Plan Review Stops For Permit 05090560 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2006-06-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-10 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-10 |
Time |
18:41 |
Sent To |
|
|
Notes |
2006-06-10 00:00:00 | THIRD REVIEW OF REVISION, RE-SUBMITTED | | ON 6/2/06 TO REDUCE HEIGHT OF ENTRY | | DOORS, AND SUBMITTAL FOR ALTERNATIVE | | STORM PANEL SHUTTERS TO ADDRESS PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2006-06-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-10 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-10 |
Time |
18:40 |
Sent To |
|
|
Notes |
2006-06-10 00:00:00 | SUBMITTAL ON 4/28/06 FOR LIGHT POLE | | CONCRETE BASE DESIGN |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2006-06-10 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-06-10 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-06-10 |
Time |
18:39 |
Sent To |
|
|
Notes |
2006-06-10 00:00:00 | REVISION SUBMITTED 4/24/06 FOR SHEET | | A-4.2 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2006-05-16 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-05-16 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-05-16 |
Time |
07:33 |
Sent To |
|
|
Notes |
2006-05-16 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | SECOND REVIEW OF REVISION TO REDUCE | | HEIGHT OF ENTRY DOORS, AND SUBMITTAL FOR | | ALTERNATIVE STORM PANEL SHUTTERS TO | | ADDRESS PROVISO. | | | | 5) THIS COMMENT WAS NOT ADDRESSED FROM | | THE PREVIOUS REVIEW.ARCHITECTURAL PLAN | | SHEET A-4.1 AND MODULAR BUILDING PLAN | | SHEET 7 OF 7, SHOW DOOR AND WINDOW BUCKS | | OF 1"X 4" P.T.WOOD, SCREWED TO THE METAL | | FRAMESTRUCTURE.SHEET A-4.1 SHOULD BE | | REVISED TO SHOW HOW THE SHUTTERS WILL BE | | ANCHORED, IN ACCORDANCE WITH THE PRODUCT | | APPROVAL, TO THE STEEL FRAME STRUCTURE. | | ALSO, THE SAME COMMENT ALSO APPLIES TO | | ANCHORING OF THE STOREFRONT PER THE | | SUBMITTED ARCH ALUMINUM PRODUCT | | APPROVAL.PROVIDE THE REQUIRED | | ADDITIONAL DETAILS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | TELEPHONE: (561) 805 6652ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2006-04-09 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-04-09 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-04-09 |
Time |
15:42 |
Sent To |
|
|
Notes |
2006-04-09 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | REVISION TO REDUCE HEIGHT OF ENTRY | | DOORS, AND SUBMITTAL FOR ALTERNATIVE | | STORM PANEL SHUTTERS TO ADDRESS PROVISO. | | | | 1) ONLY ONE COPY OF REVISED SHEETS A-3.0 | | AND A-4.1 WAS SUBMITTED.TWO SIGNED AND | | SEALED COPIES OF EACH REVISED SHEET | | SHOULD HAVE BEEN SUBMITTED, ONE COPY FOR | | PERMIT FILE AND ONE FOR THE JOB SITE. | | | | 2) THE SUBMITTED SHEETS A-3.0 AND A-4.1 | | ARE REVISIONS OF THE SHEETS REVIEWED FOR | | PERMIT ISSUANCE.THEY WERE BROUGHT IN | | AS SUBMITTALS, WHEN THEY ARE IN FACT | | REVISIONS.A REVISION FEE OF $70 IS | | DUE.THE FEE IS DERIVED FROM THE | | STANDARD REVISION FEE OF $50 PLUS $10 | | PER REVISED SHEET (IN THIS CASE, TWO | | SHEETS).PLEASE PAY THE REQUIRED FEE | | WHEN RESUBMITTING. | | | | 3) AS NOTED IN COMMENTS 1 AND 2, ABOVE, | | THE PLANS HAVE BEEN REVISED TO REDUCE | | THE STOREFRONT DOOR HEIGHT TO MATCH THE | | SCOPE OF THE STOREFRONT DOOR PRODUCT | | APPROVALS THAT WERE PREVIOUSLY | | SUBMITTED.PRIOR TO THE PLAN REVISION, | | THE STOREFRONT DOOR PRODUCT APPROVALS | | COULD NOT BE STAMPED AS SUITABLE FOR THE | | PROJECT, SO ALL COPIES WERE RETURNED TO | | YOU, UNSTAMPED.NOW THAT THE PLANS HAVE | | BEEN REVISED, TWO COPIES OF THE | | STOREFRONT DOOR PRODUCT APPROVALS MUST | | BE SUBMITTED FOR REVIEW.THE PRODUCT | | APPROVALS THAT WERE PREVIOUSLY SUBMITTED | | ARE ARCH ALUMINUM STOREFRONT DOOR | | PRODUCT APPROVALSNOA# 01-0226.05 AND | | 02-0904.02. | | | | 4) ONLY ONE COPY OF THE POMA CORPORATION | | ALUMINUM STORM PANEL SHUTTER PRODUCT | | APPROVAL NOA# 02-0417.06 WAS SUBMITTED. | | TWO COPIES ARE REQUIRED.ALSO, THE | | STATEWIDE PRODUCT APPROVAL COVER SHEET | | WAS NOT SUBMITTED.I HAVE PRINTED THE | | RELEVANT COVER SHEET AND ATTACHED IT TO | | THE SUBMITTED PRODUCT APPROVAL SO THAT | | TWO COMPLETE COPIES CAN BE RESUBMITTED, | | ASSUMING COMMENT 5, BELOW, CAN BE | | ADDRESSED WITHOUT HAVING TO SELECT A | | DIFFERENT SHUTTER SUPPLIER. | | | | 5) ARCHITECTURAL PLAN SHEET A-4.1 AND | | MODULAR BUILDING PLAN SHEET 7 OF 7, SHOW | | DOOR AND WINDOW BUCKS OF 1"X 4" P.T. | | WOOD, SCREWED TO THE METAL FRAME | | STRUCTURE.SHEET A-4.1 SHOULD BE | | REVISED TO SHOW HOW THE SHUTTERS WILL BE | | ANCHORED, IN ACCORDANCE WITH THE PRODUCT | | APPROVAL, TO THE STEEL FRAME STRUCTURE. | | ALSO, THE SAME COMMENT ALSO APPLIES TO | | ANCHORING OF THE STOREFRONT PER THE | | SUBMITTED ARCH ALUMINUM PRODUCT | | APPROVAL.PROVIDE THE REQUIRED | | ADDITIONAL DETAILS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | TELEPHONE: (561) 805 6652ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-02-23 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-02-23 |
Time |
07:06 |
Sent To |
|
|
Notes |
2006-02-23 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6652 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | --PROVISO-- | | FBC 1606.1SUBMIT ALTERNATIVE | | STOREFRONT DOOR PRODUCT APPROVALS OR | | REVISE THE PLANS.THE SUBMITTED ARCH | | ALUMINUM STOREFRONT DOOR PRODUCT | | APPROVALS REFERENCE MIAMI-DADE NOA# | | 01-0226.05 AND 02-0904.02.BOTH | | DOCUMENTS SHOW A MAXIMUM DOOR FRAME | | HEIGHT OF 97" WHICH IS LESS THAN THE | | PROPOSED 120" (9'-2") DOOR FRAME SHOWN | | ON SHEET A-4.1 OF THE PLANS.THE 120" | | DOOR IS OUTSIDE OF THE SCOPE OF THE | | SUBMITTED PRODUCT APPROVALS. | | | | --PROVISO-- | | FBC 1606.1.4SUBMIT AN ALTERNATIVE | | STORM PANEL SHUTTER PRODUCT APPROVAL. | | THE SUBMITTED EASTERN METAL SUPPLY | | SHUTTER PRODUCT APPROVAL REFERENCES | | MIAMI-DADE NOA# 03-0716.02 WHICH STATES | | THAT THE MAXIMUM ALLOWABLE STORM PANEL | | LENGTH IS 9'-0".THE PLANS SHOW | | STOREFRONT WINDOWS THAT EXCEED 9'-0", | | BOTH HORIZONTALLY AND VERTICALLY.THESE | | WINDOW SIZES ARE OUTSIDE THE SCOPE OF | | THE SUBMITTED PRODUCT APPROVAL | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-02-01 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2006-02-01 |
Time |
20:45 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-02-01 |
Time |
19:01 |
Sent To |
|
|
Notes |
2006-02-01 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FLORIDA BUILDING CODE 2001 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 12/19/05: | | | | 2) THIS COMMENT HAS NOT BEEN PROPERLY | | ADDRESSED.THE COMMENT RESPONSE LETTER | | STATES THAT NO REFERENCE TO 2004 FLORIDA | | BUILDING CODE COULD BE FOUND.THAT IS | | NOT CORRECT.PLEASE SEE THE BOTTOM LINE | | OF TEXT ON FRED S. CARDWELL, P.E., P.L.S | | FOUNDATION PLAN SHEET A-1 WHICH STATES | | DESIGN IN ACCORDANCE WITH 2004 FLORIDA | | BUILDING CODE.THAT NOTE DOES NOT | | CORRELATE WITH STRUCTURAL SHEET S-0, | | GENERAL NOTES, WHICH STATES DESIGN IN | | ACCORDANCE WITH FLORIDA BUILDING CODE | | 2001.THE PERMIT APPLICATION WAS | | SUBMITTED DURING THE CODE OVERLAP PERIOD | | 7/1/05 THROUGH 10/1/05 SO EITHER EDITION | | COULD BE USED. HOWEVER BECAUSE THE | | SUBMITTED DCA APPROVED MODULAR BUILDING | | PLANS CITE 2001 FLORIDA BUILDING CODE, | | IT HAS BEEN ASSUMED THAT IS THE DESIRED | | CODE EDITION.THE PLANS MUST BE | | CONSISTENT.AMEND THE FOUNDATION PLAN. | | | | 7) THIS COMMENT HAS NOT BEEN PROPERLY | | ADDRESSED.THE 1/11/06 REVISION TO THE | | COMMENT RESPONSE LETTER INCLUDES AN ARCH | | ALUMINUM PRODUCT APPROVAL | | NOA# 00-1220.05 BUT STILL STATES "DOORS | | AND WINDOWS WILL BE SUBMITTED VIA | | SEPARATE PERMIT...".ONLY ONE COPY OF | | THE NOA WAS SUBMITTED.TO EXPEDITE | | REVIEW, TWO COPIES OF THE REQUIRED | | STATEWIDE PRODUCT APPROVAL COVER SHEET | | (SEE BELOW) HAVE BEEN PROVIDED BY THIS | | OFFICE.NO PRODUCT APPROVAL WAS | | SUBMITTED FOR THE DOORS OR STORM | | SHUTTERS.AS PART OF THIS PERMIT | | APPLICATION, TWO COPIES OF PRODUCT | | APPROVALS FOR THE STORM SHUTTERS AND | | DOORS AND STOREFRONT MUST BE SUBMITTED. | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | PRODUCT APPROVAL NUMBER (FL###), | | AVAILABLE FROM THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | (IF YOU FIND THAT THE QUOTED WEB PAGE IS | | NO LONGER AVAILABLE, PLEASE INFORM THE | | PLAN REVIEWER) | | | | 14) 472.025(1) F.S.BOUNDARY SURVEY | | SHEET S-1 IS NOT SIGNED AND SEALED BY | | JON V. NOLTING. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2005-12-19 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-12-19 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-11-14 |
Time |
08:49 |
Sent To |
|
|
Notes |
2005-12-16 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FLORIDA BUILDING CODE 2001 | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) 61G15-23.002(2)FL. ADMIN. CODE. | | ONLY ONE SET OF THE STRUCTURAL PLANS ARE | | SIGNED AND SEALED.ALSO, THE PRINTED | | NAME AND LICENSE NUMBER OF DAOUD | | ISKANDAR, P.E. MUST BE ADDED TO EACH | | SHEET (MAY BE ADDED BY HAND). | | PLANS SIGNED & SEALED BY A PROFESSIONAL | | ENGINEER SHALL INCLUDE EITHER THE NAME, | | ADDRESS AND LICENSE NUMBER OF THE | | ENGINEER OR, THE NAME AND LICENSE NUMBER | | OF THE ENGINEER AND THE NAME, ADDRESS | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH | | WHICH THE ENGINEER IS PRACTICING | | (471.025 F.S. AND 471.023 F.S.). | | | | 2) THE SUBMITTED FOUNDATION PLAN SHEET | | A-1 STATES DESIGN IN ACCORDANCE WITH | | 2004 FLORIDA BUILDING CODE WHILE | | STRUCTURAL SHEET S-0, GENERAL NOTES, | | STATES DESIGN IN ACCORDANCE WITH FLORIDA | | BUILDING CODE 2001.THE PERMIT | | APPLICATION WAS SUBMITTED DURING THE | | CODE OVERLAP PERIOD 7/1/05 THROUGH | | 10/1/05 SO EITHER EDITION COULD BE USED. | | HOWEVER BECAUSE THE SUBMITTED DCA | | APPROVED MODULAR BUILDING PLANS CITE | | FLORIDA BUILDING CODE, IT HAS BEEN | | ASSUMED THAT IS THE DESIRED CODE | | EDITION.THE PLANS MUST BE CONSISTENT. | | AMEND THE FOUNDATION PLAN. | | | | 3) FBC 11-4.1.3(8)(A)(II)THE NUMBER OF | | ACCESSIBLE ENTRANCES MUST BE AT LEAST | | EQUAL TO THE NUMBER OF REQUIRED EXITS. | | TWO EXITS ARE REQUIRED, SO AT LEAST TWO | | ACCESSIBLE ENTRANCES ARE REQUIRED. | | PROVIDE A RAMP OR SLOPED (LESS THAN 1 IN | | 20) PATH FROM THE FOUNTAIN AREA TO THE | | WEST PATIO TO MAKE THE WEST ENTRANCE | | ACCESSIBLE. | | | | 4) FBC 1-4.8.1SHEET C-5 SHOWS A PATH | | FROM EACH ACCESSIBLE PARKING SPACE THAT | | SLOPES UP FROM 20.90' TO 21.90' IN A | | DISTANCE THAT IS TOO SHORT TO ACHIEVE | | THE STATED MAX. 1 IN 20 SLOPE.AMEND | | THE LEVELS OR PROVIDE DETAILS FOR A RAMP | | INCLUDING HANDRAILS AND EDGE PROTECTION. | | | | 5) FBC 1007.5.7SHEET A-3.0EAST AND | | WEST ENTRANCE.THE STAIR HANDRAILS DO | | NOT ALIGN WITH THE DOORS.HANDRAILS | | SHALL BE LOCATED ALONG THE NATURAL PATH | | OF EGRESS TRAVEL.AMEND THE PLANS SO | | THAT THE HANDRALS ARE CENTERED ON THE | | EXIT DOOR LOCATION. | | | | 6) FBC* 104.2.1.2SHEET A-3.0THE | | PLANS DO NOT SHOW, OR MAKE REFERENCE TO, | | A SOUTH ELEVATION. | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE | | DOORS AND STOREFRONT. | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | PRODUCT APPROVAL NUMBER (FL###), | | AVAILABLE FROM THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | (IF YOU FIND THAT THE QUOTED WEB PAGE IS | | NO LONGER AVAILABLE, PLEASE INFORM THE | | PLAN REVIEWER) | | | | 8) FBC 1606.1CANOPIES.A SEPARATE | | PERMIT APPLICATION IS REQUIRED FOR THE | | CANVAS CANOPIES.THEY ARE TO BE | | DESIGNED FOR A WIND SPEED OF 140 MPH, 3 | | SECOND GUST IN EXPOSURE CATEGORY B. | | | | 9) FBC 1606.1.7SHEET E-1 SHOWS LIGHT | | POLES.SUBMIT WIND LOAD AND FOUNDATION | | CALCULATIONS/DETALS FOR THE LIGHT POLES. | | | | 10) FBC 104.2.1.2SHEET S-0 AND S-3 | | SHOW A "WORK AREA E".WHAT STRUCTURE IS | | THIS. | | | | 11) FBC 11-4.1.3(10)(A)DRINKING | | FOUNTAIN.A DRINKING FOUNTAIN IS | | REQUIRED.IT SHALL MEET THE CLEARANCE | | REQUIREMENTS OF FBC 11-4.14 AND FIG. 27 | | | | 12) FBC 11-4.24BREAK ROOM SINK.THE | | BREAK ROOM SINK SHALL HAVE THE REQUIRED | | CLEARANCES (FIG. 32) | | | | 13) FBC 1511.7MECHANICAL EQUIPMENT. | | THE ROOF MOUNTED MECHANICAL EQUIPMENT | | SHALL BE MOUNTED ON CURBS RAISED A | | MINIMUM OF 8 INCHES ABOVE THE ROOF | | SURFACE.WHERE THE ROOFING MATERIALS | | EXTEND BENEATH THE MECHANICAL EQUIPMENT | | THE SUPPORTS SHALL PROVIDE THE MINIMUM | | CLEARANCE GIVEN IN TABLE 1511.7. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-16 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-16 |
Time |
16:24 |
Sent To |
PC |
|
Notes |
2006-05-16 00:00:00 | REV FOR SERVICE AND SITE ONLY. | | | | REDLINED CONDUCTORS OUT TO PUMP, AS #6 | | IS NOT LARGE ENOUGH. 310.16 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-03-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-03-07 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-03-07 |
Time |
13:12 |
Sent To |
|
|
Notes |
2006-03-07 00:00:00 | REV SUBMITTED FOR LV SPEAKER SOUND | | SYSTEM WIRING MUST BE PULLED UNDER A | | SEPARATE PERMIT. | | CAN NOT REVISE THE STATE DCA APPROVED | | TRAILER PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-01-26 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-01-19 |
Time |
17:17 |
Sent To |
B |
|
Notes |
2006-01-26 00:00:00 | PLANS SIGNED,SEALED OK, STAMPED. | 2006-01-19 00:00:00 | ON HOLD, | | PLANS CONTAIN RAISED SEAL BY ENGINEER | | FOR STATE PLANS, HOWEVER PLANS ARE | | SEALED "PHOTOCOPIES" AND DO NOT CONTAIN | | AN ORIGINAL SIGNATURE FOR SAID PLANS. | | CONSULTATION WITH THE FLORIDA BOARD OF | | ENGINEER'S AND MO ADAMI WILL FOLLOW. | | | | PLEASE ALSO SEE PREVIOUS REVIEW WHICH | | REQUESTED ALL OLD/VOIDED SHEETS TO BE | | COMPLETELY REMOVED FROM SETS AND ONLY | | INSERT NEW REVISED SHEETS INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. ONLY ONE | | COPY OF OLD/VOIDED SHEETS SHOULD BE | | SUBMITTED WITH NEW SETS FOR REFERENCE | | ONLY. | | THIS WAS NOT DONE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2005-09-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
20:22 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2005-09-29 |
Time |
19:58 |
Sent To |
|
|
Notes |
2005-09-29 00:00:00 | ********** UNSAT ******** | | | | 1)NOTE: PLEASE SEE TITLE BLOCK ON STATE | | APPROVED TRIALERS IS MISSING REQUIRED | | CERTIFICATE OF AUTHORIZATION NUMBER AS | | REQUIRED UNDER FS 471.023, FAC | | 61G15-23.002. | | | | | | 2)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | AT 125% (3 OR MORE HRS). | | THIS IS SHOWN ON STATE PLANS. | | PLEASE ALSO CORRELATE LOADS AND LOAD | | CALCULATIONS SHOWN ON STATE PLANS AND | | PLANS SUBMITTED BY FES. | | 215.3,230.42, 220 ETC. | | | | 3)NOTE: PLEASE SUBMIT DETAIL FOR NEW | | FOUNTAIN, PUMP, LTS ETC. THIS SHOULD | | SHOW ALL GROUNDING, GFI PROTECTION FOR | | LTS, ANY SUBMERSIBLE PUMPS ETC.680.51 | | | | 4)NOTE: PLEASE SEE GROUNDING ELECTRODE | | SYSTEM RISER TO SHOW CWP AND NEW FOOTER | | STEEL. | | PLEASE ALSO SHOW GROUNDING DETAIL FOR | | TRAILERS. | | 250.50 | | | | 5)NOTE: PLEASE PROVIDE COMPLETE SIGNED, | | SEALED, DATED WIND LOADING CALCULATIONS | | AT THIS TIME FOR LT POLES AND LTS | | FIXTURES ATTACHED. | | ALL TO MEET FBC 140 MPH FASTEST MILE. | | PLEASE SEE BLDG REVIEW COMMENTS FOR | | THIS. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | PLANS. | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | AND ONNLY INSERT NEW REVISED SHEETS INTO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | PLEASE SUBMIT ONE SET OF ALL OLD/VOIDED | | SHEETS WHEN RE-SUBMITTING PLANS WHICH | | WILL BE USED FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATIONFOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2006-02-03 |
Time |
11:40 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2006-02-03 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2005-09-16 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2005-09-16 |
Time |
14:33 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2005-09-16 |
Time |
14:33 |
Sent To |
|
|
Notes |
2005-09-16 00:00:00 | FAILED: | | | | 1. SHEET C-5 STRUCTURE NO.1 WITH | | W.I.D.B., SHEET C-7 SHOWS IT AS CONTROL | | STRUCTURE #101, PLEASE CORRECT. | | 2. SHEET C-5 SHOWS INLETS STRUCTURES 1& | | 2 AS C-4 TYPE, TABLE ON SHEET C-7 SHOWS | | OTHER TYPE, DIMENSIONS DO NOT MATCHE | | THE CONTROL STRUCTURE #101, PLEASE | | VERIFY. | | 3. SHEET C-7 NO DIMENSIONS FOR THE | | PROPOSED EXFILTRATION ARE GIVEN. ALSO | | VERIFY THE I.E=14.5 WITH ESTIMATED | | SEASONAL HIGH WATER LEVEL=8.00. | | 4. SHEET C-7 NO DIMENSIONS FOR THE | | PROPOSED DUMPSTER ENCLOSURE ARE | | PROVIDED, IF CITY PICK UP, THEN SIZE PER | | THE CITY REQUIREMENTS. | | 5. SHEET C-7, APPROACH AS SHOWN DOES NOT | | MATCH STANDARD GC-4.1 ON SHEET C-8, | | PLEASE VERIFY. | | 6. PLEASE SUBMIT CIVIL PLANS TO THE | | PUBLIC UTILITIES AND ENGINEERING FOR | | APPROVAL OF ALL THE CONNECTION TO THE | | CITY SERVICES, 494-1085, MANNY GONZALEZ. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-02-09 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-02-09 |
Time |
11:25 |
Sent To |
|
|
Notes |
2006-02-09 00:00:00 | INTERIOR FINISH CLASSIFICATION OF WALLS | | AND CEILINGS SHALL BE CLASS A,B OR C IN | | ACCORDANCE WITH NFPA 101, 2003 EDITION, | | CHAPTER 10. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2005-11-09 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2005-11-09 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2005-11-09 |
Time |
14:44 |
Sent To |
|
|
Notes |
2005-11-09 00:00:00 | ******DENIED****** | | | | 1) AN ADDRESS NUMBER IS REQUIRED ON THE | | BUILDING, AND SHALL BE A MINIMUM OF 6" | | IN HEIGHT AND CONTRASTING TO THE | | BACKGROUND. | | | | 2) PLEASE PROVIDE FLAME SPREAD/RETARDANT | | INFORMATION FOR THE CANVAS CANOPY. | | | | 3) IN ADDITION TO FAN SHUT DOWN, DUCT | | SMOKE DETECTORS ARE REQUIRED TO HAVE | | AUDIBLE/VISUAL DEVICES IN THE AREA OF | | THE DETECTOR. | | | | 4) 2A-10B,C, RATED FIRE EXTINGUISHERS | | ARE REQUIRED AND SHALL BE MOUNTED TO | | SATISFY THE 75' TRAVEL DISTANCE | | REQUIREMENT. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-07 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-07 |
Time |
10:09 |
Sent To |
B |
|
Notes |
2006-06-07 00:00:00 | TO "RBROWN" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2006-05-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-08 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-08 |
Time |
10:36 |
Sent To |
E |
|
Notes |
2006-05-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2006-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-01 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-01 |
Time |
10:56 |
Sent To |
B |
|
Notes |
2006-05-01 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-25 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-25 |
Time |
11:27 |
Sent To |
B |
|
Notes |
2006-04-25 00:00:00 | TO "RBROWN" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2006-04-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-19 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-19 |
Time |
09:07 |
Sent To |
B |
|
Notes |
2006-04-19 00:00:00 | TO "RBROWN" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-04-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-05 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-05 |
Time |
16:44 |
Sent To |
B |
|
Notes |
2006-04-05 00:00:00 | TO "RBROWN" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-03-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-03-04 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-03-04 |
Time |
16:53 |
Sent To |
E |
|
Notes |
2006-03-04 00:00:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-01-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-12 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-12 |
Time |
16:22 |
Sent To |
I |
|
Notes |
2006-02-02 00:00:00 | TO "COMM" BD#15 | 2006-01-12 00:00:00 | SUBMITTAL W/APPLICATION WAITING FOR COMM | | BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-01-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-01-09 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-01-09 |
Time |
14:43 |
Sent To |
|
|
Notes |
2006-01-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2005-12-19 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-12-19 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-09-13 |
Time |
14:46 |
Sent To |
|
|
Notes |
2005-09-13 00:00:00 | TO "COMM" BD#34 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-02-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-02-14 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-02-14 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-02-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2006-02-06 |
Time |
18:31 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2006-02-06 |
Time |
18:30 |
Sent To |
|
|
Notes |
2006-02-06 00:00:00 | ----------------DENIED----------------- | | IN THE RESPONSE TO PATTY'S COMMENTS FROM | | HER FIRST REVIEW, IT IS STATED THAT | | FRESH AIR CALCULATIONS AND A CURB DETAIL | | ARE ATTACHED TO THE PLANS.WHILE I WAS | | ABLE TO SEE THE CURB DETAIL, I WAS | | UNABLE TO LOCATE ANY ATTACHMENT SHOWING | | FRESH AIR CALCULATIONS. | | | | RONALD J REGUEIRO | | 561.805.6734 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-11-10 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2005-11-10 |
Time |
15:57 |
Sent To |
|
|
Notes |
2005-11-10 00:00:00 | DENIED:2001 FBC | | 1.PLEASE PROVIDE OUTSIDE AIR | | CALUCALTIONS IN ACCORDANCE WITH 2001 | | FBC(M) TABLE 403.3. | | | | 2.PLAN SHEET 4 OF 7 INDICATES ROOF | | CURB TO BE INSTALLED BY OTHERS, SUBJECT | | TO LOCAL CODES.PER 2001 FBC 1511.7 | | ROOF CURBS SHALL BE A MINIMUM OF 8" | | ABOVE THE ROOF SURFACE.PLEASE PROVIDE | | ENGINEERED DETAIL FOR CURB ATTACHMENT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-02-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-02-17 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-02-17 |
Time |
12:50 |
Sent To |
|
|
Notes |
2006-02-17 00:00:00 | PASSED PROVISO:SINKS SHALL COMPLY WITH | | SECTIONS 11-4.24.4, 11-4.24.6, AND | | 11-4.24.7 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2005-11-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2005-11-12 |
Time |
17:32 |
Rev Time |
2.33 |
Received By |
kstevens |
Date |
2005-11-12 |
Time |
17:32 |
Sent To |
|
|
Notes |
2005-11-12 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 BUILDING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. SHT A-1.0 SUBMIT A DETAIL FOR THE | | FOUNTAIN. INDICATE IF WATER SERVICE WILL | | BE CONNECTED TO THE FOUNTAIN. IF SO, | | BACKFLOW PROTECTION WILL BE REQUIRED. | | SECTIONS 104.2.1. & 608. - INDICATE IF | | FOUNTAIN WILL HAVE A DRAIN TO SANITARY. | | IF SO A BACKWATER VALVE MAY BE RQUIRED. | | 2. SHT S2 NOTE "PROVIDE SCUPPERS & | | DOUBLE DRAINAGE SYSTEM". PLEASE INDICATE | | IF PARAPET WALLS WILL BE BUILT AROUND | | TRAILERS. SUBMIT CALCULATIONS FOR | | PRIMARY AND SECONDARY ROOF DRAINS IF | | THIS IS THE CASE. SHOW SQUARE FEET OF | | ROOF PLUS 1/2 AREA OF ALL VERTICAL WALLS | | INCLUDING PARAPETS ADDED TO SF OF ROOF | | IN CALCULATIONS. INDICATE LOCATION OF | | PRIMARY AND SECONDARY ROOF DRAINS, AS | | WELL AS THE SIZE OF EACH. SHOW HEIGHT | | AND WIDTH OF ALL SCUPPERS AS WELL AS A | | DETAIL SHOWING THE SCUPPERS MEASUREMENT | | FROM THE ROOF TO THE FLOW LINE OF EACH | | TYPE OF SCUPPER. (PRIMARY OR OVERFLOW). | | IF DOWNSPOUTS WILL BE USED INDICATE SIZE | | OF DOWNSPOUTS. SECTIONS 1106 & 1107 AND | | ALL SUBSECTIONS. ALSO SECTION 1503.4.2. | | 3. SHTS LC-1 THRU LC-4 TITLE BLOCK | | REQUIRED BY FAC 61G1-16.004 IS REQUIRED | | ON EACH SHEET. SHOW ALL REQUIRED | | INFORMATION REQUIRED BY FAC AND FS | | 481.301. - THE PERSONAL SIGNATURE OF THE | | LANDSCAPE ARCHITECT IS REQUIRED ON THE | | SEAL. IT APPEARS THAT INITIALS WERE | | USED. A SIGNED, SEALED, NOTORIZED LETTER | | WITH PROPER TITLE BLOCK SHALL BE | | SUBMITTED FOR OUR FILE TO INDICATE LEGAL | | SIGNATURE. | | 4. SHT LC-3 BACKFLOW FOR IRRIGATION | | SHALL BE PERMITTED AND INSTALLED BY A | | LICENSED PLUMBING CONTRACTOR. | | 5. SHT 2 OF 7 BREAK AREA SINK SHALL BE | | ACCESSIBLE. SUBMIT A DETAIL SHOWING | | COMPLIANCE WITH SECTION 11-4.24 AND ALL | | SUBSECTIONS. SHOW REQUIRED FRONTAL | | APPROACH CLEAR FLOOR SPACE. | | 6. PER TABLE 403.1 A DRINKING FOUNTAIN | | IS REQUIRED. SUBMIT A DETAIL SHOWING | | COMPLIANCE WITH SECTION 11-4.15 AND ALL | | SUBSECTIONS AS WELL AS SECTION | | 11-4.1.3(10)(A) REQUIREMENTS FOR THOSE | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2005-10-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2005-10-05 |
Time |
10:30 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2005-10-05 |
Time |
10:00 |
Sent To |
|
|
Notes |
2005-10-05 00:00:00 | PROVISO - PARKING SHALL BE DOUBLE | | STRIPED PER CODE. |
|
|