | | REQUIRED WITH PERMIT APPICATION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2006-02-16 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2006-02-16 |
Time |
16:02 |
Sent To |
|
|
Notes |
2006-02-16 00:00:00 | REV/PLUM GIVEN TO MIKE PEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2005-11-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-22 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-22 |
Time |
09:20 |
Sent To |
E |
|
Notes |
2005-11-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-11-17 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-11-17 |
Time |
17:03 |
Sent To |
Z |
|
Notes |
2005-11-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-23 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-23 |
Time |
08:54 |
Sent To |
E |
|
Notes |
2005-09-23 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-09-16 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-09-16 |
Time |
10:48 |
Sent To |
Z |
|
Notes |
2005-09-16 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-02-16 |
Time |
16:34 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-02-16 |
Time |
16:34 |
Sent To |
|
|
Notes |
2006-02-16 00:00:00 | REVISION: ADD MAXIMUM VENT LINE DETAIL | | TO POOL PRINT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2005-12-13 |
Time |
08:30 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2005-12-13 |
Time |
08:30 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2005-09-27 |
Time |
15:37 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2005-10-03 |
Time |
10:35 |
Sent To |
B |
|
Notes |
2005-10-03 00:00:00 | DENIED; | | 1.ALL WATER HEATING EQUIPMENT SHALL BE | | INSTALLED WITH FLANGES OR UNION | | CONECTIONS. SEC.424.2.14.4. | | 2.FBC 2001424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. PLEASE ADD TO | | NOTES. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-11-21 |
Time |
17:05 |
Rev Time |
0.10 |
Received By |
mmclean |
Date |
2005-11-21 |
Time |
16:56 |
Sent To |
I |
|
Notes |
2005-11-21 00:00:00 | NOTE: POOL & DECK MUST BE BEYOND THE | | 25FT FRONT SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2005-09-22 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2005-09-22 |
Time |
14:33 |
Sent To |
I |
|
Notes |